Air King | FRAS120 | Specification Sheet | Air King FRAS120 Specification Sheet

Air King FRAS120 Specification Sheet
SPECIFICATIONS
FRAS120
EXHAUST FANS
• Grill
103/4"
91/4"
Cold rolled steel, powder coated white.
• Blower Wheel
4"
One piece polymeric wheel, 5.13" diameter, 2.38" wide, with 48
fins.
77/8"
• Motor
Heavy duty, plug-in, permanently split capacitor, 4 pole motor,
life time lubrication, thermally protected.
Rated 120 volts, 60 hz., 0.45 amps.
Contractor Pack (Motor/BladeGrill) Model: FA90T*
5/8"
105/16"
• Fan Housing
24 gauge galvanized steel housing, dimensions 103/4" x 91/4" x 77/8".
Contractor Pack Model: AKFH2*
1215/16"
• Damper
Blanket - Non-asbestos, ceramic blanket
• Duct Collar
Fusible Link - Replaceable, 165°F standard
Metal collar for 4" duct connection, comes complete with built
in back draft damper.
Classification - Ceiling Radiation Damper is ULC classified
and rated for a 3-4 hour fire resistance. U.L. listed 555C.
California State Marshall classification for 1 or 2 hour fire
damper rating. California State Marshall listing number
3225-1374-101.
• Ventilating Area
For rooms up to 150 sq. ft.
Contractor Pack Model: AKFD2*
• Unit Mounting
FRAS120 is centered between joists (with 16" centers) using
hanging brackets. The housing will mount through drywall
thickness up to 3/4", with a rough-in opening of 103/4" x 91/4".
*
Air King Ventilation Products
certifies that the models shown
herein are licensed to bear the
AMCA seal. The ratings shown
are based on tests and procedures
performed in accordance with
AMCA Publication 211 and AMCA
Publication 311 and comply with
the requirements of the Certified
Ratings Program.
Sold in packs of 4. All three parts (housing, damper, motor/blade/grill)
must be purchased and used together to make a complete unit.
C
US
AMCA LICENSED PERFORMANCE
Air Flow - CFM
Sound - SONES
0
131
3.7
0.05
125
3.7
Static Pressure (inches of w.g.)
0.1
0.125
0.15
0.2
120
117
114
107
3.7
3.7
3.7
3.7
0.25
98
3.5
0.3
86
3.5
HVI Sones
@ Ps .1 SP
Fan Speed
RPM
Power
Watts
3.0
1300
43
Performance shown is for FRAS exhaust models for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille, ceiling radiation damper and backdraft
damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The loudness ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a
hemispherical free field calculated per AMCA standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal does not apply to HVI Sones.
PROJECT
ARCHITECT
LOCATION
ENGINEER
CONTRACTOR
SUBMITTED BY
FAN
MODEL
NUMBER NUMBER
CFM
IN
W.G.
RPM
WATTS
AMPS
SONES
QTY
DATE
OPTIONAL EQUIPMENT
& REMARKS
U.S.: 820 Lincoln Drive • West Chester, PA 19380-4466 • Tel: 877-304-3785 • Fax: (610) 696-8048
Canada: 110 Glidden Road • Brampton, Ontario L6T 2J3 • Tel: (905) 456-2033 • Fax: (905) 456-1015
Specifications subject to change without notice.
FRAS120 Updated January 2006
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising