Frigidaire | RC30DE60PB | Spec sheet | Frigidaire RC30DE60PB Spec Sheet

Built-In Downdraft Cooktop
RC30DE60PB
30" Electric
Product Dimensions
Width30-3/4"
Depth22-1/16"
Height (Min.)/(Max.) 18-19/32"/ 23-3/8"
More Easy-To-Use Features
SpaceWise® Expandable
Elements
Flexible elements expand to
your cooking needs.
Hot Surface Indicators
Smoothtop Ceramic Glass
Cooking Surface
3 Ducting Options
Dishwasher-Safe Filter
Available in:
Black
(B)
Signature Features
Downdraft System
PowerPlus® Boil
Pro-Select® Controls
SpaceWise® Bridge Element
Whisks away odors and smoke without
the need for overhead ventilation.
Precise control at your fingertips.
Elements
Size
Watts
Right Front
9"
3,200
Right Rear
5" / 7"
750 / 1,800
Left Front
7"
1,800 / 2,600
Left Rear
7"
1,800
Left Bridge
SpaceWise®
Bridge
800
Boil water faster.
A flexible element lets you combine
two elements into one to fit larger
cookware.
frigidaire.com
30" Drop-In Electric Cooktop with Downdraft
Built-In Downdraft Cooktop
Non Branded
RC30DE60PB
30" Electric
Features
Controls
Pro-Select®
Surface Type
Black Ceramic Glass
Right Front Element (Watts)
9" - 3,200
Right Rear Element (Watts)
5" / 7" - 750 / 1,800
Left Front Element (Watts)
7" - 1,800
Left Rear Element (Watts)
7" - 1,800
Left Bridge Element (Watts)
SpaceWise® Bridge - 800
Center Element (Watts)
Hot Surface Indicators
Yes
Control Location
Right Side
Knob Color
Black
Knob Type
Plastic
Nominal Width
30"
Installation Type
Built-In Downdraft
Style
In-Cabinet
Air Discharge
Rear, Down1
Air Delivery (CFM)
500
Intake Area
39 Sq. In.
Blower Type
Centrifugal
Sound Level (dBA)
71
Fan Speeds
3-Speed
B
A
Dishwasher-Safe Stainless Steel Filters 1
Exhaust Duct
External
Duct Required
3-1/4" x 10" or 6" Round
Optional Accessories
Alternate Duct Transition Kit
PN #5304488297
Rear
Specifications
Power Supply Connection Location
Right Front
Voltage Rating
240V /208V / 60Hz
Connected Load
(kW Rating) @ 240 / 208 Volts2
41.7/36.4
Amps @ 240 / 208 Volts
50
Minimum Circuit Required (Amps)
50
C
Right Side View
Approved for Electric Single
Wall Oven Combination Installation
Shipping Weight (Approx.)
78 Lbs.
own discharge can also be adapted for alternate ductwork installation
D
providing left or right exhaust, by ordering Alternate Duct Transition Kit
(PN # 5304488297).
2
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz AC
only electrical supply with ground required on separate circuit fused on
both sides of line.
1
Down
NOTE: For planning purposes only. Always consult local and national electric codes.
Refer to Product Installation Guide for detailed installation instructions on the web
at frigidaire.com.
Product Dimensions
Cutout Dimensions
A - Width
30-3/4"
Width (Min.)/(Max.)
28-7/8"/29"
B - Depth
22-1/16"
Depth (Min.)/(Max.)
21-1/8"/21-1/4"
C - Height (Min.)/(Max.)3
18-19/32"/23-3/8"
Height (Min.)/(Max.)
18-19/32"/23-3/8"
Overall height determined by discharge direction.
3
Granite Countertop
Installation Kit available.
Accessories information available
on the web at frigidaire.com
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
RC30DE60P 07/13
© 2013 Electrolux Home Products, Inc.
Specifications
subject to change.
30" Electric Cooktop/Downdraft Vent (RC30DE60P)
Built-In Downdraft Cooktop
Non Branded
30" Electric
RC30DE60PB
30" Electric Cooktop
with Ventilation Unit
30"
221/16"
30 3/4"
13"
max.
cabinet
depth
For ventilation unit ductwork preparation and
installation planning information, refer to 30"
Electric Cooktop Ductwork Preparation page.
30" min. for
unprotected
cabinet bottom
24" min.
for protected
cabinet bottom
Rear Discharge
Right Side View
18"
min.
18 19/32"
Ventilation
unit not shown
beneath cooktop.
3 9/32"
20 27/32"
28 19/32"
21 11/16"
Down Discharge
1" minimum flat distance
from cutout edge
Right Side View
28 7/8" min.
29" max.
211/8" min.
211/4" max.
9" min. to nearest
combustible wall
(each side of unit)
24"
23 3/8"
1" minimum flat distance
from cutout edge
Built-In Cooktop Specifications
• Shipping Weight (approx.) – 78 Lbs.
• Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
• Connected Load (kW Rating) @ 240 / 208 Volts = 41.7 / 36.4 kW
• Amps @ 240 / 208 Volts = 50 Amps
• Recommended Circuit Breaker – 50 Amps
• Always consult local and national electric codes.
• For detailed electrical supply location, refer to 30" Electric Cooktop
(RC30DE60P) Ductwork Preparation page.
• Locate cooktop between wall studs or floor joists so that ductwork
may be installed properly.
• Installing cooktop into pre-existing base cabinets may require
modifications. Cabinets with drawers require drawers be removed
and drawer fronts attached to cabinet face. Verify internal length
and width of cabinet base because sides or back wall may need
cut out and corner braces removed to accommodate unit.
• Countertop opening MUST be cut based on dimensions shown,
cut squarely with sides parallel to each other and with front and
rear perpendicular to cabinet sides.
• Pre-formed countertops with raised lip and radius at base of
backsplash may not allow enough flat area for proper installation.
Minimum 1" distance required from rear and front edge of cooktop
cutout.
• Overhead cabinetry should not exceed a 13" maximum depth.
• Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than 30".
• Allow 30" minimum clearance between top of cooktop platform
and bottom of unprotected wood or metal overhead cabinet; or 24"
minimum clearance when bottom of wood or metal overhead cabinet
is protected by not less than 1/8" flame-retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015" stainless steel,
0.024" aluminum or 0.020" copper.
• Allow 9" minimum required clearance from left edge and right edge
of cooktop to nearest combustible wall on each side.
Ductwork Preparation
• For ventilation unit ductwork preparation and planning
information, refer to 30" Electric Cooktop (RC30DE60P) Ductwork
Preparation page.
• Down discharge can also be adapted for alternate ductwork
installation providing left or right exhaust, by ordering Alternate
Duct Transition Kit (PN # 5304488297).
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
• Granite Countertop Installation Kit – (PN # 903061-9010).
• Alternate Duct Transition Kit – (PN # 5304488297).
Accessories information available
on the web at frigidaire.com
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
RC30DE60P 07/13
© 2013 Electrolux Home Products, Inc.
Specifications
subject to change.
Built-In Downdraft Cooktop
RC30DE60PB
30" Electric Downdraft Cooktop –
Ductwork Preparation
30" Electric
Electrical Supply Location
Ventilation unit comes detached from cooktop.
To ensure proper installation, refer to 30" Electric Downdraft
Cooktop Specifications page for planning information, and
installation guide on web for complete installation details
including countertop and cabinet requirements.
Cabinet
side wall
41/2" 6"
5 1/2"
Cabinet
side wall
CL
Ducting Options
On floor, through floor or through wall.
Exhaust Outlet Locations –
Countertop
surface
Electrical
Installation Note:
Locate junction
box under cabinet
within shaded
area shown and
run 120/240 or
120/208 Volt, AC
wire from main
circuit panel.
Cut exhaust outlet hole in wall or floor based on
desired installation. Exhaust duct MUST be located
between wall studs or floor joists.
1 13/16"
Cutout
center
Cutout
center
22 3/4"
8 27/32"
6"
1 13/16"
Rear Wall
Exhaust Outlet
Cutout
center
3 3/4"
3 27/32"
Alternate
Side Exhaust
Outlets
Bottom
Exhaust Outlet
Alternate Duct Transition Kit
PN #5304488297
Available for use with
left or right exhaust
ductwork.
Built-In Cooktop Ductwork Preparation
• Ventilation unit comes detached from cooktop. To ensure proper
installation, refer to 30" Electric Downdraft Cooktop Specifications
page for planning information, and installation guide on web for
complete installation details including countertop and cabinet
requirements.
• Ducting Options – On floor, through floor or through wall.
• Ventilation Unit Discharge Options – Rear or down.
• Down discharge can also be adapted for alternate ductwork
installation providing left or right exhaust, by ordering Alternate
Duct Transition Kit (PN # 5304488297).
• Consider ductwork location and desired installation before cutting
exhaust outlet hole in cabinet. For proper installation, cooktop
exhaust duct MUST be located between wall studs or floor joists.
• Vent exhaust air outside only and NOT into any concealed space.
• Exhaust Duct Required – Galvanized or aluminum duct in 6" round
or 3-1/4" x 10" rectangular, or combination of both. PVC should
be used if installing under concrete slab.
• Local building code must be followed in specifying approved type
and schedule of ALL duct used; always use appropriate roof or
wall cap with damper.
• For maximum efficiency, use shortest, straightest duct run p
ossible.
Unit operates most efficiently with up to 100 equivalent feet of duct.
(Refer to Calculating Duct Length Table in Product Installation Guide.)
• Flexible ducting is not recommended due to severely restricted
airflow; if blower outlet and floor or wall duct location do NOT align,
flexible METAL ducting can be used to adapt to offset.
• Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold. Cold weather installations should
have additional backdraft damper installed.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
• Alternate Duct Transition Kit – (PN # 5304488297).
Accessories information available
on the web at frigidaire.com
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
RC30DE60P 07/13
© 2013 Electrolux Home Products, Inc.
Specifications
subject to change.
Download PDF

advertising