Air King | EVDGH | Spec sheet | Air King EVDGH Spec Sheet

SPECIFICATIONS
EVDGH
VARIABLE AIRFLOW DUAL SPEED
EXHAUST FAN
HIGHEST AVAILABLE SPEED: 150 CFM/0.6 Sones @ 0.10 SP.
LOWEST AVAILABLE SPEED: 30 CFM/<0.3 Sones @ 0.10" SP.
• Grill
White, polymeric grill secured in place with torsion springs; easily
removed if necessary, dimensions - 141/4" x 141/4".
127/8"
123/4"
• Blower Wheel
Balanced polymeric dual inlet blower wheel secured in place using a hex nut.
• Adjustable Capacity Motor
6"
8 capacity settings on low speed allow the fan to be set to the required
exhaust rate for continuous ventilation. Low speed set points include:
30 40 50 60 70 90 100 & 120 CFM
High speed rapidly clears the air of moisture, odors or other
contaminants. High speed set points include: 80 110 130 Boost
Quiet 4 Pole motor, suitable for continuous operation, permanently
lubricated, 115/120V 60 Hz., 0.30 amps. Ideal for compliance with
Ashrae 62.2, LEED, ENERGY STAR® for Homes, California Title 24 and
other programs.
97/8"
141/4"
• Motion Sensor
141/4"
Integrated motion sensor automatically turns fan to high speed when
room is occupied. Adjustable off delay from 30 seconds to 80 minutes.
• Humidity Sensor
Integrated humidity sensor, adjustable up to 80% RH automatically
turns fan to high speed until humidity drops to the desired set point.
Acceptable for use over
tub or shower when
installed in a GFCI
protected branch circuit.
• Fan Housing
23 gauge galvanized steel housing. Overall dimensions:
127/8"x 123/4"x 97/8".
• Duct Collar
6" round, zinc plated metal collar adapter. Gasketed, spring loaded
aluminum backdraft damper.
• Unit Mounting
The housing will mount through drywall thickness up to 3/4", with
a rough-in opening of 131/8" x 13". The housing will mount either
between 16" or 24" on center joists, using the 2 supplied housing
mounting brackets. The housing mounting brackets can be
adapted for overhead mounting (hardware not provided). The unit
is provided with an optionally installed ceiling flange to ensure
proper building infiltration rates are maintained and that no air
leaks occur between the fan housing and ceiling cutout.
• Electrical Connections
0.5" electrical knockouts provided. Easy wiring access via either
internal or external wiring compartment cover.
• Single Pack Shipping Info
Box Dim: 20" x 157/8" x 113/8"
Shipping Weight: 17 lbs.
SEE REVERSE SIDE FOR STATIC PRESSURE RANGES
PROJECT
ARCHITECT
LOCATION
ENGINEER
CONTRACTOR
SUBMITTED BY
CFM
IN
W.G.
RPM
WATTS
DE IN AMERIC
MA
A
MEE
TS
FAN
MODEL
NUMBER NUMBER
IRE
REQU
ME
N TS O A RRA
F
Specifications subject to change without notice.
AMPS
SONES
QTY
DATE
OPTIONAL EQUIPMENT
& REMARKS
Air King: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 2-16
SPECIFICATIONS
EVDGH
VARIABLE AIRFLOW DUAL SPEED
EXHAUST FAN
High Speed
Set Points (CFM)
ACHIEVABLE STATIC PRESSURES
HIGH SPEED
150 CFM
130 CFM
110 CFM
80 CFM
0.10
0.19
0.26
0.34
Low Speed Set Points (CFM)
0.1 0.15 0.2 0.25 0.3 0.35
Static Pressure Range (inches of W.G.)
LOW SPEED (continuous operation)
120 CFM
0.10
100 CFM
0.18
90 CFM
0.21
70 CFM
60 CFM
50 CFM
40 CFM
30 CFM
0.28
0.31
0.34
0.36
0.38
DE IN AMERIC
MA
A
MEE
TS
0.1 0.15 0.2 0.25 0.3 0.35 0.4
Static Pressure Range (inches of W.G.)
IRE
REQU
ME
N TS O A RRA
F
Specifications subject to change without notice.
Air King: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 2-16