Air King | EF80SH | Spec sheet | Air King EF80SH Spec Sheet

SPECIFICATIONS
EF130SH
EXHAUST FAN
130 CFM/<0.3 Sones @ 0.10" SP.
112 CFM @ 0.25 SP. (Boost)
• Grill
127/8"
123/4"
White, polymeric grill secured in place with torsion springs; easily
removed if necessary, dimensions - 17" x 157/8".
6"
• Blower Wheel
Balanced polymeric dual inlet blower wheel secured in place using a
hex nut.
97/8"
• Motor
Enclosed 4 pole high efficiency, permanently split capacitor motor
(PSC); life time lubrication, suitable for continuous operation. Rated
115/120 volts, 60 Hz.
• Fan Housing
23 gauge galvanized steel housing. Fan housing dimensions:
127/8"x 123/4"x 97/8".
17"
• Humidity Sensor
Acceptable for use over
tub or shower when
installed in a GFCI
protected branch circuit.
Integrated humidity sensor automatically turns fan on until the
desired humidity level is reached.
• Duct Collar
6" round, zinc plated metal collar adapter. 6" spring loaded and
gasketed aluminum backdraft damper.
• Unit Mounting
The housing will mount through drywall thickness up to 3/4", with a
rough-in opening of 131/8" x 13". The housing will mount either
between 16" or 24" on center joists, using the 2 supplied housing
mounting brackets. The housing mounting brackets can be adapted
for overhead mounting (hardware not provided). The unit is provided
with an optionally installed ceiling flange to ensure proper building
infiltration rates are maintained and that no air leaks occur between
the fan housing and ceiling cutout.
• Electrical Connections
0.5" electrical knockouts provided. Easy wiring access via either
internal or external wiring compartment cover.
• Lighting
Electronic Quick Start Ballast – rated 26 Watt. Includes 26 watt,
Quad 4 pin PL lamp. 4 watt night light (night light bulb not included).
EXPANDED PERFORMANCE
Air Flow - CFM
0
149
Static Pressure (inches of w.g.)
0.15
0.2
0.25*
0.3
119
107
91/112
79
0.1
130
157/8"
0.35
62
Sones
@ .1 SP
Fan Speed
RPM
Maximum
Fan Watts
Full Load
Amps
<0.3
783
37.0
0.7
* Boost speed provides 112 CFM @ .25 Static Pressure, 0.6 sones
PROJECT
ARCHITECT
LOCATION
ENGINEER
CONTRACTOR
SUBMITTED BY
CFM
IN
W.G.
RPM
WATTS
DE IN AMERIC
MA
A
MEE
TS
FAN
MODEL
NUMBER NUMBER
IRE
REQU
ME
N TS O A RRA
F
Specifications subject to change without notice.
AMPS
SONES
QTY
DATE
OPTIONAL EQUIPMENT
& REMARKS
Air King: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 2-16