Installation Instructions
Gas Cooktops
Questions? Call GE Appliances at 1.800.GE.CARES (1.800.432.2737) or visit
www.GEAppliances.com. In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca.
IN THE COMMONWEALTH
OF MASSACHUSETTS
ŶThis product must be installed by a licensed
plumber or gas fitter.
WARNING
FIRE OR EXPLOSION
HAZARD
If the information in these instructions is not
followed exactly, a fire or explosion may
result causing property damage, personal
injury or death.
Installation must be performed by a qualified
installer.
Read these instructions completely and carefully.
Installation of this product must conform with
local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/
NFPA.54, latest edition. In Canada, installation
must conform with the current Natural Gas
Installation Code, CAN/CGA-B149.1 or the
current Propane Installation Code, CAN/CGAB149.2, and with local codes where applicable.
This product has been design-certified by UL
ŶWhen using ball type gas shut-off valves,
they shall be the T-handle type.
ŶA flexible gas connector, when used, must
not exceed 5 feet.
according to ANSI Z21.1, latest edition and
Canadian Gas Association according to CAN/
CGA-1.1 latest edition.
When installing a gas appliance the use of
old flexible connectors can cause gas leaks
and personal injury. Always use a NEW
flexible connector.
Leak testing of the appliance shall be conducted
according to the manufacturer instructions.
The cooktop must be electrically grounded
in accordance with local codes or, in the
absence of local codes, in accordance with the
National Electrical Code (ANSI/NFPA 70, latest
edition). In Canada, electrical grounding must
be in accordance with the current CSA C22.1
Canadian Electrical Code Part 1 and/or local
codes. See Electrical Connections in this section.
Do not install this product with an air curtain
hood or other cooktop hood that operates by
blowing air down on the cooktop. This airflow
may interfere with operation of the gas burners
resulting in fire or explosion hazard.
FOR YOUR SAFETY
WARNING
Before beginning the installation, switch power off at service panel and lock
the service disconnecting means to prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
TOOLS YOU WILL NEED
Phillips
screwdriver
Flat-blade
screwdriver
Open-end or
adjustable wrench
Saber Saw
Pipe wrenches (2)
(one for backup)
Pencil and ruler
MATERIALS YOU MAY NEED
ŶGas line shut-off valve
ŶPipe joint sealant or UL-approved pipe thread
tape with Teflon* that resists action of natural
and propane gases.
ŶFlexible metal appliance connector (1/2” I.D.).
A 5-foot length is recommended for ease of
installation but other lengths are acceptable.
Never use an old connector when installing a
new cooktop.
ŶFlare union adapter for connection to gas
supply line (3/4” or 1/2” NPT x 1/2” I.D.).
ŶFlare union adapter for connection to pressure
regulator on cooktop (1/2” NPT x 1/2” I.D.).
ŶLiquid leak detector or soapy water.
with no less than No. 28 MSG sheet metal
(.015” [.38 mm] thick), .015” (.38 mm) thick
stainless steel, .025” (0.64 mm) aluminum or
.020” (0.5 mm) copper.
DIMENSIONS AND
CLEARANCES
Provide adequate clearances between the
cooktop and adjacent combustible surfaces.
These dimensions must be met for safe use of
your cooktop.
Installation of a listed microwave oven or
cooking appliance over the cooktop shall
conform to the installation instructions packed
with that appliance.
Allow 30” (76.2 cm) minimum clearance
between burners and bottom of unprotected
wood or metal cabinet, or allow a 24” (61
cm) minimum when bottom of wood or metal
cabinet is protected by no less than 1/4” (6.4
mm) thick flame-retardant millboard covered
Built-in oven installation, shall conform to the
installation instruction packed with the built-in
oven.
Safety Glasses
instructions for local inspector’s use.
IMPORTANT
— Observe all governing
codes and ordinances.
IMPORTANT
— Remove all packing
material and literature before connecting gas
and electrical supply to cooktop.
IMPORTANT
— To avoid damage
to your cabinets, check with your builder
or cabinet supplier to make sure that the
materials used will not discolor, delaminate or
sustain other damage. This product has been
designed in accordance with the requirements
of UL and CSA International and complies
with the maximum allowable wood cabinet
temperatures of 194°F (90°C).
Note to Installer – Be sure to leave these
instructions with consumer.
Note to consumer – Keep these instructions
for future reference.
Ǝ0,1FOHDUDQFH
from countertop
to unprotected
overhead surface
L - MIN. clearance from
cooktop to left side wall
30” or 36”
cabinet base
or wider
2-1/2” MIN from cutout
to front of countertop
JGP3030, JGP3530, JGP3036
JGP5030, PGP7030, PGP9030,
CGP9530
JGP5036, PGP7036, PGP9036,
CGP9536
C
2-1/4”
2-7/8”
L
6”
12”
R
6”
12”
3-3/8”
12”
12”
Ǝ
WARNING
COOKTOP
Fire Hazard: Do not use
a flame to check for gas leaks.
WARNING
Do not remove the 6
black Z brackets screwed to the bottom of the
cooktop (on some models).
A. Locate electrical outlet and gas shut-off
valve beneath cabinet.
B. Lay cooktop upside down on a towel or
tablecloth covered countertop.
C. Locate and remove hold-down brackets
from literature package.
D. Attach brackets to cooktop. Remove the
screw from the side of the cooktop and
screw the hold-down bracket to the side of
the cooktop unit. Repeat for opposite side
of cooktop.
E. Insert the cooktop centered into the cutout
opening. Make sure the front edge of the
countertop is parallel to the cooktop.
Make final check that all required
clearances are met.
Once the unit is in place, screw the holddown bracket into the cabinet sides to
secure the unit into place.
Pre-drilled hole
Bottom of Cooktop
Cooktop
Surface
Cooktop
WARNING
Explosion Hazard: Do
not exceed 25 ft-lbs of torque when making
gas line connections. Overtightening may
crack the pressure regulator resulting in fire
or explosion hazard.
Gas Pressure Regulator
You must use the gas pressure regulator supplied
with this range. For proper operations the inlet
pressure to the regulator should be as follows:
Natural Gas:
Minimum pressure: 6” of Water Column
Maximum pressure: 13” of Water Column
Propane Gas:
Minimum pressure: 11” of Water Column
Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure
contact local gas supplier.
Shut off the main gas supply valve before
disconnecting the old cooktop and leave it off
until the new hook-up has been completed.
Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.
Because hard piping restricts movement of
the range, the use of a CSA Internationalcertified flexible metal appliance connector is
recommended unless local codes require a
hard-piped connection.
If the hard piping method is used, you must
carefully align the pipe; the cooktop cannot be
moved after the connection is made.
To prevent gas leaks, apply pipe joint compound
or wrap pipe thread tape with Teflon* around all
male (external) pipe threads.
A. Install provided regulator in the gas line
between the cooktop and manual shut-off
valve. Refer to the arrow on the back of the
regulator for gas flow direction. Ensure the
front of the regulator is facing towards the
cabinet front, easily accessible through the
cabinet doors.
B. Install a manual shut-off valve in the gas line
in a location easily accessible through the
cabinet doors.
C. When all connections have been made,
ensure all gas controls are in the off position
and turn on the main gas supply valve.
Use a liquid leak detector at all joints and
connections to check for leaks in the system.
When using pressures greater than 1/2 psig
to pressure test the gas supply system of
the residence, disconnect the cooktop and
individual shut-off valve from the gas supply
piping. When using pressures of 1/2 psig or
less to pressure test the gas supply system,
simply isolate the cooktop from the gas supply
system by closing the individual shut-off valve.
When checking for proper operation of the
regulator, the inlet pressure must be at least 1”
greater than the operating (manifold) pressure
as given on rating label of product.
*Teflon: Registered trademark of DuPont
D
C. Adapter
C. Adapter
F
E
Ǝ
Ǝ
FOR AMERICANS WITH
DISABILITIES ACT (ADA)
FORWARD APPROACH
INSTALLATION ONLY
1” Min. From Backwall
Recommended
gas supply
location
Ǝ
From
Cutout
Center
Line
5”
Allow 5” minimum depth
between the countertop
and an enclosure.
NOTE: The enclosure must be made of wood
material. Also, an access panel is required for
the electrical outlet, pressure regulator, shut-off
valve, hold-down brackets, and service.
CONVERTING TO PROPANE GAS (OR CONVERTING BACK
TO NATURAL GAS FROM PROPANE)
WARNING
Shock Hazard: This
appliance must be properly grounded.
Failure to do so can result in electric shock.
Electrical Requirements - 120-volt, 60 Hertz,
properly grounded circuit protected by a
15-amp or 20-amp circuit breaker or time delay
fuse. It is recommended that a separate circuit
serving only this cooktop be provided.
NOTE: Use of automatic, wireless, or wired
external switches that shut off power to the
appliance are not recommended for this product.
This cooktop leaves the factory set for use with natural gas. If you want to convert to
propane gas, the conversion must be performed by a qualified propane gas installer.
The conversion orifices and instructions can be found attached to the regulator.
Keep these instructions and all orifices in case you want to convert back to natural gas.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER CORD. DO
NOT USE AN ADAPTER. DO NOT USE AN
EXTENSION CORD.
Ground Fault Circuit Interrupters (GFCI’s) are
not required or recommended for gas cooktop
receptacles. Performance of the cooktop will
not be affected if operated on a GFCI-protected
circuit but occasional nuisance tripping of the
GFCI breaker is possible.
Grounding
The power cord of this appliance is equipped
with a three-prong (grounding) plug which plugs
into a standard three-prong grounding wall
receptacle to minimize the possibility of electric
shock hazard from this appliance.
Ensure proper
ground exists
before use
The customer should have the wall receptacle
and circuit checked by a qualified electrician to
make sure the receptacle is properly grounded.
4 SURFACE BURNERS
5 CHECK SURFACE
BURNERS
Cap
Cap
Determine the quality of flames visually. Normal
burner flames should look like (A) or (B).
(A) Soft blue flames—
Normal for natural gas
(B) Yellow tips on
outer cones—
Normal for propane gas
Long, bright yellow flames are not normal.
Normal flames may show signs of an orange
tint when well heated or signs of flickering
orange due to particles in the gas or air.
WHEN ALL HOOKUPS ARE
COMPLETED
Check that all packing materials and tape have
been removed. This will include adhesive tape,
wire ties, cardboard and protective plastic.
Failure to remove these materials could result
in damage to the appliance once the appliance
has been turned on and surfaces have heated.
INSTALLATION AT HIGH ALTITUDE
or
WARNING
Quality of Flames
Push and turn a knob to the LITE position. A
clicking sound indicates proper operation of
the ignition system. When lighting any burner,
sparks will appear at all burners but gas flows
from only the one selected. Once air is purged
from the supply line, burner should light within
4 seconds. After burner lights, rotate the knob
out of the LITE position. Try each burner in
succession until all burners have been checked.
Make sure all controls are left in the off
position. Make sure the flow of combustion and
ventilation air to the cooktop is unobstructed.
Cap
Over 6000ft, product configured for natural gas or propane requires installation of kit
:%;IRUQDWXUDOJDVDQG:%;IRUSURSDQHJDV )ROORZWKHLQVWUXFWLRQV
included with the kit.
Burner
Burner
Electrode
C. Grates - Place the grates on the cooktop.
B. Regulator provided with
unit:
C
• Outlet - 3/8” NPT
female pipe thread
• Inlet - 1/2” NPT female D
pipe thread
E. Adapter
CONNECTIONS
ALTERNATE INSTALLATION WITH
OBSTRUCTION BELOW COOKTOP
A. 3/8” NPT male pipe thread
D. Flexible connector
19-1/8” width cut
33-7/8”
length
of cut
B. Caps - Place caps on proper size burner.
A
B
C
B
3 ELECTRICAL
A. Burners - Place surface burners into
corresponding positions on cooktop.
TYPICAL INSTALLATION WITH NO
OBSTRUCTION BELOW COOKTOP
A
36” Models
DRAWER
DRAWER
Fire or Explosion Hazard:
Do not operate the burner without all burner
parts in place.
CONNECTOR HOOKUP
A. 3/8” NPT male pipe
thread
19-5/8” width cut
Ǝ
For island installation, maintain 2-1/2 in. minimum from cutout to front
and back edge of countertop. Maintain 3 in. minimum from cutout to
side edges of countertop.
2 GAS SUPPLY
Ǝ
Ǝ
CUTOUT DIMENSIONS OF COUNTERTOP
RECOMMENDED GAS
SUPPLY LOCATION FROM
BACKWALL
Ǝ0,1KHLJKW
from countertop to
nearest cabinet on
either side of unit
C - MIN. clearance
from cutout to rear wall
ALL HORIZONTAL
CLEARANCES MUST
BE MAINTAINED FOR A
MINIMUM OF 18” ABOVE
THE COOKING SURFACE.
Ǝ
Cooktop
R - MIN. clearance
from cutout to right
3 3/4wall
MIN.
side
NOTE: Allow 7/16” minimum vertical clearance from the cooktop
bottom (or 3-11/16” minimum depth from the countertop) to any
combustible surfaces, such as a cabinet drawer.
1 INSTALLING THE
Ǝ
Ǝ
Ǝ
Ǝ
Ǝ
Cooktop
28-1/2”
length
of cut
MAINTAIN THE FOLLOWING MINIMUM CLEARANCE
DIMENSIONS
Servicer – The electrical diagram is located
inside the cooktop.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is
not covered under warranty.
Mobile Home - Additional Installation
Requirements
The installation of this product must conform
to the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile
Home Construction and Saftey, Title 24,
HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A
or with local codes.
In Canada, the installation of this product must
conform with the current standards CAN/CSAA240-latest edition, or with local codes.
When this cooktop is installed in a mobile home,
it must be secured during transit. Any method of
securing the cooktop is adequate as long as it
conforms to the standards listed above.
36” Models
Ǝ
Ǝ
30” Models
Ǝ0$;'HSWK
of unprotected
overhead cabinets
BEFORE YOU BEGIN
IMPORTANT — Save these
30” Models
To ensure accuracy, it is best to make a template when cutting the opening in the counter.
*Teflon: Registered trademark of DuPont
Ǝ'ULOO%LW (OHFWULF
or Hand Drill
OVERALL COOKTOP DIMENSIONS
Electrode
Multi-ring
B. Elbow
Grates
(on some models)
Grates
(on some models)
D. Flexible connector (allows
passage through cabinet wall)
E. Adapter
E
G
F. Regulator provided with unit:
• Outlet - 3/8” NPT female pipe
thread
• Inlet - 1/2” NPT female pipe
thread
F. Manual shut-off valve
F
H
G. Gas pipe
G. Gas pipe 1/2” or 3/4”
G
I
H. Manual shut-off valve
I. Gas pipe 1/2” or 3/4”
INSTALLATION INSTRUCTION
31-11089 07-17 GEA
JGP3030, JGP3530, JGP5030, PGP7030, PGP9030, CGP9530
JGP3036, JGP5036, PGP7036, PGP9036, CGP9536
Instrucciones de instalación
Superficies de Cocción a Gas
¿Preguntas? Llame a GE Appliances al 800.GE.CARES (800.432.2737) o visita
www.GEAppliances.com. En Canadá, llame 1.800.561.3344 o visita www.GEAppliances.ca.
EN EL COMMONWEALTH DE
MASSACHUSETTS
Ŷ(VWHSURGXFWRGHEHVHULQVWDODGRSRUXQSORPHUR
OLFHQFLDGRRXQPHFiQLFRJDVLVWD
ADVERTENCIA
RIESGO DE INCENDIO O
EXPLOSIÓN
6LODLQIRUPDFLyQTXHILJXUDHQHVWDVLQVWUXFFLRQHVQR
VHVLJXHH[DFWDPHQWHVHSRGUiSURGXFLUXQLQFHQGLR
RH[SORVLyQRFDVLRQDQGRGDxRVVREUHODSURSLHGDG
OHVLRQHVRODPXHUWH
/DLQVWDODFLyQGHEHUiQVHUUHDOL]DGDVSRUXQ
LQVWDODGRUFDOLILFDGR
/HDHVWDVLQVWUXFFLRQHVHQVXWRWDOLGDG\DWHQWDPHQWH
/DLQVWDODFLyQGHHVWHSURGXFWRGHEHVHUUHDOL]DGDGH
DFXHUGRFRQORVFyGLJRVORFDOHVRHQODDXVHQFLDGH
FyGLJRVORFDOHVFRQHO&yGLJRGH*DV&RPEXVWLEOH
1DFLRQDO$16,=1)3$~OWLPDHGLFLyQ(Q
&DQDGiODLQVWDODFLyQGHEHUiVHUFRQIRUPHFRQHO
&yGLJRGH,QVWDODFLyQGH*DV1DWXUDODFWXDO&$1
&*$%RHO&yGLJRGH,QVWDODFLyQGH3URSDQR
DFWXDO&$1&*$%\FRQORVFyGLJRVORFDOHV
FXDQGRFRUUHVSRQGD(OGLVHxRGHHVWHSURGXFWRIXH
FHUWLILFDGRSRU8/GHDFXHUGRFRQ$16,=~OWLPD
Ŷ$OXVDUYiOYXODVGHFLHUUHGHJDVWLSREDOyQ
GHEHUiQVHUGHOWLSRGHPDQLMD7
HERRAMIENTAS NECESARIAS
/ODYHFRQH[WUHPR
DELHUWRRDMXVWDEOH
Ŷ$OXVDUXQFRQHFWRUGHJDVIOH[LEOHQRGHEHUi
H[FHGHUORVSLHV
/DVXSHUILFLHGHFRFFLyQGHEHUiHVWDUHOpFWULFDPHQWH
FRQHFWDGDDWLHUUDGHDFXHUGRFRQORVFyGLJRVORFDOHV
RHQDXVHQFLDGHFyGLJRVORFDOHVGHDFXHUGRFRQ
HO&yGLJR1DFLRQDOGH(OHFWULFLGDG 1DWLRQDO(OHFWULF
&RGH $16,1)3$12~OWLPDHGLFLyQ (Q
&DQDGiODFRQH[LyQDWLHUUDVHGHEHUiUHDOL]DUGH
DFXHUGRFRQOD3DUWHGHO&yGLJRGH(OHFWULFLGDGGH
&DQDGi&6$&\RORVFyGLJRVORFDOHV(QHVWD
VHFFLyQFRQVXOWHODV&RQH[LRQHV(OpFWULFDV
1RLQVWDOHHVWHSURGXFWRFRQXQDFDPSDQDFRQFRUWLQD
GHDLUHXRWUDFDPSDQDSDUDVXSHUILFLHVGHFRFFLyQ
TXHIXQFLRQHOOHYDQGRDLUHDODVXSHUILFLHGHFRFFLyQ(O
IOXMRGHDLUHSRGUiLQWHUIHULUHQHOIXQFLRQDPLHQWRGHORV
TXHPDGRUHVGHJDVSURGXFLHQGRULHVJRVGHLQFHQGLR
RH[SORVLyQ
Ŷ$GDSWDGRUSDUDXQLyQFyQLFDSDUDODFRQH[LyQDO
VXPLQLVWURGHJDV ´Rò´137[ò´,' Ŷ$GDSWDGRUSDUDXQLyQFyQLFDSDUDODFRQH[LyQDO
UHJXODGRUGHSUHVLyQGHODVXSHUILFLHGHFRFFLyQ
´Rò´137[ò´,' *DIDVGH6HJXULGDG
7HIOyQ0DUFDUHJLVWUDGDSRU'X3RQW
%URFD\7DODGUR(OpFWULFR
R0DQXDOGH´
ANTES DE COMENZAR
IMPORTANTE²&RQVHUYHHVWDVLQVWUXFFLRQHV
SDUDXVRGHOLQVSHFWRUGHHOHFWULFLGDGORFDO
FyGLJRV\RUGHQDQ]DVJXEHUQDPHQWDOHV
IMPORTANTE²5HWLUHWRGRVORVPDWHULDOHV
GHOHPEDODMH\ODVLQVWUXFFLRQHVDQWHVGHFRQHFWDUHO
VXPLQLVWURGHJDV\HOpFWULFRDODVXSHUILFLHGHFRFFLyQ
IMPORTANTE²$ILQGHHYLWDUGDxRV
HQORVJDELQHWHVFRQWUROHFRQVXFRQVWUXFWRUR
SURYHHGRUGHJDELQHWHVTXHORVPDWHULDOHVXVDGRVQR
GHVFRORUDUiQGHVODPLQDUiQQLVRVWHQGUiQRWURGDxR
(VWHSURGXFWRKDVLGRGLVHxDGRGHDFXHUGRFRQORV
UHTXLVLWRVGH8/\&6$,QWHUQDWLRQDO\FXPSOHFRQ
ODVWHPSHUDWXUDVPi[LPDVSHUPLWLGDVSDUDJDELQHWHV
GHPDGHUDGHž) ž& &XDQGRODVXSHUILFLHGHFRFFLyQVHDLQVWDODGDHQ
XQDFDVDPyYLOVHGHEHUiDMXVWDUGHIRUPDVHJXUD
GXUDQWHHOWUiQVLWR&XDOTXLHUPpWRGRSDUDDVHJXUDU
ODVXSHUILFLHGHFRFFLyQHVDGHFXDGRVLHPSUH\
FXDQGRVHUHDOLFHFRQIRUPHFRQORVHVWiQGDUHVTXH
ILJXUDQPiVDUULED
$QWHVGHFRPHQ]DUODLQVWDODFLyQDSDJXHHOHQFHQGLGRHQHOSDQHOGH
VHUYLFLR\EORTXHHHOPHGLRGHGHVFRQH[LyQGHOVHUYLFLRDILQGHHYLWDUTXHHOHQFHQGLGRVHDFWLYHGHIRUPD
DFFLGHQWDO&XDQGRHOPHGLRGHGHVFRQH[LyQGHOVHUYLFLRQRVHSXHGDEORTXHDUDMXVWHGHPDQHUDVHJXUDXQ
tWHPGHDGYHUWHQFLDTXHHVWpELHQYLVLEOHWDOFRPRXQDHWLTXHWDVREUHHOSDQHOGHVHUYLFLR
Modelos
de 36”
Ǝ
Ǝ
Ǝ
6XSHUILFLHGH&RFFLyQ
Ǝ
Ǝ
/DLQVWDODFLyQGHOKRUQRHPSRWUDEOHGHEHUiVHU
UHDOL]DGDGHDFXHUGRFRQODVLQVWUXFFLRQHVGH
LQVWDODFLyQDGMXQWDVFRQHOKRUQRHPSRWUDEOH
Ǝ
Ǝ
Ǝ
6XSHUILFLHGH&RFFLyQ
Ǝ
Ǝ
DIMENSIONES DE ENCASTRE DE LA MESADA
´GHSURIXQGLGDG
0È;,0$GHEDMRGH
JDELQHWHVGHVSURWHJLGRV
Modelos
de 30”
/RQJLWXG
GHFRUWH
GH´
&RUWHGHDQFKR
GH´
&RUWHGHDQFKR
GH´
/RQJLWXG
GHFRUWH
GH´
Ǝ
´GHDOWXUDPtQLPDGHVGH
ODPHVDGDKDVWDHOJDELQHWH
PiVFHUFDQRVREUHFXDOTXLHUD
GHORVODGRVGHODXQLGDG
UBICACIÓN DEL SUMINISTRO
DE GAS RECOMENDADA
DESDE LA PARED TRASERA
C'HVSHMHPtQLPRGHVGHOD
DSHUWXUDKDVWDODSDUHGWUDVHUD
L'HVSHMHPtQLPRGHVGHOD
VXSHUILFLHGHFRFFLyQKDVWDOD
SDUHGGHOODGRL]TXLHUGR
Ǝ
´FRPRPtQLPRGHVGHOD3DUHG7UDVHUD
8ELFDFLyQGHO
VXPLQLVWUR
GHJDV
UHFRPHQGDGD
Ǝ
'HVGH
OD/tQHD
&HQWUDOGH
&RUWH
%DVHGHO
JDELQHWHGH
´R´R
PiVDQFKD
0tQLPRGH´GHVGHODDSHUWXUD
KDVWDHOIUHQWHGHODPHVDGD
SE DEBERÁN MANTENER
TODOS LOS DESPEJES
HORIZONTALES POR UN
MÍNIMO DE 18” SOBRE LA
SUPERFICIE DE COCCIÓN.
Modelos
de 36”
D'HVSHMHPtQLPRGHVGH
ODDSHUWXUDKDVWDODSDUHG
3 3/4 MIN.
GHOODGRGHUHFKR
´GHGHVSHMH
PtQLPRGHVGHOD
PHVDGDKDVWDXQD
VXSHUILFLHVXSHULRU
GHVSURWHJLGD
/DFRUUHFWDLQVWDODFLyQGHOSURGXFWRHV
UHVSRQVDELOLGDGGHOLQVWDODGRU
(Q&DQDGiODLQVWDODFLyQGHHVWDFRFLQDGHEHUiVHU
UHDOL]DGDGHDFXHUGRFRQORVHVWiQGDUHVDFWXDOHV&$1
&6$$±~OWLPDHGLFLyQRFRQORVFyGLJRVORFDOHV
DIMENSIONES GENERALES DE LA SUPERFICIE DE COCCIÓN
Modelos
de 30”
/DLQVWDODFLyQGHXQKRUQRPLFURRQGDVRGHXQ
HOHFWURGRPpVWLFRGHFRFFLyQTXHILJXUHQHQODOLVWD
VREUHODSDUWHVXSHULRUGHODVXSHUILFLHGHFRFFLyQ
GHEHUiFXPSOLUFRQODVLQVWUXFFLRQHVGHLQVWDODFLyQ
SURYLVWDVFRQHOHOHFWURGRPpVWLFR
MANTENGA LAS SIGUIENTES DIMENSIONES MÍNIMAS DE
DESPEJE
Servicio Técnico±(OGLDJUDPDHOpFWULFRHVWiXELFDGR
GHQWURGHODVXSHUILFLHGHFRFFLyQ
/DLQVWDODFLyQGHHVWHSURGXFWRGHEHUiVHUUHDOL]DGD
GHDFXHUGRFRQHO(VWiQGDUGH&RQVWUXFFLyQ
\6HJXULGDGSDUD+RJDU7tWXOR&)53LH]D
DQWHULRUPHQWHHO(VWiQGDU)HGHUDOSDUDOD
&RQVWUXFFLyQ\6HJXULGDGGH&DVDV5RGDQWHV
)HGHUDO6WDQGDUGIRU0RELOH+RPH&RQVWUXFWLRQDQG
6DIHW\ 7tWXOR+8'3DUWH &XDQGRGLFKR
HVWiQGDUQRVHDDSOLFDEOHXVHHOHVWiQGDUSDUDODV
,QVWDODFLRQHVGH&DVDV)DEULFDGDV
$16,$1)3$$RFRQFyGLJRVORFDOHV
PHWiOLFDGH06* ´ PP GHJURVRU ´ PP GHJURVRUGHDFHURLQR[LGDEOH´
PP GHDOXPLQLRR´ PP GHFREUH
3DUDDVHJXUDUODSUHFLVLyQHVPHMRUUHDOL]DUXQDSODQWLOODDOFRUWDUODDEHUWXUDGHODPHVDGD
Casa Rodante – Requisitos de Información
Adicional
Nota para el Consumidor±*XDUGHHVWDV
LQVWUXFFLRQHVSDUDUHIHUHQFLDIXWXUD
ADVERTENCIA
'HMHXQHVSDFLRPtQLPRGH´ FP HQWUH
ORVTXHPDGRUHV\ODSDUWHLQIHULRUGHOJDELQHWHGH
PDGHUDRPHWDOVLQSURWHFFLyQRGHMHXQHVSDFLR
PtQLPRGH´ FP FXDQGRODSDUWHLQIHULRUGHO
JDELQHWHGHPDGHUDRPHWDOHVWpSURWHJLGRSRUQR
PHQRVGH´ PP GHFDUWyQGHUHWDUGRGH
LQFHQGLRVFXELHUWDSRUQRPHQRVTXHXQDOiPLQD
6LVHSURGXFHQIDOODVHQHOSURGXFWRGHELGRDXQD
LQVWDODFLyQLQDGHFXDGDOD*DUDQWtDQRFXEULUiODV
PLVPDV
IMPORTANTE²&XPSODFRQWRGRVORV
Nota para el Instalador±$VHJ~UHVHGHTXHHVWDV
LQVWUXFFLRQHVTXHGHQHQPDQRVGHOFRPSUDGRU
PARA SU SEGURIDAD
'HMHHOHVSDFLRDGHFXDGRHQWUHODVXSHUILFLHGH
FRFFLyQ\ODVVXSHUILFLHVFRPEXVWLEOHVDG\DFHQWHV
(VWDVGLPHQVLRQHVVHGHEHUiQFXPSOLUSDUDXQXVR
VHJXURGHODVXSHUILFLHGHFRFFLyQ
Ŷ'HWHFWRUGHSpUGLGDGHOtTXLGRRDJXDFRQMDEyQ
HGLFLyQ\FRQOD&DQDGLDQ*DV$VVRFLDWLRQ $VRFLDFLyQ
GH*DVGH&DQDGi &$1&*$~OWLPDHGLFLyQ
/DSUXHEDGHJRWHUDVGHOHOHFWURGRPpVWLFRVH
GHEHUiUHDOL]DUGHDFXHUGRFRQODVLQVWUXFFLRQHVGHO
IDEULFDQWH
Ŷ9iOYXODGHFLHUUHSDUDWXEHUtDGHJDV
Ŷ&RQHFWRUSDUDDUWHIDFWRPHWiOLFRIOH[LEOH ´,' 6HUHFRPLHQGDXQDORQJLWXGGHSLHVSDUDXQD
IiFLOLQVWDODFLyQSHURRWUDVORQJLWXGHVVRQ
DFHSWDEOHV1XQFDXVHXQFRQHFWRUYLHMRDOLQVWDODU
XQDVXSHUILFLHGHFRFFLyQQXHYD
6LHUUDGH
9DLYpQ
/ODYHSDUDWXEHUtD XQDGHUHSXHVWR
/iSL]\UHJOD
$OLQVWDODUXQHOHFWURGRPpVWLFRDJDVHOXVRGH
FRQHFWRUHVIOH[LEOHVYLHMRVSXHGHRFDVLRQDUSpUGLGDV
\OHVLRQHVSHUVRQDOHV6LHPSUHXVHXQFRQHFWRU
IOH[LEOH18(92
DIMENSIONES Y ESPACIOS
Ŷ6HOODGRUSDUDMXQWDGHWXEHUtDR8/±FLQWDSDUD
WXEHUtDDSUREDGDFRQ7HIOyQ UHVLVWHQWHDODDFFLyQ
GHJDVHVQDWXUDOHVRSURSDQR
'HVWRUQLOODGRU
3KLOLSV
'HVWRUQLOODGRUFRQ
FDEH]DSODQD
MATERIALES NECESARIOS
C
I
D
JGP3030, JGP3530, JGP3036
´
´
´
JGP5030, PGP7030, PGP9030,
CGP9530
´
´
´
JGP5036, PGP7036, PGP9036,
CGP9536
´
´
´
´
'HMHXQDSURIXQGLGDGGH
SRUORPHQRV´HQWUHOD
PHVDGD\ODFXELHUWD
NOTA: /DFXELHUWDGHEHUiHVWDUKHFKDGH
PDWHULDOGHPDGHUD$GHPiVXQSDQHOGHDFFHVR
HVQHFHVDULRSDUDODWRPDGHFRUULHQWHUHJXODGRU
GHSUHVLyQYiOYXODGHFLHUUHORVVRSRUWHVGHORV
FRVWDGRV\HOVHUYLFLRWpFQLFR
Ǝ
Ǝ
NOTA:'HMHXQHVSDFLRYHUWLFDOGHSRUORPHQRV´GHVGHODSDUWHLQIHULRUGH
ODVXSHUILFLHGHFRFFLyQ RXQDSURIXQGLGDGGHSRUORPHQRV´GHVGHOD
PHVDGD KDVWDFXDOTXLHUVXSHUILFLHFRPEXVWLEOHWDOFRPRHOFDMyQGHXQJDELQHWH
INSTALACIÓN POR
DELANTE ÚNICAMENTE DE
ACUERDO CON LA LEY DE
ESTADOUNIDENSES CON
INCAPACIDADES (ADA)
&$-Ï1
DRAWER
3DUDODLQVWDODFLyQGHODLVODGHMHXQHVSDFLRPtQLPRGHò´HQWUHODDEHUWXUD\
HOH[WUHPRIURQWDO\WUDVHURGHODPHVDGD'HMHXQPtQLPRGH´HQWUHODDEHUWXUD
\ORVH[WUHPRVODWHUDOHVGHODPHVDGD
CONVERTIR A GAS PROPANO (O VOLVER A CONVERTIR DE
PROPANO A GAS NATURAL)
Esta superficie de cocción deja la configuración de fábrica para uso con gas natural. Si desea convertir
a gas propano, la conversión deberá ser realizada por un instalador de gas propano calificado.
/RVRULILFLRVGHFRQYHUVLyQ\ODVLQVWUXFFLRQHVSRGUiQVHUHQFRQWUDGDVDGMXQWDVFRQHOUHJXODGRU
*XDUGHHVWDVLQVWUXFFLRQHV\WRGRRULILFLRVHQFDVRGHTXHORGHVHHFRQYHUWLUQXHYDPHQWHDJDVQDWXUDO
1
2
INSTALACIÓN DE LA
SUPERFICIE DE COCCIÓN
ADVERTENCIA
Riesgo de incendio:
No use una llama para controlar las pérdidas de gas.
ADVERTENCIA
1RUHWLUHORV
VRSRUWHV=QHJURVDWRUQLOODGRVDODSDUWHLQIHULRUGH
ODVXSHUILFLHGHFRFFLyQ HQDOJXQRVPRGHORV $8ELTXHHOWRPDFRUULHQWHHOpFWULFR\ODYiOYXODGH
FLHUUHGHJDVGHEDMRGHOJDELQHWH
0DUFDSDUDUHDOL]DUDJXMHUR
3DUWHLQIHULRUGHOD
VXSHUILFLHGHFRFFLyQ
%&RORTXHODVXSHUILFLHGHFRFFLyQDOUHYpVVREUH
XQDPHVDGDFXELHUWDSRUXQDWRDOODRPDQWHO
&8ELTXH\UHWLUHORVVRSRUWHVGHORVFRVWDGRVGHO
SDTXHWHGHLQVWUXFFLRQHV
'$GKLHUDORVVRSRUWHVDODVXSHUILFLHGHFRFFLyQ
5HWLUHHOWRUQLOORGHOFRVWDGRGHODVXSHUILFLHGH
FRFFLyQ\DWRUQLOOHHOVRSRUWHDOFRVWDGRGHOD
XQLGDGGHODVXSHUILFLHGHFRFFLyQ5HSLWDHVWRHQ
HOODGRRSXHVWRGHODVXSHUILFLHGHFRFFLyQ
(,QVHUWHODVXSHUILFLHGHFRFFLyQFHQWUDGDVREUH
ODDEHUWXUDGHOHQFDVWUH$VHJ~UHVHGHTXHHO
H[WUHPRIURQWDOGHODPHVDGDHVWpSDUDOHORDOD
VXSHUILFLHGHFRFFLyQ+DJDHOFRQWUROILQDOSDUD
YHULILFDUTXHVHFXPSODFRQWRGRVORVHVSDFLRVGH
GHVSHMHQHFHVDULRV
8QDYH]FRORFDGDODXQLGDGDWRUQLOOHHOVRSRUWH
VREUHORVFRVWDGRVGHOJDELQHWHSDUDDVHJXUDUOD
XQLGDGHQVXXELFDFLyQ
$ILQGHHYLWDUSpUGLGDVGHJDVFRORTXHHOFRPSXHVWR
GHODMXQWDGHJDVRHQYXHOYDODFLQWDSDUDURVFDVGH
WXEHUtDVFRQ7HIOyQ DOUHGHGRUGHWRGDVODVURVFDVGH
WXEHUtDPDFKR H[WHUQDV SUMINISTRO DE GAS
(VSDFLRGHOD
VXSHUILFLHGH
FRFFLyQ
6XSHUILFLHGH
&RFFLyQ
ADVERTENCIA
Riesgo de
Explosión: No supere una torsión máxima de 25
pies-libras al realizar conexiones de tuberías de
gas. Cualquier ajuste en exceso podrá romper
el regulador de presión, resultando en riesgo de
incendio o explosión.
Regulador de Presión de Gas
6HGHEHUiXVDUHOUHJXODGRUGHSUHVLyQGHJDV
VXPLQLVWUDGRFRQHVWDFRFLQD3DUDXQIXQFLRQDPLHQWR
DGHFXDGRODSUHVLyQGHHQWUDGDDOUHJXODGRUGHEHUi
VHUODVLJXLHQWH
Gas Natural:
3UHVLyQPtQLPD&ROXPQDGH$JXDGH´
3UHVLyQPi[LPD&ROXPQDGH$JXDGH´
Gas Propano:
3UHVLyQPtQLPD&ROXPQDGH$JXDGH´
3UHVLyQPi[LPD&ROXPQDGH$JXDGH´
6LQRHVWiVHJXURVREUHFXiOHVODSUHVLyQGHHQWUDGD
FRPXQtTXHVHFRQHOSURYHHGRUGHJDVORFDO
Cierre la válvula principal de suministro de gas
antes de desconectar su vieja superficie de cocción
y deje la misma apagada hasta que la nueva
conexión se haya completado. No olvide volver a
encender el piloto en otros electrodomésticos a gas
cuando vuelva a encender el gas.
'HELGRDTXHODVWXEHUtDVGXUDVUHVWULQJHQHO
PRYLPLHQWRGHODFRFLQDVHUHFRPLHQGDHOXVRGHO
FRQHFWRUSDUDHOHFWURGRPpVWLFRVGHPHWDOIOH[LEOHFRQ
FHUWLILFDFLyQLQWHUQDFLRQDOGH&6$DPHQRVTXHORV
FyGLJRVORFDOHVUHTXLHUDQXQDFRQH[LyQGHWXEHUtDGXUD
$ ,QVWDOHHOUHJXODGRUSURYLVWRHQODWXEHUtDGH
JDVHQWUHODVXSHUILFLHGHFRFFLyQ\ODYiOYXOD
GHFLHUUHPDQXDO&RQVXOWHODIOHFKDHQODSDUWH
WUDVHUDGHOUHJXODGRUSDUDFRQRFHUODGLUHFFLyQ
GHOIOXMRGHJDV$VHJ~UHVHGHTXHODSDUWHIURQWDO
GHOUHJXODGRUHVWpPLUDQGRKDFLDHOIUHQWHGHO
JDELQHWHIiFLOPHQWHDFFHVLEOHDWUDYpVGHODV
SXHUWDVGHOJDELQHWH
% ,QVWDOHXQDYiOYXODGHFLHUUHPDQXDOHQODWXEHUtD
GHJDVHQXQDXELFDFLyQGHIiFLODFFHVRDWUDYpV
GHODVSXHUWDVGHOJDELQHWH
& 8
QDYH]UHDOL]DGDVWRGDVODVFRQH[LRQHVDVHJ~UHVH
GHTXHWRGRVORVFRQWUROHVGHJDVHVWpQHQOD
SRVLFLyQGHDSDJDGR\HQFLHQGDODYiOYXODGH
VXPLQLVWURSULQFLSDOGHJDV8VHXQGHWHFWRU
GHSpUGLGDGHOtTXLGRHQWRGDVODVXQLRQHV\
FRQH[LRQHVDILQGHFRQWURODUSpUGLGDVHQHOVLVWHPD
$OXVDUSUHVLyQVXSHULRUDòSVLJSDUDFRQWURODU
ODSUHVLyQGHOVLVWHPDGHVXPLQLVWURGHJDVGHOD
UHVLGHQFLDGHVFRQHFWHODVXSHUILFLHGHFRFFLyQ\OD
YiOYXODGHFLHUUHLQGLYLGXDOGHODWXEHUtDGHVXPLQLVWUR
GHJDV$OXVDUODVSUHVLRQHVGHSUXHEDGHòSVLJ
RPHQRVSDUDFRQWURODUHOVLVWHPDGHVXPLQLVWURGH
JDVVLPSOHPHQWHDtVOHODVXSHUILFLHGHFRFFLyQGHO
VLVWHPDGHVXPLQLVWURGHJDVFHUUDQGRODYiOYXODGH
FLHUUHLQGLYLGXDO
$OFRQWURODUHOIXQFLRQDPLHQWRDGHFXDGRGHOUHJXODGRU
ODSUHVLyQGHHQWUDGDGHEHUiVHUSRUORPHQRV´
PD\RUTXHODSUHVLyQGHIXQFLRQDPLHQWR WXER FRPR
HQODHWLTXHWDGHFDOLILFDFLyQGHOSURGXFWR
7HIOyQ0DUFDUHJLVWUDGDSRU'X3RQW
6LVHXVDHOPpWRGRGHWXEHUtDGXUDGHEHUiDOLQHDU
ODPLVPDFRQFXLGDGRODVXSHUILFLHGHFRFFLyQQRVH
SRGUiPRYHUXQDYH]UHDOL]DGDODFRQH[LyQ
,167$/$&,Ï17Ë3,&$6,12%6758&&,21(6
'(%$-2'(/$683(5),&,('(&2&&,Ï1
$
% 5HJXODGRUSURYLVWRFRQ
%
ODXQLGDG
‡ 6DOLGD5RVFDKHPEUD
GHWXEHUtD137GH´
C
‡ (QWUDGD±5RVFD
KHPEUDGHWXEHUtD137
GH´
'
& $GDSWDGRU
( $GDSWDGRU
) 9iOYXODGHFLHUUHPDQXDO
* 7XEHUtDGHJDVGH
´R´
,167$/$&,Ï1$/7(51$7,9$&212%6758&&,21(6
'(%$-2'(/$683(5),&,('(&2&&,Ï1
$
%
C
'
(
ADVERTENCIA
(QFDVRGHFRQWDUFRQXQWRPDFRUULHQWHGHSDUHGGH
FDEOHVHVODUHVSRQVDELOLGDG\REOLJDFLyQGHOFOLHQWH
UHHPSOD]DUORSRUXQWRPDFRUULHQWHGHSDUHGGH
FDEOHVFRUUHFWDPHQWHFRQHFWDGRDWLHUUD
Riesgo de
Descarga: Este electrodoméstico deberá estar
conectado a tierra de forma adecuada. Si no cumple
con esto se podrán producir descargas eléctricas.
NUNCA, BAJO NINGUNA CIRCUNSTANCIA,
CORTE NI ELIMINE EL TERCER CABLE (TIERRA)
DEL CABLE DE CORRIENTE. NO USE UN
ADAPTADOR. NO USE UN PROLONGADOR.
Requisitos Eléctricos - &LUFXLWRGHYROWLRV
+HUW]FRUUHFWDPHQWHFRQHFWDGRDWLHUUDSRUXQ
GLV\XQWRUGHRDPSHUHVRIXVLEOHGHUHWUDVR
6HUHFRPLHQGDFRQWDUFRQXQFLUFXLWRVHSDUDGRTXH
VHXVH~QLFDPHQWHFRQHVWDVXSHUILFLHGHFRFFLyQ
1RVHUHTXLHUHQQLVHUHFRPLHQGDQ,QWHUUXSWRUHVFRQ
'HWHFFLyQGH)DOODD7LHUUD *)&, HQUHFHSWiFXORVGH
VXSHUILFLHVGHFRFFLyQDJDV(OIXQFLRQDPLHQWRGHOD
VXSHUILFLHGHFRFFLyQQRVHYHUiDIHFWDGRVLVHXWLOL]D
HQXQFLUFXLWR*)&,SURWHJLGRSHURHVSRVLEOHTXHVH
SURGX]FDQGHWHQFLRQHVRFDVLRQDOHVQRGHVHDGDVGHO
LQWHUUXSWRUGHO*)&,
NOTA: 1RVHUHFRPLHQGDSDUDHVWHSURGXFWRHO
XVRGHLQWHUUXSWRUHVDXWRPiWLFRVLQDOiPEULFRVR
FRQFDEOHDGRH[WHUQRTXHDSDJDQODFRUULHQWHGHO
HOHFWURGRPpVWLFR
& $GDSWDGRU
Calidad de las Llamas
CONTROLE LAS CABEZAS
DE LOS QUEMADORES
3UHVLRQH\JLUHODSHULOODDODSRVLFLyQ/,7( /X] 8Q
VRQLGRGHFOLFLQGLFDHOFRUUHFWRIXQFLRQDPLHQWRGHO
VLVWHPDGHHQFHQGLGR$OLOXPLQDUFXDOTXLHUTXHPDGRU
VHSURGXFLUiQFKLVSDVHQWRGRVORVTXHPDGRUHVSHUR
VyORVDOGUiJDVGHOTXHIXHVHOHFFLRQDGR8QDYH]
TXHHODLUHVHKD\DSXUJDGRGHODOtQHDGHVXPLQLVWUR
HOTXHPDGRUVHGHEHUiHQFHQGHUGHQWURGHORV
VHJXQGRV/XHJRGHTXHHOTXHPDGRUVHHQFLHQGD
JLUHODSHULOODIXHUDGHODSRVLFLyQ/,7( /X] 3UXHEH
FDGDTXHPDGRUGHIRUPDVXFHVLYDKDVWDTXHWRGRVORV
TXHPDGRUHVKD\DQVLGRFRQWURODGRV
Conexión a Tierra
(OFDEOHGHFRUULHQWHGHHVWHHOHFWURGRPpVWLFRFXHQWD
FRQXQHQFKXIHGHSDWDV FRQH[LyQDWLHUUD TXH
VHFRQHFWDDXQWRPDFRUULHQWHGHSDUHGHVWiQGDUGH
FDEOHVSDUDPLQLPL]DUODSRVLELOLGDGGHULHVJRVGH
GHVFDUJDVHOpFWULFDVSRUSDUWHGHOPLVPR
$VHJ~UHVHGH
FRQWDUFRQXQD
FRQH[LyQDWLHUUD
DGHFXDGDDQWHV
GHXVDU
(OFOLHQWHGHEHUiFRQWUDWDUDXQHOHFWULFLVWDFDOLILFDGR
SDUDTXHFRQWUROHHOFLUFXLWRDILQGHDVHJXUDUTXHHO
WRPDFRUULHQWHHVWpFRUUHFWDPHQWHFRQHFWDGRDWLHUUD
4
ADVERTENCIA
& Rejillas -&RORTXHODVUHMLOODVHQODSODFDGH
FRFFLyQ
'HWHUPLQHODFDOLGDGGHODVOODPDVGHIRUPDYLVXDO
/DVOODPDVQRUPDOHVGHORVTXHPDGRUHVVHGHEHUiQ
YHUFRPR $ R % (A) Llamas azul suave —
1RUPDOSDUDJDVQDWXUDO
(B) Puntas amarillas en
conos externos — 1RUPDO
SDUDHOJDVSURSDQR
/DVOODPDVODUJDVGHFRORUDPDULOOREULOODQWHQRVRQ
QRUPDOHV/DVOODPDVQRUPDOHVSRGUiQPRVWUDUVLJQRV
GHXQWLQWHDQDUDQMDGRFXDQGRHVWpQELHQTXHPDGDV
RVLJQRVGHDQDUDQMDGRSDUSDGHDQWHGHELGRDODV
SDUWtFXODVGHOJDVRGHODLUH
$VHJ~UHVHTXHWRGRVORVPDWHULDOHVGHHPSDTXH\
FLQWDVVHKD\DQUHWLUDGR(VWRLQFOXLUiFLQWDDGKHVLYD
QXGRVGHFDEOHVFDUWyQ\SOiVWLFRVSURWHFWRUHV6L
HVWRVPDWHULDOHVQRVHUHWLUDQVHSRGUiSURGXFLU
FRPRUHVXOWDGRXQGDxRVREUHHOHOHFWURGRPpVWLFR
XQDYH]TXHHOPLVPRKD\DVLGRHQFHQGLGR\ODV
VXSHUILFLHVHVWpQFDOLHQWHV
7DSD
7DSD
R
Riesgo de Incendio
o Explosión: No use el quemador sin que todas
las partes de los quemadores estén en sus
respectivos lugares.
$ Q
uemadores -&RORTXHODVFDEH]DVGHORV
TXHPDGRUHVHQODVSRVLFLRQHVFRUUHVSRQGLHQWHVHQOD
SODFDGHFRFFLyQ
CUANDO TODAS LAS
CONEXIONES SE HAYAN
COMPLETADO
$VHJ~UHVHGHTXHWRGRVORVFRQWUROHVTXHGHQHQOD
SRVLFLyQGHDSDJDGR$VHJ~UHVHGHTXHHOIOXMRGHOD
FRPEXVWLyQ\HODLUHGHODYHQWLODFLyQDODVXSHUILFLH
GHFRFFLyQHVWpQGHVREVWUXLGRV
SUPERFICIALES QUEMADORES
$ 5RVFDPDFKRGHWXEHUtD
137GH´
% &RGR
5
7DSD
4XHPDGRU
INSTALACIÓN EN ALTITUDES ELEVADAS
$PiVGHSLHVHOSURGXFWRFRQILJXUDGRSDUDJDVQDWXUDORSURSDQRUHTXLHUHODLQVWDODFLyQGHONLW
:%;SDUDJDVQDWXUDO\:%;SDUDJDVSURSDQR 6LJDODVLQVWUXFFLRQHVLQFOXLGDVFRQHONLW
4XHPDGRU
(OHFWURGR
(OHFWURGR
$QLOORP~OWLSOH
/DVUHMLOODV
(QDOJXQRVPRGHORV
/DVUHMLOODV
(QDOJXQRVPRGHORV
' &RQHFWRUIOH[LEOH SHUPLWHHOSDVR
DWUDYpVGHODSDUHGGHOJDELQHWH
( $GDSWDGRU
(
)
' &RQHFWRUIOH[LEOH
CONEXIONES ELÉCTRICAS
% Tapas -&RORTXHODVWDSDVHQORVTXHPDGRUHVGH
ORVWDPDxRVFRUUHVSRQGLHQWHV
CONEXIÓN DEL CONECTOR
$ 5RVFDPDFKRGHWXEHUtD
137GH´
3
G
)
+
G
,
) 5
HJXODGRUSURYLVWRFRQODXQLGDG
‡ 6DOLGD5RVFDKHPEUDGH
WXEHUtD137GH´
‡ (QWUDGD±5RVFDKHPEUDGH
WXEHUtD137GH´
* 7XEHUtDGHJDV
+ 9iOYXODGHFLHUUHPDQXDO
, 7XEHUtDGHJDVGH´R´
INSTRUCCIONES DE INSTALACIÓN
31-11089 07-17 GEA
JGP3030, JGP3530, JGP5030, PGP7030, PGP9030, CGP9530
JGP3036, JGP5036, PGP7036, PGP9036, CGP9536
Was this manual useful for you? yes no