Miele 51413157NAM Installation Plan

Miele 51413157NAM Installation Plan
Installation Plan
Washing Machine
PW 413
PW 418
To prevent accidents and machine damage, read
these instructions before installation or use.
en-US
M.-Nr. 10 668 880
2
PW 413 / PW 418
Contents
Installation and planning notes .......................................................................................... 5
Installation requirements ....................................................................................................... 5
Storage/Transportation.......................................................................................................... 5
General operating conditions ................................................................................................ 5
Installation ............................................................................................................................. 6
Installation on concrete base ........................................................................................... 6
Leveling the machine............................................................................................................. 7
Securing the machine............................................................................................................ 7
Machine connections ............................................................................................................ 8
Electrical connection ............................................................................................................. 9
Water connection ................................................................................................................ 11
Cold water connection ................................................................................................... 11
Hot water connection ..................................................................................................... 11
Drain valve ...................................................................................................................... 11
Dispenser pump connections ............................................................................................. 13
Optional accessories........................................................................................................... 14
XKM RS232 communication module ............................................................................. 14
Base ............................................................................................................................... 14
Suds drain and vapor vent (BWS) .................................................................................. 14
Technical drawings - dimensions in inches ....................................................................
PW 413................................................................................................................................
Dimensions.....................................................................................................................
Dimensions with Miele base (UG/UO) ............................................................................
Installation ......................................................................................................................
PW 418................................................................................................................................
Dimensions.....................................................................................................................
Dimensions with Miele base (UG/UO) ............................................................................
Installation ......................................................................................................................
Anchoring PW 413/418 .......................................................................................................
Attaching to the floor/concrete base..............................................................................
Attaching to the floor/concrete base when installing in a run ........................................
Attaching to the floor with Miele base............................................................................
15
15
15
16
17
18
18
19
20
21
21
21
22
Technical drawings - dimensions in millimeters ............................................................
PW 413................................................................................................................................
Dimensions.....................................................................................................................
PW 413 with Miele base (UG/UO) ..................................................................................
Installation ......................................................................................................................
PW 418................................................................................................................................
Dimensions.....................................................................................................................
Dimensions with Miele base (UG/UO) ............................................................................
Installation ......................................................................................................................
Anchoring PW 413/418 .......................................................................................................
Attaching to the floor/concrete base..............................................................................
Attaching to the floor/concrete base when installing in a run ........................................
Attaching to the floor with Miele base............................................................................
23
23
23
24
25
26
26
27
28
29
29
29
30
Technical data....................................................................................................................
Water connection ................................................................................................................
Models with detergent dispenser drawer (WEK) ............................................................
Drain valve ......................................................................................................................
31
31
31
31
3
Contents
Connection for equipotential bonding.................................................................................
Anchoring ............................................................................................................................
Attaching to the floor......................................................................................................
Attaching to the floor with Miele base............................................................................
Attaching to a concrete base (provided on-site) ............................................................
PW 413................................................................................................................................
Electrical version and electrical data..............................................................................
Installation dimensions...................................................................................................
Transport data, weight and floor load ............................................................................
Emissions data ...............................................................................................................
PW 418................................................................................................................................
Electrical version and electrical data..............................................................................
Installation dimensions...................................................................................................
Transport data, weight and floor load ............................................................................
Emissions data ...............................................................................................................
4
31
31
31
31
31
32
32
32
33
33
34
34
34
35
35
Installation and planning notes
Installation requirements
The washing machine must be installed by Miele Service or by
properly trained staff of an authorized dealer.
 This washing machine must be installed in accordance with all relevant regulations and standards. Local energy supplier regulations
must also be observed.
 This washing machine must only be operated in a room that has
sufficient ventilation and which is frost-free.
The washing machine should not be installed or operated in any
area where there is a risk of explosion.
Storage/Transportation
The following conditions must be observed for transport and storage
of the machine:
– Ambient temperature: 32-105°F (0-40°C)
– Humidity: non-condensing
General operating conditions
This washing machine is intended only for use in an industrial environment and must only be operated indoors.
– Ambient temperature of location: 32-105°F (0-40°C)
– Relative humidity: non-condensing
– Maximum height above sea level of location site: 6500 ft (2000 m)
Depending on the nature of the installation site, sound emissions and
vibration may occur.
Tip: Have the installation site inspected and seek the advice of a professional in instances where increased noise may cause a nuisance.
PW 413 / PW 418
5
Installation and planning notes
Installation
This washing machine must be transported to its installation site using a suitable pallet jack. Remove the transport packaging.
The washing machine must be set up on a level and firm surface with
the minimum stated load bearing capacity (see "Technical data").
The floor load created by the washing machine is concentrated and
transferred to the installation footprint via the machine feet.
Tip: A concrete floor is the most suitable installation surface for this
machine, being far less prone to vibration during the spin cycle than
wooden floorboards or a carpeted surface.
The washing machine requires a gap of at least 2" (50 mm) on each
side to allow for movement during operation. To ensure suitable access for further maintenance and service work, please ensure a minimum distance of 16" (400 mm) is maintained between the back of the
machine and the wall.
Installation on
concrete base
The washing machine can be installed on a concrete base if desired.
The concrete materials and the durability of the concrete base must
be assessed in accordance with the floor load bearing capacity
given in "Technical data".
 To guarantee the stability of the washing machine, make sure that
the concrete base is sufficiently stable on the floor and that it is capable of withstanding any burden or force from the washing machine.
 The washing machine must be secured to the concrete base using
the fixtures and fastenings supplied.
 The washing machine must be secured to the base immediately
after installation!
There is a risk of the washing machine falling off a raised base during a spin cycle if it is not secured.
6
PW 413 / PW 418
Installation and planning notes
Leveling the machine
 Align the washing machine vertically and horizontally using the ad-
justable feet and a spirit level.
The washing machine must stand perfectly level on all four feet to
ensure safe and proper operation. Otherwise water and energy consumption will be increased and the machine could move.
 After aligning the machine tighten the lock nuts by turning them in a
counterclockwise direction with a wrench. This will prevent the feet
from moving.
Securing the machine
 The feet of the washing machine must be secured to the concrete
base using the fixtures and fastenings supplied.
Fittings supplied are for installation on a concrete floor. For other
types of flooring please purchase suitable fitting materials separately.
PW 413 / PW 418
7
Installation and planning notes
Machine connections
①
② ③ ④⑤ ⑥ ⑦
⑧
⑨
⑩
⑪
a Detergent dispenser (WEK)
b Communication module slot
The XKM RS232 communication module is available as an optional
accessory.
c Electrical connection
d Hard water connection (2x)
(Optional)
e Cold water connection
f Hot water connection
Water temperature to maximum 158°F (70°)
g Cold water connection
h Cold water connection for liquid dispensing
(Optional)
i Connections for external dispenser pumps
For up to 12 dispenser pumps
j Vapor extraction / free outlet Type AB
k Drain valve
Connection for plastic pipe NPS 2 ¾" (HT DN 70).
8
PW 413 / PW 418
Installation and planning notes
Electrical connection
The electrical connection must only be carried out by a qualified
electrician who must ensure that all electrical work is carried out in
accordance with applicable electrical regulations and standards.
 The washing machine must be connected to an electrical supply
that complies with local and national regulations. Please also observe
your insurance and energy supplier's regulations as well as any health
and safety at work regulations.
 The required voltage, power consumption and specifications for
external fusing are quoted on the data plate on the washing machine.
Ensure that the supply voltage complies with the voltage quoted on
the data plate before connecting the washing machine to the power
supply.
Connection to a supply voltage other than the one quoted on the
data plate can lead to functional faults and damage the washing
machine.
If more than one voltage is quoted on the data plate, the washing
machine can be converted for connection to the voltages stated.
 Conversion to a different voltage must only be carried out by a
Miele Service engineer or by an authorized Service Dealer. The wiring
instructions given on the wiring diagram must be followed.
The washing machine can either be hard-wired or connected via a
plug and socket that complies with national codes and regulations.
For a hard-wired connection an all-pole isolation device must be installed on site.
For hard-wired machines connection should be made via a suitable
switch with all-pole isolation which, when in the off position, ensures
a 1/8" (3 mm) gap between all open contacts. These include circuit
breakers, fuses and relays.
If the power supply cannot be permanently disconnected, the isolator
switch (including plug and socket) must be safeguarded against being switched on either unintentionally or without authorization.
Tip: We recommend connection to the power supply via a suitable
plug and socket which must be easily accessible for servicing and
maintenance work after the machine has been installed.
PW 413 / PW 418
9
Installation and planning notes
 If it is necessary to install a residual current device (RCD) in accordance with local regulations, a residual current device type B (sensitive to universal current) must be used.
An existing type A residual current device, (RCD) must be exchanged
for a type B RCD.
 If necessary, equipotential bonding with good galvanic contact
must be guaranteed in compliance with all applicable local and national installation specifications.
Equipotential bonding must have an earth current rating > 10 mA.
Accessories for equipotential bonding are not supplied and need to
be ordered separately.
10
PW 413 / PW 418
Installation and planning notes
Water connection
The washing machine complies with current local and national
safety regulations protecting the drinking water supply and can
therefore be connected to the drinking water supply without a nonreturn valve.
The machine is designed to operate with a supply pressure of between 14.5 psi (1 bar) and must not exceed 145 psi (10 bar). If it is
highter than 145 psi (10 bar) a pressure reducing valve must be used.
The machine must be connected to the water supply using the inlet
hoses provided.
 The connection points are subject to water supply pressure.
Turn on the faucet slowly and check for leaks.
Correct the position of the seal and union if necessary.
Cold water connection
A supply faucet with ¾" threaded union is required for each connection to the water supply (single or double). If this is not present, the
washing machine should be connected to the water supply by a qualified plumber.
The inlet hose for cold water (blue stripes) is not intended to be
used with a hot water supply line.
Hot water connection
To minimize energy consumption during operation with hot water,
the washing machine should be connected to a hot water ring circuit.
So-called "transmission lines" (single lines to hot water generators)
can result in cooling down of the water remaining in the pipes if not
in constant use. More energy would then be consumed to heat the
water up again.
Use the inlet hose supplied (red stripes) for the hot water connection.
The temperature of the water intake must not exceed 158°F (70°C).
If there is no hot water supply at the installation location for the washing machine, the connection hose must nevertheless be connected to
the cold water supply. A Y-piece is required in this case. The cold water consumption increases accordingly to account for the missing hot
water intake.
For functional and technical reasons it is not possible to operate
the machine exclusively with a hot water connection (without a
separate cold water intake).
Even if a hot water connection is present, the washing machine
must be connected to a cold water intake.
PW 413 / PW 418
11
Installation and planning notes
Drain valve
A motorized dump valve is used to drain the machine. A 2 ¾" angle
connector can be used for draining the machine directly into the
waste water system (without a siphon) or into an on-site gully (with
odor trap). The dump valve can also be operated manually to allow
the suds container to be emptied in the event of a power outage.
A vented drainage system is vital for unimpeded drainage.
If several machines are connected to a single drain pipe, it should
be large enough to allow all machines to drain simultaneously.
The appropriate Miele installation set M.-No.: 05 238 090 is available from Miele for venting a 2 ¾" (DN 70) pipe.
If the slope for drainage is extremely steep, the piping must be
vented so prevent formation of a vacuum in the machine's drain
system.
Slow or obstructed drainage or a backup of water in the drum as a result of undersized pipework can result in faults occurring during programs, which will result in error messages appearing in the display.
 Outflowing suds can be as hot as 203°F (95°C). Danger of injury
by burning!
Avoid direct contact.
12
PW 413 / PW 418
Installation and planning notes
Dispenser pump connections
Up to 12 dispenser pumps can be connected to the washing machine.
Dispenser pump connections on the back of the machine
Connections 1 and 2 are for viscous agents. These connectors are
sealed and need to be drilled out before connection with a
5/16" (8 mm) drill bit.
Make sure that you only drill through the first panel (I) as there is a
deflecting panel (II) 3/8" (10 mm) behind it.
Connections 3 to 12 are for liquid dispensing. These connections are
sealed and must be cut to the diameter of the hose with a small saw.
If opened connections are no longer required, they must be resealed
using a suitable sealant (e.g. silicone).
Connection terminals for five time-controlled dispenser pumps, which
can be operated without a multifunction module, are located behind
the cover adjacent to the electrical connection.
Calibration of the dispenser pumps and regulation of dispensing
quantities is carried out automatically for washing machines fitted
with a multifunction module.
A flowmeter or throughput sensors can be connected for precise
monitoring of the dispensing quantity.
Connections for level monitoring are available for every agent dispensed.
PW 413 / PW 418
13
Installation and planning notes
Optional accessories
Only use genuine Miele spare parts and accessories with this machine.
Using spare parts or accessories from other manufacturers will
void the warranty, and Miele cannot accept liability.
XKM RS232 communication module
The serial interface RS-232 can be retrofitted to the washing machine
via an XKM RS 232 (optional accessory available from Miele). This
communication module must only be used with Miele Professional machines that are fitted with an appropriate slot for the module.
The data interface provided via communication module
XKM RS232 complies with SELV (Safety Extra Low Voltage) in accordance with EN 60950.
Machines connected to this interface must also be SELV compliant.
Communication module XKM RS 232 is supplied with a connection
cable and a D-sub-connector.
Base
The machine can be installed on a machine base (open or box base,
available as an optional Miele accessory).
Elevating the washing machine gives a better ergonomic working
position when loading or unloading. It also simplifies the installation
of a waste water connection.
 When installed on a raised base, the machine must be secured
to the base and the base must be secured to the floor.
There is a risk of the washing machine falling off a raised base during a spin cycle if it is not secured.
Suds drain and
vapor vent (BWS)
14
If excessive suds form, suds may escape from the vapor vent. To
drain the suds, an optional vapor vent kit (BWS) can be installed.
PW 413 / PW 418
Technical drawings - dimensions in inches
PW 413
Dimensions
53.2"
21"
19.4"
35.4"
18.6"
3.5"
0.9"
20.9"
29.1"
53.2"
16.3"
35.4"
53.2"
31.5"
31.4"
39.8"
31.4"
31.5"
1"
Dimensions in inches
PW 413 / PW 418
15
Technical drawings - dimensions in inches
Dimensions with Miele base (UG/UO)
64.7"
3.5"
35.4"
30"
32.3"
40.5"
64.6"
21"
16.3"
19.4"
64.6"
35.4"
31.5"
31.4"
39.8"
31.4"
31.5"
1"
Dimensions in inches
16
PW 413 / PW 418
Technical drawings - dimensions in inches
33.3"
3.6"
5.9"
25.8"
30.2"
≥ 53.2"
≥ 53.2"
≥ 15.8"
≥ 15.8"
Installation
13.7"
27.4"
Dimensions in inches
PW 413 / PW 418
17
Technical drawings - dimensions in inches
PW 418
Dimensions
57.2"
21"
19.4"
33.8"
20"
2.6"
0.9"
22.3"
30.4"
57.1"
16.3"
33.8"
57.1"
36.4"
36.3"
37.4"
36.3"
36.4"
1"
Dimensions in inches
18
PW 413 / PW 418
Technical drawings - dimensions in inches
Dimensions with Miele base (UG/UO)
19.4"
67.3"
2.6"
33.8"
30"
32.3"
40.5"
67.2"
21"
16.3"
33.8"
67.2"
36.4"
36.3"
37.4"
36.3"
36.4"
1"
Dimensions in inches
PW 413 / PW 418
19
Technical drawings - dimensions in inches
38.2"
16.2"
32.4"
3.2"
5.9"
28.7"
20.2"
≥ 49.3"
≥ 49.3
≥ 15.8"
≥ 15.8"
Installation
Dimensions in inches
20
PW 413 / PW 418
Technical drawings - dimensions in inches
Anchoring PW 413/418
~ 3 1/2"
Attaching to the floor/concrete base
Ø 1/2"
Dimensions in inches
~ 3 1/2"
Attaching to the floor/concrete base when installing in a run
Ø 1/2"
Dimensions in inches
PW 413 / PW 418
21
Technical drawings - dimensions in inches
~ 3 1/2"
Attaching to the floor with Miele base
Ø 1/2"
Dimensions in inches
22
PW 413 / PW 418
Technical drawings - dimensions in millimeters
PW 413
Dimensions
1352
531
492
898
472
87
22
530
737
1350
415
897
1350
799
796
1010
795
799
25
Dimensions in millimeters
PW 413 / PW 418
23
Technical drawings - dimensions in millimeters
PW 413 with Miele base (UG/UO)
897
492
1640
1642
87
898
762
820
1027
1640
415
531
799
795
1010
795
799
25
Dimensions in millimeters
24
PW 413 / PW 418
Technical drawings - dimensions in millimeters
91
148
767
653
≥ 1350
≥ 1350
≥ 400
≥ 400
Installation
348
845
696
Dimensions in millimeters
PW 413 / PW 418
25
Technical drawings - dimensions in millimeters
PW 418
Dimensions
1452
531
492
858
507
66
22
564
772
1450
415
857
1450
924
920
950
920
924
25
Dimensions in millimeters
26
PW 413 / PW 418
Technical drawings - dimensions in millimeters
Dimensions with Miele base (UG/UO)
924
1705
1707
531
492
66
858
762
819
1027
1705
415
857
920
950
920
924
25
Dimensions in millimeters
PW 413 / PW 418
27
Technical drawings - dimensions in millimeters
148
727
513
≥ 1250
≥ 1250
≥ 400
≥ 400
Installation
411
82
970
821
Dimensions in millimeters
28
PW 413 / PW 418
Technical drawings - dimensions in millimeters
Anchoring PW 413/418
~ 90
Attaching to the floor/concrete base
Ø 12
Dimensions in millimeters
~ 90
Attaching to the floor/concrete base when installing in a run
Ø 12
Dimensions in millimeters
PW 413 / PW 418
29
Technical drawings - dimensions in millimeters
~ 90
Attaching to the floor with Miele base
Ø 12
Dimensions in millimeters
30
PW 413 / PW 418
Technical data
Water connection
Models with detergent dispenser drawer (WEK)
Permitted supply pressure
14.5-145 psi (1-10 bar)
Maximum water intake rate
21 gal/min (79.5 l/min)
Cold water connection
(to be provided on site, external thread according to DIN 44991, flat seal)
2 x ¾"
Optional cold-hard water connection
(to be provided on site, external thread according to DIN 44991, flat seal)
2 x ¾"
Hot water connection ≤ 158°F (70°C)
(to be provided on site, external thread according to DIN 44991, flat seal)
1 x ¾" (25 x 19 mm)
Water intake hose length
59" (1500 mm)
Drain valve
Maximum drain water temperature
Waste water connection (on machine)
Drain (on-site)
Maximum drainage rate
203°F (95°C)
NPS 2 ¾" (DN 70) plastic pipe
2 ¾" connection
53 gal/min (200 l/min)
Connection for equipotential bonding
Connection with male thread (machine)
Washers and nuts
3/8" x 1 3/8" (10 x 35 mm)
M 10
Anchoring
Attaching to the floor
Required anchor points
2
Wood screw (diameter x length)
1/2" x 3 1/2" (12 mm x 90 mm)
Wall anchors (diameter x length)
5/8" x 3 1/8" (16 mm x 80 mm)
Attaching to the floor with Miele base
Required anchor points
4
Wood screw (diameter x length)
1/2" x 3 1/2" (12 mm x 90 mm)
Wall anchors (diameter x length)
5/8" x 3 1/8" (16 mm x 80 mm)
Attaching to a concrete base (provided on-site)
Required anchor points
2
Wood screw (diameter x length)
1/2" x 3 1/2" (12 mm x 90 mm)
Wall anchors (diameter x length)
5/8" x 3 1/8" (16 mm x 80 mm)
PW 413 / PW 418
31
Technical data
PW 413
Electrical version and electrical data
3 AC 200-208/220-240 V, 60 Hz, electrically heated
Standard:
Connection voltage
3 AC 220-240 V
Frequency
60 Hz
Fuse rating
3 x 25 A
Power rating
Power cord, min. cross-section
Cord connector
10.2-11.8 kW
4 x AWG 12
M 32
Convertible to:
Connection voltage
3 AC 200-208 V
Frequency
60 Hz
Fuse rating
3 x 25 A
Power rating
Power cord, min. cross-section
Cord connector
8.8-9.4 kW
4 x AWG 12
M 32
3 AC 220-240 V, 60 Hz, without heating
Standard:
Connection voltage
3 AC 220-240 V
Frequency
60 Hz
Fuse rating
3 x 16 A
Power rating
Power cord, min. cross-section
Cord connector
2.3 kW
4 x AWG 14
M 25
Convertible to:
Connection voltage
3 AC 200-208 V
Frequency
60 Hz
Fuse rating
3 x 16 A
Power rating
Power cord, min. cross-section
Cord connector
2 kW
4 x AWG 14
M 25
Installation dimensions
Casing width (without add-on components)
31.4" (795 mm)
Casing height (without add-on components)
53.2" (1350 mm)
Casing depth (without add-on components)
35.4" (897 mm)
Overall machine width
31.5" (799 mm)
Overall machine height
53.3" (1352 mm)
Overall machine depth
39.8" (1010 mm)
Minimum width of transport opening
Minimum distance between wall and machine front
32
31.7" (805 mm)
53.2" (1350 mm)
PW 413 / PW 418
Technical data
Transport data, weight and floor load
PW 413 with detergent dispenser drawer (WEK), electrically heated
Packaging width
44.5" (1130 mm)
Packaging height
57.8" (1468 mm)
Packaging depth
43" (1090 mm)
Gross volume
63.9 cu. ft. (1808 l)
Gross weight
717 lb (325 kg)
Net weight
655 lb (297 kg)
Maximum floor load during operation
4608 N
PW 413 with detergent dispenser drawer (WEK), without heating
Packaging width
44.5" (1130 mm)
Packaging height
57.8" (1468 mm)
Packaging depth
43" (1090 mm)
Gross volume
63.9 cu. ft. (1808 l)
Gross weight
712 lb (323 kg)
Net weight
650 lb (295 kg)
Maximum floor load during operation
4589 N
Emissions data
Workplace related sound pressure level, washing
Sound power level, washing
Workplace related sound pressure level, spinning
Sound power level, spinning
Average heat dissipation rate to installation site
PW 413 / PW 418
53 dB (A)
62.0 dB (A)
67 dB (A)
74.2 dB (A)
Electrically heated models: 3754 BTU
Models without heating: 683 BTU
33
Technical data
PW 418
Electrical version and electrical data
3 AC 200-208/220-240 V, 60 Hz, electrically heated
Standard:
Connection voltage
3 AC 220-240 V
Frequency
60 Hz
Fuse rating
3 x 40 A
Power rating
Power cord, min. cross-section
Cord connector
11.9-13.6 kW
4 x AWG 8
M 40
Convertible to:
Connection voltage
3 AC 200-208 V
Frequency
60 Hz
Fuse rating
3 x 40 A
Power rating
Power cord, min. cross-section
Cord connector
10.4-11.0 kW
4 x AWG 8
M 40
3 AC 220-240 V, 60 Hz, without heating
Standard:
Connection voltage
3 AC 220-240 V
Frequency
60 Hz
Fuse rating
3 x 16 A
Power rating
Power cord, min. cross-section
Cord connector
3 kW
4 x AWG 12
M 25
Convertible to:
Connection voltage
3 AC 200-208 V
Frequency
60 Hz
Fuse rating
3 x 16 A
Power rating
Power cord, min. cross-section
Cord connector
3 kW
4 x AWG 12
M 25
Installation dimensions
Casing width (without add-on components)
36.3" (920 mm)
Casing height (without add-on components)
57.1" (1450 mm)
Casing depth (without add-on components)
33.8" (857 mm)
Overall machine width
36.4" (924 mm)
Overall machine height
57.2" (1452 mm)
Overall machine depth
37.4" (950 mm)
Minimum width of transport opening
Minimum distance between wall and machine front
34
36.7" (930 mm)
49.3" (1250 mm)
PW 413 / PW 418
Technical data
Transport data, weight and floor load
PW 418 with detergent dispenser drawer (WEK), electrically heated
Packaging width
46.9" (1190 mm)
Packaging height
61.8" (1568 mm)
Packaging depth
44.5" (1130 mm)
Gross volume
74.5 cu. ft. (1931 l)
Gross weight
994 lb (451 kg)
Net weight
935 lb (424 kg)
Maximum floor load during operation
6027 N
PW 418 with detergent dispenser drawer (WEK), without heating
Packaging width
46.9" (1190 mm)
Packaging height
61.8" (1568 mm)
Packaging depth
44.5" (1130 mm)
Gross volume
74.5 cu. ft. (1931 l)
Gross weight
990 lb (449 kg)
Net weight
930 lb (422 kg)
Maximum floor load during operation
6007 N
Emissions data
Workplace related sound pressure level, washing
Sound power level, washing
Workplace related sound pressure level, spinning
Sound power level, spinning
Average heat dissipation rate to installation site
PW 413 / PW 418
54 dB (A)
62.0 dB (A)
65 dB (A)
77.3 dB (A)
Electrically heated models: 6142 BTU
Models without heating: 1024 BTU
35
Please have the model and serial number
of your machine available when
contacting Technical Service.
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
Fax: 609-419-4241
www.miele-pro.com
[email protected]
Technical Service & Support
Phone: 800-991-9380
Fax:
800-220-1348
[email protected]
Alteration rights reserved / Publication date: 2117
PW 413
PW 418
M.-Nr. 10 668 880 / 01
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement