Miele | 51613745USA | Spec sheet | Miele 51613745USA Spec Sheet

Installation plan
Washer
PW 6137 EL (Electrically heated)
en - US
12.15
M.-Nr. 09 284 470 / 02
M.-Nr. 09 284 470 / 02
2
PW 6137 EL (measurements in inches)
3
PW 6137 EL (measurements in inches)
4
PW 6137 EL (measurements in inches)
5
PW 6137 EL (measurements in inches)
6
PW 6137 EL (measurements in millimeters)
7
PW 6137 EL (measurements in millimeters)
8
PW 6137 EL (measurements in millimeters)
9
PW 6137 EL (measurements in millimeters)
10
Technical Datasheet
Washer-extractor:
Heating:
PW 6137
Electric (EL)
Legend:
Solid circle around symbol:
Connection mandatory
en - US
Broken circle around symbol:
Connection optional or as required
Optional extras:
UG/
UO
BS
Miele base
Concrete base
Dispensing
pump
UO 6013 (UO = Open base)
Height
Width
Depth
5 11/16“
30 11/16“
35 3/8“
144 mm
780 mm
899 mm
UG 6013 (UG = closed base)
Height
Width
Depth
5 11/16“
31 ½“
35 13/16“
144 mm
800 mm
909 mm
UO 6013-30 (UO = Open base)
Height
Width
Depth
11 13/16“
30 11/16“
35 3/8“
300 mm
780 mm
899 mm
UG 6013-30 (UG = closed base)
Height
Width
Depth
11 13/16“
31 01/2“
35 13/16“
300 mm
800 mm
909 mm
Recommended height
Minimum height
Minimum width
Minimum depth
5 15/16“
3 15/16“
37 3/8“
39 3/8“
150 mm
100 mm
950 mm
1000 mm
External dispensing pumps (2 or 4 head pump):
Voltage (external power supply required)
Fusing
Supplied with supply cable and plug
120V
15A
NEMA 5-15
Machine connections:
Electrical
connection
1. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
(Connection cable not included)
V
Hz
kW
A
4 x AWG 6
3 AC 220-240V
60
17 kW
3 × 50
4 x 10 mm²
2. Standard voltage (convertible)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
(Connection cable not included)
V
Hz
kW
A
4 AWG 6
3 AC 208V
60
14.3 kW
3 × 50
4 x 10 mm²
Technical datasheet: PW 6137 EL (electrically heated)
Date: 03.2015
Page: 11
Electrical connection must comply with national regulations.
Connection using multi-pole lockable wall socket in compliance with IEC/EN 60309 and IEC/EN 60947 is recommended in order to simplify electrical tests. If machines are hardwired, a multi-pole mains switch must be provided on site.
Switches with a contact gap of more than 3 mm can be
used. These include switches, fuses and contactors (IEC/EN
60947). A wall socket or mains isolator must be easily accessible after installation.
Reinstallation of the supply point, changes to the equipment
or checks on the protective conductor, including determination of correct fuse rating, should only be performed by a
properly trained electrician.
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all appropriate
national and local regulations.
Equipotential
bonding
Sleeve with external thread
for washer and nut
3/8 x 1 3/8“
10 × 35 mm
M 10
(Option)
Fitting such as washers and nuts are only supplied with the
OS machine version.
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all appropriate
national and local regulations.
Cold water
(soft water)
Min. water pressure/flow pressure
Max. water pressure/flow pressure
Max. throughput
Max. throughput (if hot or raw water supply is not available)
2 inlet hoses with ¾" threaded union (female)
On-site connection thread
14.5 psi
145 psi
6.9 gal/min
11 gal/min
100 kPa
1000 kPa
26 l/min
42 l/min
Inch
Length of inlet hose
59 1/16“
¾“ garden hose
thread, male
1500 mm
Hourly water demand (average for 60°C cotton program)
determined at cold, hot and raw water connection
Approx. 23.5
gal/h
Approx. 89 l/h
Max. water temperature
Min. water pressure/flow pressure
Max. water pressure/flow pressure
Max. throughput
158°F
14.5 psi
145 psi
4.2 gal/min
70°C
100 kPa
1000 kPa
16 l/min
1 inlet hose with ¾" threaded union supplied.
On-site connection thread
Inch
¾" garden hose
thread, male
Length of inlet hose
59 1/16“
1500 mm
Hourly water demand (average for 60°C cotton program)
determined at cold, hot and raw water connection
If hot water is not available, connect hot water hose to cold
water valve!
Approx. 24.6
gal/h
Approx. 93 l/h
Min. water pressure/flow pressure
Max. water pressure/flow pressure
Max. throughput
14.5 psi
145 psi
8.5 gal/min
100 kPa
1000 kPa
32 l/min
Optional retrofit kit: 2 inlet hoses with ¾" threaded union
(female)
On-site connection thread
Inch
Length of inlet hose
59 1/16“
¾“ garden hose
thread, male
1500 mm
Hourly water demand (average for 60°C cotton program)
determined at cold, hot and hard water connection)
Approx. 15.5
gal/h
Add the hot water requirement to the cold water requirement, if there is no hot water supply available.
If connected to hard water supply, subtract cold water (soft)
volume.
Hot water
(soft water)
Cold water
(hard water)
(Option)
Technical datasheet: PW 6137 EL (electrically heated)
Date: 03.2015
Approx. 55 l/h
Page: 12
Cold water
Liquid
dispensing
(Option)
Waste water
Drain valve
Min. water pressure/flow pressure
Max. water pressure/flow pressure
Max. throughput
14.5 psi
145 psi
1.5 gal/min
100 kPa
1000 kPa
5.5 l/min
1 inlet hose with ¾" threaded union included (optional).
On-site connection thread
Inch
Length of inlet hose
59 1/16“
¾" garden hose
thread, male
1500 mm
Max. waste water temperature
Waste water connection on machine (ext. diameter)
Drain connection on site (int. diameter)
Max. transient throughput
203°F
2 15/16“
2 15/16“
52.9 gal/min
95°C
75 mm [DN 70]
75 mm [DN 70]
200 l/min
5/16 x 3 1/8“
½ x 2 3/8“
8 x 80 mm
12 x 60 mm
5/16 x 3 1/8“
½ x 2 3/8“
8 x 80 mm
12 x 60 mm
5/16 x 3 1/8“
½ x 2 3/8“
8 x 80 mm
12 x 60 mm
Machine width
Machine depth
Machine height
Casing width
Casing depth
31 5/8“
39 9/16“
49 3/16“
31 ½“
35 13/16“
804 mm
1005 mm
1250 mm
800 mm
910 mm
Min. width of delivery access to installation site
Recommended rear wall gap (measured to front of machine)
Minimum rear wall gap (measured to rear of machine lid)
31 7/8“
53 1/8“
15 ¾“
810 mm
1350 mm
400 mm
Net weight
Dynamic floor load, max.
Static floor load, max.
Dynamic load, max.
Drum frequency, max.
Average heat dissipation
(dependent on ambient room temperature and program selected)
751 lb
4290 N
3778 N
503 N
18,3 Hz
5016 BTU/h
340.6 kg
4290 N
3778 N
503 N
18,3 Hz
1.47kW
Sound pressure level (re 20 mPA),
workplace-related
(at distance of 1 m and height of 1.6 m)
69 dB (A
69 dB (A)
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of sufficient cross-section.
Fittings
Without base
The machine must be firmly anchored to the floor!
Anchor fittings included:
2 × angle brackets (from shipping lock)
2 × bolts DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
The floor must be solid and able to support the machine. The
fittings included are suitable for a solid concrete floor. Anchor
bolts and fittings for other floor types must be provided on
site.
On concrete base
The machine must be firmly anchored to the floor!
Anchor fittings included:
2 × angle brackets (from shipping lock)
2 × bolts DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
The grade of concrete should be suitable for the load. The
base should be firmly anchored to the floor to accommodate
dynamic stress!
Miele base
The base must be firmly anchored to the floor!
Anchor fittings included with plinth:
4 × bolts DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
Both the machine and the base must be installed according to
the installation instructions provided.
Machine data
Installation should only be carried out by authorized installers in accordance with valid regulations!
Follow installation instructions when installing machine! All rights reserved!
Technical datasheet: PW 6137 EL (electrically heated)
Date: 03.2015
Page: 13
Download PDF

advertising