Installation plan
Washer
PW 6207 EL
en - US
11.11
M.-Nr. 09 284 490 / 01
M.-Nr. 09 284 490 / 01
2
Technical Data Sheet
Washer:
Type of heating:
PW 6207
Electric (EL)
Legend:
Circled, bold-type abbreviations mean:
Connection required
en - US
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Options/Accessories:
UM
Miele base
UO 6020 (UO = open base)
Height
Width
Depth
9 7/16“
36 1/4“
39 3/4“
240 mm
920 mm
1,009 mm
UG 6020 (UG = closed-in base)
Height
Width
Depth
9 7/16“
36 1/4“
40 1/8“
240 mm
920 mm
1,019 mm
9 7/16“
3 15/16“
36 1/4“
41 5/16“
240 mm
100 mm
920 mm
1,050 mm
1. Standard voltage (as delivered) *
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Connection cable not included.
3 AC 220-240 V
50 – 60 Hz
18 kW
3 x 50 A
4 x 10 mm²
3 AC 220-240 V
50 – 60 Hz
18 kW
3 x 50 A
4 x 10 mm²
Alternative voltage (switchable)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Connection cable not included.
3 AC 208 V
60 Hz
15,3 kW
3 x 50 A
4 x 10 mm²
3 AC 208 V
60 Hz
15,3 kW
3 x 50 A
4 x 10 mm²
BS
Concrete platform Recommended height
Minimum height
Min. platform width
Min. platform depth
WI
Weighing system
OS
Offshore
Version with built-in weighing system
Special version Offshore
Machine connections:
* If power supply includes a stinger leg, please contact Technical Service at
USA 1-800-991-9380
CDN 1-800-643-5361
Technisches Datenblatt / Technical datasheet: PW 6207 EL
Datum / Date: 12-01-2011
Seite / Page:
7
The electrical connection may only be made to an electrical
system listed in accordance with the national laws, ordinances and directives as well as the local provisions. In
addition to this, the regulations of the power supply utility,
the accident prevention regulations and the insurance company applicable at the site of installation as well as the
recognized standards of technology must also be observed.
The installation must be performed by a qualified person
(electrician).
The appliance can be connected either via permanent
connections or via plug connections according to IEC
60309-1. Wall receptacles or mains separation devices
must be accessible after the appliance is installed.
However, we recommend connecting the appliance via a
plug connection so that an electrical safety check can be
carried out, e.g. during repair or maintenance.
If it is necessary to install a residual current device (RCD) in
accordance with the local regulations, a residual current
device type B (AC/DC-sensitive) must always be used.
Potential
equalization
Externally threaded supports
for shims and nuts
3/8” x 1 3/8”
10 M
10 × 35 mm
10 M
AC 230 V
5 × 1.5 mm²
AC 230 V
5 × 1,5 mm²
Water pressure/Min. flow rate
Water pressure/Max. flow rate
Max. volume flow
Max. volume flow (in absence of hot and hard water supply)
14.5 psi
145.04 psi
5.7 gal/min
9.2 gal/min
100 kPa
1.000 kPa
26 l/min
42 l/min
2 Connector hoses with threaded joint ¾“ including Y fitting
(¾“ / 1“) included with the unit.
Threaded connector fitting at site as per DIN 44 991 (flat
sealing)
Length of connector hose
1“ external
thread
4‟ 11 1/16”
1“ external
thread
1,500 mm
30.6 gal/h
approx. 116 l/h
Max. water temperature
Water pressure/Min. flow rate
Water pressure/Max. flow rate
Max. volume flow
158°F
14.5 psi
145.04 psi
4.2 gal/min
70 °C
100 kPa
1.000 kPa
16 l/min
1 Connector hose with threaded joint ¾“ included with the
unit.
Threaded connector fitting at site as per DIN 44 991 (flat
sealing)
Length of connector hose
¾" external
thread
4‟ 11 1/16”
¾" external
thread
1,500 mm
31.4 gal/h
approx. 119 l/h
Accessories such as shims and nuts are only included with
the OS version.
If necessary, equipotential bonding with good galvanic
contact must be created, in compliance with all applicable
local installation specifications.
Peak load switch- Connected voltage for the control contacts
off
Connection cable, min. cross-section
Connection cable not included.
We recommend making the connection with a flexible connection line and an additional separator. When installed, the
separator should be visible and directly accessible.
Cold water
Soft water
Average water requirement for a standard program (60°
colored washing) determined at cold, hot and hard water
connection.
If no hot water, add the corresponding water requirement to
the cold water requirement.
If connecting to industrial water (option), subtract that water
requirement from the cold water requirement.
Hot water Soft
water
Average water requirement for a standard program (60°
colored washing) determined at cold, hot and hard water
connection.
If no hot water supply, connect hose to cold water!
Technisches Datenblatt / Technical datasheet: PW 6207 EL
Datum / Date: 12-01-2011
Seite / Page:
8
Cold water
Hard water
Water pressure/Min. flow rate
Water pressure/Max. flow rate
Max. volume flow
14.5 psi
145.04 psi
7 gal/min
100 kPa
1,000 kPa
32 l/min
2 Connector hoses with threaded joint ¾“ including Y fitting
(¾“ / 1“) optionally included with the unit.
Threaded connector fitting at site as per DIN 44 991 (flat
sealing)
Length of connector hose
1“ external
thread
4„ 11 1/16“
1“ external
thread
1,500 mm
19 gal/h
approx. 72 l/h
14.5 psi
145.04 psi
1.45 gal/min
100 kPa
1,000 kPa
5.5 l/min
¾" external
thread
4‟ 11 1/16”
¾" external
thread
1.500
203°F
2 15/16“
[DN 2 3/4“]
2 15/16“ [DN
2 3/4“ sleeve]
43.99 gal/min
95 °C
75 mm [DN 70]
1/2” x 3 9/16”
5/8” x 3 1/8”
12 x 90 mm
16 x 80 mm
1/2” x 3 9/16”
5/8” x 3 1/8”
12 x 90 mm
16 x 80 mm
5/16“ x 3 1/8“
1/2“ x 2 3/8“
8 x 80 mm
12 x 60 mm
Average water requirement for a standard program (60°
colored washing) determined at cold, hot and hard water
connection.
Cold water
Water pressure/Min. flow rate
Liquid dispensing Water pressure/Max. flow rate
Max. volume flow
1 Connector hose with threaded joint ¾“ optionally included
with the unit.
Threaded connector fitting at site as per DIN 44 991 (flat
sealing)
Length of connector hose
Drainage
Dump valve
Max. water outflow temperature
Drainage supports in machine (outer diameter)
On-site drain connection (inner diameter)
Max. transient throughput
75 mm [DN 70
sleeve]
200 l/min
Vented drainage required. If ventilation is insufficient, fit
Miele kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of sufficient cross-section.
Fittings
without plinth
It is essential to ensure that the appliance is fastened adequately to the substrate!
Fastening material included with unit:
2 × wood screws DIN 571 (Ø × length)
2 × screw anchors (Ø × length)
A sufficiently firm substrate with sufficient load-bearing
capacity is necessary for the installation. The fastening
material included is only suitable for a solid concrete substrate. The fastening material for other suitable substrates
must be provided on site.
on concrete platform
It is essential to ensure that the appliance is fastened adequately to the substrate!
Fastening material included with unit:
2 × wood screws DIN 571 (Ø × length)
2 × screw anchors (Ø × length)
The quality of the concrete and its strength must be assessed according to the machine load. Ensure that the
location of the platform is fixed adequately in the case of
dynamic loads!
Miele base
It is essential to ensure that the base is fastened adequately
to the substrate!
Fastening material included with base:
4 × wood screws DIN 571 (Ø × length)
4 × screw anchors (Ø × length)
The installation and assembly of the appliance and base
must follow the installation instructions provided
Technisches Datenblatt / Technical datasheet: PW 6207 EL
Datum / Date: 12-01-2011
Seite / Page:
9
Version
WI
It is essential to ensure that the appliance is fastened adequately to the substrate!
Fastening material included with unit:
4 × wood screws DIN 571 (Ø × length)
4 × screw anchors (Ø × length)
1/2” x 3 9/16”
5/8” x 3 1/8”
12 x 90
16 x 80
1/2“
12 mm
Width
Depth
Height
Housing width
Housing depth
36 3/8“
44 1/2“
55 1/8“
36 1/4“
40 3/16“
924 mm
1,130 mm
1,400 mm
920 mm
1,020 mm
Width loading opening (clear width)
Recommended wall spacing (to front edge of appliance
front)
Minimum wall spacing (to rear edge of appliance cover)
36 5/8“
57 1/16“
930 mm
1,450 mm
15 3/4“
400 mm
Net weight
Max. floor loading in operation.
Max static loading
Max dynamic loading
Max. drum rotation frequency
Average heat dissipation in the installation room
(depending on room temperature and selected program)
1120 lbs
6,203 N
5,670 N
533 N
18.3 Hz
1,520 W
508 kg
6.203 N
5,670 N
533 N
18.3 Hz
1,520 W
Noise level (re 20 mPA),
relative to the workplace (distance 1 m and 1.6 m high)
70 dB (A)
70 dB (A)
A sufficiently firm substrate with sufficient load-bearing
capacity is necessary for the installation. The fastening
material included is only suitable for a solid concrete substrate. The fastening material for other suitable substrates
must be provided on site.
Version
OS
It is essential to ensure that the appliance is fastened adequately to the substrate!
The fastening material is not included with the unit
Female thread for the fastening
The fastening must be carried out on site corresponding to
the local requirements and conditions. The appliance is
supplied without feet so that the female thread can be used
for fastening with studs.
Machine data
Installation should only be carried out by authorized installers and must comply with local and national building codes.
Observe installation instructions when installing this machine. Alteration rights reserved.
Technisches Datenblatt / Technical datasheet: PW 6207 EL
Datum / Date: 12-01-2011
Seite / Page:
10