Miele PT7135C Installation Plan

Miele PT7135C Installation Plan
Installationsplan / Installation plan
Installatietekening
Plano de instalación
Plan d`installation
Plano de instalação
Piano di installazione Σχέδιο εγκατάστασης
Asennusohje
Installasjonsplan
Installationsplan
G
PT 7135 C / PT 5135 C EL
Materialnummer
Änderungsstand
Datum Zeichnung
Datum Legende
/
/
/
/
Mat. no.:
Version:
Drawing date:
Legend date:
06 664 250
01
25.04.2005
31.05.2005
Technical datasheet
PT 7135 C / PT 5135 C
Electric (EL)
Tumble dryers:
Heating:
Legend:
Circled, bold-type abbreviations:
Connection required
G
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Optional extras:
UM
BS
Miele plinth
UG/UO 5005
(UG = Box plinth/UO = Open plinth)
Height Model
Width UG (UO)
Depth UG (UO)
mm
mm
mm
300
609
622
mm
mm
mm
mm
300
100
600
650
1. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Length of supply lead (H07 RN-F without plug)
(supplied)
V
Hz
kW
A
mm²
mm
2N AC 400
50
3.68
2 × 10
4 × 1.5
2000
1. Alternative voltage
Frequency
Rated load
Fuse rating
Supply lead as above
V
Hz
kW
A
3 AC 230
50
3.68
3 × 16
V
Hz
kW
A
mm²
mm
1N AC 230
50
3.68
1 × 16
3 × 1.5
2000
V
Hz
kW
A
1N AC 230
50
2.15
1 × 10
V
Hz
kW
A
mm²
mm
1N AC 220-230
50
2.7 – 2.95
1 × 13
3 × 1.5
2000
Concrete platform Concrete platform optional (Min. quality B15)
Recommended height
Minimum height
Recommended width
Recommended depth
Ensure good anchorage!
(598)
(615)
2. Alternative voltage
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Length of supply lead (H05 RN-F without plug)
(supplied)
3. Alternative voltage
Frequency
Rated load
Fuse rating
Supply lead as above
convertible
D
convertible
Electrical
connection
convertible
Machine connections:
Country variations:
G i
2. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Length of supply lead (H05 RN-F with plug)
(supplied)
Installationsplan PT 7135 C / PT 5135 C EL
Stand: 31.05.2005
Seite 8
j S
3. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Length of supply lead (H05 RN-F without plug)
(supplied)
V
Hz
kW
A
mm²
mm
2N AC 400
50
3.68
2 × 10
4 × 1.5
2000
N
4. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Length of supply lead (H05 RN-F without plug)
(supplied)
V
Hz
kW
A
mm²
mm
1N AC 230
50
3.68
1 × 16
3 × 1.5
2000
W
5. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Length of supply lead (H05 RN-F with plug)
(supplied)
V
Hz
kW
A
mm²
mm
1N AC 230-240
50
2.15 – 2.35
1 × 10
3 × 1.0
2000
J
6. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Length of supply lead (H05 RN-F with plug)
(supplied)
V
Hz
kW
A
mm²
mm
2N AC 200
50-60
2.85
2 × 20
3 × 2.75
2000
Condensate drain Max. temperature
hose
Drain hose (Int. dia. × wall thickness × l) [DN 10]
Hose sleeve for drain hose to be provided on site (ext. dia. x l)
Max. transient throughput
Max. head height (measured from base of unit)
°C
mm
mm
l/min
mm
60
10 × 2.5 × 2000
10 × 30
3
1000
Fittings (supplied) Miele plinth UG/UO 5005
4 × metal angled brackets (to secure machine to plinth)
4 × screws DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
mm
mm
8 × 65
12 × 60
mm
mm
6 × 50
8 × 40
Plug and socket connection in accordance with IEC 60309
recommended to facilitate electrical safety tests.
Install mains isolator according to IEC 60947 on hard-wired
connection.
Wall socket or mains isolator must be accessible after
installation.
The use of an earth leakage circuit breaker (ELCB) is strongly
recommended.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Cold air intake
Unobstructed vent required for cold air
Cold air
discharge vent
Unobstructed vent required for cold air
On concrete platform
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
Installationsplan PT 7135 C / PT 5135 C EL
Stand: 31.05.2005
Seite 9
Without plinth
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
mm
mm
6 × 50
8 × 40
mm
mm
mm
mm
mm
kg
N
W
595
700
850
600 x 900
1100
60
~ 670
2.500
dB (A)
dB (A)
68
approx. 55
Payment system
Possible
extensions
Machine data
The following extensions are possible:
Installation of payment system
Installation as washer-dryer stack
Connection to serial interface, RS 232
Width
Depth
Height
Knocked-down dimensions (W × H)
Recommended rear wall gap (measured to front of machine)
Net weight
Dynamic floor load, max.
Average heat dissipation
(dependent on ambient room temperature and programme
selected)
Acoustic power level (re1 pW)
Sound pressure level
(measured at a distance of 1 m from the machine and at a
height of 1.6 m)
Installation should only be carried out by authorised fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved! Measurements in mm
Installationsplan PT 7135 C / PT 5135 C EL
Stand: 31.05.2005
Seite 10