Kobe | RA0230SQB-DC48-1 | manual | Kobe RA0230SQB-DC48-1 Manual

KOBE Range Hoods
Premium Series
RA02 SQB-1 Series
Model No.
RA0230SQB-1 / RA0230SQB-DC24-1 / RA0230SQB-DC48-1 (30”)
RA0236SQB-1 / RA0236SQB-DC24-1 / RA0236SQB-DC48-1 (36”)
RA0242SQB-1 / RA0242SQB-DC24-1 / RA0242SQB-DC48-1 (42”)
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
IMPORTANT
READ THIS FIRST
READ BEFORE INSTALLATION
1. Carefully check all contents of packages.
2. Thoroughly inspect the unit for any shipping damages, cosmetic
damages or defects.
3. Have a certified contractor/electrician test the unit before installation.
IF THERE IS ANY PROBLEM:
1. DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL
PACKAGING MATERIAL.
2. Have your original invoice as proof of purchase and product serial
number ready.
3. Contact your merchant for product replacement due to shipping
damages, cosmetic damages or defects.
4. For other issues, email customer.service@koberangehoods.com or
call 1-626-775-8880 ext. 103, toll free 1-877-289-5623.
NO RETURN, NO REFUND, NO EXCHANGE IF:
1. PRODUCT HAS BEEN INSTALLED
2. KNOCK-OUT HOLES HAVE BEEN PUNCTURED
3. MISSING ORIGINAL PACKAGING MATERIAL
AND/OR PARTS
[ENGLISH]
- READ AND SAVE THESE INSTRUCTIONS -
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS ..................................................................................... 1
COMPONENTS OF PACKAGE................................................................................................... 3
INSTALLATION ........................................................................................................................... 4
OPERATION INSTRUCTIONS.................................................................................................... 8
MAINTENANCE .......................................................................................................................... 9
SPECIFICATIONS .................................................................................................................... 10
MEASUREMENTS & DIAGRAMS............................................................................................. 12
PARTS LIST.............................................................................................................................. 13
CIRCUIT DIAGRAM .................................................................................................................. 16
TROUBLE SHOOTING ............................................................................................................. 17
WARRANTY ............................................................................................................................. 18
PRODUCT REGISTRATION..................................................................................................... 20
- READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING ALL WIRING MUST BE DONE BY A PROFESSIONAL AND IN
ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES
IMPORTANT SAFETY INSTRUCTIONS
- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY,
OBSERVE THE FOLLOWING:
1) Installation and electrical wiring must be done by qualified professionals and in accordance with all
applicable codes and standards, including fire-rated construction.
2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden
utilities.
3) Ducted fans must be vented to the outside.
a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT SERVICE
PANEL.
b) Clean all grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly,
make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces or
garages.
NOTE
-
This warranty is invalid without an authorized agent’s receipt or if unit is
damaged due to misuse, poor installation, improper use, mistreatment,
negligence or any other circumstances beyond the control of KOBE
RANGE HOODS authorized agents. Any repair carried out without the
supervision of KOBE RANGE HOODS authorized agents will
automatically void the warranty.
-
KOBE RANGE HOODS will not be held responsible for any damages to
personal property or real estate or any bodily injuries whether caused
directly or indirectly by the range hood.
WARNING:
TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE
TOP GREASE FIRE:
1. Keep all fan, baffle/spacer/filter/oil tunnel/oil container and grease-laden surfaces clean. Grease
should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container.
2. Always turn hood ON when cooking.
3. Use high settings on cooking range ONLY when necessary.
4. Do not leave cooking range unattended when cooking.
5. Always use cookware and utensils appropriate for the type and amount of food prepared.
6. Use this unit only in the manner intended by the manufacturer.
7. Before servicing, switch power off at service panel and lock service panel (if possible) to prevent
power from switching on accidentally.
8. Clean ventilating fan frequently.
1
What to Do In The Event Of a Range Top Grease Fire
•
•
•
•
SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner.
KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go
out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
NEVER PICK UP A BURNING PAN – You May Get Burned.
DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result.
Use an extinguisher ONLY if:
a) You have a Class A, B, C extinguisher and know how to operate it.
b) The fire is small and contained in the area where it started.
c) The fire department has been called.
d) You can fight the fire with your back to an exit.
What to Do If You Smell Gas
-
Extinguish any open flame.
Do not try to turn on the lights or any type of appliance.
Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company and
Fire Department right away.
CAUTION
1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors.
2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) to prevent back drafting.
3) Follow the heating equipment manufacturer’s guideline and safety standards such as those published
by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities.
4) Activating any switch on may cause ignition or an explosion.
5) Due to the size and weight of this hood, two people installation is recommended.
ELECTRICAL SHOCK HAZARD – Can result in serious injury or death.
Disconnect appliance from electric power before servicing. If equipped,
the fluorescent light bulb contains small amounts of mercury, which must
be recycled or disposed of according to Local, State, and Federal Codes.
2
COMPONENTS OF PACKAGE
(Must keep all material for returns or refunds)
RA02 Series RANGE HOOD BOX
{A}
{B}
{C}
{D}
{E}
{F}
{G}
{H}
{I}
{J}
{K}
{L}
{M}
KOBE Range Hood
Warranty Registration Card
Quick Reference Guide
Oil Tunnel
Baffle Filter x 2 (30” & 36”)
x 3 (42”)
Spacer
8” Round Exhaust Plate (42” only)
Screws Package
Hood-Mounting Bracket
Screws Package
Duct Cover (Model No. RA02DC-1)
Wire Cap
Screws Package
{H}
30” & 36”
42”
{I}
{J}
{K}
{L}
{A}
Wire caps (3)
{M}
M4 x 1-1/2” (4)
Inner Duct Extension RA02DC-24-1
{B}
{C}
(Included in RA02 SQB-DC24-1 and SQB-DC48-1)
{N}
{D}
{O}
{P}
Inner Duct Extension
(Model No. RA02DC-24-1)
Duct Cover Mounting Bracket
Screws Package
{N}
{O}
{P}
{E}
M4 x 1-1/2” (2)
Outer Duct Extension RA02DC-24
(Included in RA02 SQB-DC48-1 Only)
{Q}
{F}
-
{G}
Outer Duct Extension
(Model No. RA02DC-24)
{Q}
FOR MORE INFORMATION, PLEASE VISIT OUR W EBSITE www.koberangehoods.com OR
CONTACT KOBE RANGE HOODS AT (626) 775-8880.
3
INSTALLATION
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installation
To calculate installation, please refer to TABLE 1. (All calculation in inches)
TABLE 1
A = Height of Floor to Ceiling
B = Height of Floor to Counter Top
(Standard: 36”)
C = Preferred Height of Counter Top to Hood
Bottom
30” & 36” Hood (Recommended 27” to 30”)
42” Hood (Recommended 30” to 36”)
[(A – B] – (D + E)]
D = Height of Hood
E = Height of Duct Cover
SAFETY WARNING
HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS
NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.
NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD
MAY OCCUR.
4
Figure 1
Preparation before Installation
NOTE:








TO AVOID DAMAGE TO YOUR HOOD,
PREVENT DEBRIS FROM ENTERING
THE VENT OPENING.
Decide the location of the venting pipe from the
hood to the outside. (Figure 1)
A straight, short venting run will allow the hood to
perform more efficiently.
Try to avoid as many transitions, elbows, and
long run as possible. This may reduce the
performance of the hood.
Temporarily wire the hood to test for proper
operation before installing.
Important: Peel protective film off the hood and
the duct cover (if any).
If necessary, prepare back wall frame with cross
framing lumber for secure installation. Refer to
Table 1 and measurements on Page 12 to decide
the level of the lumber. (Figure 2)
Loosen hood-mounting brackets at the back of
the hood, adjust brackets and tighten screws.
If necessary, remove the rubber stand on the
back of the hood. (Figure 3)
Figure 2
Figure 3
5
Figure 4
Hood Installation
CAUTION: If required to move the cooking
range to install the hood, turn off the power
on an electric range at the main electrical
box. SHUT OFF THE GAS BEFORE MOVING
A GAS RANGE.
1. Using references in Table 1 and measurements
on Page 12, mark the leveling locations point for
hood-mounting bracket on the wall.
2. Secure two mounting screws (provided) to the
wall, leaving an 1/8” space from the wall.
3. Align the hood-mounting bracket to the mounting
screws on the wall and hang hood into place.
4. Secure and tighten the mounting screws.
Figure 5
CAUTION: MAKE SURE HOOD IS SECURE
BEFORE RELEASING.
Wiring to Power Supply
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS RANGE
HOOD MUST BE PROPERLY GROUNDED. MAKE
SURE THIS IS DONE BY SPECIALIZED
ELECTRICIAN IN ACCORDANCE WITH ALL
APPLICABLE
NATIONAL
AND
LOCAL
ELECTRICAL CODES. BEFORE CONNECTING
WIRES, SWITCH POWER OFF AT SERVICE
PANEL AND LOCK SERVICE PANEL TO
PREVENT POWER FROM BEING SWITCHED ON
ACCIDENTALLY.
5. Connect the electrical wires.
- Connect three wires (black, white and green)
to house wires and cap with wire connectors.
Connect according to color: black to black,
white to white, and green to green as shown
on Figure 19.
- If necessary to hide the electrical wire
connections, push wires back into the wiring
box.
Access the wire connections
underneath the hood. To prevent any
damage, make sure wires do not slip
between motor or any moving parts.
6
Figure 6
Figure 7
Duct Cover Installation
6. Use 6” round steel pipe for 30” and 36” models or
8” round steel pipe for 42” model (follow building
codes in your area) to connect the exhaust on the
hood to the ductwork above. Use duct tape to
make all joints secure and air tight. Refer to
Figure 5.
7. Use four 4mm x 8mm screws (included) to attach
duct cover to hood. Refer to Figure 6.
Install Accessories
8. Attach oil tunnel. Refer to Figure 7.
9. Refer to Figure 23.  Slide the baffle filter into
the hood.  Push the baffle filter upward. 
Slide forward.  Pull downward.  Fit into
place.
10. Repeat until all baffle filters and spacers are
resting against oil tunnel. Refer to page 8.
Final Assembly
11. Turn power ON in control panel. Check all lights
and fan operation.
12. Make sure to leave this manual for the
homeowner.
7
Figure 8
OPERATION INSTRUCTIONS
This KOBE hood is equipped with two rotary controls with powerful centrifugal squirrel cage, baffle filters,
and bright LED lights.
The two rotary controls are Light Control & Speed Control. Refer to Figure 9.
Figure 9
Note: For best results, turn hood to QuietMode™ prior to preparation or cooking to establish
airflow in the kitchen. Adjust speed as needed.


Rotate the Speed Control clockwise to cycle from QuietMode™, Low, High, and Off;
and rotate counterclockwise to cycle from High, Low, QuietMode™, and Off.
Rotate the Light Control clockwise to turn on the light.
8
MAINTENANCE
For the optimal level of operation, clean the range hood surface and baffles regularly.
To Clean Hood Surface
CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS.
*** Regular care will help preserve its fine appearance.
1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth.
2. If hood looks splotchy (stainless steel hood), use an orange base cleaner to clean the surface of
the hood. Avoid cleaner to get on the control switches. Only spread a light coating over the
surface of the hood and leave on for a few minutes (do not leave on too long or this may cause
damage to hood finish). Use soft towel to wipe off the cleaning solution, gently rubs any stubborn
spots. Use a slightly damp towel to get rid of any cleaning solution. Use dry soft towel to dry the
hood.
3. To bring the glow back into a stainless steel finish, use a stainless steel cleaner.
4. DO NOT allow deposits to remain for long periods of time.
5. DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface
causing rust.
6. DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact
with stainless steel for extended periods. Many of these compounds contain chemicals, which
may be harmful. Rinse with water after exposure and wipe dry with a clean cloth.
To Clean Baffle Filters & Oil Tunnel
CAUTION: DRAIN BAFFLE FILTERS AND OIL TUNNEL BEFORE OIL WILL OVERFLOW.
1. Remove the baffle filters and oil tunnel.
2. Using a sponge, wash with warm soapy water. Dry completely before returning into place.
(Note: Baffle Filters are top rack dishwasher safe.)
9
SPECIFICATIONS
MODEL / SIZE
RA0230SQB-1 / 30” / Single Blower
RA0236SQB-1 / 36” / Single Blower
RA0242SQB-1 / 42” / Dual Blowers
RA0230SQB-DC24-1 / 30” / Single Blower
RA0236SQB-DC24-1 / 36” / Single Blower
RA0242SQB-DC24-1 / 42” / Dual Blowers
RA0230SQB-DC48-1 / 30” / Single Blower
RA0236SQB-DC48-1 / 36” / Single Blower
RA0242SQB-DC48-1 / 42” / Dual Blowers
COLOR
Commercial Grade Stainless Steel
CONSUMPTION / AMPERE
RA0230SQB-1– 320W / 2.86A
RA0236SQB-1– 320W / 2.86A
RA0242SQB-1– 350W / 3A
RA0230SQB-DC24-1 – 320W / 2.86A
RA0236SQB-DC24-1 – 320W / 2.86A
RA0242SQB-DC24-1 – 350W / 3A
RA0230SQB-DC48-1 – 320W / 2.86A
RA0236SQB-DC48-1 – 320W / 2.86A
RA0242SQB-DC48-1 – 350W / 3A
VOLTAGE
120V 60Hz
NUMBER OF BLOWER
1 – 30”, 36”
2 – 42”
DESIGN
18-Gauge Seamless / Satin Finish
FAN TYPE: CENTRIFUGAL
Squirrel Cage
EXHAUST
Top 6” Round – 30”, 36”
Top 8” Round – 42”
CONTROLS
Rotary Switch
LIGHTS
3-Watt LED x 2 – 30”, 36”
3-Watt LED x 3 – 42”
HOOD DIMENSION
(W x D x H)
RA0230SQB-1
RA0236SQB-1
RA0242SQB-1
RA0230SQB-DC24-1
RA0236SQB-DC24-1
RA0242SQB-DC24-1
RA0230SQB-DC48-1
RA0236SQB-DC48-1
RA0242SQB-DC48-1
10
29-3/4” x 24” x 18”
35-3/4” x 24” x 18”
41-3/4” x 24” x 18”
29-3/4” x 24” x 18”
35-3/4” x 24” x 18”
41-3/4” x 24” x 18”
29-3/4” x 24” x 18”
35-3/4” x 24” x 18”
41-3/4” x 24” x 18”
DUCT COVER DIMENSION
(W x D x H)
1) RA02DC-1 (Original Duct Cover)
15” x 12” x 12”
2) RA02DC-24-1 (Inner Duct Extension)
15” x 12” x 24”
3) RA02DC-24 (Outer Duct Extension)
15” x 12” x 24”
OPTIONAL ACCESSORIES
(W x D x H)
1) 30” Stainless Steel Back Panel
Model No.: SSP30 (30” x 32”)
2) 36” Stainless Steel Back Panel
Model No.: SSP36 (36” x 32”)
Net
55.0
60.0
75.0
5.0
Gross
67.0
74.0
91.0
7.0
QuietMode
Low
High
Air Capacity (cfm)
Sone*
300
1.8
580
4.7
760
5.4
Air Capacity (cfm)
Sone*
450
2.5
800
6.0
1200
8.0
HOOD WEIGHT (lbs)
SPEED
SINGLE BLOWER
RA0230SQB-DC-1
RA0236SQB-DC-1
RA0230SQB-DC24-1
RA0236SQB-DC24-1
RA0230SQB-DC48-1
RA0236SQB-DC48-1
DUAL BLOWERS
RA0242SQB-DC-1
RA0242SQB-DC24-1
RA0242SQB-DC48-1
RA0230SQB-1
RA0236SQB-1
RA0242SQB-1
RA02DC-1
*One sone is equivalent to the sound of a refrigerator at 40 decibels.
**Specifications subject to change without notice.
11
MEASUREMENTS & DIAGRAMS
*** All inch measurements are converted from millimeters. Inch measurements are estimated.
*** All measurements in ( ) are millimeters.
MODEL NO.:
RA0230SQB-1 or RA0230SQB-DC-1 (30”)
RA0236SQB-1 or RA0236SQB-DC-1 (36”)
RA0242SQB-1 or RA0242SQB-DC-1 (42”)
Inner Duct Extension Model No.: RA02DC-24-1
*Included in RA02 SQB-DC24-1 and SQB-DC48-1 Series
Outer Duct Extension Model No.: RA02DC-24
*Included in RA02 SQB-DC48-1 Series only
12
Baffle Filter for RA02 Series
PARTS LIST
MODEL NO.:
RA0230SQB-1 / RA0230SQB-DC24-1 / RA0230SQB-DC48-1(30”)
RA0236SQB-1 / RA0236SQB-DC24-1 / RA0236SQB-DC48-1 (36”)
RA0242SQB-1 / RA0242SQB-DC24-1 / RA0242SQB-DC48-1 (42”)
NO.
1
2
3
4
4A
5
6
DESCRIPTION
6” Round Plastic Exhaust
8” Round Exhaust Plate
Duct Cover
LED Light (3W)
Valve Stem(LIGHT)
Valve Stem(ON/OFF)
Knob
Metal Oil Tunnel
Metal Oil Tunnel
Metal Oil Tunnel
7
Light Panel
8
Blower System
8A
9
Motor Support
Capacitor x 1PCS
10
Capacitor x 2PCS
LED Driver
11
Capacitor Panel
12
Baffle Filter
13
Stainless Steel Spacer {1-5/16”( 33)x14-3/8”(365)}
Stainless Steel Spacer {4-5/16”(109)x14-3/8”(365)}
Stainless Steel Spacer {15/16”(23)x14-3/8”(365)}
MODEL /SIZE
RA0230SQB-1/RA0236SQB-1
RA0242SQB-1
RA02DC
PART NO.
L1-0505-0003
L1-0505-0004
12-0200-012-61
L1-0403-0301
L1-0405-0404-B
RA0230SQB-1
RA0236SQB-1
RA0242SQB-1
RA0230SQB-1
L1-0405-0402-B
L1-0405-0400-A
B101-9130-14A
B101-9136-14A
B101-9142-14A
B101-0230-06
RA0236SQB-1
RA0242SQB-1
RA0230SQB-1/RA0236SQB-1
RA0242SQB-1
RA0242SQB-1
RA0230SQB-1/RA0236SQB-1
B101-0236-06
B101-0242-06
L1-0302-0120-802RO
L1-0302-0120-802RE
L1-0233-0242
L1-0401-0120-24
RA0242SQB-1
L1-0401-0120-24
L1-0402-D001
L1-0201-0230
L1-0201-0236
L1-0201-0242
L1-0214-0191
RA0230SQB-1
RA0236SQB-1
RA0242SQB-1
RA0230SQB-1
RA0236SQB-1
RA0242SQB-1
13
B101-9130-15
B101-9136-15
B101-9142-15
RA02 Series
Model No.: RA0230SQB-1 / RA0230SQB-DC24-1 / RA0230SQB-DC48-1 (30”)
RA0236SQB-1 / RA0236SQB-DC24-1 / RA0236SQB-DC48-1 (36”)
14
RA02 Series
Model No.: RA0242SQB-1 / RA0242SQB-DC24-1 / RA0242SQB-DC48-1 (42”)
15
CIRCUIT DIAGRAM
MODEL NO.:
RA0230SQB-1 / RA0230SQB-DC24-1 / RA0230SQB-DC48-1 (30”)
RA0236SQB-1 / RA0236SQB-DC24-1 / RA0236SQB-DC48-1 (36”)
MODEL NO.:
RA0242SQB-1 / RA0242SQB-DC24-1 / RA0242SQB-DC48-1 (42”)
16
TROUBLE SHOOTING
Issue
After
Installation,
both motors
and lights are
not working.
Lights are
working, but
motor(s) is
not.
Possible Cause
The power is not on.
Solution
Make sure the circuit breaker and the unit’s
power is ON. Use a voltage meter to check
the power supply.
The wire connection is not secure. Check and tighten wire connection.
The control panel is defective.
Replace the control panel.
The motor(s) is defective.
Replace the motor.
The capacitor(s) is defective.
Replace capacitor(s).
The control panel is defective.
Replace the control panel.
The range
hood is
vibrating.
The blower system is not secure.
The motor is
working, but
the lights are
not working.
LED Light(s) is defective.
The squirrel cage is not balanced.
Hood is not secured in place.
The light wiring(s) is loose.
Light transformer is defective.
The range
hood is not
venting out
correctly.
The control panel is defective.
The range hood is installed
outside of the manufacture
recommended clearance.
There is no make-up air inside the
house.
Obstacle blocking the pipe work.
Cold air is
coming into
the home.
The pipe size is smaller than the
suggested pipe size.
The pipe connection is not
properly sealed.
The damper is not properly
installed or is missing from the
installation.
The damper is not installed.
17
Tighten the turbine impeller/squirrel cage
and air chamber.
Replace the squirrel cage.
Check the installation of hood, tighten the
mounting bracket.
Replace the LED light.
Check wire continuity from light transformer
to LED light housing(s).
Check power input and power output on the
light transformer. If it’s needed, replace the
light transformer.
Replace the control panel.
Adjust the clearance between the range
hoods and cook top to 27” to 30”. For
Island range hood, the clearance between
the range hoods and cook top is 30” to 36”.
Open the window to enhance the
performance of the range hood by creating
a sufficient make-up air.
Remove all obstacles from the duct work.
Change the ducting according to the
manufacture suggestion.
Check the pipe installation.
Check the damper installation.
By installing the damper, it will help to
eliminate air backflow.
WARRANTY
WARRANTY CERTIFICATE
In order to obtain warranty service, you must provide proof of original purchase from a
KOBE authorized Dealer. Please keep a copy of your original invoice as proof of
purchase.
TWO-YEAR LIMITED LABOR WARRANTY ON KOBE PREMIUM SERIES:
For two years from the date of your original invoice from a KOBE authorized dealer, we will repair
any parts or components free of charge that failed due to manufacturing defects. KOBE reserves
the right to replace, rather than repair the product free of charge at our sole discretion.
It is your sole responsibility to ensure the product is readily accessible for the service technician
to perform repairs. The service technician will not, under any circumstance, remove, alter
or modify any fixture built around and/or connected to the product to gain access to
perform repairs.
TWO-YEAR LIMITED PARTS WARRANTY ON KOBE PREMIUM SERIES:
For two years from the date of your original invoice from a KOBE authorized dealer, we will
provide non-consumable replacement parts or components free of charge that failed due to
manufacturing defects. Consumable parts such as lights bulbs, filters, fuses, and oil cups are
not covered by this warranty.
WHAT IS COVERED:
This warranty is valid in the United States and Canada. It is non-transferable and applies only to
the original purchaser and does not extend to subsequent owner of this product. In Hawaii,
Alaska and Canada, this warranty is limited. There may be additional shipping charges for parts
and service technician travel costs in remote areas or locations 30 miles outside of KOBE
authorized service area.
WHAT IS NOT COVERED:
1. Normal wear and tear, regular service and maintenance required for the product.
2. Consumable parts such as light bulbs, filters, fuses, and oil cups.
3. Chips, scratches or dents due to abuse or misuse of the product, use of corrosive and
abrasive cleaning products.
4. Damages caused by accident, fire, flood and other Acts of God.
5. Services in remote areas or locations 30 miles outside of KOBE authorized service area.
6. Labor cost incurred in connection with the removal of range hood, and reinstallation of
replacement range hood, nor does it cover any other contingent expenses.
7. Scratches inside the hood, back of the baffle filter, and inside the duct cover.
18
THIS WARRANTY WILL BE VOIDED WHEN:
1. Improper installation and failure to follow installation instructions.
2. Any repair, alteration, modification not authorized by KOBE.
3. Duct alteration, modification and connection.
4. Incorrect electric current, voltage or wiring.
5. Improper usage of the product such as commercially, outdoor or other usage other than
its intended purpose which is residential indoor usage only.
6. Product is purchased from an unauthorized KOBE dealer.
7. Product is damaged due to negligence, misuse, abuse, accident.
If we determine that the warranty exclusions listed above applies or if you fail to provide all
necessary documentation for warranty service, you will be responsible for all expenses
associated with the requested service, including parts, labor, shipping, travelling, and any other
expense related to the service request.
TO REQUEST WARRANTY SERVICE, PLEASE CONTACT KOBE RANGE HOODS
SERVICE CENTER:
From the 48 contiguous states:
Email (best): customer.service@koberangehoods.com
Phone: 1-626-775-8880 ext. 103
Toll Free: 1-877-BUY-KOBE (289-5623)
From Alaska, Hawaii, and Canada:
Email (best): customer.service@koberangehoods.com
Phone: 1-626-775-8880 ext. 103
19
WARRANTY INFORMATION FORM
Fill in the blanks and keep this paper with the original invoice in a
safe place for future service purpose.
1. Date of purchase
:
2. Model No.
:
3. Serial No.
:
For warranty service or spare parts purchase in US, contact:
KOBE Service Center
Email (best): customer.service@koberangehoods.com
Phone: 1-626-775-8880 ext. 103
Toll Free: 1-877-BUY-KOBE (289-5623)
For Warranty service or spare parts purchase in Canada, contact:
Email (best): customer.service@koberangehoods.com
Toll Free: 1-626-775-8880 ext. 103
Your notes:
20
KOBE Range Hoods
11775 Clark Street
Arcadia, CA 91006 USA
www.koberangehoods.com
This KOBE hood is made for use in the USA and CANADA only. We do not recommend
using this hood overseas as the power supply may not be compatible and may violate the
electrical code of that country. Using a KOBE hood overseas is at your own risk and
will void your warranty.
Cette hotte KOBE est fabriquée pour usage aux États-Unis et au Canada seulement. Il
n’est pas recommandé d’utiliser cette hotte à l’étranger puisque l’alimentation électrique
pourrait ne pas être compatible et enfreindre le code de l’électricité de ce pays. L’usage
de la hotte KOBE à l’étranger est à votre propre risque et la garantie sera annulée.
Esta campana de extracción KOBE ha sido fabricada para ser utilizada únicamente en
EE.UU. y CANADÁ. No recomendamos la utilización de esta campana en el extranjero