QUICK START
GUIDE
DYWS4 Wine Dispensing System
WARNING
● Read all instructions in the use and care manual before
operation.
● EXCESSIVE WEIGHT WARNING: Two people are required
to safely move this appliance.
● Use only the gas regulator and argon gas cylinders included with the system.
Instructions:
STEP 1
Move the wine dispensing system to a location
with a dedicated 120 Volt, 3-prong grounded
electrical outlet close by and adequate ventilation.
STEP 2
Plug one end of the plastic gas tubing into the
inert gas connector on the back of the system
(see below).
STEP 3
1” (2.5 cm)
min.
Make sure the cable coming from the power
supply (black box) on the back of the system is
connected to the Power Input connector on the
back of the unit.
Power supply output
connects here
Provide Proper Air Flow
120 Vac power
cord connects to
power supply
Plastic gas
tubing connects
here
Power
supply
Connect to 120 Vac, 60
Hz. electrical outlet
Gas and Electrical Connections
Part No. 107499 Rev. A
Wine Dispensing System
STEP 4
Open the door on the front of the
system. Swing the spout cover to the
up position.
STEP 5
Make sure the power switch, located
on the left side of the bottle bay, is
slid all the way down, to the OFF
position.
Spout cover
ON
SERVICE MODE
RESERVED
OFF
STEP 6
Find the gas regulator assembly
that comes with the system. Make
sure the regulator adjustment knob
is turned all the way in the OFF
direction.
STEP 7
Connect the gas supply line from
the wine dispensing system to the
gas connector on the regulator assembly.
STEP 8
Remove the plastic cap from the
top of the argon gas cylinder.*
STEP 9
Insert the top of the gas cylinder
into the bottom of the gas regulator assembly and turn it clockwise,
by hand, until it is snug. Do not
use a wrench or overtighten.
Regulator
adjustment
knob
Regulator
assembly
Argon
gas
cylinder
Gas supply
line from wine
dispensing
system
*IMPORTANT: The required argon
gas cylinder is not shipped with
the system and must be ordered
separately. Order on-line at www.
everythingdacor.com or by calling
Dacor Customer Service at (800)
793-0093 ex. 2822. Your first gas
argon gas cylinder is provided free
of charge.
STEP 10
Turn the regulator knob in the ON
direction until it stops.
STEP 11
Plug the power cord into the grounded 120 Vac., 60 Hz. electrical outlet.
STEP 12
Slide the power switch all the way up to the ON position. When powering on, the system will run through a series of diagnostics, which will take several seconds. If the
control panel is locked, perform the following steps:
•
Slide the power switch down one notch to the SERVICE MODE position (see diagram at top of page).
•
Push WineStation Service next to any of the displays.
•
Push Exit.
•
Slide the power switch up to the ON position.
Page 2
Quick Start Guide
STEP 13
Open a wine bottle and place it on a flat, dry
surface.
STEP 14
Insert the included head selection tool into
the bottleneck to determine the correct (color
coded) gasket size.
STEP 15
If you do not have a dispensing head with the
correct color gasket installed:
•
Remove the gasket nut on the bottom of
the head by turning it counter-clockwise.
•
Replace the gasket with the correct color
and replace the gasket nut.
Green
Red
White
Dispensing
head
Gasket
Gasket
nut
STEP 16
Insert a clean pick up tube into the bottle. (It
is normal for the upper end of the tube to extend beyond the tip of the bottle at this point).
STEP 17
Insert the pick up tube firmly into the opening
on the bottom of the head.
STEP 19
Fully un-tightened the head collar until it
stops.
STEP 20
Carefully insert the dispensing head (with the
pick up tube still attached) into the bottle.
STEP 21
While pressing down on the head with one
hand, tighten the collar with your other hand.
Use only two fingers and your thumb to turn.
The gasket will expand inside the bottleneck,
sealing and holding the bottle from the inside.
Do not over-tighten.
STEP 22
While holding the head and bottle over a
table or countertop for safety, grasp the top of
the head without touching the bottle. Lift the
head up 2 inches and shake slightly to check
that the bottle is snuggly attached. If the
bottle comes loose, retighten the head.
Page 3
Insert
pick-up
tube
Head Selection
Tool
STEP 23
Make sure that the rotor switch on the top of
the head lines up with the arrow on the back
of the head body.
STEP 24
Insert the dispensing head (with wine
bottle attached) into the slot in the desired
position in the bottle bay. Push only the
head, not the bottle.
STEP 25
Lower the spout cover by pushing up and
holding the lever on the bottom as you
lower it down. Once the spout cover is
closed, close the bottle bay door. Push in
slightly just above the lock until it snaps
shut.
STEP 26
Arrow on
head body
Rotor
switch
Spout cover
release lever
(on bottom of
spout cover)
Push the purge button (P) next to the
display above the bottle that has just been
inserted. The food grade argon will replace
the air in the bottle, assuring preservation.
The wine is now ready for serving. If a Check Bottle
message and/or a red light show on the control panel,
they will clear after the first pour with the new bottle.
DACOR
P
2008
Red Wine
C
1oz
3oz
6oz
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project