Miele 52840705USA Installation Plan

Miele 52840705USA Installation Plan
Installation Plan
Tumble dryer
PT 8407 EL (Electrically Heated)
en - US
35.14
M.-Nr. 10 001 970
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
Fax:
609-419-4241
www.mieleusa.com
Technical Service & Support
Nationwide
Phone: 800-991-9380
Fax:
800-220-1348
[email protected]
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.
All rights reserved
2
35 5/8
3/4
35 3/8
25 5/8
55 1/8
20 1/2
3/4
25 1/4
55 1/8
24 3/4
41 7/8
45 7/8
41 3/4
23 3/8
1 1/2
3/4
2 5/8
63
PT 8407 EL - measurements in inches
3
35 5/8
35 3/8
<
45 7/8
41 3/4
63
PT 8407 EL - measurements in inches
6 3/8
6 1/4
5 7/8
2
4
11
52 7/8
63
24 3/8
7 7/8
12
5
63
12
5
5 7/8
PT 8407 EL - measurements in inches
5
55 1/8
2
3/4
3/4
55 1/8
2 1/8
31 1/8
15 1/2
42
47 1/4
42
41 3/4
63
63
15 1/2
2 1/8
21
2 1/8
21
31 1/8
2 1/8
35 3/8
35 3/8
2
3/8
PT 8407 EL - measurements in inches
2
2
2
2
3/8
6
PT 8407 EL - measurements in millimeters
7
<
PT 8407 EL - measurements in millimeters
8
PT 8407 EL - measurements in millimeters
9
PT 8407 EL - measurements in millimeters
10
Technical datasheet
PT 8407
Electric (EL)
Tumble dryer:
Heating:
Legend:
en - US
Abbreviations in bold type:
Connection required
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Optional extras:
BS
Concrete base
Quality and density of concrete must comply with load.
Concrete base must be firmly secured to floor!
4“
2“
35 3/8“
47 1/4“
100 mm
50 mm
900 mm
1200 mm
1. Standard voltage
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
3 AC 208V
60 Hz
67264 BTU/h
3 x 65 A
4 x AWG 6
19.7 kW
Connection cable to be ordered separately
2. Standard voltage
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
3 AC 220 - 240V
60 Hz
74776 - 83653 BTU/h
3 x 65 A
4 x AWG 6
21.9 - 24.5 kW
Recommended height
Minimum height
Width min.
Width min.
Machine connections:
Electrical
connection
(convertible)
4 x 16 mm²
4 x 16 mm²
Connection cable to be ordered separately
Electrical connection must comply with national
regulations.
Connection using multi-pole wall socket in compliance
with IEC/EN 60309 and IEC/EN 60947 is recommended
in order to simplify electrical tests.
If machines are hard-wired, a multi-pole mains switch
must be provided on site.
A wall socket or main isolator must be accessible after
installation.
Installation plan: PT 8407 EL
Date: 02.09.2014
Page: 11
Equipotential
bonding
Connection with male thread
with washers and nut.
3/8“ x 1 3/8“
10 mm × 35 mm
Max. nominal air flow in vented mode
Max. permissible pressure loss
28252 cu ft/h
0.04 psi
800 m³/h
300 Pa
Connection on machine side (ext. diameter)
Connection pipe provided on site (int. diameter)
Max. temperature
5 7/8”
5 7/8”
176 °F
150 mm
150 mm
80 °C
82.3 in²
531 cm²
6 3/8”
6 1/4”
161 mm
160 mm
1/4“ x 1 5/8“
3/8“ x 2“
6 mm × 40 mm
10 mm × 50 mm
1/4“ x 1 5/8“
3/8“ x 2“
6 mm × 40 mm
10 mm × 50 mm
Accessories not included.
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all
appropriate national and local regulations.
Vented
As relative humidity inside the vent duct can be as high
as 100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Air intake
Standard connection: Air intake from installation site
Unobstructed air intake into room recommended
(corresponding to 3 times the vent cross-section of
machine)
A sufficient supply of fresh air should be ensured to
replace the air extracted.
Alternative connection: Ducted air intake (from
outside building)
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
Lid removal exposes live components! For safety
reasons, the pipe connected for central air intake should
be at least 35 7/16” [900 mm] long and secured using
two screws.
Fittings
(supplied)
Without base
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
The machine should be bolted to the floor.
Fixing materials for floor screed are to be provided on
site.
On concrete platform
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for floor screed are to be provided on
site.
Machine data
Unit width
Machine depth
Unit height
Casing width
Casing depth
35 5/8“
45 7/8“
55 1/8“
35 3/8“
41 3/4“
906 mm
1164 mm
1400 mm
900 mm
1059 mm
Minimum width of delivery access to installation site
Recommended rear wall gap
(measured to front of machine)
Min. wall gap (to rear edge of lid)
36 1/4“
63“
920 mm
1600 mm
19 3/4“
500 mm
Net weight
Dynamic floor load, max.
Average heat dissipation
(dependent on ambient room temperature and
programme selected)
Noise level
Sound pressure level
(measured at a distance of 39 3/8” [1 m] from the
machine and at a height of 63” [1.6 m])
421.08 lbs
2170 N
2219.4 BTU/h
191 kg
650 W
72.8 dB (A)
60 dB (A)
Installation should only be carried out by authorized installers in accordance with all local and national regulations!
Follow installation instructions when installing machine. All rights reserved.
Installation plan: PT 8407 EL
Date: 02.09.2014
Page: 12