QUICK START GUIDE Combo® Models • 115 V / 60 Hz QUICK START GUIDE u-line.com WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine use. U-Line’s complete product collection includes modular Wine Captain® Models, Beverage Centers, Clear Ice Machines, Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, and Combo® Models. U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations and attention to even the smallest details. We are known and respected for our unwavering dedication to product design, quality and selection. U-Line is headquartered in Milwaukee, Wisconsin with a west coast office located in Laguna Beach, California and European support in Dublin, Ireland. U-Line has shipped product to five continents for over two decades and is proud to have the opportunity to ship to you. PRODUCT INFORMATION Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance Documentation, and Product Warranty information are all available for reference and download at u-line.com under Documentation. PROPERTY DAMAGE / INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following steps: 1. U-Line Customer Care must be contacted immediately at +1.800.779.2547. 2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible. SERVICE INFORMATION Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our Customer Care group directly, contact information below. GENERAL INQUIRIES SERVICE & PARTS ASSISTANCE U-Line Corporation Monday - Friday 8:00 am to 5:30 pm CST 8900 N. 55th Street T: +1.800.779.2547 Milwaukee, Wisconsin 53223 USA F: +1.414.354.5696 Monday - Friday 8:00 am to 4:30 pm CST Service Email: [email protected] T: +1.414.354.0300 Parts Email: [email protected] F: +1.414.354.7905 Email: [email protected] u-line.com CONNECT WITH US Designed, engineered and assembled in WI, USA QUICK START GUIDE Contents 1 Model List 2 Safety and Warning 2 Environmental Requirements 3 Electrical 3 Water Hookup 5 Door Swing 6 General Installation 7 Integrated Panel Installation 10 Control Operation 11 First Use 11 Ice 12 Sabbath Mode 12 Warranty u-line.com QUICK START GUIDE u-line.com Model List This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides for all U-Line products. Combo® Models U-CO29FB-00A U-CO1224FS-00B U-CO29FW-00A U-CO1224FINT-00B U-CO1224FB-40B U-CO1224FW-00B Marine Series ULN-CO29B-03A ULN-CO29B-20A ULN-CO29W-03A ULN-CO29W-20A Visit http://www.u-line.com/product-literature/userguides or scan this QR code to view all user guides online. 1 QUICK START GUIDE u-line.com Safety and Warning Environmental Requirements NOTICE This model is intended for indoor/interior applications only Please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide: SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger, Warning or Caution based on the risk type: and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models. For best performance, keep the unit out of direct sunlight and away from heat generating equipment. In climates where high humidity and dew points are ! DANGER Danger means that failure to follow this safety present, condensation may appear on outside surfaces. This is considered normal. The condensation will evaporate when the humidity drops. statement will result in severe personal injury or death. ! WARNING Warning means that failure to follow this safety ! CAUTION Damages caused by ambient temperatures of 40°F (4°C) or below are not covered by the warranty. statement could result in serious personal injury or death. ! CAUTION Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage. 2 QUICK START GUIDE Electrical ! WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. u-line.com Water Hookup PREPARE PLUMBING The water valve uses a standard 1/4" (6.35 mm) compression fitting. U-Line recommends using accessory water hook up kit – part # WATERHOOKUP. The kit includes a 10' (3 m) braided flexible water supply line and a brass hose fitting. When using a 1/4" (6.35 mm) O.D. soft copper supply line use the brass nut and sleeve included with the unit. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. ! CAUTION Altering, cutting or removing power cord, Plumbing installation must observe all state and removing power plug, or direct wiring can cause local codes. All water and drain connections serious injury, fire, loss of property and/or life, MUST BE made by a licensed/qualified plumbing and will void the warranty. contractor. Failure to follow recommendations and instructions may result in damage and/or Never use an extension cord to connect power to harm. the unit. Water Supply Connection Always keep your working area dry. NOTICE Electrical installation must observe all state and When connecting the water supply, please note the following: • Before installing the unit and connecting to the cold water supply, review the local plumbing codes. local codes. This unit requires connection to a grounded (three-prong), polarized receptacle that has been placed by a qualified electrician. The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit • The water pressure should be between 20 and 120 psi (138 and 827 kPa). • The water line MUST have a shut-off valve in the supply line. breaker is recommended. A GFCI (ground fault circuit interrupter) is usually not required for fixed location • The water line should be looped into 2 coils. This will appliances and is not recommended for your unit because allow the unit to be removed for cleaning and servicing. it could be prone to nuisance tripping. However, be sure Make certain that the tubing is not pinched or damaged to consult your local codes. during installation. ! WARNING Connect to potable water supply only. 3 QUICK START GUIDE ! CAUTION u-line.com 3. Locate water valve inlet. Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home. Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber gasket. The gasket provides an adequate seal – other materials could cause blockage of the valve. 4. Break away filler feature Failure to follow recommendations and instructions may result in damage and/or harm, in bushing with flat screwdriver. flooding or void the product warranty. Use new hose set. Do not reuse old hose set. ! CAUTION Turn off water supply and disconnect electrical Remove ZLWKɠDW screwdriver 5. Thread water line through back panel hole (with bushing). supply to unit prior to installation. 6. Locate water valve inlet Use caution when handling back panel. The and connect to valve. edges could be sharp. 7. Turn on water supply 1. Turn off water supply and disconnect electrical supply and check for leaks. to product prior to attempting installation. 8. Reinstall back panel. 2. Remove the back panel. 4 QUICK START GUIDE u-line.com Integrated models require 1/4" (6 mm) clearance if 9. Install retaining clip. installed next to a wall. Allow for additional space for any knobs or pulls installed on the integrated panel/frame. BI95/BI98 All units have a zero clearance for the door to open 90°. U-Line recommends a minimum door clearance of 1/4" (6 mm) to accommodate the handle if the unit is installed next to a wall. 1/4" Min. (6 mm) 90° Door Swing Door Swing CRESCENT ICE MAKERS, OUTDOOR SERIES AND ADA15IM Wall Wall 1/4" Min. (6 mm) 2-1/8" Min. (54 mm) MARINE SERIES All units have a zero clearance for the door to open 90°. U-Line recommends a minimum door clearance of 3/4" (19 mm) to accommodate the handle if the unit is installed next to a wall or similar type of structure. Wall 3/4" (19 mm) Min. 90° Door Swing 90° Door Swing Units have a zero clearance for the door to open 90°, 90° Door Swing when installed adjacent to cabinets. Stainless Steel and black and white models require 2-1/8" (54 mm) door clearance to accommodate the handle if installed next to a wall. 5 QUICK START GUIDE u-line.com General Installation CRESCENT ICE MAKERS, OUTDOOR SERIES AND ADA15IM MARINE AND BI95/BI98 SERIES LEVELING INFORMATION LEVELING INFORMATION 1. Use a level to confirm the unit is NOTICE Because these units do not have leveling legs, it is extremely important that they sit on a level surface. If they are not level, the ice mold will not fill evenly. level. Level should be placed along top edge and side edge as shown. Use a level to confirm 1 the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not level, adjust the legs on the corners of the unit as necessary. INSTALLATION 1. Plug in the power/ electrical cord. 1 2. Gently push the unit into position. Be careful not to entangle the cord and water line. Turn to Adjust 3. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. 3. Confirm the unit is level after each adjustment and 4. Remove the interior packing material and wipe out the repeat the previous steps until the unit is level. inside of the unit with a clean, water-dampened cloth. INSTALLATION TIP If the room floor is higher than the floor in the cutout opening, adjust the rear legs to achieve a total unit rear height of 1/8" (3 mm) less than the opening’s rear height. Shorten the unit height in the front by adjusting the front legs. This allows the unit to be gently tipped into the opening. Readjust the front legs to level the unit after it is correctly positioned in the opening. 6 QUICK START GUIDE INSTALLATION 1. Plug in the power/electrical cord. u-line.com 2. Pull door gasket out of groove (top edge of door only). Start in the middle and pull outward, 2. Gently push the unit into position. Be careful not to kink the water supply line or entangle the cord. moving toward the edge. This may take some force. 3. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit’s top surface should be approximately 1/8" (3 mm) below the countertop. 3. Remove two outside screws holding door handle. Slightly separate door handle from door. 4. Install the anti-tip bracket. 4. Pull handle up and off. 5. Remove interior packing material and wipe out the inside of the unit with a clean, water-dampened cloth. 5. Slide custom door panel insert into 1/4" (6 mm) channel in door front. Integrated Panel Installation NOTICE CO29F Use care not to damage magnet, located on door This model accepts a 1/4" insert panel. bottom when installing door insert. Do not set INSERT PANEL INSTALLATION Install the insert as follows: door on bottom edge when pushing insert into place. 6. Holding door gasket out of the way, replace handle on door, making sure it is seated properly on insert and ! CAUTION Use care when handling the insert. Insert edges that screw holes line up. 7. Install two small screws removed in Step 3. may be sharp. 8. Starting at the corners and working inward, push door 1. Remove top hinge screw pin gasket into place on door. with Phillips head screwdriver. Remove door by tilting forward and lifting off bottom hinge pin. 9. Place door on bottom hinge pin and install upper hinge screw. 7 QUICK START GUIDE u-line.com CO1224F Due to differences in floor construction or 1. Fully open door/drawer. surrounding cabinetry, the panel may not sit flush with the top of the door/drawer. 2. Starting at corner, pull gasket away from door/ Panel Door drawer. 3. Continue to pull gasket free from gasket channel. 9. Secure integrated panel to door/drawer 4. Upon removal, lay gasket Bar Clamp using clamps. A down on a flat surface. robust tape may also 5. Partially loosen the 3 screws, securing the top hinge to the cabinet. be used. U-Line recommends the use of bar clamps to Door/Drawer secure the panel to 6. Align the panel with the outside edge (opposite the the door/drawer. If hinge) and high enough to align with the highest point using tape, be in the door/drawer. certain the tape will Wood Panel not damage panel 7. Insert panel underneath top hinge and apply upward finish upon removal. pressure while bringing the lower portion of the panel flush to the door inside the lower hinge. The panel will fit snuggly 10.Using a 7/64" (3 mm) drill bit, drill 6 pilot Bar Clamp holes into the wood 8. Align door with cabinet. Tighten the top 3 screws, securing the top hinge to the cabinet. Align Top Of Panel With Highest Point Of Door/Drawer panel 1/2" (12 mm) deep using the holes in the door/drawer frame as a guide. It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardwood is installed. Align Panel Against Door/Drawe Edge First 11.Locate 6 of the #6x 1-1/4" (32 mm) screws provided with your unit. 12.Using a Phillips screwdriver, place one screw into each of the 6 pilot holes and screw down. Do not overtighten screws. 8 QUICK START GUIDE u-line.com 13.Be sure the screws force their way past the opening on the gasket channel and sit flush against the bottom of the channel. Integrated Panel Integrated Panel 14.Remove clamps from door/drawer. If panel requires additional adjustment after removing clamps, slightly loosen each screw and adjust panel as necessary. Tighten screws upon completion. 9 QUICK START GUIDE u-line.com Starting at the corners, re-install the gasket into the seated. This may take some force.Control gasket channel in the frame. Make sure the gasket is fully Operation Up Down Not Light Power Used LED CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY/OPTIONS ON/OFF Press and release Unit will immediately turn ON or OFF. Press and release to leave interior Toggle lights Adjust refrigerator set light on for 3 hours Press or and release View temperature in unit Press and together and release Toggle between F/C Hold point and for 5 seconds Glass door wine and beverage centers only. When the “F” or “C” in the display is flashing, press or to adjust the set point temperature. The display will flash and then toggle from set point to temperature in unit. The display will change units. DOOR ALERT NOTIFICATION When the door is left open for more than 5 minutes: • An audible tone will sound for several seconds every minute. • “dr” will appear in display. Close door to silence alert and reset. 10 QUICK START GUIDE u-line.com First Use To turn off ice production: Raise the bin arm into All U-Line controls are preset at the factory. Initial startup temperature for ice storage. an upright and locked position. The unit will preserve requires no adjustments. NOTICE NOTICE If not intending to use the ice maker, turn the U-Line recommends allowing the unit to run water supply valve off. It is also important to overnight before loading with product. raise the bin arm of the ice maker (see above). Failure to raise the bin arm may result in damage U-Line recommends discarding the ice produced to the water valve. during the first two to three hours of operation to avoid possible dirt or scale that may dislodge Certain sounds are normal during the unit’s operation. You from the water line. may hear the compressor or fan motor, the water valve, or ice dropping into the ice bucket. When plugged in, the unit will begin operating under the factory default settings. If the unit was turned off during installation, simply press and the unit will immediately switch on. To turn the unit off, press and hold for 5 seconds and release. ! CAUTION NEVER use an ice pick, knife or other sharp instrument to separate cubes. Shake the ice bucket instead. Ice During periods of limited use or high ambient temperatures, it is common for cubes to fuse together. ICE MAKER OPERATION When the ice bucket is full, the ice making mechanism will shut off. However, the refrigeration system will continue to cool and maintain the ice supply. Gently shake the bucket to break apart cubes. If not using the ice maker regularly, empty the ice bucket periodically to ensure fresh cubes. It is normal for cubes to appear cloudy. The cause is air NOTICE trapped in the water because of fast freezing. It is not Do not place cans or bottles in the ice caused by the health, taste or chemical make up of the compartment because they will freeze. water. It is the same air that is in every glass of water you drink. OFF Remove the ice bucket for emptying and cleaning. To remove the ice bucket, raise the bin arm and remove the bucket from the ice compartment. Use the ice bucket for ON ice storage only. 11 QUICK START GUIDE u-line.com Warranty U-LINE CORPORATION LIMITED WARRANTY Sabbath Mode 1. U-Line Corporation (“U-Line”) warrants each U-Line product to be free from defects in materials and workmanship for a period of one year (two years on 1 2 3 4 5 6 7 Modular 3000 Series) from the date of installation. U-Line further warrants the sealed system (consisting of the compressor, condenser, evaporator, hot gas bypass valve, dryer, and connecting tube) in each This unit is Star-K certified and offers a Sabbath mode. U-Line product to be free from defects in materials and Sabbath mode disables system responses to user initiated workmanship for a period of five years from the date of activities and all external functions, including lighting, installation. display and audible alarms. The unit will still maintain internal temperatures and set points. View a full list of Star-K certified U-Line units at www.star-k.org. 2. During the initial one-year warranty period (two years on Modular 3000 Series) for all U-Line products U-Line shall: (1) repair any product or replace any part of a product; and (2) for all Marine, RV, and Domestic To enable Sabbath Mode: U-Line products sold and serviced in the United States (including Alaska and Hawaii) and Canada, U-Line 1. Press (4) and hold for ten seconds and release (the shall be responsible for the labor costs performed by a °F/°C symbol will flash briefly at the end of the ten U-Line authorized service company, incurred in second period). connection with the replacement of any defective part. During years two through five of the warranty period 2. The interior light and control display (3) will go dark until user resets mode. for the sealed system, U-Line shall: (1) at U-Line’s option repair or replace any part of the sealed system; and (2) for all Marine, RV, and Domestic U-Line 3. NOTE: Although the display will not be visible, the temperature controls in the unit remain active and preserve the interior temperature. products sold and serviced in the United States (including Alaska and Hawaii) and Canada, U-Line shall be responsible for the labor costs incurred in connection with the replacement of any defective part of the sealed system. All other charges, including 4. Access the Ice Maker behind the freezer door and lift transportation charges for replacements under this the wire lever until it engages and remains in the lifted warranty and labor costs not specifically covered by position. this warranty, shall be the responsibility of the purchaser. This warranty extends only to the original 5. Sabbath Mode remains active until (4) is quickly pressed and released. Ice production will remain suspended until the lever is placed back into its original (Lowered) position. purchaser of the U-Line product. The Product Registration Card included with the product should be promptly completed by you and mailed back to U-Line, or you can register on-line at www.u-line.com. 3. The warranty listed above does not apply to floor display models. The warranty for these models shall be one year from the date of installation. This one-year 12 QUICK START GUIDE u-line.com warranty does not apply to cosmetic damages. A proof 1-800-779-2547 or the dealer from whom you of purchase may be required. purchased the product. In no event shall such notification be received later than 30 days after the 4. The following conditions are excluded from this limited warranty: use of cleaners other than the recommended stainless steel cleaners and U-Line Clear Ice Maker cleaner; installation charges; damages caused by disasters or acts of God, such as fire, floods, wind, and lightning; damages incurred or resulting from shipping, expiration of the applicable warranty period. U-Line may require that defective parts be returned, at your expense, to U-Line’s factory in Milwaukee, Wisconsin, for inspection. Any action by you for breach of warranty must be commenced within one year after the applicable warranty period. improper installation, unauthorized modification, or misuse/abuse of the product; customer education 8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL calls; food loss and spoilage; door and water level OTHER WARRANTIES, EXPRESS OR IMPLIED, adjustments (except during the first 30 days from the INCLUDING ANY IMPLIED WARRANTY OF date of installation); defrosting the product; adjusting MERCHANTABILITY OR IMPLIED WARRANTY OF the controls; door reversal; and cleaning the FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH condenser. ARE DISCLAIMED. U-Line’s sole liability, and your exclusive remedy, under this warranty is set forth in 5. U-Line products are designed to operate in ambient temperatures between 50°F and 100°F unless otherwise noted in the product manual. Exposure to temperatures outside this range may cause degradation of performance and issues, such as lower ice production or spoiled contents, that are not covered under the terms of this warranty as a result of the paragraphs above. U-Line shall have no liability whatsoever for any incidental, consequential, or special damages arising from the sale, use, or installation of the product or from any other cause whatsoever, whether based on warranty (express or implied) or otherwise based on contract, tort, or any other theory of liability. that exposure. U-Line product may not be subjected to temperatures below 40°F without following the 9. Some states do not allow limitations on how long an winterization and vacation shutdown procedures in the implied warranty lasts or the exclusion or limitation of user guide. incidental or consequential damages, so the above limitations may not apply to you. This warranty gives 6. U-Line’s Outdoor Limited Warranty, set forth in this Paragraph 6 shall apply to U-Line models deemed you specific legal rights, and you may also have other rights which vary from state to state. suitable for outdoor use by Underwriters Laboratory (“UL”) as noted in the U-Line Product Catalog, U-Line’s website, and/or on the serial tag located inside the product. Outdoor product may come into contact with rain by virtue of outdoor use. Exposure to other sources of water shall also cause this warranty to be void, including flooding of the area in proximity of the unit greater than 1/8" deep in water, hurricanes, splashing of pool water, or directing a spray from a hose or similar device into and around the unit. 7. If a product defect is discovered during the applicable warranty period, you must promptly notify U-Line at Copyright © 2016 U-Line Corporation. All Rights Reserved. Publication Number 30443 5/2016 Rev.B 13
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement