Broan | BR283003 | Specification Sheet | Broan BR283003 Specification Sheet

SPECIFICATION SHEET
MODELS 2830 & 2836
ECLIPSE
REMOTE DOWNDRAFT
TM
Control a powerful exterior blower from the
cooktop location.
TYPICAL SPECIFICATION
FEATURES
Downdraft blower system shall be Broan Model 2830
(Broan Model 2836).
HOUSING:
•
•
•
•
Rugged steel construction
Finished with black, electrically-bonded epoxy paint
Space-saving - can be used with most cooktops on the
market
30" or 36" size - Fits standard-size cabinets
AIR VENT ASSEMBLY:
•
•
•
•
•
•
•
Brushed stainless steel cover - just press button
to turn unit "ON"
Designer White or Black doors - available
separately
Air vent rises to 7" from cooktop for optimum
removal of cooking contaminants
Two washable aluminum grease filters
Stainless steel face plate - makes cleanup quick
and easy
Flush-mounted, infinite speed blower control
Conveniently located button - press to lower air
vent and turn unit "OFF"
Unit to have steel housing with electrically-bonded paint
finish. Air vent to rise at least 7" and have a stainless steel
face plate for ease of cleaning.
Filters to be washable and removable from above.
3¼" x 10" duct connector shall be adjustable to
accomodate different duct positions.
Downdraft system shall operate on 120 VAC and be able
to be plugged into a standard grounded outlet. It will have
an infinite speed blower control.
SPECIFICATIONS
VOLTS Hz
120
60
AMPS
DISCHARGE
6 Amps
3¼" x 10"
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
REFERENCE
QTY.
REMARKS
Project
Location
Architect
Engineer
Contractor
Submitted by
Date
20G
99041821E
INSTALLATION PLANNING - MODELS 2830 & 2836
DIMENSIONS
DOWNDRAFT
A
NOTE: Dimensions shown are for reference only. Before cutting
out countertop, refer to instructions packed with downdraft and
cooktop.
1 3/4 "
2"
COUNTER TOP
COOKTOP
B
DOWNDRAFT
FRONT TO BACK
INSIDE CABINET DEPTH
Refer to the cooktop installation instructions for dimensions of
cooktop, countertop cut-out, and cabinet requirements. The 2830
and 2836 can be installed in most standard 30" and 36" wide
cabinets.
Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
Pay special attention to the 4 areas of potential interference
highlighted above. The back of the downdraft cut-out will be 1-3/
4" from the cooktop and 2" of FLAT countertop is needed behind
cooktop.
DUCTWORK
The downdraft has 3¼" x 10" discharge. Transitions are available
to connect it to the 10" round inlet on the Broan Models 331 or 332
exterior blowers. See below.
TYPICAL INSTALLATION
COUNTER
TOP
CHIMNEYTOP
COOKTOP
7 7/8
AIR
VENT
3 5/8
3¼" X 10"
DUCT CONNECTOR
3-1/4" x 10"
TO 8"
TRANSITION
3-1/4" x 10"
DUCT CONNECTOR
2 FT.
120 VAC
GROUNDED
OUTLET
8" RD.
ELBOW
3-1/4" X 10"
90o ELBOW
8 FT.
6 FT.
8" x 10" TO
INCREASER
ELECTRICAL
The unit has a 2 ft. power cord with a 3-pronged plug. Plan to
provide a grounded outlet within reach of this cord. Outlet may
also be wall-mounted, with access hole in cabinet. If local codes
call for hard-wiring, see installation instructions.
The system will operate most efficiently when the ductwork does
not exceed 40 feet of equivalent duct. The illustrations above,
show equivalent feet of elbows and transitions. The number of feet
of straight 3-1/4" x 10" or 6" duct plus the equivalent feet of elbows
or transitions to be used should equal 40 feet or less.
Download PDF