Miele | 23670552USA | Specs | Miele 23670552USA Specs

ContourLine Plumbed
Combi-Steam Oven
DGC 6705 XL
8mieleusa.com
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
DGC 6705 XL
Features:
• M Touch innovative and revolutionary
controls are both easy-to-operate and
navigate. An intuitive swipe of the
screen will quickly lead you to your
desired selection
• MultiSteam technology delivers
powerful steam generation and
optimum steam distribution via 6 inlet
ports
• Plumbed water supply and drainage
• Wired roast probe for perfect roasting
• 3-in-1 appliance
• True European convection oven
• Steam oven
• Combination of steam and
convection oven
• MasterChef and MasterChef Gourmet
menus offer over 150 food types to
cook to perfection
• XL stainless steel cavity
• Lift up control panel conceals water
and condensate container (both
containers are dishwasher-safe)
• ComfortSwivel handle moves with the
motion of your wrist, creating a more
ergonomic feel when opening and
closing the oven door
DGC 6705 XL
Page 2 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
SPECIFICATIONS
DGC 6705 XL — Item 23670552USA
Overall Unit Width - Excluding Fascia Dimension
219/16” (548mm)
Overall Height - Excluding Fascia Dimension
1711/16” (449mm)
Overall Unit Depth - Excluding Fascia Dimension
215/8” (550mm)
Oven Door Clearance
13” (330mm)
Depth with door open
3411/16” (898mm)
Overall Fascia Dimensions
237/16” (595mm) W x 18” (455.5mm) H
x 7/8” (22mm) D
Built-In
Minimum Cabinet Width
221/16” — 223/8” (560 - 568mm)
Minimum Cabinet Depth
217/8” (555mm)
Minimum Cabinet Opening Height
1711/16” — 1713/16” (450 — 452mm)
Minimum Base Support
60 lbs
Additional Cut-outs Required
Venting and plumbing cut-out required
1911/16” x 19/16” (500 x 40 mm)
Plumbing
Water Supply Requirements
Connect to a cold water supply only. Must
be connected to a shut-off valve. The water
shut-off valve must be accessible after
installation. The water pressure must be
between 14.5 psi (1 bar) and may not
exceed 87.02 psi (6 bar). If the pressure is
higher than 87.02 psi (6 bar), a pressure
reducing valve must be installed. The
supplied hose has a length of 59” (1500mm).
The hose must not be shortened. The entire
hose length must not exceed 24’7” (7.5m).
Drainage Requirements
Drain hose loop may be positioned at or
above the flood level of the sink or drain
board to which it is connect to provide the
proper air gap. The top of end the drain hose
must not be higher than 1911/16” (500mm) to
where it connects to the drain trap. The drain
hose must not be shortened. The entire hose
length must not exceed 24’7” (7.5m). See
installation manual for additional
information.
Plumbed Hose Connection
Supplied hose: flexible braided 4’11”
(1.5m) with 3/8” O.D. fitting for connection to
a shut off valve
Electrical
Electrical Requirements
240V 60Hz 20A
Power Cord
Molded plug - NEMA 6-20, 240V power cord
Cut out for power cord
Minimum 3” square
Electrical Rating
2.7kW (240V)
Total Amps
11.25A on 240V
Shipping
Shipping Weight
65 lbs
Shipping Dimensions
267/32” (666mm) W x 215/8”(549mm) H x
231/16” (535mm) L
Support
Call
800.843.7231
20/20
82020technologies.com
DGC 6705 XL
Page 3 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
PRODUCT VIEWS
Isometric View
Front View
DGC 6705 XL
Page 4 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
PRODUCT VIEWS
Top View, Door Open
Side View
DGC 6705 XL
Page 5 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
INSTALLATION SPECIFICATIONS
Front Dimension Details
Control Panel Swivel Range
DGC 6705 XL
Page 6 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
INSTALLATION SPECIFICATIONS
Water Intake / Drain Connection
DGC 6705 XL
Page 7 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
INSTALLATION SPECIFICATIONS
Wall Cabinet Installation
DGC 6705 XL
Page 8 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
INSTALLATION SPECIFICATIONS
Wall Cabinet Installation —
Cut-outs for venting the appliance and
routing of the water hoses
DGC 6705 XL
Page 9 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
INSTALLATION SPECIFICATIONS
Under Counter Installation
DGC 6705 XL
Page 10 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
INSTALLATION SPECIFICATIONS
Under Counter Installation —
cut-outs for venting the appliance
and routing of the water hoses
DGC 6705 XL
Page 11 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
INSTALLATION SPECIFICATIONS
Installation in Combination with an Oven
DGC 6705 XL
Page 12 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
INSTALLATION SPECIFICATIONS
Installation in Combination with an Oven
— cut-outs fot venting the appliances and
routing of the water hoses
DGC 6705 XL
Page 13 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
INSTALLATION SPECIFICATIONS
Installation in Combination with ESW 6X14
DGC 6705 XL
Page 14 of 15
ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
FOREVER BETTER
INSTALLATION SPECIFICATIONS
Installation in Combination with an Oven
— cut-outs fot venting the appliances and
routing of the water hoses
DGC 6705 XL
Page 15 of 15
Download PDF