Air King EVFDG Spec Sheet

Air King EVFDG Spec Sheet
SPECIFICATIONS
EVFDG
VARIABLE AIRFLOW DUAL SPEED
EXHAUST FAN
HIGHEST AVAILABLE SPEED: 150 CFM/0.6 Sones @ 0.10 SP.
LOWEST AVAILABLE SPEED: 30 CFM/<0.3 Sones @ 0.10" SP.
• Grill
White, polymeric grill secured in place with torsion springs; easily removed if
necessary, dimensions - 17" x 157/8".
127/8"
123/4"
• Blower Wheel
Balanced polymeric dual inlet blower wheel secured in place using a hex nut.
6"
• Adjustable Capacity Motor
8 capacity settings on low speed allow the fan to be set to the required exhaust
rate for continuous ventilation. Low speed set points include:
30 40 50 60 70 90 100 & 120 CFM
High speed rapidly clears the air of moisture, odors or other contaminants. High
speed set points include: 80 110 130 Boost
Quiet 4 Pole motor, suitable for continuous operation, permanently lubricated,
115/120V 60 Hz., 0.30 amps. Ideal for compliance with Ashrae 62.2, LEED,
ENERGY STAR® for Homes, California Title 24 and other programs.
97/8"
• Motion Sensor
Integrated motion sensor automatically turns fan to high speed when room is
occupied. Adjustable off delay from 30 seconds to 80 minutes.
17"
157/8"
• Fan Housing
23 gauge galvanized steel housing. Overall dimensions: 127/8"x 123/4"x 97/8".
Acceptable for use over
tub or shower when
installed in a GFCI
protected branch circuit.
• Duct Collar
6" round, zinc plated metal collar adapter. Gasketed, spring loaded aluminum
backdraft damper.
• Electrical Connections
0.5" electrical knockouts provided. Easy wiring access via either internal
or external wiring compartment cover.
• Unit Mounting
The housing will mount through drywall thickness up to 3/4", with a
rough-in opening of 131/8" x 13". The housing will mount either between
16" or 24" on center joists, using the 2 supplied housing mounting
brackets. The housing mounting brackets can be adapted for overhead
mounting (hardware not provided). The unit is provided with an optionally
installed ceiling flange to ensure proper building infiltration rates are
maintained and that no air leaks occur between the fan housing and
ceiling cutout.
• Lighting
Electronic Quick Start Ballast – rated 26 Watt. Includes 26 watt,
Quad 4 pin PL lamp. 4 watt night light (night light bulb not included).
• Single Pack Shipping Info
Box Dim: 20" x 157/8" x 113/8"
Shipping Weight: 17 lbs.
SEE REVERSE SIDE FOR STATIC PRESSURE RANGES
PROJECT
ARCHITECT
LOCATION
ENGINEER
CONTRACTOR
SUBMITTED BY
CFM
IN
W.G.
RPM
WATTS
DE IN AMERIC
MA
A
MEE
TS
FAN
MODEL
NUMBER NUMBER
IRE
REQU
ME
N TS O A RRA
F
Specifications subject to change without notice.
AMPS
SONES
QTY
DATE
OPTIONAL EQUIPMENT
& REMARKS
Air King: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 5-16
SPECIFICATIONS
EVFDG
VARIABLE AIRFLOW DUAL SPEED
EXHAUST FAN
High Speed
Set Points (CFM)
ACHIEVABLE STATIC PRESSURES
HIGH SPEED
150 CFM
130 CFM
110 CFM
80 CFM
0.10
0.19
0.26
0.34
Low Speed Set Points (CFM)
0.1 0.15 0.2 0.25 0.3 0.35
Static Pressure Range (inches of W.G.)
LOW SPEED (continuous operation)
120 CFM
0.10
100 CFM
0.18
90 CFM
0.21
70 CFM
60 CFM
50 CFM
40 CFM
30 CFM
0.28
0.31
0.34
0.36
0.38
DE IN AMERIC
MA
A
MEE
TS
0.1 0.15 0.2 0.25 0.3 0.35 0.4
Static Pressure Range (inches of W.G.)
IRE
REQU
ME
N TS O A RRA
F
Specifications subject to change without notice.
Air King: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 5-16
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement