Vent-A-Hood EPITH18448SS Installation Instructions

Add to my manuals
6 Pages

advertisement

Vent-A-Hood EPITH18448SS Installation Instructions | Manualzz
Read and Save These Instructions
All Hoods Must Be Installed By A Qualified Installer
INSTALLATION INSTRUCTIONS
EUROLINE/EUROLINE PRO
ISLAND RANGE HOOD
Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including firerated construction. Switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally
during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer’s guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and local code authorities.
E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to
a maximum of 15 CFM per 100 square feet of occupiable space, unless a
back drafting test is performed or make-up air is provided. Consult a local
HVAC engineer for make-up air evaluation.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK
C UL
L113 0611A
Page 1
R
US
Ducting Do’s and Don’ts
NEVER restrict the duct size. The island dual blower unit (T200) requires 8” round duct or
equivalent (50 square inches). The island cluster blower unit (T400) requires 12” round or
equivalent (113 square inches). Using the included Vent-A-Hood transition will ensure proper
efficiency.
Blower
Island Dual (T200)
Island Cluster Blower (T400)
Duct Size
8” round or equivalent
12” round or equivalent
Sq. Inch Area
50”
113”
Vent-A-Hood Transition
VP565 (Included)
VP564 (Included)
Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce
performance. Only use smooth, galvanized, metal duct. Observe local codes regarding special
duct requirements and placement of duct against combustibles. Make the duct run as short
and as straight as possible with as few turns as possible. Avoid sharp-angled turns. Instead,
use smooth, gradual turns such as adjustable elbows or 45 degree angled turns. For duct runs
over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree
elbow is equal to 5 feet of duct. Using Vent-A-Hood roof jacks or wall louvers (back page) will
ensure proper efficiency. Airflow must not be restricted at the end of the duct run. Do not use
screen wire or spring-loaded doors on wall louvers or roof jacks. Do not terminate venting into
an attic or chimney. Where possible, seal joints with duct tape. The hood must be ducted to the
outdoors without restrictions.
YES
Smooth Duct
Smooth Gradual Turn
NO
Sharp Angled Turns
Flexible Duct
L113 0611A
Page 2
Installation Details
1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only.
Custom hoods may require additional specification consideration.
2) When installing an island range hood, it is recommended that the bottom edge of the hood be located no more than
30” above the cooking surface. Exceeding recommended mounting height may compromise performance.
Shown with duct cover installed (sold separately).
3) Load-bearing framework in the ceiling is necessary for the installation of an island hood.
Additional framework construction may be required. Do not attach an island hood to a structure
that cannot support twice the weight of the hood.
If applicable, remove the duct cover from its packaging and remove the hood-mounting
screws from the base of the duct cover. Install the duct cover to the load-bearing framework
in the ceiling using appropriate hardware through the four inside corner mounting flanges
on the top of the duct cover.
1 ½”
�⁄��” Dia.
1 ½”
Island Duct Cover
Mounting Holes
(Top View)
4) Install the duct from the outside of the home down to the location of the exhaust outlet on the top of the transition plus
1”. This will allow the transition to engage 1” inside of the duct. Consult the connection diagrams (on next page) for
further details on exhaust outlet placement.
Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is listed on the back page
of this instruction sheet.
Transition heights are as follows:
Island Dual Blower (T200):
8” round duct connects to 9” tall VP565 transition (included).
Island Cluster Blower (T400):
12” round duct connects to 11 1/4” tall VP564 transition (included).
5) Prepare a protective surface on the floor or countertop for the hood. Remove the hood from its packaging and place
it upside-down on the protective surface for access to the inside of the hood.
L113 0611A
Page 3
Installation Details Continued
6) Remove the shipping tape that is securing the E-Z Clean shields inside the hood. Remove the E-Z Clean shields by
lightly pulling each toward the end of the hood. Gently close the back draft dampers from the top side of the hood. To
remove the blower housings, unsnap the suitcase latches (one on each side of the housing). The housings should be
pulled forward and gently “tipped” to clear the blower wheels and then out of the hood.
Connection Diagram (36”- 48” Widths)
Centerline
Of Hood
8" Round
8" Round
5" x 16"
Exhaust
Opening
Centerline
Of Hood
18"
9"
8" Transition
Opening
Vent Holes
Electrical
7 ¾"
5"
550 CFM T200 Dual Blower
(Top View)
16"
VP565 Standard Transition
(Included)
Transition Installed
(Side View)
Connection Diagram (48”- 66” Widths)
Centerline
of Hood
Electrical (2)
8” Blower
Outlets
12" Transition
Opening 2 ¼”
Above Top of
Hood
7 ¾”
2 ¼”
12" Round
12" Round
Vent Holes
Centerline
of Hood
11 ¼"
18”
10 ½”
8" Round
1100 CFM T400 Dual Blowers
(Top View)
8" Round
8" Round
VP564 Standard Transition
(Included)
Transition Installed
(Side View)
Warning: Make sure power is off and locked at the service disconnecting
means on the service panel during installation.
7) Remove the blower deck assembly by removing the 12 screws around the blower mounting plate. Unplug the electrical
connector(s) and set the blower assembly aside, taking care not to damage the blower wheels.
8) Install an appropriate 1/2” UL listed electrical wire clamp through the electrical strap(s) on top of the hood deck. Install
electrical wiring from the service panel to the hood location for each blower assembly. Consult the connection diagrams
(above) for further details on electrical placement. Support the hood beneath the location where it will hang and feed
the electrical wire(s) into the wire clamp(s). Tighten the wire clamp(s).
L113 0611A
Page 4
Installation Details Continued
Model
T200 Island Dual
T400 Island Cluster
Volts
Amps*
Hz
RPM
115
115
2.9
5.8
60
60
1550
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
1100
1800
998
855
774
Minimum Round
Duct Size
8" (50 in.2)
12" (13 in.2)
Sones#
6.0
6.4
* Add 0.5 amp for each halogen light.
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
#
Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
9) Raise the hood to its final position and attach it to the load-bearing framework in the ceiling using appropriate hardware
or to the duct cover using the screws previously removed in Step 3.
10) From inside the hood, using UL listed wire nuts, attach the “neutral” wire(s) to the white lead(s), the “hot” wire(s) to
the black lead(s), and the ground wire(s) to the green lead(s).
Warning: Do not operate hood without proper ground connection.
11) Attach the transition to the blower deck assembly and seal with duct tape. The transition must fit inside the exhaust
collar on the blower deck assembly. Reconnect the electrical connector(s). For assemblies with two connectors, connect
the right harness to the front connector and the left harness to the back connector. While taking care to properly align
the duct connection between the transition and the duct in the ceiling, reinstall the blower deck assembly into the
hood using the 12 screws previously removed in Step 7.
12) Replace the blower housings and the blower shields. Make sure that the dampers open and close smoothly.
13) Refer to Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light functions
to ensure they are operating properly.
L113 0611A
Page 5
VENTING
WALL LOUVER
WALL LOUVER
8 5⁄8”
WALL LOUVER
6”
7”
8”
RECTANGULAR WALL LOUVER
13”
11”
Back
View
ACCESSORIES
Back
View
11”
8 ½”
13”
1 ½” Flange
1 ½” Flange
10”
Back
View
3 ¼”
6”
E
ANG
2” FL
GE
1 ½” Flange
AN
” FL
1½
MODEL
VP526
VP527
VP528
MODEL
VP554
DESCRIPTION
6” Round
7” Round
8” Round
LOW PROFILE ROOF JACK
(MAXIMUM 4/12 PITCH)
16 ¾”
6 ½”
DESCRIPTION
10” Round
LOW PROFILE ROOF JACK
(MAXIMUM 4/12 PITCH)
MODEL
VP552
VP553
ADJUSTABLE ELBOW
MODEL
VP539-HP
VP540-HP
VP541-HP
10”
12”
MODEL
VP561
7”
10”
3 ¼”
MODEL
VP559
M1200 STANDARD TRANSITION
10”
10”
DESCRIPTION
3-1/4” x 10”
MODEL
VP521
STANDARD ISLAND TRANSITION
12”
11 ¼”
MODEL
VP566
16”
8”
DESCRIPTION
M1200 Transition
MODEL
VP565
SIDE VENT TRANSITION L & R
FOR ISLAND BLOWERS
5”
18 ½”
DESCRIPTION
5” x 16” to 8” Rnd
MODEL
VP564
16”
3 ¼”
7”
10 ½”
11”
MODEL
VP544
VP545
“Y” TRANSITION
DESCRIPTION
Side Left
Side Right
MODEL
VP529
ROUND DUCT PIPE
10”
11”
11”
6”
16”
6”
5”
DESCRIPTION
8” & 8” to 12”
OFFSET KIT - RECTANGULAR
OFFSET KIT - ROUND
19”
16”
DESCRIPTION
Top Left
Top Right
CLUSTER BLOWER TRANSITION
9”
9”
8”
MODEL
VP542
VP543
3 ¼”
DESCRIPTION
3-1/4” x 10 to 7”
8”
12”
5”
3 ¼” x 10” TO 7” TRANSITION
7 ½”
DESCRIPTION
8” to 6” x 8-1/2”
21”
8”
DESCRIPTION
10” Round
12” Round
3 ¼”
VP562 - 23 ¼”
VP563 - 30 ½”
OFFSET L & R TRANSITION
FOR ISLAND BLOWERS
MODEL
VP552-HP
VP553-HP
6”
VP562 - 17 ½”
VP563 - 16 ½”
DESCRIPTION
6” & 8” to 10”
8” & 8” to 12”
20 ¾”
DESCRIPTION
6” Round
7” Round
8” Round
4 ¼”
MULTI-BLOWER TRANSITION
10 ½”
22 ½”
14”
16”
MODEL
VP562
VP563
6 ½”
8 ½”
6”
7”
8”
DESCRIPTION
6” Round
7” Round
8” Round
LOW PROFILE ROOF JACK
(MINIMUM 4/12 PITCH)
3 ¼” x 10” BACK VENT ELBOW
BACK/SIDE VENT ELBOW
8” Round
MODEL
VP513
VP514
VP515
DESCRIPTION
6” x 8-1/2”
3-1/4” x 10”
16 ¾”
DESCRIPTION
10” Round
12” Round
12”
MODEL
VP538
VP560
16 ¾”
20 ¾”
DESCRIPTION
6” Round
7” Round
8” Round
VP513 - 8 ½”
VP514 - 9 9⁄16”
VP515 - 10 5⁄8”
DESCRIPTION
12” Round
LOW PROFILE ROOF JACK
(MINIMUM 4/12 PITCH)
10 ½”
22 ½”
16 ¾”
MODEL
VP539
VP540
VP541
MODEL
VP555
DESCRIPTION
6” Rnd to 7” Rnd
MODEL
VP550
3 ¼” RECTANGULAR DUCT PIPE
16”
DESCRIPTION
6” to 3-1/4” x 10”
6” RECTANGULAR DUCT PIPE
10”
12”
6”
7”
8”
18”
3 ¼”
30”
36”
MODEL
VP517
VP518
VP551
L113 0611A
DESCRIPTION
8” & 8” to 12”
6” & 8” to 12”
6” & 8” to 10”
MODEL
VP500
VP501
VP502
DESCRIPTION
6” Round
7” Round
8” Round
MODEL
VP504
VP505
VP506
Page 6
DESCRIPTION
3-1/4” x 10”
3-1/4” x 12”
3-1/4” x 16”
10”
12”
16”
6”
”
24”
MODEL
VP507
DESCRIPTION
6” x 8-1/2”
8½