Thermador | PCG364NL | Spec sheet | Thermador PCG364NL Spec Sheet

Thermador PCG364NL Spec Sheet
PCG364NL
36-INCH GAS RANGETOP WITH GRILL
PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE
GENERAL PROPERTIES
Controls
Metal Knobs
Sealed Burners
Yes
Grate Material
Cast Iron
BURNER PERFORMANCE
Total Number of Cooktop Burners
4
Total BTU Load (NG / LP)
72,000
Power of Front Left Burner (NG / LP)
18,000
Power of Back Left Burner (NG / LP)
18,000
Power of Back Center Burner (NG / LP)
N/A
Power of Front Center Burner (NG / LP)
N/A
- 18,000 BTU (NG) Star® Burners
Power of Center 12" Electric Griddle (W)
N/A
- Superior grill results–1,630 Watt indoor electric grill
Power of Center 12" Electric Grill (W)
1,630 W
-N
on-stick, rust-proof cast-aluminum grill with fusion coated
surface, removable for easy cleanup
Power of Back Right Burner (NG / LP)
18,000
Power of Front Right Burner (NG / LP)
18,000
FEATURES & BENEFITS
- Patented Pedestal Star® Burner with QuickClean Base®
designed for easy surface cleaning and superior heat spread
for any size pan
- Precision simmering capabilities as low as 100°F (375 BTU)
with 2 ExtraLow® Simmer burners
TECHNICAL DETAILS
ACCESSORIES (OPTIONAL)
PABRICKBKN
Black Ceramic Briquettes with Basket
PA12LCVRN
12" Pro Grill Cover for Indoor Electric Grill
PAGRIDDLEN
12" Pro Griddle
Circuit Breaker (A)
15 A
Volts (V)
120 V
Frequency (Hz)
60 Hz
Plug Type
120V-3 Prong
Power Cord Length (in)
72"
Energy Source
Gas
Gas Type
Natural Gas 15 mbar
(USA)
Alternative Gas Type
LP 27, 5 mbar (USA)
Convertible To LP (Kit Required)
Yes
DIMENSIONS & WEIGHT
PA12CHPBLK
12" Cutting Board
PWOKRINGHC
Wok Ring
PA36GLBC
9" Low Backguard
Overall Appliance Dimensions (H*xWxD) (in)
10 9/16" x 35 15/16"
x 25 13/16"
Required Cutout Size (HxWxD) (in)
7 11/16" x 35 1/8"
x 22 13/16"
Minimum Distance From Rear Wall (in)
12" min to
Combustible Surface
with Flush Island Trim
Net Weight (lbs)
155 lbs
ACCESSORIES (INCLUDED)
1 x Island Trim
WARRANTY
PAKNOBLUNH
Blue Knob Kit
Limited Warranty, Entire Appliance,
Parts and Labor
*Height Includes Gas Connection
PALPKITHN
LP Conversion Kit
T
HERMADOR EXCLUSIVE
Page 1 of 4
2 Year
PCG364NL
36-INCH GAS RANGETOP WITH GRILL
PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE
36-INCH RANGETOP AND CUTOUT DIMENSIONS
Page 2 of 4
PCG364NL
36-INCH GAS RANGETOP WITH GRILL
PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE
36-INCH RANGETOP CLEARANCE REQUIREMENTS
as defined in the “National Fuel Gas Code” (ANSI Z223.1,
Current Edition). Clearances from non-combustible materials
are not part of the ANSI Z21.1 scope and are not certified by
CSA. Clearances of less than 12” (305 mm) must be approved
by the local codes and/or by the local authority having
jurisdiction.
NOTE: A 36-inch minimum clearance is required between the top of the cooking surface and the bottom of an unprotected cabinet. A 30-inch
clearance can be used when the bottom of the wood or metal cabinet is protected by not less than 1/4 inch of a flame retardant material covered with
not less than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper.
Page 3 of 4
PCG364NL
36-INCH GAS RANGETOP WITH GRILL
PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE
ELECTRICAL AND GAS LOCATIONS
The gas and electrical supply must be located in an area that is accessible without requiring
removal of the rangetop. The appliance electrical power cord and gas pipe connection are located
on the left rear underside of the rangetop.
The junction box must be located within 3 feet (~900 mm) of the rangetop connection.
NATURAL GAS REQUIREMENTS:
Inlet Connection: 1/2" NPT (min. 3/4" dia. flex line)
Supply Pressure: 6" min. to 14" max. water column (14.9 mb to 34.9 mb)
Manifold Pressure: 5" water column (12.5 mb)
PROPANE GAS REQUIREMENTS:
Inlet Connection: 1/2" NPT (min. 3/4" dia. flex line)
Supply Pressure: 11" min. to 14" max. water column (27.4 mb to 34.9 mb)
Manifold Pressure: 10" water column (24.9 mb)
These warranties give you specific legal rights and you may have other rights that vary from state to state. Full warranty and limited warranty from date of installation. For complete warranty
details, refer to your Use & Care manual, or ask your dealer.
Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilation
engineer for your specific ventilation requirements. For the most detailed information, refer to installation instructions accompanying product or write to Thermador indicating the model
number. Specifications are correct at time of printing. Thermador reserves the right to change product specifications or design without notice. Some models are certified for use in Canada.
Thermador is not responsible for products that are transported from the U.S. for use in Canada.
1 800 735 4328 | USA THERMADOR.COM | CANADA THERMADOR.CA | ©2015 BSH HOME APPLIANCES CORPORATION. ALL RIGHTS RESERVED.
Page 4 of 4
04 / 15
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising