AGA | ADC3GBRG | Specification Natural Gas Models | AGA ADC3GBRG Specification Natural Gas Models

AGA ADC3GBRG Specification   Natural Gas Models
AGA Dual Control 3-Oven Cast Iron Range – Natural Gas
Model # ADC3G
• Cast Iron Ovens use Natural Gas and
the Hotplates use Electric
• Three Cooking Modes –
Off, Slumber or On
ORDERING DETAILS
MODEL #
Black
ADC3G-BLK
• Cast iron radiant heat cooking
throughout each oven and both
hotplates providing 10 Cooking
Methods in one range
• The ovens are heated by a single
Heat Source giving gradual radiant
heat to bring solid cast iron up to
temperature
Claret
ADC3G-CLT
Cream
ADC3G-CRM
White
ADC3G-WHT
Pewter
ADC3G-PWT
• Three Large Capacity Multi-Function
Cast Iron Ovens – Roasting oven
(approx. 425°F-475°F), Baking oven
(approx. 325°F-375°F) and Slow Cook
oven (approx. 212°F-245°F)
• Ovens will heat to full temperature
in 8 hours from cold or 4 hours from
Slumber; Hotplates take under 11
minutes to reach full temperature
British Racing Green
ADC3G-BRG
Dark Blue
ADC3G-DBL
Pearl Ashes
ADC3G-PAS
Aubergine
ADC3G-AUB
• Hotplates operate independent from
the ovens and separate from each
other
Duck Egg Blue
ADC3G-DEB
Heather
ADC3G-HEA
Pistachio
ADC3G-PIS
• External fan assisted power venting
Aqua
ADC3G-AQU
Lemon
ADC3G-LEM
Rose
ADC3G-ROS
• Two 14½” diameter Cast Iron
Hotplates – Boiling hotplate (626°F)
and Simmering hotplate (392°F) can
accommodate extra-large pans or
may be used as a griddle cooking
surface
Cast iron range is coated in hygienic, easy-to-clean vitreous enamel and is available in 15 colors
Heather
Aubergine
White
Aqua
Rose
Duck Egg Blue
Pistachio
Dark Blue
Pewter
Cream
Pearl Ashes
Claret
British
Racing Green
Lemon
Black
1
AGA Dual Control 3-Oven Cast Iron Range – Natural Gas
Model # ADC3G
B
S
Height
35⅞"
C
Depth
27½
1
2
3
Technical Specifications
Overall Dimensions
35⅞"H x 38⅞"W x 27½"D
1. Roasting Oven
9⅝"H x 13⅝"W x 18¾"D
2. Baking Oven
9⅝"H x 13⅝"W x 18¾"D
3. Slow Cook Oven
9⅝"H x 13⅝"W x 18¾"D
B. Boiling Plate
14½" Dia
S. Simmering Plate
14½" Dia
C. Control Panel
Weight
816 lbs
Shipping Weight
1135 lbs
Electrical
Requirements
Width 38⅞"
Fuel/Power
Complimentary Cookware Included
• (1) 13" x 18" Large
Enameled Roasting
Pan with Broiling Rack
• (1) 12 ½" x 13 ½" Half
Size Enameled Roasting
Pan with Broiling Rack
Vent Options
• (2) 18 ¾" x 13 ½"
Floor Grids
• (1) Cold Plain Shelf
• (3) 17" x 13 ½" Oven
Grid Shelves
• (1) Wire Brush
• (1) Hotplate Toaster
9⅝"H x 13⅝"W
Warranty
240v, 40amp, 60Hz
Natural Gas Ovens, Electric
Hotplates
External venting flue
5 Year Limited Warranty
1 Year Labor
Shipping Instruction
Ships fully assembled
AGA Kitchen Concierge
1.800.525.5601
B. BOILING PLATE
S. SIMMERING PLATE
CAST IRON EVIDENCE
Acclaimed as one of the most
perfect mediums for great
cooking because it retains heat
well, has even heat distribution
and radiates a gentle heat
aiding food in flavor retention
1. ROASTING
OVEN
and succulence.
Cast iron cooking means ease of cleaning because
oven splashes and spills are carbonized and simply
require wiping out. An AGA also means fewer
intrusive cooking smells.
The cast iron AGA is made from 70% recycled
material and is itself 95% recyclable. Inside every
new AGA is a bit of an old one
INSULATED COVERS
The distinctive hallmark
of the AGA, the highly polished
stainless steel insulated covers
are brought down over the
hotplates to help contain the heat when on and
protect the hotplate when off.
C.
2. BAKING
OVEN
3. SLOW
COOK OVEN
CONTROL PANEL
2
AGA Dual Control 3-Oven Cast Iron Range – Natural Gas
Model # ADC3G
Installation
NATURAL GAS
MAXIMUM HEAT
INPUT
6,800 Btu/hr
Thermostat Bypass
70
Main Burner Injector
112
Gas Supervision Injector
4212
Inlet Pressure
8” w.g.
Burner Pressure
4” w.g.
A
B
C
D
E
F
G
H
J
K
L
M
N
p
Q
R
mm
987
948
910
680
1388
756
1145
698
116
10
565
689
43
118
55
634
ins
38⅞
37�/8
35⅞
26¾
54⅝
29¾
45⅛
27½
4⅝
�/8
22¼
27⅛
1¾
4⅝
2⅛
25
Range Dimensions
When surveying for a range installation the actual clearance required
for the ‘body’ of the appliance should be increased by ⅜" (10mm)
beyond the figures quoted above. This allows safe margin to take into
account the natural dimensional variations found in major castings. In
particular the width across the appliance recess could be critical.
Range Base or Hearth
It is essential that the base or hearth on which the range stands should
be level. The base of the built-in AGA plinth must be level and sit above
finished floor height for service access.
Plinth
The front plinth cover is removable and must not be obstructed by
flooring or tiles. If necessary the range must be raised by the thickness of
the tiles to ensure the plinth can be removed.
Minimum Clearance to Combustibles
A gap of at least ½" must be observed between the rear of the top plate,
and the wall behind the appliance. If the rear wall is of combustible
material there must be a gap of 1" (25mm).
Side Clearances
A ⅛" (3mm) gap is required each side between the range top
plate and adjoining work surfaces that may be fitted, this is
to allow for the safe removal of the top plate should this be
required at a later date.
Where ranges are fitted against side walls a 4 9/16" (116mm)
side clearance is required on the right and left hand side for
oven doors access.
If the AGA is to be installed in a brick recess, then the minimum
clearance should be increased by at least ⅜" (10mm), to allow
for the walls not being square.
In addition a minimum clearance of 39½" (1000mm) must be
available at the front of the range to enable it to be serviced.
Range Hoods
It is recommended this AGA is fitted with a range hood. The
AGA venting system is located on top of the AGA between the
two hotplates, and is designed for venting the moisture from
the ovens. The range hood should be positioned not less than
the minimum height as recommended by the manufacturer,
from the top of the AGA.
Specifications are subject to change without notice. Visit www.aga-ranges.com for the most up-to-date information.
3
AGA Dual Control 3-Oven Cast Iron Range – Natural Gas
Model # ADC3G
External Venting
157 1/2”
(4m) MAX.
157 1/2”
(4m) MAX.
11 3/4”
(300mm)
MAX.
11 3/4”
(300mm)
MAX.
157 1/2”
(4m) MAX.
157 1/2”
(4m) MAX.
DOWNWARD RUNS UP TO 11 3/4”(300mm) BELOW THE APPLIANCE ARE ALLOWED, PROVIDED ONLY
ONE BEND IS USED.
Fig. 9
DOWNWARD RUNS USING 2 BENDS ARE NOT ALLOWED.
Minimum
inch (mm)
Position Spacing
A Directly below an openable
window, air vent, or any other
ventilation opening
B Below gutter, drain/soil pipe
11¾" (300)
3" (75)
C Below eaves
7⅞" (200)
D Below a balcony or car port roof
7⅞" (200)
E From vertical drain pipes
and soil pipes
5⅞" (150)
F From internal or external corners
11¾" (300)
GA
bove adjacent ground
or balcony level
11¾" (300)
H From surface facing the terminal
23⅝" (600)
I Facing terminals
47¼"
(1200)
J From opening (door/window)
in car port into dwelling
47¼"
(1200)
K Vertical from a terminal
59" (1500)
A Horizontally from a terminal
11¾" (300)
DOWNWARD RUNS UP TO 11 3/4”(300mm) BELOW THE APPLIANCE ARE ALLOWED, PROVIDED ONLY
ONE BEND IS USED.
RUNS USING 2 BENDS ARE NOT ALLOWED.
FlueDOWNWARD
System
The flue system must be installed in
accordance with the federal, state and
local codes.
Fig. 11
18
Products of combustion discharge
is by a
fan powered flue pipe of 2" (50m diameter
Fig. 11
which can reach up to 13’ (4 metres)
in
18
length through a maximum of 4 x 90°
bend. Exits from the appliance can be from
rear, LH or RH sides. (See Figs. 8 and 9).
The flue pipe should protrude through
the outside wall fixing plate by 1” (25mm)
(See Fig. 6).
Terminal Position
The minimum acceptable spacings from
the terminal to obstructions and ventilation
openings are as shown in Fig. 7.
Where the terminal is fitted within 23
⅝" (600mm) below plastic guttering an
aluminium shield 39 ⅜” (1000mm) long
should be fitted to the underside and
DESN 516849
immediately
beneath the guttering or
eaves.
DESN 516849
Where the terminal is fitted within 17 ¾"
(450mm) below eaves or painted guttering
an aluminium shield 29 1/2 (750mm) long
should be fitted to the underside and
immediately beneath the guttering or
eaves.
Terminal Protection
A terminal guard is supplied with the range
and must be fitted, if flue termination is
less than 78 ¾" (2 metres) above ground
level, or subject to damage.
When fitted, it must be positioned to
provide a minimum of 2" (50mm) clearance
from any part of the terminal and be
central over the terminal.
Specifications are subject to change without notice. Visit www.aga-ranges.com for the most up-to-date information.
4
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising