Fulgor Milano | F6PGR304S2 | Weight and Dimensions | Fulgor Milano F6PGR304S2 Weight and Dimensions

30”-36” Full Gas Ranges 600 SERIES
Weight & Dimensions
30”
(76,3)
27 3/4”
9 1/4”
(23,6)
(70,6)
PACKAGING 30”
1”
GROSS WEIGHT
(2,6)
3”
(7,6)
DIMENSION
7”
(17,9)
C
min
48”
(122)
Minimum
to Combustibles
min
30”
(76,2)
PACKAGING 36”
max
13”
(33)
GROSS WEIGHT
To botton of
ventilation hood
DIMENSION
min 18”
(45,7)
min 18”
(45,7)
3”
(9)
2” (5,1) max.
protusion from wall
for gas or electrical supply
OPENING WIDTH
Range 30"
Range 36"
A&C
30" (76,2)
36" (91,4)
B
6" (15,2)
7" (17,8)
GAS
ELECTRIC
B
B
146 Kg
33"
45"3/4
32"1/4
840
1162
820
lb /
inch
Kg /
mm
377 lb
171 Kg
39"
45"3/4
32"1/4
990
1162
820
1 3/8”
3 3/8”
TO
(3,5)
(8,5)
*Suggested
location of
utilities
25-3/4”
(65,4)
27-1/2”
(69,8)
min
4 3/4”
(12,3)
48 1/8”
(122,2)
3” or 9 1/4”
(23,6) [OPTIONAL]
(7,6)
29-3/4”
35-3/4”
(75,8)
Note: Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and not certified.
Clearances to non-combustible materials must conform with local codes or, in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
(91,0)
Minimum clearances:
Above cooking surface (above 36” [91.4 cm])
• Sides - 6” (15.2 cm)
• Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum
18” (45.7 cm) above cooking surface
• Wall cabinets directly above product must be a minimum of 48” (122 cm) above cooking surface.
• Rear - 0” with 9 ” backguard; 0” with non-combustible rear wall.
Max 37-1/4”
Below cooking surface (36” [91.4 cm] and below)
• Install with zero clearance between adjacent combustible construction below the cooking surface and the back and sides of
the appliance
(94,7)
Min 35-3/8”
(89,8)
Max 37-1/4”
Max 38-1/2”
(97,7)
Min 36-3/8”
(92,5)
Back
(94,7)
Min 35-3/8”
(89,8)
Max 38-1/2”
(97,7)
Min 36-3/8”
(92,5)
min 2-½” (6,3)
min
min
3”
3”
(7,6)
322 lb
(1)
SHADED AREA:
The surface of the entire back wall above the range and below the hood
must be covered with a noncombustible material.
*Consult local code for exact location requirements.
ADDITIONAL CLEARANCES:
For island installation, maintain 2-½ in. minimum from
cutout to back edge of countertop and 3 in. minimum
from cutout to side edges of countertop (see top view).
For island installation, 12" (305) minimum clearance
back of range to combustible rear wall above countertop.
The island installation is not part of the ANSI Z21.1
scope and not certified.
W
D
H
Kg /
mm
3/8”
min
6”
(15,2)
A
min
6”
(15,2)
W
D
H
lb /
inch
(7,6)
27-1/2”
(69,8)
27-1/2”
(69,8)
3” or 9 1/4”
(23,6) [OPTIONAL]
(7,6)
Download PDF

advertising