Electrolux | EI32AF80QS | English Wiring Diagram | Electrolux EI32AF80QS English Wiring Diagram

service data sheet - 297299800
40 to 50%
55 to 65%
Freezer Temperature
-3° to 3° F
-19° to -16° C
-3° to 3° F
-19° to -16° C
Low Side Pressure
(cut-in)
6 to 12 psig
41 to 83 kPa
6 to 12 psig
41 to 83 kPa
Low Side Pressure
(cut-out)
-1 to 3 psig
-4 to 21 kPa
-1 to 3 psig
-4 to 21 kPa
Operating Time
High Side Pressure
(last 1/3 cycle)
85 to 100 psig
575 to 670 kPa
120 to 135 psig
810 to 910 kPa
100 to 120
110 to 130
.9 to 1.1
1.0 to 1.2
Wattage (last 1/3 cycle)
Amps (running)
Base Voltage
important safety notice
The information provided herein is designed to assist qualified
repair personnel only. Untrained persons should not attempt to
make repairs due to the possibility of electrical shock. Disconnect
power cord before servicing.
Remove cover by inserting screwdriver in notch at bottom and
prying cover from housing. Use screwdriver to rotate motor gear
counterclockwise until holding switch circuit is completed. All
components of ice maker should function to complete the cycle.
Water Fill Volume
Water Fill
Adjustment
Motor
Gear
If any green grounding wires are moved during servicing,
they must be returned to their original position and properly
secured.
TU
R
N
DEFROST SPECIFICATIONS
19’
Test Cycling
important
115 vac (127 vac max)
Thermostat
Cabinet Size
STANDARD - AUTOMATIC DEFROST FREEZER
MODELS (r134a)
iCE MAKER INFORMATION
Heater
Cut-in
Cut-out
Watts
Ohms
21° F (-6° C)
42° F (6° C)
550
24
Electronic Timer - Defrost 30 minutes every 12 hours of compressor run time.
caution: All electrical parts and wiring must be
shielded from torch flame. Do not allow torch to contact
insulation; it will char at 200°F.
Mounting
Plate
Screw
CONDENSER FAN MOTOR
Watts
RPM
Amps
2.3
1100 CW Opposite Shaft
0.13 Running
ICE MAKER SPECIFICATIONS
115 vac (127 vac max) 60 Hertz
Thermostat
Opens at 48° F ( 9° C), Closes at 15° F ( -9° C)
Models with orange wire close at 8.96° F (-12.8° C)
Heater Wattage
165
Timing
Gear
NOTE: Products come equipped with an Electronic Defrost
Control. To initiate defrost, press and hold air filter and alarm
reset key simultainiously for three seconds. To terminate defrost,
press and hold air filter and alarm reset key simultainiously for
three seconds
ICE MA KER
Ground
2
Yellow
Water Valve
3
Black
Line
4
Light Blue
Neutral
P-3
THER MAL
CUT-OUT
BLK
Connects to:
Green/Yellow
MOTOR
HO LD
SW ITCH
RED
YEL
T HERMOSTAT
BLU
GRN / yEL
BLK
SHUT-OF F
SWITCH
GRN / yEL
LT. BLU
P-1
MOL D
MOUN TING
PLATE
WATER FILL
S WITCH
ICE MAKER
IMPORTANT: PLEASE RETURN THIS SHEET TO IT’S
ORIGINAL LOCATION
MOLD HEATER
P-4
P-2
WATER VALVE
Wire Color
1
ICE MAKER
Wire Number
BRN
B LK
ICE MAKER
ICE MAKER CONNECTOR PLUG CONNECTIONS
NEUT RAL
POWER
LINE
BLK
Electrical
Mounting
Plate
Screws
The water fill adjustment
screw will change the
fill time. One full turn is
equal to 20cc (.68 oz.).
The correct fill is 95 to
105cc (3.2 to 3.6 oz.).
When a water valve is
replaced, the fill volume
must be checked.
YEL
90°F (32°C) Ambient
LT. BLU
70°F (21°C) Ambient
YEL
Capacitor Run or
Induction Run
RED
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT
CONTROL SETTING