U-Line U-1024BEVS-00B Quick start guide

U-Line U-1024BEVS-00B Quick start guide
QUICK START GUIDE
1000 Series
•
115 V / 60 Hz
QUICK START GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations
of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American
leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine
use. U-Line’s complete product collection includes modular Wine Captain® Models, Beverage Centers, Clear Ice Machines,
Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, and Combo® Models.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin with a west coast office located in Laguna Beach,
California and European support in Dublin, Ireland. U-Line has shipped product to five continents for over two decades and is
proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance
Documentation, and Product Warranty information are all available for reference and download at u-line.com under
Documentation.
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.800.779.2547.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
SERVICE INFORMATION
Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our
Customer Care group directly, contact information below.
GENERAL INQUIRIES
SERVICE & PARTS ASSISTANCE
U-Line Corporation
Monday - Friday 8:00 am to 5:30 pm CST
8900 N. 55th Street
T: +1.800.779.2547
Milwaukee, Wisconsin 53223 USA
F: +1.414.354.5696
Monday - Friday 8:00 am to 4:30 pm CST
Service Email: [email protected]
T: +1.414.354.0300
Parts Email: [email protected]
F: +1.414.354.7905
Email: [email protected]
u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
QUICK START GUIDE
Contents
1
Model List
3
Safety and Warning
3
Environmental Requirements
4
Electrical
5
Door Swing
5
General Installation
6
Integrated Panel Installation
8
Control Operation
9
First Use
9
Sabbath Mode
10
Warranty
u-line.com
QUICK START GUIDE
u-line.com
Model List
This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides
for all U-Line products.
Wine Captain® Models
U-1024WCS-00A
U-1215WCS-00A
U-1224WCS-00A
U-1215WCINT-00A
U-1224WCS-13A
U-1215WCB-00A
U-1224WCINT-00A
U-1224WCINT-60A
U-1224WCB-00A
Beverage Centers
U-1024BEVS-00A
U-1224BEVS-00A
U-1224BEVS-13A
U-1224BEVINT-00A
U-1224BEVINT-60A
Solid Door Refrigerators
U-1215RS-00A
U-1224RS-00A
U-1224DWRS-00A
U-1215RINT-00A
U-1224RINT-00A
U-1224DWRINT-00A
U-1215RB-00A
U-1224RB-00A
U-1224RW-00A
1
QUICK START GUIDE
u-line.com
Refrigerator / Freezers
U-1224RFS-00A
U-1224RFINT-00A
U-1224RFB-00A
U-1224RFW-00A
ADA Height Compliant Series
U-ADA24RGLS-13A
U-ADA24RS-13A
U-29RB-00A
U-ADA24RGLB-13A
U-ADA24RB-13A
U-29RB-13A
U-29RB-15A
U-29RW-00A
U-29RW-13A
U-29RW-15A
Outdoor Series
U-1215RSOD-00A
U-1224RSOD-00A
Visit http://www.u-line.com/product-literature/userguides or
scan this QR code to view all user guides online.
2
QUICK START GUIDE
u-line.com
Safety and Warning
! DANGER
NOTICE
This unit contains R600a (Isobutane) which is a
Please read all instructions before installing,
flammable hydrocarbon. It is safe for regular
operating, or servicing the appliance.
use. Do not use sharp objects to expedite
defrosting. Do not service without consulting the
“R600a specifications” section included in the
Use this appliance for its intended purpose only and follow
User Guide. Do not damage the refrigerant
these general precautions with those listed throughout this
circuit.
guide:
SAFETY ALERT DEFINITIONS
! WARNING
Throughout this guide are safety items labeled with a
Danger, Warning or Caution based on the risk type:
Service must be done by factory authorized
service personnel. Any parts shall be replaced
with like components. Failure to comply could
! DANGER
increase the risk of possible ignition due to
incorrect parts or improper service.
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
Environmental Requirements
115 V UNITS
! WARNING
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
Warning means that failure to follow this safety
exposed to natural elements.
statement could result in serious personal injury
or death.
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
! CAUTION
ice production on applicable models.
Caution means that failure to follow this safety
statement may result in minor or moderate
For best performance, keep the unit out of direct sunlight
personal injury, property or equipment damage.
and away from heat generating equipment.
3
QUICK START GUIDE
u-line.com
Electrical
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
! WARNING
evaporate when the humidity drops.
SHOCK HAZARD — Electrical Grounding
Required. Never attempt to repair or perform
! CAUTION
maintenance on the unit until the electricity has
been disconnected.
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
Never remove the round grounding prong from
warranty.
the plug and never use a two-prong grounding
adapter.
OUTDOOR UNITS
This unit is designed to operate between 50°F (10°C) and
Altering, cutting or removing power cord,
100°F (38°C). Higher ambient temperatures may reduce
removing power plug, or direct wiring can cause
the unit’s ability to reach low temperatures and/or reduce
serious injury, fire, loss of property and/or life,
ice production on applicable models.
and will void the warranty.
For best performance, keep the unit out of direct sunlight
Never use an extension cord to connect power to
and away from heat generating equipment.
the unit.
In climates where high humidity and dew points are
Always keep your working area dry.
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
NOTICE
Electrical installation must observe all state and
local codes. This unit requires connection to a
! CAUTION
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
4
QUICK START GUIDE
u-line.com
Door Swing
2. If the unit is not level, adjust the legs on the corners of
the unit as necessary.
Wall
Wall
1/4" Min.
(6 mm)
2-1/8" Min.
(54 mm)
Turn to Adjust
90°
Door Swing
3. Confirm the unit is level after each adjustment and
90°
Door Swing
repeat the previous steps until the unit is level.
INSTALLATION TIP
Units have a zero clearance for the door to open 90°,
If the room floor is higher than the floor in the cutout
when installed adjacent to cabinets.
opening, adjust the rear legs to achieve a total unit rear
height of 1/8" (3 mm) less than the opening’s rear height.
Shorten the unit height in the front by adjusting the front
Stainless Steel and black and white models require 2-1/8"
legs. This allows the unit to be gently tipped into the
(54 mm) door clearance to accommodate the handle if
opening. Readjust the front legs to level the unit after it is
installed next to a wall.
correctly positioned in the opening.
Integrated models require 1/4" (6 mm) clearance if
installed next to a wall. Allow for additional space for any
INSTALLATION
knobs or pulls installed on the integrated panel/frame.
1. Plug in the power/electrical cord.
2. Gently push the unit into position. Be careful not to
entangle the cord.
General Installation
LEVELING INFORMATION
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit’s top
1. Use a level to
confirm the unit is
surface should be approximately 1/8" (3 mm) below
level. Level should
the countertop.
be placed along top
edge and side edge
4. Remove the interior packing material and wipe out the
as shown.
inside of the unit with a clean, water-dampened cloth.
1
5
QUICK START GUIDE
u-line.com
Integrated Panel Installation
6. Secure integrated
panel to door/drawer
1. Fully open door/drawer.
Bar
Clamp
using clamps. A
robust tape may also
be used. U-Line
2. Starting at corner, pull
recommends the use
gasket away from door/
of bar clamps to
drawer.
Door/Drawer
secure the panel to
the door/drawer. If
3. Continue to pull gasket
using tape, be
free from gasket channel.
Wood
Panel
certain the tape will
not damage panel
finish upon removal.
4. Upon removal, lay gasket down on a flat surface.
7. Using a 7/64" (3 mm)
5. The panel should be aligned with the outside edge
(opposite the hinge) and high enough to align with the
drill bit, drill 6 pilot
highest point in the door/drawer.
holes into the wood
Bar
Clamp
panel 1/2" (12 mm)
deep using the holes in the door/drawer frame as a
Align Top Of Panel With Highest Point Of Door/Drawer
guide.
Align Panel
Against
Door/Drawer
Edge First
NOTICE
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardwood is installed.
8. Locate 6 of the #6x 1-1/4" (32 mm) screws provided
with your unit.
NOTICE
Due to differences in floor construction or
9. Using a Phillips screwdriver, place one screw into each
surrounding cabinetry, the panel may not sit
of the 6 pilot holes and screw down. Do not overtighten
flush with the top of the door/drawer.
Panel
screws.
Door
6
QUICK START GUIDE
u-line.com
10.Be sure the screws force their way past the opening on
the gasket channel and sit flush against the bottom of
the channel.
Integrated Panel
Integrated Panel
11.Remove clamps from door/drawer.
NOTICE
If panel requires additional adjustment after
removing clamps, slightly loosen each screw and
adjust panel as necessary. Tighten screws upon
completion.
12.Starting at the corners, re-install the gasket into the
gasket channel in the frame. Make sure the gasket is
fully seated. This may take some force.
7
QUICK START GUIDE
u-line.com
Control Operation
Not Alert
Light Power Used LED
Up Down
CONTROL FUNCTION GUIDE
FUNCTION
COMMAND
DISPLAY/OPTIONS
ON/OFF
Press
and release
Unit will immediately turn ON or OFF.
Press
and release to leave interior
Toggle lights
Adjust refrigerator set
light on for 3 hours
When the “F” or “C” in the display is flashing, press
Press
or
and release
View temperature in unit
Press
and
together and release
Toggle between F/C
Hold
point
and
Glass door wine and beverage centers only.
or
for five seconds
to adjust the set point temperature.
The display will flash and then toggle from set point
to temperature in unit.
The display will change units.
DOOR ALERT NOTIFICATION
When the door is left open for more than 5 minutes:
• An audible tone will sound for several seconds every
minute.
• The Alert LED will blink.
Close door to silence alert and reset.
8
QUICK START GUIDE
u-line.com
First Use
L
All U-Line controls are preset at the factory. Initial startup
Sabbath Mode
requires no adjustments.
1
2
3
4
5
6
NOTICE
U-Line recommends allowing the unit to run
overnight before loading with product.
This unit is Star-K certified and offers a Sabbath mode.
Sabbath mode disables system responses to user initiated
1200 SERIES
activities and all external functions, including lighting,
When plugged in, the unit will begin operating under the
display and audible alarms. The unit will still maintain
factory default settings. If the unit was turned off during
installation, simply press
internal temperatures and set points. View a full list of
and the unit will immediately
switch on. To turn the unit off, press
Star-K certified U-Line units at www.star-k.org.
.
To enable Sabbath Mode:
1024BEV
MECHANICAL DIAL CONTROL
1. Press
The control dial turns unit ON/OFF and sets temperature.
(4) and hold for ten seconds and release (the
°F/°C symbol will flash briefly at the end of the ten
This set point temperature is a base setting used by the
second period).
controller to maintain the temperature zone in the unit.
The factory default MID setting, number 4 set point, is
approximately 38°F (3°C). The set point temperature is a
2. The interior light and control display (3) will go dark
gauge for further temperature adjustments.
until user resets mode.
1024WC
3. NOTE: Although the display will not be visible, the
temperature controls in the unit remain active and
MECHANICAL DIAL CONTROL
preserve the interior temperature.
The control dial turns unit ON/OFF and sets temperature.
This set point temperature is a base setting used by the
controller to maintain the temperature zone in the unit.
Sabbath Mode remains active until
The factory default MID setting, number 3 or 4 set point,
pressed and released.
is approximately 50°F (10°C). The set point temperature
is a gauge for further temperature adjustments.
9
(4) is quickly
QUICK START GUIDE
u-line.com
Warranty
unit is completed and mailed back or electronically
U-LINE CORPORATION LIMITED WARRANTY
apply to cosmetic damages. A proof of purchase may
1. U-Line Corporation (“U-Line”) warrants each U-Line
be required.
submitted to U-Line. This 30 day warranty does not
product to be free from defects in materials and
workmanship for a period of one year (two years on
4. The following conditions are excluded from this limited
Modular 3000 Series) from the date of purchase.
warranty: use of cleaners other than the recommended
U-Line further warrants the sealed system (consisting
stainless steel cleaners and U-Line Clear Ice Maker
of the compressor, condenser, evaporator, hot gas
cleaner; installation charges; damages caused by
bypass valve, dryer, and connecting tube) in each
disasters or acts of God, such as fire, floods, wind, and
U-Line product to be free from defects in materials and
lightning; damages incurred or resulting from shipping,
workmanship for a period of five years from the date of
improper installation, unauthorized modification, or
purchase.
misuse/abuse of the product; customer education
calls; food loss and spoilage; door and water level
adjustments (except during the first 30 days from the
2. During the initial one year warranty period (two years
on Modular 3000 Series) for all U-Line products U-Line
date of installation); defrosting the product; adjusting
shall: (1) repair any product or replace any part of a
the controls; door reversal; and cleaning the
product; and (2) for all Marine, RV, and Domestic
condenser.
U-Line products sold and serviced in the United States
(including Alaska and Hawaii) and Canada, U-Line
5. U-Line products are designed to operate in ambient
shall be responsible for the labor costs performed by a
temperatures between 50°F and 100°F unless
U-Line authorized service company, incurred in
otherwise noted in the product manual. Exposure to
connection with the replacement of any defective part.
temperatures outside this range may cause
During years two through five of the warranty period
degradation of performance and issues, such as lower
for the sealed system, U-Line shall: (1) at U-Line’s
ice production or spoiled contents, that are not
option repair or replace any part of the sealed system;
covered under the terms of this warranty as a result of
and (2) for all Marine, RV, and Domestic U-Line
that exposure. U-Line product may not be subjected to
products sold and serviced in the United States
temperatures below 40°F without following the
(including Alaska and Hawaii) and Canada, U-Line shall
winterization and vacation shutdown procedures in the
be responsible for the labor costs incurred in
user guide.
connection with the replacement of any defective part
of the sealed system. All other charges, including
6. U-Line’s Outdoor Limited Warranty, set forth in this
transportation charges for replacements under this
Paragraph 6 shall apply to U-Line models deemed
warranty and labor costs not specifically covered by
suitable for outdoor use by Underwriters Laboratory
this warranty, shall be the responsibility of the
(“UL”) as noted in the U-Line Product Catalog, U-Line’s
purchaser. This warranty extends only to the original
website, and/or on the serial tag located inside the
purchaser of the U-Line product. The Product
product.
Registration Card included with the product should be
promptly completed by you and mailed back to U-Line,
or you can register on-line at www.u-lineservice.com.
A. Outdoor product may come into contact with rain by
virtue of outdoor use. Exposure to other sources of
water shall also cause this warranty to be void,
3. The warranty listed above does not apply to floor
including flooding of the area in proximity of the unit
display models. The warranty for these models shall
greater than 1/8" deep in water, hurricanes, splashing
be 30 days from the date of retail purchase and only if
U-Line’s Product Registration Card included with the
10
QUICK START GUIDE
u-line.com
of pool water, or directing a spray from a hose or
similar device into and around the unit.
7. If a product defect is discovered during the applicable
warranty period, you must promptly notify either
U-Line at 8900 N. 55th Street, Milwaukee, Wisconsin
53223 USA or at +1.800.779.2547 or the dealer from
whom you purchased the product. In no event shall
such notification be received later than 30 days after
the expiration of the applicable warranty period. U-Line
may require that defective parts be returned, at your
expense, to U-Line’s factory in Milwaukee, Wisconsin,
for inspection. Any action by you for breach of
warranty must be commenced within one year after
the applicable warranty period.
8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR IMPLIED WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH
ARE DISCLAIMED. U-Line’s sole liability, and your
exclusive remedy, under this warranty is set forth in
the paragraphs above. U-Line shall have no liability
whatsoever for any incidental, consequential, or
special damages arising from the sale, use, or
installation of the product or from any other cause
whatsoever, whether based on warranty (express or
implied) or otherwise based on contract, tort, or any
other theory of liability.
Some states do not allow limitations on how long an
implied warranty lasts or the exclusion or limitation of
incidental or consequential damages, so the above
limitations may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights
which vary from state to state.
Warranty 6/2014 Rev.G
Copyright © 2014 U-Line Corporation. All Rights Reserved.
Publication Number 30420 7/2015 Rev.B
11
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement