Frigidaire | FFTH0822U1 | Spec sheet | Frigidaire FFTH0822U1 Spec Sheet

Frigidaire FFTH0822U1 Spec Sheet
HOME COMFORT
FFTH0822U1
THROUGH-THE-WALL
AIR CONDITIONER/HEATER
PRODUCT DIMENSIONS
Height
14-9/16"
Width
24"
Depth
20-5/8"
MORE EASY-TO-USE FEATURES
Supplemental Heating Option
With our supplemental heating capability,
you can be comfortable regardless of the
temperature outside — you have both heating
and cooling solutions!
Sleep Mode
With Sleep Mode, the temperature gradually
increases a few degrees over the evening, saving
energy and creating a comfortable environment
during the evening hours.
Remote Control
Offers you the flexibility to control the
temperature and fan speed from anywhere
in the room.
Effortless™ Clean Filter
Our antibacterial filter reduces bacteria, room
odors and other airborne particles for a
healthier, more comfortable environment.
SIGNATURE FEATURES
Power Cord
Comes with an extra long three-prong cord —
makes extension cords unnecessary.
Effortless™ Restart
Effortless™
Temperature Control
Our air conditioners maintain
the preset room temperature, so
you will remain comfortable at
all times.
Programmable
24-Hour On/Off Timer
With the 24-Hour On/Off Timer,
you can ensure your home will
be cool and comfortable when
you want it to be without having
to worry about running up your
utility bills. The built-in timer
allows you to preset the unit
to turn on and off in half-hour
increments.
Energy Saver Mode
Reduce your utility bills in this
mode. It cools similarly to central
air, with the unit turning on
and off at different intervals to
ensure the room temperature
stays at the set temperature.
Automatically resumes operating at its previous
settings when power is restored to your unit.
Clean Filter Alert
Alert notifies you when your filter needs to be
cleaned so you don’t have to keep track of it
yourself.
Ready-Select® Controls
Easily select options with the touch
of a button.
Multi-Speed Fan
Features three different fan
speeds, for more cooling
flexibility.
PERFORMANCE
BTUs
Cool
8,000
Heat
4,200
frigidaire.com
FFTH0822U1
HOME COMFORT
RAC Through-The-Wall “U” Models
Frigidaire Baseline
THROUGH-THE-WALL AIR CONDITIONER/HEATER
PERFORMANCE
PRODUCT DIMENSIONS
BTU (Cool)
8,000
A - Height
14-9/16"
BTU (Heat)
4,200
B - Width
24"
Dehumidification (Pints / Hour)
1.9
C - Depth
20-5/8"
Cool Area (Up To Sq. Ft.)
350
D - Max. Wall Thickness
18"
Combined Energy Efficiency Ratio
9.6
Energy Efficiency Ratio
9.6
SLEEVE CUTOUT DIMENSIONS
ELECTRICAL
Volts
115
Amps (Cool)
8.0
Amps (Heat)
11.8
Watts (Cool)
830
Watts (Heat)
1,220
Length of Power Cord (Min. / Max.)
6' / 6.5'
Plug Type (NEMA)
LCDI (5-15P)
Height
15-5/8"
Width
25-15/16"
FEATURES
Electronic Controls
Ready-Select® Controls
Fan Speeds (Cool / Fan / Heat)
3/3/3
Low Voltage Start-Up
Yes
Auto Cool Function
Yes
Energy Saver Mode
Yes
Sleep Mode
Yes
Filter Check
Yes
24-Hour On / Off Timer
Yes
Clean Air Ionizer
Remote Control
Full-Function with Heat
Air CFM (High / Med / Low)
280 / 259 / 230
Air Direction Control
6-Way
Fresh Air / Exhaust Vent / Closed
No / No / Yes
Filter Type
Antibacterial Mesh
Filter Access
Slide-Out
A
Slide-Out Chassis
Warranty1
Yes
OPTIONAL ACCESSORIES
Through-The-Wall 18" Sleeve Kit
PN # 5304514430
Trim Kit (for larger existing sleeve)
Included
Architectural-Style Exterior Louvered Grille
PN # 5304515640
CERTIFICATIONS
Performance
C
AHAM
SPECIFICATIONS
Refrigerant
R410a
Shipping Weight (Approx.)
78 Lbs.
B
D
Warranty five (5) years full parts and labor.
1
Plug Type (NEMA)
5-15P
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Specifications subject to change. Accessories information available on the web at frigidaire.com
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
FFTH0822U1 06/18
© 2018 Electrolux Home Products, Inc.
Frigidaire Baseline
FFTH0822U1
HOME COMFORT
THROUGH-THE-WALL AIR CONDITIONER/HEATER
Through-The-Wall Installation
Wall (thickness)
14 9/16"
18"
max.
20 /8"
5
24"
Through-The-Wall 18" Sleeve Kit
(PN # 5304514430)
Outside closure panel
Wall
Plug Type (NEMA)
5-15P
Adjustable
mounting
brackets
Locking clip
Sleeve-to-unit seal
Building construction support
INSTALLATION SPECIFICATIONS
• Product Shipping Weight (approx.) – 78 Lbs.
• An electrical supply with grounded three-prong receptacle is required.
The power supply circuit must be installed in accordance with current edition
of National Electrical Code (ANSI/NFPA 70) and local codes & ordinances.
• Voltage Rating – 115V / 60 Hz / 15 Amps
• Amps @ 115 Volts = (Cool) 8 Amps / (Heat) 11.8 Amps
• Recommended Circuit Breaker – 15 Amps
• Unit equipped with 115V 3-wire power supply cord, NEMA plug type 5-15P,
approximately 72" long.
• Unit’s increased performance characteristics result from two rear intakes.
For unit to operate at maximum efficiency, carefully follow complete, detailed
new or replacement installation instructions provided in Product Installation
Guide on web.
• Unit requires rearward slope when installation is complete, to allow
condensate to drain from rear of sleeve.
NEW INSTALLATION
• For new installation, Frigidaire® Through-The-Wall 18" Sleeve Kit
PN # 5304514430 available. Recommended for proper installation.
• Through-the-wall installation requires 18" maximum wall thickness.
• For energy-saving purposes, install unit in shady location, preferably a
northern exposure; and do not block airflow inside with blinds, curtains or
furniture; or outside with shrubs, enclosures or other buildings.
REPLACEMENT INSTALLATION
• When replacing existing air conditioner with new unit, refer to Product
Installation Guide on web to identify existing wall-sleeve manufacturer and
size compatibility. If proper installation and slope are suspect, then correct
installation of Frigidaire® Through-The-Wall 18” Sleeve Kit PN # 5304514430
recommended.
• Use of existing wall sleeve to mount new unit requires original sleeve be
in sound structural condition with rear grille that attaches securely, or rear
flange that serves as stop for unit.
• Preferable installation option, for increased efficiency and possibility of
drafts reduced, requires existing rear grille (mounted to sleeve) be replaced
with new unit’s rear air-directional louvered grille (provided in accessory kit,
shipped with unit). Non-preferable installation option of directly mounting rear
louvered grille to unit can be considered, requiring grille be mounted to unit
prior to sleeve installation.
• Existing decorative exterior grille may be left in place, provided that proper
air-directional rear louvered grille is installed.
• For installation into larger existing sleeve, optional Trim Kit is included.
OPTIONAL ACCESSORIES
• Through-The-Wall 18" Sleeve Kit – (PN # 5304514430).
• Trim Kit (for larger existing sleeve) – Included.
• Architectural-Style Exterior Louvered Grille – (PN # 5304515640).
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Specifications subject to change. Accessories information available on the web at frigidaire.com
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
FFTH0822U1 06/18
© 2018 Electrolux Home Products, Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising