U-Line | U-3018CLRINT-00B | Quick Start Guide | U-Line U-3018CLRINT-00B Quick Start Guide

U-Line U-3018CLRINT-00B Quick Start Guide
QUICK START GUIDE
Modular 3000 Series
•
3018 CLR
•
115 V / 60 Hz
QUICK START GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations
of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American
leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine
use. U-Line’s complete product collection includes modular Wine Captain® Models, Beverage Centers, Clear Ice Machines,
Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, and Combo® Models.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin with a west coast office located in Laguna Beach,
California and European support in Dublin, Ireland. U-Line has shipped product to five continents for over two decades and is
proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance
Documentation, and Product Warranty information are all available for reference and download at u-line.com under
Documentation.
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.800.779.2547.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
SERVICE INFORMATION
Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our
Customer Care group directly, contact information below.
GENERAL INQUIRIES
SERVICE & PARTS ASSISTANCE
U-Line Corporation
Monday - Friday 8:00 am to 5:30 pm CST
8900 N. 55th Street
T: +1.800.779.2547
Milwaukee, Wisconsin 53223 USA
F: +1.414.354.5696
Monday - Friday 8:00 am to 4:30 pm CST
Service Email: onlineservice@u-line.com
T: +1.414.354.0300
Parts Email: onlineparts@u-line.com
F: +1.414.354.7905
Email: sales@u-line.com
u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
QUICK START GUIDE
Contents
1
Model List
2
Safety and Warning
2
Environmental Requirements
3
Electrical
3
Water Hookup
5
Drain
7
Door Swing
8
General Installation
8
Integrated Panel Installation
10
Control Quick Guide
10
First Use
10
Ice
12
Sabbath Mode
12
Warranty
u-line.com
QUICK START GUIDE
u-line.com
Model List
This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides
for all U-Line products.
Clear Ice Machines
U-3018CLRS-00B
U-3018CLRS-40B
U-3018CLRINT-00B
U-3018CLRINT-40B
Visit http://www.u-line.com/product-literature/userguides or scan this
QR code to view all user guides online.
1
QUICK START GUIDE
u-line.com
Safety and Warning
Environmental Requirements
NOTICE
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
Please read all instructions before installing,
exposed to natural elements.
operating, or servicing the appliance.
This unit is designed to operate between 50°F (10°C) and
Use this appliance for its intended purpose only and follow
100°F (38°C). Higher ambient temperatures may reduce
these general precautions with those listed throughout this
the unit’s ability to reach low temperatures and/or reduce
guide:
ice production on applicable models.
SAFETY ALERT DEFINITIONS
For best performance, keep the unit out of direct sunlight
Throughout this guide are safety items labeled with a
and away from heat generating equipment.
Danger, Warning or Caution based on the risk type:
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
! DANGER
This is considered normal. The condensation will
evaporate when the humidity drops.
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
! CAUTION
Damages caused by ambient temperatures of
! WARNING
40°F (4°C) or below are not covered by the
warranty.
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
! CAUTION
Caution means that failure to follow this safety
statement may result in minor or moderate
personal injury, property or equipment damage.
2
QUICK START GUIDE
u-line.com
Electrical
Water Hookup
PREPARE PLUMBING
! WARNING
Please use the braided stainless steel water supply line
which comes attached. The water line is fitted with a
SHOCK HAZARD — Electrical Grounding
standard 1/4" (6.35 mm) compression fitting.
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.
! WARNING
Never remove the round grounding prong from
Prior to installation, determine if this product
the plug and never use a two-prong grounding
contains a gravity style drain or factory installed
adapter.
drain pump. Products without a drain pump may
only use a gravity style drain. Failure to connect
Altering, cutting or removing power cord,
water supply or drain line connections properly
removing power plug, or direct wiring can cause
may result in water leakage, personal injury,
serious injury, fire, loss of property and/or life,
and/or property damage. Disconnect power and
and will void the warranty.
turn off water to the unit before attempting to
alter these connections. These connections are
the responsibility of the owner and must be
Never use an extension cord to connect power to
connected per local plumbing code. If you are
the unit.
uncertain of how to safely and properly install
this product, contact a licensed plumber.
Always keep your working area dry.
Water Supply Connection
NOTICE
! CAUTION
Electrical installation must observe all state and
local codes. This unit requires connection to a
Review, obey, and understand the local
grounded (three-prong), polarized receptacle
plumbing codes before you install your unit.
that has been placed by a qualified electrician.
Connect to the cold water supply. The water
pressure should be between 20 and 120 psi (138
The unit requires a grounded and polarized 115 VAC,
and 827 kPa). The water line MUST have a shut-
60 Hz, 15A power supply (normal household current). An
off valve on the supply line.
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
3
QUICK START GUIDE
u-line.com
4. Turn on water and check for leaks.
! CAUTION
5. Route water supply line in cable clamp and secure with
Do not use any plastic water supply line. The line
screw.
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
Do not use tape or joint compound when
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
provides an adequate seal – other materials
could cause blockage of the valve.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
! CAUTION
Turn off water supply and disconnect electrical
supply to unit prior to installation.
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Locate the desired cold water supply location.
3. Locate braided stainless steel
water supply line and connect
to your cold water supply. The
water line should be looped into
2 coils. This will allow the unit
to be removed for cleaning and
servicing. However, make
certain that the tubing is not
pinched or damaged during installation.
4
QUICK START GUIDE
u-line.com
Drain
GRAVITY DRAIN
Model numbers including “-00” or “-07” do not include a
factory installed drain pump.
Normal
Proper Drain
Model numbers including “-40” or “-47” include a factory
installed drain pump.
With Trap
Poor Drainage, Water Will Back Up
DRAIN CONNECTION
! CAUTION
With Trap and Vent
Proper Drain
If your U-Line unit did not come with a factory
installed drain pump you must use a gravity
A gravity drain may be used if:
style drain connection. For assistance in
Drain line has at least a 1" drop per 48" (approximately
determining if your unit has a pump please
2 cm drop per 100 cm) of run.
contact U-Line. The floor drain must be large
enough to accommodate drainage from all
attached drains. Follow these guidelines when
Drain line does not create traps and is vented per local
installing drain lines to prevent water from
code.
flowing back into the ice maker storage bin and/
or potentially flowing onto the floor, which may
1. Cut the pre-installed drain tube to length.
result in personal injury or property damage.
2. Connect to your local plumbing per the local code.
NOTICE
Drain can NOT be located directly below the unit.
3. If necessary, insulate drain line to prevent
Unit has a solid base that will not allow the unit
condensation.
to drain below itself.
There is a possibility that hose connections may
! CAUTION
have loosened during shipment.
Failure to connect water supply or drain line
Verify all connections and fittings are free from
connections properly can result in personal
leaks.
injury and property damage. Gravity drain
connections must be routed downward from the
rest of the unit at the rate of 1/4" per foot (1 cm
per 50 cm).
5
QUICK START GUIDE
u-line.com
FACTORY INSTALLED DRAIN PUMP
Y-Branch Tailpiece
P60 Pump Required
If your drain line will run up to a stand pipe, disposal or
Air Gap
(Optional Hook-Up)
spigot assembly, or does not otherwise meet the
requirements for a gravity drain, you may have ordered a
pre-installed U-Line P60 drain pump.
Waste
If you need to install a P60 drain pump into your unit, see
6KXW2ɞ
Valve
DRAIN PUMP section in the User Manual.
Hot
Water
See below for typical installations requiring a drain pump.
Cold
Water
NOTICE
Stand Pipe
P60 Pump Required
The maximum lift for the P60 drain pump is
10 feet. This must be done as close to the rear of
the unit as possible.
Waste
6KXW2ɞ
Valve
Hot
Water
Cold
Water
Waste
Disposal Assembly
P60 Pump Required
Air Gap
(Optional Hook-Up)
Waste
Hot
Water
Cold
Water
6KXW2ɞ
Valve
6
QUICK START GUIDE
u-line.com
Door Swing
Wall
For Integrated models that are installed adjacent to a wall,
1/4" (6 mm)
1/4" (6 mm) clearance is recommended from wall on
hinge side to allow the door to open 90°. Allow for
additional space for any knobs or pulls installed on the
integrated panel/frame.
Stainless Steel models that are installed adjacent to a wall
require 2-1/4" (57 mm) door clearance on hinge side to
allow for door handle.
Units have a zero clearance when installed adjacent to
90°
Door Swing
cabinets.
Space Required
For any Knobs or Pulls
Integrated
2-1/4" MIN
(57 mm MIN)
Wall
90°
Door Swing
Stainless
7
QUICK START GUIDE
u-line.com
General Installation
INSTALLATION
1. Plug in the power/electrical cord.
1. Use a level to confirm
the unit is level. Level
2. Gently push the unit into position. Be careful not to
should be placed along
top edge and side
entangle the cord or water and drain lines.
1
edge as shown.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit’s top
2. If the unit is not level,
surface should be approximately 1/8" (3 mm) below
remove grille and
adjust legs as
the countertop.
2
necessary. Use
included tool to adjust the height of the rear legs.
4. Install the anti-tip bracket.
5. Remove the interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.
Integrated Panel Installation
1. Fully open door.
Rotate Front Legs to Adjust
Rotate Clockwise to raise rear leg.
Rotate Counter-Clockwise to lower leg.
2. Starting at corner, pull
gasket away from door.
3. Confirm the unit is level after each adjustment and
repeat the previous steps until the unit is level.
3. Continue to pull gasket
free from gasket channel.
INSTALLATION TIP
If the room floor is higher than the floor in the cutout
4. Upon removal, lay gasket down on a flat surface.
opening, adjust the rear legs to achieve a total unit rear
height of 1/8" (3 mm) less than the opening’s rear height.
Shorten the unit height in the front by adjusting the front
5. The panel should be aligned with the outside edge
legs. This allows the unit to be gently tipped into the
(opposite the hinge) and high enough to align with the
opening. Adjust the front legs to level the unit after it is
highest point in the door.
correctly positioned in the opening.
Align Top Of Panel With Highest Point Of Door
Align Panel
Against
Door Edge
First
8
QUICK START GUIDE
u-line.com
10.Ensure the screws sit flush against the bottom of the
NOTICE
channel.
Due to differences in floor construction or
surrounding cabinetry, the panel may not sit
flush with the top of the door.
6. Secure integrated
panel to door using
Bar
Clamp
Integrated Panel
Integrated Panel
clamps. A robust
tape may also be
11.Remove clamps from door.
used. U-Line
recommends the
use of bar clamps
to secure the panel
to the door. If using
tape, be certain the
NOTICE
Door/Drawer
If panel requires additional adjustment after
Wood
Panel
removing clamps, slightly loosen each screw and
adjust panel as necessary. Tighten screws upon
tape will not
completion.
damage panel finish
upon removal.
12.Starting at the corners, re-install the gasket into the
7. Using a 7/64"
(3 mm) drill bit, drill
gasket channel in the frame. Make sure the gasket is
Bar
Clamp
fully seated.
6 pilot holes into
the wood panel 1/2"
(12 mm) deep using
the holes in the
door frame as a
guide.
NOTICE
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardwood is installed.
8. Locate 6 of the #6x 1-1/2" (38 mm) screws provided
with your unit.
9. Using a Phillips screwdriver, place one screw into each
of the 6 pilot holes and screw down. Do not overtighten
screws.
9
QUICK START GUIDE
u-line.com
Control Quick Guide
Actual Display:
Zone Toggle
Up
Select
ICE PRODUCTION
Power
U-Select Lighting
Down
Control Function Guide:
FUNCTION
COMMAND
DISPLAY/OPTIONS
OFF
Press
and hold
Display will count down from 5 to off
ON
Press
and release
Unit will come on immediately
Adjust lighting
Press
to adjust lighting
Press
or
to set low, medium or high
Customer menu
Press
and hold for 5 seconds
Press
or
to scroll through menu
Service menu
Press
or
Press
or
to scroll through menu.
and hold for 5 seconds
First Use
Ice
All U-Line controls are preset at the factory. Initial startup
ICE CUBE THICKNESS ADJUSTMENT
requires no adjustments.
NOTICE
Ice thickness adjustment should only be made
NOTICE
one increment at a time. Allow ice maker
U-Line recommends discarding the ice produced
production to stabilize for 24 hours before
during the first two to three hours of operation
rechecking ice thickness.
to avoid possible dirt or scale that may dislodge
from the water line.
Ice is produced in layers resulting in a clear cube. Ice in
bin may develop surface frost which disappears when cube
When plugged in, the unit will begin operating under the
is placed in liquid.
factory default setting. Follow the on screen prompt for
language selection and temperature units.
To turn the unit off, press
Ice cubes in any given batch will vary, so it is necessary
to choose cubes from the sample area for comparison
and hold for 5 seconds and
when making adjustments.
release. The display will show a countdown to switching the
unit off.
To power your unit on, simply press
immediately switch on.
and the unit will
10
QUICK START GUIDE
u-line.com
The ice cube thickness is factory set for best overall
performance. The factory setting “0” is designed to
THINNER BRIDGE
THICKER BRIDGE
maintain an ice bridge of approximately 1/16" to 1/8"
DEEPER DIMPLE
(1.6 mm to 3.2 mm) under normal conditions, resulting in
SHALLOWER DIMPLE
a dimple of approximately 1/4" to 1/2" (6.4 mm to
12.7 mm) in depth. A fuller cube with less of a dimple
results in a thicker ice bridge. As the ice bridge thickens,
the tendency for the cubes to stay together as a slab
increases. A bridge thicker than 1/8" (3.2 mm) may cause
cubes to overfill the ice bucket.
-5
SETTING
+5
SETTING
32 ice cubes are formed on a 4 x 8 slab during each cycle.
Each cycle takes approximately 15-20 minutes at the
ICE ADJUST
default cube thickness (0).
Up
Select
RETURN TO MENU
ICE ADJUST
ICE ADJUST = 0
DIMPLES
Down
7/8"
(22 mm)
Adjust ice thickness as follows:
7/8"
(22 mm)
ICE BRIDGE
1. Press
and
and hold for 5 seconds to enter the
Customer Menu.
Your clear ice machine is pre-set to produce ice between
the optimal dimensions illustrated below:
2. Press
to select “Ice Adjust”.
Cube Details
1/4" TO 1/2"
(6.4 mm to 12.7 mm)
DIMPLE
1/16" TO 1/8"
(1.6 mm to 3.2 mm)
ICE BRIDGE
3. Press
4. Press
. The selection will begin to flash.
to make the ice thicker or
thinner. Press
to make the ice
to confirm your choice.
The total range of adjustment is -5 (thinest) to +5
(thickest). If further adjustments are desired, repeat
Factory Default Setting - 0
Steps 1 through 4.
11
QUICK START GUIDE
u-line.com
Warranty
L
U-LINE CORPORATION LIMITED WARRANTY
Sabbath Mode
1. U-Line Corporation (“U-Line”) warrants each U-Line
product to be free from defects in materials and
1
2
3
4
5
6
workmanship for a period of one year (two years on
7
Modular 3000 Series) from the date of installation.
U-Line further warrants the sealed system (consisting
of the compressor, condenser, evaporator, hot gas
bypass valve, dryer, and connecting tube) in each
U-Line product to be free from defects in materials and
Up
workmanship for a period of five years from the date of
Select
installation.
2. During the initial one-year warranty period (two years
on Modular 3000 Series) for all U-Line products U-Line
Down
shall: (1) repair any product or replace any part of a
U-Line Clear Ice Machine models are Star-K certified and
product; and (2) for all Marine, RV, and Domestic
can be used during the Sabbath. View a full list of Star-K
U-Line products sold and serviced in the United States
certified U-Line units at www.star-k.org.
(including Alaska and Hawaii) and Canada, U-Line
shall be responsible for the labor costs performed by a
U-Line authorized service company, incurred in
To prepare the unit for the Sabbath:
connection with the replacement of any defective part.
During years two through five of the warranty period
1. Press
and hold the until the unit turns off.
for the sealed system, U-Line shall: (1) at U-Line’s
option repair or replace any part of the sealed system;
and (2) for all Marine, RV, and Domestic U-Line
2. No new ice will form when the unit is off, but previously
products sold and serviced in the United States
made ice will still be accessible/present for over 24
(including Alaska and Hawaii) and Canada, U-Line shall
hours. Pump equipped models will continue to remove
be responsible for the labor costs incurred in
water as needed even if the unit is off.
connection with the replacement of any defective part
of the sealed system. All other charges, including
Sabbath Mode remains active until
is pressed again
transportation charges for replacements under this
and the unit turns on.
warranty and labor costs not specifically covered by
this warranty, shall be the responsibility of the
purchaser. This warranty extends only to the original
purchaser of the U-Line product. The Product
Registration Card included with the product should be
promptly completed by you and mailed back to U-Line,
or you can register on-line at www.u-line.com.
3. The warranty listed above does not apply to floor
display models. The warranty for these models shall
be one year from the date of installation. This one-year
12
QUICK START GUIDE
u-line.com
warranty does not apply to cosmetic damages. A proof
1-800-779-2547 or the dealer from whom you
of purchase may be required.
purchased the product. In no event shall such
notification be received later than 30 days after the
expiration of the applicable warranty period. U-Line
4. The following conditions are excluded from this limited
may require that defective parts be returned, at your
warranty: use of cleaners other than the recommended
expense, to U-Line’s factory in Milwaukee, Wisconsin,
stainless steel cleaners and U-Line Clear Ice Maker
for inspection. Any action by you for breach of
cleaner; installation charges; damages caused by
warranty must be commenced within one year after
disasters or acts of God, such as fire, floods, wind, and
the applicable warranty period.
lightning; damages incurred or resulting from shipping,
improper installation, unauthorized modification, or
8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL
misuse/abuse of the product; customer education
calls; food loss and spoilage; door and water level
OTHER WARRANTIES, EXPRESS OR IMPLIED,
adjustments (except during the first 30 days from the
INCLUDING ANY IMPLIED WARRANTY OF
date of installation); defrosting the product; adjusting
MERCHANTABILITY OR IMPLIED WARRANTY OF
the controls; door reversal; and cleaning the
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH
condenser.
ARE DISCLAIMED. U-Line’s sole liability, and your
exclusive remedy, under this warranty is set forth in
the paragraphs above. U-Line shall have no liability
5. U-Line products are designed to operate in ambient
whatsoever for any incidental, consequential, or
temperatures between 50°F and 100°F unless
special damages arising from the sale, use, or
otherwise noted in the product manual. Exposure to
installation of the product or from any other cause
temperatures outside this range may cause
whatsoever, whether based on warranty (express or
degradation of performance and issues, such as lower
implied) or otherwise based on contract, tort, or any
ice production or spoiled contents, that are not
other theory of liability.
covered under the terms of this warranty as a result of
that exposure. U-Line product may not be subjected to
9. Some states do not allow limitations on how long an
temperatures below 40°F without following the
winterization and vacation shutdown procedures in the
implied warranty lasts or the exclusion or limitation of
user guide.
incidental or consequential damages, so the above
limitations may not apply to you. This warranty gives
you specific legal rights, and you may also have other
6. U-Line’s Outdoor Limited Warranty, set forth in this
rights which vary from state to state.
Paragraph 6 shall apply to U-Line models deemed
suitable for outdoor use by Underwriters Laboratory
(“UL”) as noted in the U-Line Product Catalog, U-Line’s
website, and/or on the serial tag located inside the
product. Outdoor product may come into contact with
rain by virtue of outdoor use. Exposure to other
sources of water shall also cause this warranty to be
void, including flooding of the area in proximity of the
unit greater than 1/8" deep in water, hurricanes,
splashing of pool water, or directing a spray from a
hose or similar device into and around the unit.
7. If a product defect is discovered during the applicable
warranty period, you must promptly notify U-Line at
Copyright © 2016 U-Line Corporation. All Rights Reserved.
Publication Number 30446 8/2016 Rev.A