Installation Requirements Models 8200/8210
(page 1 of 2)
Due to continuing product improvements, Heartland Appliances reserves the right to amend specificaHelp Desk
tions without notice. Please contact Heartland for the most up to date information, as it applies to product
877-650-5775
being purchased, or download latest Site Preparation Specifications from www.heartlandapp.com.
APPLIANCE REQUIREMENTS
VENTING REQUIREMENTS
How-to Steps
Appliance Clearances (see Page 2 for additional details):
• Sides of stove to adjacent surfaces: 1/2” (1.5 cm) min
• Nickel trim to adjacent surfaces: 0” right and left
• Rear clearance: 0”
• Closet right side to cabinetry: 0”
• Top of counter to underside adjacent cabinetry: 18” (46
cm)
• Cooktop to underside overhead cabinets: 30-1/4” (77 cm)
• Edge of range to combustible wall on either side: 6” (15 cm)
• Cut out width for range’s main body: 30” (76 cm)
• Max. countertop depth: 24” (61 cm); height: 36” (91 cm)
• Max. overhead cabinet depth: 13” (33 cm)
• Note: If unit is installed beside a refrigerator it is important
that there be at least 5" (13 cm) between the refrigerator
and range for proper air circulation.
Electrical
Electrical hookup must be performed by a licenced
electrician
• 240 Volts 60Hz 11 Kw.
• 5 ft (1.5 m) power cord included with either 3 or 4 prong
plug (please specify at time of order placement).
• Stove must be electrically grounded in compliance with
local codes. In the absence of local codes, with the
National Electrical code ANSI/NFPA 70 “Latest Edition”
in the US or in Canada with the Canadian Electrical
Code, Part I, CSA Standard C22, or the Local National
Electrical Code.
How-to Steps
Option 1 - Ventless
installation:
• Requires no further
set up (cooking
fumes are drawn
through pre-installed
filters and exhausted
through rear of hood,
back into the room.
Option 2 - Venting directly outside:
• Method 1 - Installation through outside wall.
• Method 2 - Installation through attic to outside.
3 1/4" x 10"
Exhaust
adaptor
included
with range
•
Method 1
Method 2
Safety
Maximum ducting run: 25 linear feet - subtract 5'
per 90 deg elbow and 2.5' per 45 deg elbow. Do
not use more than two elbows. All duct work
must be metal. Do not use plastic duct. range
hood should never be exhausted into a wall
cavity or an attic where an accumulation of
grease could become a fire hazard.
• Installation must be completed in accordance
with all local &national codes.
• To eliminate risk of burns or fire, installation of
cabinet storage space above range should be
avoided. Existing cabinets min clearance 30-1/
4” (76 cm) .
• Use only materials which conform to local codes
in effect.
• Gas cooking appliances produce heat and
moisture - ensure kitchen is well ventilated.
Prolonged intensive use may require additional
ventilation (opening windows or addition of
supplemetary air exhaust sources).
•
#02023
12-07-2006
7
© 2005 HEARTLAND APPLIANCES INC.
Heartland Appliances Inc. 1050 Fountain St North, Cambridge, ON, N3H 4R7
Installation Requirements Models 8200/8210
(page 2 of 2)
Due to continuing product improvements, Heartland Appliances reserves the right to amend specificaHelp Desk
tions without notice. Please contact Heartland for the most up to date information, as it applies to product
877-650-5775
being purchased, or download latest Site Preparation Specifications from www.heartlandapp.com.
Range Hood Outlet
Dimensions
27.5”
(70 cm)
3-7/8”
(10 cm)
3 1/4"x 10"
8.3 cm x 25.4 cm
13 3/4"
35 cm
11-3/8”
(29 cm)
14”
(36 cm)
56"
142.2 cm
29-1/2”
(75 cm)
62-3/8”
(159 cm)
66 1/4"
168.3 cm
36-1/8”
(92 cm)
62 3/8"
159 cm
36 1/8"
92 cm
29-3/4”
(76 cm)
28”
(72 cm)
43-3/4”
(111 cm)
with oven
door open
0” clearance
to the back
3” (7.6 cm)
52”
(132 cm)
with bottom drawer fully open
29 3/4"
76 cm
Rough In
Range Hood Outlet 3-1/2” x 10-1/2”
( 8.9 x 26.7 cm )
13-3/4”
(6” clearance to any
combustible wall)
0
(35 cm)
13” (33 cm)
66 3/4”
cabinet depth
(169.5 cm)
with std cresting 56”
6” (16 cm)
(142 cm)
62 7/8”
24”
(160 cm)
(61 cm)
without cresting
30-1/4”
(77 cm)
0
counter
depth
12”
(30.5 cm)
Receptacle Location
(use flush mounting
juction box)
0
Min 18”
(46 cm)
36”
(91 cm)
5”
(13 cm)
#02023
12-07-2006
8