Dacor | DTO127W | Planning Guide | Dacor DTO127W Planning Guide

Dacor DTO127W Planning Guide
DTO, DTOV
Revised 04/15/14 Page 1/2
Document # PG01-013
Distinctive®
27” and 30” Wide
Single Wall Ovens
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
WARNING
Top of
chassis
K
B
Utility
cutout
J
PLANNING
GUIDE
•
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
•
This appliance must be installed in accordance with the
accompanying installation instructions.
F
G
H
C
D
A
Conduit:
60” (152 cm)
long
Control panel
front
E
Control panel
side view
1 1/8”
(2.9 cm)
3 1/2”
(8.9 cm)
21 7/8”
(55.6) cm
Top of
chassis
1 1/8”
(2.9 cm)
1 1/8”
(2.9 cm)
3 3/16”
(8.1 cm)
Model
(A) Overall
Width
(B) Chassis
Width
(C) Overall
Height
(D)* Chassis
Height
(E) Control
Panel
Overlay
DTO[V]127
26 7/8”
(68.3 cm)
25 3/8”
(64.5 cm)
27 3/4”
(70.5 cm)
26 5/8”
(67.6 cm)
1 1/8”
(2.9 cm)
DTO[V]130
29 7/8”
(75.9 cm)
28 3/8”
(72.1 cm)
27 3/4”
(70.5 cm)
26 5/8”
(67.6 cm)
1 1/8”
(2.9 cm)
(F) Utility
Cutout Width
(G) Utility
Cutout Height
(H) Utility
Cutout Depth
(J) Control
Panel Depth
(K) Notch
Depth
6 1/2”
(16.5 cm)
5”
(12.7 cm)
7 7/8”
(20.0 cm)
1 1/4”
(3.2 cm)
23 1/2”
(59.7 cm)
ELECTRICAL SPECIFICATIONS
Dedicated Circuit
Requirements
Total Connected Load
DTO[V]127
240 Vac 60 Hz., 4-wire,***
30 Amp.
240 Vac 60 Hz,
23.3 Amp., 5.6 kW
DTO[V]130
240 Vac 60 Hz., 4-wire,***
30 Amp.
240 Vac 60 Hz,
24.9 Amp., 6.0 kW
Model
Epicure
Millennia
(Order kit #AROVH30S)
Flush
Handle Dimensions
All specifications subject to change without notice.
*** Two 120 Vac hot (L1 and L2), one neutral, one ground
The above specifications are for reference only. See the appliance data
plate for exact specifications.
www.dacor.com
Phone: (800) 793-0093
DTO, DTOV
Revised 04/15/14 Page 2/2
Document # PG01-013
PLANNING
GUIDE
Distinctive 27” and 30” Wide
Single Wall Ovens
Cabinet/countertop tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
1“ (2.5 cm) min. to combustibles
1 1/2”
(3.8 cm)
typical counter
36” typ.
(91.4 cm)
R
P
Recommended
electrical
location
4” typical toe kick
3/4” (1.9 cm)
support platform
N
SINGLE WALL OVEN - INSTALLED UNDER COUNTER
Recommended
electrical
location
1” (2.5 cm) min.
to bottom of
cabinet door
Minimum Interior Cabinet Depth: 24” (61.0 cm)
Model
(N) Minimum
Cabinet
Width
(P) Cut Out Width
(R) Cutout Height
DTO[V]127
27”
(68.6 cm)
25 1/2” (64.8 cm)
minimum (recommended)
26 1/8” (66.4 cm)
maximum
26 3/4” (67.9 cm)
minimum (recommended)
27 1/2” (69.9 cm)
maximum
DTO[V]130
30”
(76.2 cm)
28 1/2” (72.4 cm)
minimum (recommended)
29 1/8” (74.0 cm)
maximum
26 3/4” (67.9 cm)
minimum (recommended)
27 1/2” (69.9 cm)
maximum
3/4” (1.9 cm)
support platform
R
P
1” (2.5 cm) min.
to top of
cabinet door
1“ (2.5 cm) min.
to combustible floor
Alternate
electrical
location
31 1/4” (79.4 cm)
recommended
4” typical toe kick
SINGLE WALL OVEN - CUTOUT DIMENSIONS
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093