DCS | RDV305L | Spec Sheet DCS Dual Fuel Range | DCS RDV305L Spec Sheet DCS Dual Fuel Range

dcsappliances.com
P. 888-936-7872
dcsappliances.ca
Dual Fuel Ranges Product Dimensions
RDU-48, RDU-36, RDU-30
RDV-48, RDV-36, RDV-30
RDU-48, RDV-48
Standard Installation:
Full Backguard Installation:
Island Installation:
using the appropriate range mount
Standard backguard model: BGRU2-1548,
BGRU2-1536, BGRU2-1530
using the appropriate wall mount Full
backguard model: BGRU-3048,
BGRU-3036, or BGRU-3030
using the integral island trim only
A
Hood
Hood
H
H
51" Min. to
combustibles
RDU-36, RDV-36
I
Hood
12" Min. to
combustibles ,
without backguard
51" Min. to
combustibles
51" Min. to
combustibles
1
I
B
D
C
D
D
A
E
0" Clearance
E
0" Clearance
0" Clearance
RDU-30, RDV-30
F
G
J
K
F
G
Important!
As defined in the "National Fuel Gas Code" (ANSI Z223.1, latest edition).
The horizontal surfaces of the cooktop trim must not be below countertop level.
If using the island trim only, a 12" clearance is
required between the back of the range and a
combustible surface (above the cooking surface).
If the clearance is less than 12", the back wall must
be non-combustible and made of heat-resistant
material.
A
Product Dimensions (inches)
RDU-48
RDV-48
RDU-36
RDV-36
RDU-30
RDV-30
A
Width of product
47 – 7/8"
35 – 7/8"
29 – 7/8"
B
Height of full backguard
1
26 – /
2"
1
26 – /
2"
1
26 – /
2"
C
Height of standard backguard
11 – 13⁄32"
11 – 13⁄32"
11 – 13⁄32"
1
1
D
Height of integral island trim
3 – /2"
3 – /2"
1
3–/
2"
E
Height of product (from floor to cooktop trim, excluding grates
and island trim)
min. 35 – 3/4"
max. 36 – 3/4"
min. 35 – 3/4"
max. 36 – 3/4"
min. 35 – 3/4"
max. 36 – 3/4"
F
Maximum depth from wall to front of product (including handle)
1
30 – /
4"
1
30 – /
4"
1
30 – /
4"
G
Maximum depth from wall to front of product with door open
46 – 11/16"
46 – 11/16"
46 – 11/16"
H
Maximum depth from wall to front of product (excl. handle and knobs)
29"
29"
29"
I
Depth of standard backguard
13⁄16"
13⁄16"
13⁄16"
I
Depth of full backguard
1 – 5⁄16"
1 – 5⁄16"
1 – 5⁄16"
J
Depth from wall to front of range side panel
25"
25"
25"
Depth of product from wall to oven door front (excl. handle)
1
27 – /
2"
1
27 – /
2"
1
27 – /
2"
1
K
Product dimensions and specifications are listed as a guide only. For complete installation instructions and specifications, refer to the product Use & Care Guide/Installation Instructions available at www.dcsappliances.com
dcsappliances.com
P. 888-936-7872
dcsappliances.ca
Dual Ruel Ranges Cabinetry Dimensions
RDU-48, RDU-36, RDU-30
RDV-48, RDV-36, RDV-30
A
E
B
D
Cook
ing Su
rface
C
H
C
Location of electrical and gas supply
see d
ia
follo grams
w
elec ing for
trica
la
conn
ectio nd gas
n de
tails
G
Final position of
range against wall
RD U, RDV
I
I
J
Electrical
and gas
F
K
Cabinetry Dimensions (inches)
RDU-48
RDV-48
RDU-36
RDV-36
RDU-30
RDV-30
A
Minimum width of ventilation hood installed above range
48"
36"
30"
B
Minimum vertical distance between countertop and cabinet extending above counter
18"
18"
18"
C
Minimum clearance from left and right edge of range to nearest vertical combustible surface
12"
12"
12"
D
Minimum clearance from cooking surface to:
- combustible surface centered above the cooking surface
- non-combustible surface centered above the cooking surface
51"
30"
51"
30"
51"
30"
E
Maximum overall depth of overhead cabinetry
13"
13"
13"
F
Width of cabinetry opening
48"
36"
30"
G
Maximum height from floor to countertop:
- with range levelling legs fully retracted
- with range levelling legs fully extended
35 – ¾"
36 – ¾"
35 – ¾"
36 – ¾"
35 – ¾"
36 – ¾"
H
Maximum depth from wall to cabinet front
25"
25"
25"
I
Distance from either edge of range to supply area
1 – ½"
1 – ½"
1 – ½"
J
Height of gas and electrical supply areas (from floor)
6"
6"
6"
K
Depth of supply areas (ie maximum protrusion of gas connection from wall)
2"
2"
2"
Product dimensions and specifications are listed as a guide only. For complete installation instructions and specifications, refer to the product Use & Care Guide/Installation Instructions available at www.dcsappliances.com
Download PDF