Miele 51620745USA Operating Instructions Steam Heated

Miele 51620745USA Operating Instructions Steam Heated
Installation plan
Washer
PW 6207 D (Steam Heated)
Always read operating and installation instructions before
Installation and Commissioning.
This is for the protection of yourself and your machine.
en - US
10 002 290 / 01
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.
All rights reserved!
2
10 002 290 / 01
Machine dimensions
10 002 290 / 01
( m e a s u r e me n t s i n mi l l i me t e r s )
3
Connections
4
( m e a s u r e me n t s i n mi l l i me t e r s )
10 002 290 / 01
Machine dimensions
10 002 290 / 01
( m e a s u r e me n t s i n m i l l i m e t e r s )
5
Machine dimensions
6
( m e a s u r e me n t s i n mi l l i me t e r s )
10 002 290 / 01
Machine dimensions
10 002 290 / 01
( m e a s u r e me n t s i n i n c h e s )
7
Connections
8
( m e a s u r e me n t s i n i n c h e s )
10 002 290 / 01
Machine dimensions
10 002 290 / 01
( m e a s u r e me n t s i n i n c h e s )
9
Machine dimensions
10
( m e a s u r e me n t s i n i n c h e s )
10 002 290 / 01
Technical datasheet
Washer-extractor:
Heating:
Legend:
PW 6207
Steam
Abbreviations in bold type:
Connection required
Abbreviations in circle with dashes:
Connection optional or required depending on model version
UM
BS
DAV
Miele base
UO 6020 (UO = open base)
Height
Width
Depth
UG 6020 (UG = closed-in base)
Height
Width
Depth
Concrete base Quality and density of concrete must comply with load.
Concrete base must be firmly secured to floor!
Recommended height
Minimum height
Minimum width
Minimum depth
The steam valve regulating the steam flow must be provided
Steam
connection valve on-site.
Pneumatic Steam Valve (PND)
Adjustable steam pressure
Connection size
9 7/16"
35 7/16"
39 3/4"
240 mm
900 mm
1009 mm
9 7/16"
36 1/4"
40 1/8"
240 mm
920 mm
1019 mm
9 7/16"
3 15/16"
36 1/4"
41 5/16"
240 mm
100 mm
920 mm
1050 mm
0 - 145 psi
1/2"
0 - 1000 kPa
The connection and the pneumatic valve controller must be
provided on-site.
Technical datasheet: PW 6207 D
10 002 290 / 01
11
EL
Electrical
connection
Standard voltage
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
3 AC 208 V
50 - 60 Hz
3.0 kW
3 x 15 A
4 x AWG 16
4 × 1.5 mm²
Convertible to
Frequency
Rated load
Fuse Rating
Connection cable, min. cross-section
3 AC 220 - 240 V
50 - 60 Hz
4.3 kW
3 x 15 A
4 x AWG 16
4 x 1.5 mm²
Connection cable not included.
The electrical connection may only be made to an electrical system listed in accordance with the national laws,
ordinances and directives as well as the local provisions.
In addition to this, the regulations of the power supply utility, the accident prevention regulations and the insurance
company applicable at the site of installation as well as the recognized standards of technology must also be
observed.
The installation must be performed by a qualified person (electrician).
The appliance can be connected either via permanent connections or via plug connections according to IEC
60309-1. Wall receptacles or main separation devices must be accessible after the appliance is installed.
However, we recommend connecting the appliance via a plug connection so that an electrical safety check can be
carried out, e.g. during repair or maintenance.
If it is necessary to install a residual current device (RCD) in accordance with the local regulations, a residual
current device type B (AC/DC-sensitive) must always be used.
PA
D
K
Potential
equalization
Steam
connection
(indirect steam)
Externally threaded supports
for shrims and nuts
If necessary, equipotential bonding with good galvanic
contact must be created, in compliance with all
applicable local installation specifications.
Steam pressure
Boiling point
Steam supply capacity
Heat output
Connection thread (on-site)
Steam valve, steam filter, steam faucet must be
provided on-site.
Follow installation instructions for steam-heated Miele washer-extractors.
Connection thread (on-site)
Condensate
connection
3/8" x 1 3/8"
10 M
10 x 35 mm
87 - 145.04 psi
305.6 - 363.2 °F
127.9 lbs/h
109260 BTU/h
1/2"
internal thread
600 - 1000 kPa
152 - 184 °C
58 kg/h
32 kW
1/2"
internal thread
Steam valve, steam filter and steam faucet must be
provided on-site.
Installation of the steam trap needs to allow complete
drainage of the heater element during machine
downtime. This means, no condensate is left in the
heater element.
Installation of an inverted bucket steam trap is
recommended.
Technical datasheet PW 6207 D
12
10 002 290 / 01
KW
Cold water
(Soft water)
Water pressure/Min. flow rate
Water pressure/Max. flow rate
Max. volume flow
Max. volume flow in absence of hot and hard water
supply
14.5 psi
145 psi
6.87 gal/min
11.1 gal/min
100 kPa
1000 kPa
26 l/min
42 l/min
2 Connector hoses with threaded joint 3/4” including
Y fitting (3/4” / 1”) included with the unit.
Threaded connector fitting at site as per DIN 44 991 1" external thread
(flat sealing)
Length of connection hose
59 1/16"
Average water requirement for a standard program
(60°C colored washing) determined at cold, hot and
hard water connection.
WW
KWH
KWF
Hot water
(Soft water)
Cold water
(Hard water)
Cold Water
(Liquid
dispensing)
AV
Drainage
Dump valve
B
Fittings
Add the hot water water requirement to the cold
water requirement, if there is no hot water supply
available.
If connecting to industrial water supply (optional),
subtract that water requirement from the cold water
requirement.
Max. temperature
Min. flow pressure
Max. pressure
Max. throughput
On-site connection thread according to DIN 44 991
Length of connection hose
(supplied) 1 connection hose)
Water requirements (average for 60°C
programme)
Machine can be connected to a hot water supply
line with a temperature of 70°C to max. 85°C. This
requires a separate inlet hose. This additional inlet
hose is available from Miele Spares. The machine
must also be reprogrammed by Miele Service or an
authorised agent.
If hot water is not available, connect hot water hose
to cold water valve!
Water pressure/Min. flow rate
Water pressure/Max. flow rate
Max. volume flow
Threaded connector fitting at site as per DIN 44 991
(flat sealing)
Length of connector hose
Avarage water requirement for a standard program
(60° colored washing) determined at cold, hot and
hard water connection
Water pressure/Min. flow rate
Water pressure/Max. flow rate
Max. volume flow
1 Connector hose with threaded joint 3/4” optionally
included with the unit.
Threaded connector fitting at site as per DIN 44991
(flat sealing)
Length of connector hose
Max. water outflow temperature
Drainage supports in machine (outer diameter)
On-site drain connection (inner diameter)
Max. transient throughput
Vented drainage required. If ventilation is
insufficient, fit Miele kit, Mat. no. 05238090.
Drain manifolds serving several machines must be
of sufficient cross-section.
Without base
It is essential to ensure that the appliance is
fastened adequately to the floor!
Fastening material included with unit:
2 x mounting brackets (from transport lock)
2 x wood screws DIN 571 (Ø x length)
2 x screw anchors (Ø x length)
1500 mm
approx. 32.8 gal/h
approx. 124 l/h
158°F
14.5 psi
145.04 psi
4.22 gal/min
3/4" external thread
59 1/16"
70°C
100 kPa
1000 kPa
16 l/min
approx. 28.5 gal /h
approx. 108 l/h
14.5 psi
145.04 psi
8.45 gal/min
1" external thread
100 kPa
1000 kPa
32 l/min
59 1/16"
approx. 19.5 gal/h
1500 mm
approx. 74 l/h
14.5 psi
145.04 psi
1.45 gal/min
100 kPa
1000 kPa
5.5 l/min
1500 mm
3/4" external thread
59 1/16"
203 °F
2 15/16"
2 15/16"
52.8 gal/min
1500 mm
95°C
75 mm [DN 70]
75 mm [DN 70]
200 l/min
5/16" x 3 1/8"
1/2" x 2 3/8"
8 mm x 80 mm
12 mm x 60 mm
A sufficiently firm floor with sufficient load-bearing
capacity is necessary for the installation. The
fastening material included is only suitable for a
solid concrete floor. The fastening material for other
suitable floor types must be provided on site.
Technical datasheet: PW 6207 D
10 002 290 / 01
13
On concrete platform
It is essential to ensure that the appliance is fastened
adequately to the concrete base!
Fastening material included with unit:
2 x mounting brackets (from transport lock)
2 x wood screws DIN 571 (Ø x length)
5/16" x 3 1/8"
2 x screw anchors (Ø x length)
1/2" x 2 3/8"
The quality of the concrete and its strength must be
assessed according to the machine load. Ensure that
the location of the platform is fixed adequately in case
of dynamic loads!
8 mm x 80 mm
12 mm x 60 mm
Miele base
It is essential to ensure that the appliance is fastened
adequately to the floor!
Fastening material included with base:
4 x wood screws DIN 571 (Ø x length)
4 x screw anchors (Ø x length)
5/16" x 3 1/8"
1/2" x 2 3/8"
8 mm x 80 mm
12 mm x 60 mm
Width
Depth
Height
Housing width
Housing depth
36 3/8"
44 1/2"
55 1/8"
36 1/4"
40 3/16"
924 mm
1130 mm
1400 mm
920 mm
1020mm
Width loading opening (clear width)
Recommended wall spacing (to rear edge of
appliance front)
Minimum wall spacing (to rear edge of appliance
cover)
36 5/8"
57 1/16"
930 mm
1450 mm
15 3/4"
400 mm
The installation and assembly of the appliance and
base must follow the installation instructions provided.
Machine data
Net weight
1119.9 lbs
508 kg
Max. floor loading in operation
6076 N
Average heat dissipation in the installation room
5216.5 BTU/h
5.5 MJ/h
(depending on room temperature and selected
program)
Installation should only be carried out by authorized installers in accordance with all local and national regulations! Follow
installation instructions when installing machine! All rights reserved!
Technical datasheet PW 6207 D
14
10 002 290 / 01
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement