SPECIFICATION SHEET
PIK SERIES
INSERT
HB0032
Especially designed to be installed in custom hood
for use over residential commercial-style cooking
surfaces.
FEATURES
•
•
•
•
•
•
•
Cabinet mount _ custom application
Widths: 33’’, 45’’
Halogen lighting (33’’_ 2 x 50 watt; 45’’_ 3 x 50 watt GU10)
Lamps included
Slide controls: Lighting, on-off, infinite speed
Easily accessible, dishwasher-safe stainless steel
baffle filters
Heat Sentry™ turns blower ON to HIGH speed when
excess heat is detected
For indoor use only
OPTIONS
• Custom hood liners (L33 or L45 Series):
Widths - 36’’, 42’’, 48’’, 54” and 60’’
Adjustable depth - see liner spec. sheet for details
Stainless Steel construction - protects custom hood base
and wipes clean easily
• Ambient light panel (ALP Series) for L Series custom
hood liners (Halogen lighting: 36’’ and 42’’_ 2 x 50 watt;
48”, 54” and 60” _ 3 x 50 watt GU10) Lamps included
• Backsplash (RMP Series):
Widths - 36”, 42”, 48”, 60”
Stainless Steel construction - protects back wall
and wipes clean easily
• WCPI Remote control: With Stainless Steel faceplate,
to fit any décor.
INSERT SPECIFICATIONS
120 VAC, 60 Hz
Amps (without blower) 0.8 (PIK33), 1.3 (PIK45)
HK0076A
Mount insert so bottom of custom hood is 24’’ to 30’’ above
cooking surface.
Custom Hood Liner
L33 or L45 Series
Ambient Light Panel
ALP Series
4”
Ad
inal
j
nom
”
(S ust
hood 54” or 60
m
sh ee able
to
,
s
”
cu 2”, 48
ee lin d
s
it
F
4
t fo er ep
36”,
r d spe th width
et c
ail
s)
HA0027A
WCPI Remote Control
Backsplash
RMP Series
6 3/8''
4 1/2''
HC0010
BEST Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
BEST Drummondville, QC Canada www.BestRangeHoods.com 866-737-7770
REFERENCE
QTY.
REMARKS
Project
Location
Architect
Engineer
Contractor
Submitted by
01G
Date
99044051D
PIK MOUNTING
Suggested Custom Hood Internal Framework
Size of the cut-out
NOTE: If optional L series liner is used, refer to installation
instructions for size and location of the cut-out.
3 1/2''
16 3/8''
17 1/16''
32 1/2'' or 44 1/2''
1 1/2”
2 1/4'' min.
HD0093A
HH0040A
NOTE: The 3 1/2’’ notch must be cut only if the WCPI
optional wall control will be installed.
- PIK33
AND PIK45 INSERT SYSTEM
INTERIOR BLOWERS
Model 647
(7” Round
wall cap)
Model 634 or 644
(roof cap)
Model 415
7” Round
adjustable elbow
(optional)
Model 643
(8” Round
wall cap)
8” Round
adjustable elbow
(optional)
8” Round
standard
duct
Model 407
(7” Round x 24’’
section)
8” Round
metal flexible duct
(optional)
7” Round
metal flexible
duct (optional)
Model 412
transition
(3¼” x 10” to 7”)
Model 413
transition
(3¼” x 10” to 8”)
Model 459
transition
(3¼” x 14” to 8”)
Adapter and damper 3¼’’ x 14’’
(supplied with P8 blower)
Adapter and damper 3¼’’ x 10’’
(supplied with P5 and P8 blowers)
Flow deviator
(supplied with P5 and P8 blowers)
L3336S, L3342S, L4548S
L4554S or L4560S
Custom Hood Liner (optional)
ALP36, ALP42,
ALP48, ALP54 or ALP60
Ambient light panel (optional)
PIK33 OR PIK45
INSERT
Rough-in kit
(supplied with P5 and P8 blowers)
WCPI
Wall control
(Optional)
Model P8
dual-blower (900 cfm)
NOTE: The dual blower P8 must be
installed with 8’’ round duct. If it
is impossible to connect the dual
blower P8 to a 8’’ round duct,
use a 7’’ round duct. In that
case, the blower performance
will be decreased by 25%.
Model P5
single-blower
(500 cfm)
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
HL0065
-3-
- PIK33
AND PIK45 INSERT SYSTEM
IN-LINE AND EXTERIOR BLOWERS
Model 437
(High capacity roof cap)
-
Model 441
Model ILB9 (800 cfm) (10” Round wall cap)
Model EB12 (1200 cfm)
or ILB11 (1100 cfm)
or EB15 (1500 cfm)
in-line blower
Model EB6 (600 cfm) exterior blower
(includes two 8” x 12” to
or EB9 (900 cfm)
10’’ round transitions)
exterior blower
Model 441
(10” Round
wall cap)
Model ILB6 (600 cfm)
in-line blower
(includes two 4½” x 18½”
to 10’’ round transitions)
Model ILB3 (280 cfm)
in-line blower
(includes one 8” to 10”
round transition)
Model 418
10” Round
adjustable elbow
(optional)
Model 410
(10” Rd duct
- 2 ft. sections)
10” Round
metal flexible duct
(optional)
L3336S, L3342S, L4548S
L4554S or L4560S
Custom Hood Liner (optional)
ALP36, ALP42,
ALP48, ALP54 or ALP60
Ambient light panel (optional)
PIK33 OR PIK45
INSERT
In-line and exterior blower
rough-in kit (included with ILB3,
ILB6, ILB9, ILB11, EB6, EB9,
EB12 and EB15 blowers)
WCPI
Wall control
(optional)
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
HL0066
Model 421
(10” Round vert.
in-line damper)
Recommended
for use with
exterior blowers
-4-
PIK SERIES INSERTS
BLOWER DUCTING
POSITIONS
MODEL PIK33 WITH P8 BLOWER (Vertical Outlet)
HB0032
MODEL PIK45 WITH P8 BLOWER (Vertical Outlet)
Top view
3/4’’
3 1/4’’
16 1/8’’
9 1/8’’
Top view
7 5/8’’
7/8’’
7/8’’ dia.
14’’
8’’ round
transition
HK0031A
MODEL PIK33 WITH P5 BLOWER (Vertical Outlet)
3/4’’
3 1/4’’
22 1/8’’
15 1/8’’
3/4’’
3 1/4’’
11 1/8’’
7 5/8’’
7/8’’
7/8’’ dia.
7’’ or 8’’
round transition
HK0030A
MODEL PIK33 WITH EB6, EB9, EB12 OR EB15
BLOWER (Vertical Outlet)
16 1/8’’
6 11/16’’
7/8’’ dia.
8’’ round
transition
HK0034A
MODEL PIK45 WITH P5 BLOWER (Vertical Outlet)
3/4’’
3 1/4’’
22 1/8’’
17 1/8’’
13 5/8’’
7/8’’
7/8’’ dia.
10’’
7’’ or 8’’
round transition
HK0033A
MODEL PIK45 WITH EB6, EB9, EB12 OR EB15
BLOWER (Vertical Outlet)
22 1/8’’
1 11/16’’
Top view
12 11/16’’
1 11/16’’
5 1/4’’
5 1/4’’
7/8’’ dia.
7/8’’ dia.
9 5/8’’ dia.
9 5/8’’ dia.
HK0032
HK0029
7/8’’
Top view
10’’
Top view
13 5/8’’
14’’
Top view
16 1/8’’