U-Line | U-CLR1215SOD-00B | Quick Start Guide | U-Line UCLR1215INT00B Quick Start Guide

QUICK START GUIDE
1000 Series
•
CLR1215
•
115 V / 60 Hz
QUICK START GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations
of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American
leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine
use. U-Line’s complete product collection includes modular Wine Captain® Models, Beverage Centers, Clear Ice Machines,
Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, and Combo® Models.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin with a west coast office located in Laguna Beach,
California and European support in Dublin, Ireland. U-Line has shipped product to five continents for over two decades and is
proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance
Documentation, and Product Warranty information are all available for reference and download at u-line.com under
Documentation.
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.800.779.2547.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
SERVICE INFORMATION
Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our
Customer Care group directly, contact information below.
GENERAL INQUIRIES
SERVICE & PARTS ASSISTANCE
U-Line Corporation
Monday - Friday 8:00 am to 5:30 pm CST
8900 N. 55th Street
T: +1.800.779.2547
Milwaukee, Wisconsin 53223 USA
F: +1.414.354.5696
Monday - Friday 8:00 am to 4:30 pm CST
Service Email: onlineservice@u-line.com
T: +1.414.354.0300
Parts Email: onlineparts@u-line.com
F: +1.414.354.7905
Email: sales@u-line.com
u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
QUICK START GUIDE
Contents
1
Model List
2
Safety and Warning
2
Environmental Requirements
3
Electrical
3
Water Hookup
7
Drain
8
Door Swing
9
General Installation
9
Integrated Panel Installation
11
Control Operation
11
First Use
11
Ice
13
Sabbath Mode
13
Warranty
u-line.com
QUICK START GUIDE
u-line.com
Model List
This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides
for all U-Line products.
Clear Ice
U-CLR1215S-00B
U-CLR1215S-40B
U-CLR1215INT-00B
U-CLR1215INT-40B
U-CLR1215B-00B
U-CLR1215B-40B
U-CLR1215W-00B
U-CLR1215W-40B
Outdoor Series
U-CLR1212SOD-00B
U-CLR1212SOD-40B
Visit http://www.u-line.com/product-literature/userguides or
scan this QR code to view all user guides online.
1
QUICK START GUIDE
u-line.com
Safety and Warning
This unit is designed to operate between 50°F (10°C) and
NOTICE
the unit’s ability to reach low temperatures and/or reduce
100°F (38°C). Higher ambient temperatures may reduce
ice production on applicable models.
Please read all instructions before installing,
operating, or servicing the appliance.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide:
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
SAFETY ALERT DEFINITIONS
evaporate when the humidity drops.
Throughout this guide are safety items labeled with a
Danger, Warning or Caution based on the risk type:
! CAUTION
! DANGER
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
Danger means that failure to follow this safety
warranty.
statement will result in severe personal injury or
death.
OUTDOOR UNITS
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
! WARNING
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
! CAUTION
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
Caution means that failure to follow this safety
This is considered normal. The condensation will
statement may result in minor or moderate
evaporate when the humidity drops.
personal injury, property or equipment damage.
! CAUTION
Environmental Requirements
Damages caused by ambient temperatures of
115 V UNITS
40°F (4°C) or below are not covered by the
This model is intended for indoor/interior applications only
warranty.
and is not to be used in installations that are open/
exposed to natural elements.
2
QUICK START GUIDE
u-line.com
Electrical
Water Hookup
INDOOR MODELS
! WARNING
PREPARE PLUMBING
Please use the braided stainless steel water supply line
SHOCK HAZARD — Electrical Grounding
which comes attached. The water line is fitted with a
Required. Never attempt to repair or perform
standard 1/4" (6.35 mm) compression fitting.
maintenance on the unit until the electricity has
been disconnected.
! WARNING
Never remove the round grounding prong from
the plug and never use a two-prong grounding
Prior to installation, determine if this product
adapter.
contains a gravity style drain or factory installed
drain pump. Products without a drain pump may
Altering, cutting or removing power cord,
only use a gravity style drain. Failure to connect
removing power plug, or direct wiring can cause
water supply or drain line connections properly
serious injury, fire, loss of property and/or life,
may result in water leakage, personal injury,
and will void the warranty.
and/or property damage. Disconnect power and
turn off water to the unit before attempting to
alter these connections. These connections are
Never use an extension cord to connect power to
the responsibility of the owner and must be
the unit.
connected per local plumbing code. If you are
uncertain of how to safely and properly install
Always keep your working area dry.
this product, contact a licensed plumber.
NOTICE
Water Supply Connection
Electrical installation must observe all state and
! CAUTION
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
Review, obey, and understand the local
that has been placed by a qualified electrician.
plumbing codes before you install your unit.
Connect to the cold water supply. The water
The unit requires a grounded and polarized 115 VAC,
pressure should be between 20 and 120 psi (138
60 Hz, 15A power supply (normal household current). An
and 827 kPa). The water line MUST have a shut-
individual, properly grounded branch circuit or circuit
off valve on the supply line.
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
3
QUICK START GUIDE
u-line.com
3. Locate braided stainless steel
! CAUTION
water supply line and connect
to your cold water supply. The
Do not use any plastic water supply line. The line
water line should be looped into
is under pressure at all times. Plastic may crack
2 coils. This will allow the unit
or rupture with age and cause damage to your
to be removed for cleaning and
home.
servicing. However, make
certain that the tubing is not
pinched or damaged during installation.
Do not use tape or joint compound when
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
4. Turn on water and check for leaks.
provides an adequate seal – other materials
could cause blockage of the valve.
5. Route water supply line in cable clamp and secure with
screw.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
! CAUTION
Turn off water supply and disconnect electrical
supply to unit prior to installation.
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Locate the desired cold water supply location.
4
QUICK START GUIDE
u-line.com
OUTDOOR MODELS
! CAUTION
PREPARE PLUMBING
The water valve uses a standard 1/4" (6.35 mm)
Do not use any plastic water supply line. The line
compression fitting. U-Line recommends using accessory
is under pressure at all times. Plastic may crack
water hook up kit – part # WATERHOOKUP. The kit
or rupture with age and cause damage to your
includes a 10' (3 m) braided flexible water supply line and
home.
a brass hose fitting. When using a 1/4" (6.35 mm) O.D.
soft copper supply line use the brass nut and sleeve
Do not use tape or joint compound when
included with the unit.
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
provides an adequate seal – other materials
! WARNING
could cause blockage of the valve.
Prior to installation, determine if this product
contains a gravity style drain or factory installed
Failure to follow recommendations and
drain pump. Products without a drain pump may
instructions may result in damage and/or harm,
only use a gravity style drain. Failure to connect
flooding or void the product warranty.
water supply or drain line connections properly
may result in water leakage, personal injury,
and/or property damage. Disconnect power and
! CAUTION
turn off water to the unit before attempting to
alter these connections. These connections are
Turn off water supply and disconnect electrical
the responsibility of the owner and must be
supply to unit prior to installation.
connected per local plumbing code. If you are
uncertain of how to safely and properly install
Use caution when handling back panel. The
this product, contact a licensed plumber.
edges could be sharp.
Water Supply Connection
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
! WARNING
Connect to potable water supply only.
2. Remove the grille/access panel in the front and the
back panel.
! CAUTION
Review, obey, and understand the local
plumbing codes before you install your unit.
Connect to the cold water supply. The water
pressure should be between 20 and 120 psi (138
and 827 kPa). The water line MUST have a shutoff valve on the supply line.
5
QUICK START GUIDE
u-line.com
8. Install retaining clip.
3. Locate water
valve in the front
of the unit and
thread water
supply line
through.
NOTICE
Route the water
supply line
through the unit
so it does not come into contact with any
internal components other than the solenoid
valve. Normal operation creates some vibration.
A water supply line contacting an internal
component or cabinet wall can cause excessive
noise during operation or damage to the line.
4. On the back panel,
break away filler feature
in bushing with flat
screwdriver.
Remove
ZLWKɠDW
screwdriver
5. Thread water line
through back panel hole
(with bushing).
6. Turn on water supply and check for leaks.
7. Reinstall back panel and grille/front access panel.
6
QUICK START GUIDE
u-line.com
Drain
GRAVITY DRAIN
Model numbers including “-00” or “-07” do not include a
factory installed drain pump.
Normal
Proper Drain
Model numbers including “-40” or “-47” include a factory
installed drain pump.
With Trap
Poor Drainage, Water Will Back Up
DRAIN CONNECTION
! CAUTION
With Trap and Vent
Proper Drain
If your U-Line unit did not come with a factory
installed drain pump you must use a gravity
A gravity drain may be used if:
style drain connection. For assistance in
Drain line has at least a 1" drop per 48" (approximately
determining if your unit has a pump please
2 cm drop per 100 cm) of run.
contact U-Line. The floor drain must be large
enough to accommodate drainage from all
attached drains. Follow these guidelines when
Drain line does not create traps and is vented per local
installing drain lines to prevent water from
code.
flowing back into the ice maker storage bin and/
or potentially flowing onto the floor, which may
1. Cut the pre-installed drain tube to length.
result in personal injury or property damage.
2. Connect to your local plumbing per the local code.
NOTICE
Drain can NOT be located directly below the unit.
3. If necessary, insulate drain line to prevent
Unit has a solid base that will not allow the unit
condensation.
to drain below itself.
There is a possibility that hose connections may
! CAUTION
have loosened during shipment.
Failure to connect water supply or drain line
Verify all connections and fittings are free from
connections properly can result in personal
leaks.
injury and property damage. Gravity drain
connections must be routed downward from the
rest of the unit at the rate of 1/4" per foot (1 cm
per 50 cm).
7
QUICK START GUIDE
u-line.com
FACTORY INSTALLED DRAIN PUMP
Y-Branch Tailpiece
P60 Pump Required
If your drain line will run up to a stand pipe, disposal or
Air Gap
(Optional Hook-Up)
spigot assembly, or does not otherwise meet the
requirements for a gravity drain, you may have ordered a
pre-installed U-Line P60 drain pump.
Waste
If you need to install a P60 drain pump into your unit, see
6KXW2ɞ
Valve
DRAIN PUMP section in the User Manual.
Hot
Water
See below for typical installations requiring a drain pump.
Cold
Water
NOTICE
Stand Pipe
P60 Pump Required
The maximum lift for the P60 drain pump is
10 feet. This must be done as close to the rear of
the unit as possible.
Waste
6KXW2ɞ
Valve
Hot
Water
Door Swing
Cold
Water
Wall
Wall
1/4" Min.
(6 mm)
2-1/8" Min.
(54 mm)
Waste
Disposal Assembly
P60 Pump Required
Air Gap
(Optional Hook-Up)
90°
Door Swing
Waste
Hot
Water
Cold
Water
90°
Door Swing
Units have a zero clearance for the door to open 90°,
when installed adjacent to cabinets.
6KXW2ɞ
Valve
Stainless Steel and black and white models require 2-1/8"
(54 mm) door clearance to accommodate the handle if
installed next to a wall.
Integrated models require 1/4" (6 mm) clearance if
installed next to a wall. Allow for additional space for any
knobs or pulls installed on the integrated panel/frame.
8
QUICK START GUIDE
u-line.com
General Installation
INSTALLATION
1. Plug in the power/electrical cord.
LEVELING INFORMATION
1. Use a level to
2. Gently push the unit into position. Be careful not to
confirm the unit is
entangle the cord or water and drain lines.
level. Level should
be placed along top
3. Re-check the leveling, from front to back and side to
edge and side edge
side. Make any necessary adjustments. The unit’s top
as shown.
surface should be approximately 1/8" (3 mm) below
the counter top.
1
4. Install the anti-tip bracket.
5. Remove interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.
2. If the unit is not level, adjust the legs on the corners of
the unit as necessary.
Integrated Panel Installation
1. Fully open door/drawer.
2. Starting at corner, pull
gasket away from door/
drawer.
Turn to Adjust
3. Continue to pull gasket
free from gasket channel.
3. Confirm the unit is level after each adjustment and
repeat the previous steps until the unit is level.
4. Upon removal, lay gasket
down on a flat surface.
INSTALLATION TIP
If the room floor is higher than the floor in the cutout
5. Partially loosen the 3 screws, securing the top hinge to
opening, adjust the rear legs to achieve a total unit rear
the cabinet.
height of 1/8" (3 mm) less than the opening’s rear height.
Shorten the unit height in the front by adjusting the front
legs. This allows the unit to be gently tipped into the
6. Align the panel with the outside edge (opposite the
opening. Readjust the front legs to level the unit after it is
hinge) and high enough to align with the highest point
correctly positioned in the opening.
in the door/drawer.
7. Insert panel underneath top hinge and apply upward
pressure while bringing the lower portion of the panel
flush to the door inside the lower hinge. The panel will
fit snuggly
9
QUICK START GUIDE
u-line.com
It is important to ensure that all drilled holes are
8. Align door with cabinet. Tighten the top 3 screws,
drilled to the correct depth in order to avoid
securing the top hinge to the cabinet.
splits in the wood when hardwood is installed.
11.Locate 6 of the #6x 1-1/4" (32 mm) screws provided
Align Top Of Panel With Highest Point Of Door/Drawer
with your unit.
12.Using a Phillips screwdriver, place one screw into each
Align Panel
Against
Door/Drawe
Edge First
of the 6 pilot holes and screw down. Do not overtighten
screws.
13.Be sure the screws force their way past the opening on
the gasket channel and sit flush against the bottom of
Due to differences in floor construction or
the channel.
surrounding cabinetry, the panel may not sit
flush with the top of the door/drawer.
Panel
Door
Integrated Panel
Integrated Panel
14.Remove clamps from door/drawer.
9. Secure integrated
panel to door/drawer
Bar
Clamp
If panel requires additional adjustment after
using clamps. A
removing clamps, slightly loosen each screw and
robust tape may also
adjust panel as necessary. Tighten screws upon
be used. U-Line
completion.
recommends the use
of bar clamps to
15.Starting at the corners, re-install the gasket into the
Door/Drawer
secure the panel to
the door/drawer. If
using tape, be
gasket channel in the frame. Make sure the gasket is
fully seated. This may take some force.
Wood
Panel
certain the tape will
not damage panel
finish upon removal.
10.Using a 7/64" (3 mm)
drill bit, drill 6 pilot
Bar
Clamp
holes into the wood
panel 1/2" (12 mm)
deep using the holes in the door/drawer frame as a
guide.
10
QUICK START GUIDE
u-line.com
Control Operation
Light Power Clean LED
Up Down
CONTROL FUNCTION GUIDE
FUNCTION
COMMAND
DISPLAY/OPTIONS
ON/OFF
Press
Unit will immediately turn ON or OFF.
Adjust ice thickness
See “Ice” section
View temperature in unit
Press
Toggle between F/C
Hold
Sabbath Mode
See “Sabbath Mode” section
and release
and
and
The display will flash and then toggle from set point
together and release
to temperature in unit.
for five seconds
The display will beep and display unit temperature.
Silent Mode (ice
production suspended for
Hold
and
Hold
for five seconds
Display will show “OFF”.
3 hours)
Clean Mode
First Use
Ice
All U-Line controls are preset at the factory. Initial startup
ICE CUBE THICKNESS ADJUSTMENT
requires no adjustments.
NOTICE
Ice thickness adjustment should only be made
NOTICE
one increment at a time. Allow ice maker
U-Line recommends discarding the ice produced
production to stabilize for 24 hours before
during the first two to three hours of operation
rechecking ice thickness.
to avoid possible dirt or scale that may dislodge
from the water line.
Ice is produced in layers resulting in a clear cube. Ice in
bin may develop surface frost which disappears when cube
is placed in liquid.
When plugged in, the unit will begin operating under the
factory default settings. If the unit was turned off during
installation, simply press
and the unit will immediately
switch on. To turn the unit off, press
Ice cubes in any given batch will vary, so it is necessary
and hold for
to choose cubes from the sample area for comparison
5 seconds and release.
when making adjustments.
11
QUICK START GUIDE
u-line.com
The ice cube thickness is factory set for best overall
Your clear ice machine is pre-set to produce ice between
performance. The factory setting is designed to maintain
the optimal dimensions illustrated below:
an ice bridge of approximately 1/16" to 1/8" (1.6 mm to
Cube Details
3.2 mm) under normal conditions, resulting in a dimple of
approximately 1/4" to 1/2" (6.4 mm to 12.7 mm) in
1/4" TO 1/2"
(6.4 mm to 12.7 mm)
DIMPLE
depth. A fuller cube with less of a dimple results in a
thicker ice bridge. As the ice bridge becomes thicker, the
1/16" TO 1/8"
(1.6 mm to 3.2 mm)
ICE BRIDGE
tendency for the cubes to stay together as a slab
increases. A bridge thicker than 1/8" (3.2 mm) may cause
cubes to overfill the ice bucket.
32 ice cubes are formed on a 4 x 8 slab during each cycle.
Each cycle takes approximately 15-20 minutes at the
default cube thickness (0).
Factory Default Setting - 0
THINNER BRIDGE
DEEPER DIMPLE
DIMPLES
THICKER BRIDGE
SHALLOWER DIMPLE
7/8"
(22 mm)
7/8"
(22 mm)
ICE BRIDGE
-5
SETTING
+5
SETTING
Ice thickness adjustments are made using the control
panel as follows:
1. To enter the thickness adjustment mode:
• Press and hold
for 5 seconds.
• The display will switch to “0” to confirm the
thickness adjustment mode has been selected.
The factory setting is “0,” and the total range of
adjustment is -5 to +5 (ideal range is -1 to +1). Use
raise the setting and thicken the ice bridge, or
to
to lower
the setting to thin the ice bridge.
Ice cubes in any given batch will vary, so it is necessary
to choose cubes from the sample area for comparison
when making adjustments.
12
QUICK START GUIDE
u-line.com
Warranty
U-LINE CORPORATION LIMITED WARRANTY
Sabbath Mode
1. U-Line Corporation (“U-Line”) warrants each U-Line
product to be free from defects in materials and
1
2
3
4
5
6
workmanship for a period of one year (two years on
7
Modular 3000 Series) from the date of installation.
U-Line further warrants the sealed system (consisting
of the compressor, condenser, evaporator, hot gas
bypass valve, dryer, and connecting tube) in each
U-Line product to be free from defects in materials and
Up
workmanship for a period of five years from the date of
Select
installation.
2. During the initial one-year warranty period (two years
on Modular 3000 Series) for all U-Line products U-Line
Down
shall: (1) repair any product or replace any part of a
U-Line Clear Ice Machine models are Star-K certified and
product; and (2) for all Marine, RV, and Domestic
can be used during the Sabbath. View a full list of Star-K
U-Line products sold and serviced in the United States
certified U-Line units at www.star-k.org.
(including Alaska and Hawaii) and Canada, U-Line
shall be responsible for the labor costs performed by a
U-Line authorized service company, incurred in
To prepare the unit for the Sabbath:
connection with the replacement of any defective part.
During years two through five of the warranty period
1. Press
and hold the until the unit turns off.
for the sealed system, U-Line shall: (1) at U-Line’s
option repair or replace any part of the sealed system;
and (2) for all Marine, RV, and Domestic U-Line
2. No new ice will form when the unit is off, but previously
products sold and serviced in the United States
made ice will still be accessible/present for over 24
(including Alaska and Hawaii) and Canada, U-Line shall
hours. Pump equipped models will continue to remove
be responsible for the labor costs incurred in
water as needed even if the unit is off.
connection with the replacement of any defective part
of the sealed system. All other charges, including
Sabbath Mode remains active until
is pressed again
transportation charges for replacements under this
and the unit turns on.
warranty and labor costs not specifically covered by
this warranty, shall be the responsibility of the
purchaser. This warranty extends only to the original
purchaser of the U-Line product. The Product
Registration Card included with the product should be
promptly completed by you and mailed back to U-Line,
or you can register on-line at www.u-line.com.
13
QUICK START GUIDE
u-line.com
7. If a product defect is discovered during the applicable
3. The warranty listed above does not apply to floor
display models. The warranty for these models shall
warranty period, you must promptly notify U-Line at
be one year from the date of installation. This one-year
1-800-779-2547 or the dealer from whom you
warranty does not apply to cosmetic damages. A proof
purchased the product. In no event shall such
of purchase may be required.
notification be received later than 30 days after the
expiration of the applicable warranty period. U-Line
may require that defective parts be returned, at your
4. The following conditions are excluded from this limited
expense, to U-Line’s factory in Milwaukee, Wisconsin,
warranty: use of cleaners other than the recommended
for inspection. Any action by you for breach of
stainless steel cleaners and U-Line Clear Ice Maker
warranty must be commenced within one year after
cleaner; installation charges; damages caused by
the applicable warranty period.
disasters or acts of God, such as fire, floods, wind, and
lightning; damages incurred or resulting from shipping,
8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL
improper installation, unauthorized modification, or
misuse/abuse of the product; customer education
OTHER WARRANTIES, EXPRESS OR IMPLIED,
calls; food loss and spoilage; door and water level
INCLUDING ANY IMPLIED WARRANTY OF
adjustments (except during the first 30 days from the
MERCHANTABILITY OR IMPLIED WARRANTY OF
date of installation); defrosting the product; adjusting
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH
the controls; door reversal; and cleaning the
ARE DISCLAIMED. U-Line’s sole liability, and your
condenser.
exclusive remedy, under this warranty is set forth in
the paragraphs above. U-Line shall have no liability
whatsoever for any incidental, consequential, or
5. U-Line products are designed to operate in ambient
special damages arising from the sale, use, or
temperatures between 50°F and 100°F unless
installation of the product or from any other cause
otherwise noted in the product manual. Exposure to
whatsoever, whether based on warranty (express or
temperatures outside this range may cause
implied) or otherwise based on contract, tort, or any
degradation of performance and issues, such as lower
other theory of liability.
ice production or spoiled contents, that are not
covered under the terms of this warranty as a result of
9. Some states do not allow limitations on how long an
that exposure. U-Line product may not be subjected to
temperatures below 40°F without following the
implied warranty lasts or the exclusion or limitation of
winterization and vacation shutdown procedures in the
incidental or consequential damages, so the above
user guide.
limitations may not apply to you. This warranty gives
you specific legal rights, and you may also have other
rights which vary from state to state.
6. U-Line’s Outdoor Limited Warranty, set forth in this
Paragraph 6 shall apply to U-Line models deemed
suitable for outdoor use by Underwriters Laboratory
(“UL”) as noted in the U-Line Product Catalog, U-Line’s
website, and/or on the serial tag located inside the
product. Outdoor product may come into contact with
rain by virtue of outdoor use. Exposure to other
sources of water shall also cause this warranty to be
void, including flooding of the area in proximity of the
unit greater than 1/8" deep in water, hurricanes,
splashing of pool water, or directing a spray from a
hose or similar device into and around the unit.
Copyright © 2016 U-Line Corporation. All Rights Reserved.
Publication Number 30441 8/2016 Rev.C
14
Download PDF

advertising