Maytag | UXT5530AAS | Dimension Guide | Maytag UXT5530AAS Dimension Guide

Maytag UXT5530AAS Dimension Guide
Range Hood - 30" (76.2 cm) and 36" (91.4 cm)
PRODUCT MODEL NUMBERS
UXT5530AA
PRODUCT DIMENSIONS
UXT5536AA
1³⁄₁₆"
(3.0 cm)
12"
(30.5 cm)
7¹⁄₄"
(18.4 cm)
Electrical: A 120 volt, 60 Hz, AC only, 15- or 20-amp,
fused electrical circuit is required. A time-delay fuse or
circuit breaker is also recommended. It is recommended
that a separate circuit serving only this range hood be
provided.
CABINET OPENING DIMENSIONS
3" (7.6 cm) 30" (76.2 cm) model
5³⁄₄" (14.6 cm) 36" (91.4 cm) model
⁵⁄₈"
(1.6 cm)
2"
(5.1 cm)
9"
(22.9 cm)
⁵⁄₈"
(1.6 cm)
C
19³⁄₄"
(50.2 cm)
29 ⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model
35 ⁷⁄₈" (91.1 cm) - 36" (91.4 cm) model
B
D
VENTING REQUIREMENTS
Vent system can terminate either through the roof or wall. Use 3¹⁄₄" x 10" (8.3 x 25.4 cm)
with a maximum vent length of 35 ft (10.7 m) or 6" (15.2 cm) or larger round vent with a
maximum length of 50 ft (15.2 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air
turbulence that gently reduce performance.
A
Roof Venting
A
E
E
B
Wall Venting
A
B
C
E
C
A. 18" (45.7 cm) min. clearance - upper cabinet to countertop
B. 24" (61.0 cm) min. for electric cooking surfaces
27" (68.6 cm) min. for gas cooking surfaces
30" (76.2 cm) suggested max. - bottom of range hood to
cooking surface
C. 30" (76.2 cm) or 36" (91.4 cm) min. cabinet opening width
D. 13" (33.0 cm) cabinet depth
E. 36" (91.4 cm) base cabinet height
LOCATION REQUIREMENTS
IMPORTANT: Observe all governing codes and
ordinances.
It is the installer’s responsibility to comply with
installation clearances specified on the model/serial
rating plate. The model/serial rating plate is located
inside the range hood on the left wall.
● Range hood location should be away from strong draft
areas, such as windows, doors and strong heating
vents.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards,
Title 24 CFR, Part 328 (formerly the Federal Standard
for Mobile Home Construction and Safety, title 24, HUD,
Part 280) or when such standard is not applicable, the
standard for Manufactured Home Installation 1982
(Manufactured Home Sites, Communities and Setups)
ANSI A225.1/NFPA 501A*, or latest edition, or with
local codes.
●
D
D
A. 6" (15.2 cm) or larger round
vent or a 3¹⁄₄" x 10" (8.3 x
25.4 cm) rectangular vent
through roof
B. Round vent: use 6" (15.2 cm)
or larger round damper
(purchased separately)
C. Round vent: use 3¹⁄₄" x 10"
(8.3 x 25.4 cm) to 6" (15.2 cm)
or larger diameter transition
piece
(purchased separately)
D. 24" (61.0 cm) - 30" (76.2 cm)
above electric cooking surface
27" (68.6 cm) - 30" (76.2 cm)
above gas cooking surface
E. Roof cap
A. 6" (15.2 cm) or larger round
vent or a 3¹⁄₄" x 10" (8.3 x
25.4 cm) rectangular vent
through the wall
B. Round vent: use 3¹⁄₄" x 10" (8.3
x 25.4 cm) to 6" (15.2 cm) or
larger diameter transition piece
(purchased separately)
C. 3¹⁄₄" x 10" (8.3 x 25.4 cm)
through the wall
D. 24" (61.0 cm) - 30" (76.2 cm)
above electric cooking surface
27" (68.6 cm) - 30" (76.2 cm)
above gas cooking surface
E. Wall cap
Page 1 of 2
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10274302B
10/22/09
Calculating Vent System Length
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
6" (15.2 cm) or Larger Round Vent System
Vent Piece
Round
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
90° elbow
5.0 ft
(1.5 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
flat elbow
12.0 ft
(3.7 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
wall cap
0.0 ft
(0.0 m)
Vent Piece
Round
45° elbow
2.5 ft
(0.8 m)
90° elbow
5.0 ft
(1.5 m)
6" (15.2 cm) or larger
wall cap
0.0 ft
(0.0 m)
Example vent system
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) or larger
4.5 ft
(1.4 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) or larger
90° elbow
5.0 ft
(1.5 m)
3¹⁄₄" x 10"
(8.3 x 25.4 cm)
elbow
Wall cap
6 ft (1.8 m)
2 ft (0.6 m)
Maximum Recommended Length
Wall cap
2 ft
(0.6 m)
Example vent system
90˚ elbow
6 ft (1.8 m)
Maximum Recommended Length
= 35 ft (10.7 m)
1 - 90° elbow
= 5.0 ft (1.5 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
1 - wall cap
= 0.0 ft (0.0 m)
Length of 3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
system
= 13.0 ft (3.9 m)
= 50 ft (15.2 m)
1 - 90° elbow
= 5.0 ft (1.5 m)
1 - wall cap
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
Length of 7" (17.8 cm) system
= 13.0 ft (3.9 m)
Page 2 of 2
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10274302B
10/22/09
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising