Miele | 52830366USA | Installation Plan | Miele 52830366USA Installation Plan

Miele 52830366USA Installation Plan
Installation Plan
Tumble dryer
PT 8303 SL EL (Electrically Heated)
en – US
16.15
M.-Nr. 10 007 270 / 02
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
609-419-4241
Fax:
www.mieleusa.com
Technical Service & Support
Nationwide
Phone: 800-991-9380
Fax:
800-220-1348
proservice@mieleusa.com
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.
All rights reserved
2
28
3/4
3/4
31 7/8
70 7/8
20 1/2
27 7/8
39 1/2
70 7/8
24 3/4
25 5/8
42 7/8
2 1/2
1
3/4
29 3/4
39 3/8
59
PT 8303 SL EL - measurements in inches
3
28
27 7/8
42 7/8
39 3/8
59
PT 8303 SL EL - measurements in inches
6 3/8
6 1/4
5 7/8
2
4
3 1/2
66 7/8
24 3/8
9 1/4
12 1/4
13 3/8
10 1/8
66 7/8
10 1/8
5 1/4
PT 8303 SL EL - measurements in inches
5
3/4
5 1/8
70 7/8
25 1/4
39 3/8
39 7/8
59
12 5/8
1 3/8
19 1/8
1 3/8
2
2
27 7/8
3/8
PT 8303 SL EL - measurements in inches
6
PT 8303 SL EL - measurements in millimeters
5
PT 8303 SL EL - measurements in millimeters
6
PT 8303 SL EL - measurements in millimeters
7
PT 8303 SL EL - measurements in millimeters
8
Technical datasheet
Tumble dryer:
Heating:
PT 8303 SL
Electric (EL)
Legend:
Abbreviations in bold type:
Connection required
en - US
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Machine connections:
Electrical
connection
Standard voltage
Frequency
Rated load
Fuse rating
Supply lead cross-section
Convertible to
Frequency
Rated load
Fuse rating
Supply lead cross-section
Convertible to
Frequency
Rated load
Fuse rating
Supply lead cross-section
3 AC 220 - 240 V
60 Hz
15.4 kW
3 x 40 A
4 x 6 mm²
3 AC 208 V
60 Hz
11.7 kW
3 x 35 A
4 x 6 mm²
2 AC 208 V
60 Hz
8.1 kW
2 x 40 A
3 x 6 mm²
4 × 10 AWG
4 x 10 AWG
3 x 10 AWG
Electrical connection must comply with national regulations.
A wall socket or main isolator must be easily accessible after
installation.
Reinstallation of the supply point, changes to the equipment
or checks on the protective conductor, including determination
of correct fuse rating, should only be performed by a trained
electrician.
Vented
Nominal air throughput in vented mode
Max. permissible pressure loss
Waste air/gas temperature, max.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
821 m³/h
300 Pa
80 °C
150 mm
150 mm
28993 cfh
0.0435 psi
176 °F
5 15/16“
5 15/16“
531 cm²
82.305 in²
161 mm
160 mm
6 5/16”
6 5/16”
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a backflow of condensate into the machine.
Air intake
Standard Connection:
 Air intake from installation site
Min. air intake cross-section
(to prevent draughts in room)
A sufficient supply of fresh air should be ensured to replace
the air extracted.
Alternative connection: Ducted air intake (from outside
build-ing)
Connector on machine (int. diameter)
Connection pipe provided on site (int. diameter)
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least
900 mm long and secured using two screws.
Technical datasheet: PT 8303 SL EL
Date: 24-Jun-2014
9
Fittings
(supplied)
Machine data
Without base
2 x clamps
4 × screws DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
The machine should be bolted to the floor.
Fixing materials for a floating screed floor are to be provided
on site.
Width
Depth
Height
Casing width
Casing depth
Minimum width of delivery access to installation site
Minimum rear wall gap (measured to front of machine)
Wall gap (to front of machine)
Minimum gap ensures sufficient space for maintenance and
servicing.
6 mm x 40 mm
10 mm x 50 mm
1/4” x 1 9/16”
3/8” x 2”
711 mm
1088 mm
1800 mm
708 mm
999 mm
725 mm
1500 mm
500 mm
28“
42 7/8“
70 7/8“
27 7/8“
39 5/16“
28 9/16“
59 1/16“
19 11/16“
Net weight
Dynamic floor load, max.
Average heat dissipation
(dependent on ambient room temperature and programme
selected)
139 kg
1584 N
473 W
306.4 lbs
Noise level
Sound pressure (re 20 mPA),
workplace-related (at distance of 1 m and height of 1.6 m)
68.9dB (A)
56 dB (A)
1615 BTU/h
Installation should only be carried out by authorized installers in accordance with national regulations! Follow installation
instructions when installing machine!
Technical datasheet: PT 8303 SL EL
Date: 24-Jun-2014
10