GE Monogram | ZW9000SJSS | Spec sheet | GE Monogram ZW9000SJSS Spec Sheet

GE Monogram® 30" Warming Drawer
ZW9000SJSS
OVERALL DIMENSIONS
30" (76.2)
25 19/32" (65)
1 3/32"
handle width
(2.8)
9 1/4"
10 1/2"
(23.5)
cutout height
SPECIFICATIONS
Overall Width
30" (76.2 cm)
Overall Height
10 1/2" (26.7 cm)
Overall Depth
23 1/4" (59.0 cm)
Drawer Capacity
1.90 cu. ft. (53.8 l)
Cut-out Width
28 1/2" (72.4 cm)
Cut-out Height
9 1/4" (23.5 cm)
Cut-out Depth
23 1/2" (59.7 cm)
Power Cord Length
56" (142.2 cm)
Electrical Rating
450W @ 120V/60Hz
Total Amps
15 Amps
Net Weight
59 lbs. (26.8 kg)
Approx. Shipping Weight
65 lbs. (29.6 kg)
(26.7)
28 1/2" (72.4)
5/8"
cutout width
(1.6)
FRONT VIEW (SHOWING CUTOUT OVERLAP)
27 15/16" (71.0)
23 1/4"
(59.0)
OPTIONAL ACCESSORIES
Custom Panel Kit
ZXD30B
Professional Panel Kit
ZXD9030P
ATTENTION ELECTRICIAN:
1 9/32"
(3.2)
2"
TOP VIEW
(5.1)
This appliance is supplied with a 56" (142.2 cm)
long electrical cord equipped with a 3-prong
(grounding) plug that mates to a standard
3-prong grounding wall outlet.
26 1/2" (67.3)
including handle
The electrical power cord is located on the right
side of the warming drawer. Locate the wall
outlet within easy reach of the electrical cord in
an adjacent cabinet, within 42" (106.7 cm) of the
right side or 16" (40.6 cm) from the left side of the
cut-out. A recessed outlet can be installed on the
right side of the cut-out, 7" (17.8 cm) max. from
the rear of the cabinet.
9"
(22.9)
DO NOT USE AN EXTENSION CORD
WITH THIS PRODUCT.
For more details refer to the installation instructions
for this product.
22" (55.9)
Dimensions in parentheses
are in centimeters unless
otherwise noted. Actual
product dimensions may
vary due to manufacturing
tolerances.
23 1/4" (59.0)
SIDE VIEW
Product Specification Created 9/14
GE Monogram® 30" Warming Drawer
ZW9000SJSS
INSTALLATION BELOW SINGLE OR DOUBLE WALL OVEN
NOTES
TOP VIEW
ZDT910SFSS
Side cleats
C
TOP VIEW
ZDT910SFSS
Side cleats
A
A W
arming drawers
are approved for
installation below
only certain specified
wall oven and cooktop
models. See the label
attached to the top of
the warming drawer for
approved combinations.
B A
dditional clearance
between cut-outs may
be required. Check to be
sure that oven supports
above the warming
drawer location do not
obstruct the required
interior 23-1/2" depth
and 9-1/4" height.
2" (5.1)
min.
D
B
9 1/4"
2" (5.1)(23.5)
cutout height
min.
9 1/4"
(23.5)
1"
(2.5)
min.
cutouttoe-kick
height
above
or adjust to
oven height
1" (2.5) min.
above toe-kick
or adjust to
oven height
28 1/2" (72.4)
min. cutout width
C
28 1/2" (72.4)
min. cutout width
23 1/2" (59.7)
min. cutout depth
23 1/2" (59.7)
min. cutout depth
SIDE VIEW
FRONT VIEW
SIDE VIEW
FRONT VIEW
5 1/2"
From top of countertop
to top of warming
5 1/2"
From top of countertop
to top of warming
drawer cutout
(14.0)
drawer cutout
INSTALLATION
BELOW
COOKTOP
min.
(14.0)
9 1/4"
min.
28 1/2" (72.4)
min. cutout width
(23.5)
cutout height
D
1" (2.5)
min.
(23.5)
above
cutouttoe-kick
height
or adjust to
cooktop height
9 1/4"
23 1/2" (59.7)
min. cutout depth
1" (2.5) min.
above toe-kick
or adjust to
cooktop height
23 1/2" (59.7)
min. cutout depth
E
28 1/2" (72.4)
min. cutout width
C
SIDE VIEW
FRONT VIEW
SIDE VIEW
FRONT VIEW
C I f you are installing in
frameless cabinets,
it may be necessary
to install 1/2" wide
cleats to accept drawer
mounting screws. See
drawer for mounting
screw locations.
D I nstall a 2"x2" or 2"x4"
Anti-tip block against
rear wall, 9" from floor
of cutout to bottom
of block. The anti-tip
block must be installed
to prevent the drawer
from tipping forward
when opened and
loaded. Failure to add
the anti-tip block could
result in personal injury.
E W
hen installing the
warming drawer
below a cooktop, a
solid barrier must be
installed at least 1"
from the lowest point of
the bottom of cooktop
burner box to the top
of the cut-out. Use any
solid material such as
1/4" thick plywood.
Allow at least 1/4"
air gap between the
barrier and the top of
the warming drawer.
For more details refer
to the installation
instructions for this
product.
Product Specification Created 9/14
GE Monogram® 30" Warming Drawer
ZW9000SJSS
INSTALLATION BELOW A CABINET DRAWER
NOTES
TOP VIEW
TOP VIEW
Side cleats
TOP VIEW
Side cleats
ZDT910SFSS
ZDT910SFSS
ZDT910SFSS
A
Side cleats
1/4"
(.6)
1/4"
min.
(.6)
min.
1/4"
B
9min.
1/4"
9(23.5)
1/4"
C
(.6)
Cut-out
(23.5)
height
9Cut-out
1/4"
height
(23.5)
Cut-out
1"
height
(2.5)
1"
min.
(2.5)
Above
min.
1"
toe-kick
Above
(2.5)
toe-kick
min.
Above
toe-kick
A I f you are installing in
frameless cabinets,
it may be necessary
to install 1/2" wide
cleats to accept drawer
mounting screws. See
drawer for mounting
screw locations.
23 1/2" (59.7)
23 cutout
1/2" (59.7)
min.
width
min. cutout width
23 1/2" (59.7)
min. cutout width
28 1/2" (72.4)
28 cutout
1/2" (72.4)
min.
width
min. cutout width
28 1/2" (72.4)
min. cutout width
B I nstall a 2"x2" or 2"x4"
anti-tip block against
rear wall, 9" from floor
of cutout to bottom
of block. The anti-tip
block must be installed
to prevent the drawer
from tipping forward
when opened and
loaded. Failure to add
the anti-tip block could
result in personal injury.
A
C W
hen installing the
warming drawer below
a cabinet drawer, a
solid barrier must be
installed at least above
the warming drawer
to block access. Use
any solid material such
as 1/4" thick plywood.
Allow at least 1/4"
air gap between the
barrier and the top of
the warming drawer.
Observe the 5" min.
above the floor or 1"
min. above the toe kick
installation height.
FRONT VIEW
FRONT VIEW
FRONT VIEW
SIDE VIEW
SIDE VIEW
SIDE VIEW
SIDE BY SIDE INSTALLATION
D
2" (5.1) min.
Between
2" (5.1)cut-outs
min.
Between cut-outs
2" (5.1) min.
Between cut-outs
2" (5.1)SUPPORT
x 4" (10.2)
PROVIDING CABINET
D W
hen installing two
warming drawers side
by side, install them
in separate cut-outs
and allow a 2" min. gap
between each cut-out.
INSTALLING ANTI-TIP BLOCKS
or2"
Equivalent
(5.1) x 4"Runners
(10.2)
or Equivalent Runners
2" (5.1) x 4" (10.2)
or Equivalent Runners
Install
2" (5.1)Install
x 4" (10.2)
or4" (10.2)
2" (5.1) xB
2" (5.1)
x 2" (5.1)
or
Install
Anti-tip
Block
2" (5.1)
(5.1)
2"against
(5.1)
2"
xx 4"
(10.2)
E
rear
cabinet
9" from
Anti-tip
Block
against
orwall
floor
to(5.1)
bottom
block
rear
from
2"cabinet
xwall
2"of9"
(5.1)
floor
to bottom
of block
Anti-tip
Block against
rear cabinet wall 9" from
floor to bottom of block
23 1/2"
23(59.7)
1/2"
(59.7)
23 1/2"
(59.7)
25" (63.5)
25"
30" (63.5)
(76.2)
30" (76.2)
25" (63.5)
30" (76.2)
2" (5.1) x 4" (10.2)
2" (5.1) xor4" (10.2)
2" (5.1) or
x 2" (5.1)
Runners
orxx
Solid
Bottom
2" (5.1)
(5.1)
2" (10.2)
(5.1)
2"
4"
Runners or or
Solid Bottom
2" (5.1) x 2" (5.1)
Runners or Solid Bottom
E T
he warming drawer
may be supported by
either a solid bottom or
2"x2" or 2"x4" runners.
The support must
be level and rigidly
mounted, flush with
the bottom edge of the
cut-out (there is no way
to level the drawer once
it has been installed,
so make sure that the
supports are level). The
floor or runners must be
capable of supporting
at least 150 lbs.
For more details refer
to the installation
instructions for this
product.
Product Specification Created 9/14
GE Monogram® 30" Warming Drawer
ZW9000SJSS
INSTALLATION WITH CUSTOM PANEL KIT - ZXD27B
NOTES
3/4" (1.9) max.
30" (76.2)
10 1/2"
1 13/16" (4.6)
(26.7)
Drill
5/16" (0.8)
through custom
panel for lamp jewel
1 3/4" (4.5)
CUSTOM PANEL PREPARATION
FRONT VIEW
CUSTOM PANEL
PREPARATION
SIDE VIEW
This kit contains a
mounting panel to support
a trim-less custom drawer
front up to 3/4" thick. The
original tubular handle
can be reinstalled onto the
custom panel with longer
screws (not provided) or
can be replaced with a
custom handle of your
choice (also not provided).
For more details refer
to the installation
instructions for this
product.
23 5/16" (59.2)
including handle
Excluding
custom panel
9"
Drawer
open
(22.9)
24" (61.0)
23 1/4" (59.0)
Excluding
custom panel
SIDE VIEW
Product Specification Created 9/14
GE Monogram® 30" Warming Drawer
ZW9000SJSS
INSTALLATION WITH PROFESSIONAL STYLE PANEL KIT - ZXD9030P
NOTES
30" (76.2)
26" (66.0)
2 1/4"
(5.7)
Handle width
9 1/4"
10 1/2"
(23.5)
Cutou-out height
(26.7)
28 1/2" (72.4)
5/8"
(1.6)
Cut-out width
This kit contains a
stainless steel professional
style panel with a handle
and lamp jewel imbedded
in the bottom right
side. This is a one-piece
assembly that replaces
the original drawer front
and tubular handle. The
original tubular handle
(or a custom handle)
cannot be installed onto
this professional drawer
panel. The 2XD9030P
kit is designed to fit
30" warming drawers
manufactured after
February 2015.
FRONT VIEW (SHOWING CUT-OUT OVERLAP)
27 15/16" (71.0)
23 1/4"
(59.0)
1"
(2.5)
1 11/32"
(3.4)
2 13/16"
TOP VIEW
(7.1)
27 13/32" (69.6)
Including Handle
9"
(22.9)
27 19/32" (70.1)
23 1/4" (59.0)
SIDE VIEW
Product Specification Created 9/14
GE Monogram® 30" Warming Drawer
ZW9000SJSS
FEATURES AND BENEFITS
Infinite Setting Temperature Control –
75 Degrees to 230 Degrees
Variable Humidity Control – Crisp to Moist
Removable Half Rack
1.9 cu. ft capacity
Accepts 3/4" trimless custom panel and custom
handle with trim kit
R
Full extension drawer on ball bearing glides
"On" indicator light
Accepts Optional Professional Panel Kit
Variable Installation Options
Hidden Controls Provide Flush Installation
Appearance
On/Off Rocker Switch
Product Specification Created 9/14
Download PDF