Air King | DL4S | Spec sheet | Air King DL4S Spec Sheet

SPECIFICATIONS
DL4S
VARIABLE AIRFLOW
EXHAUST FAN
HIGHEST AVAILABLE SPEED: 130 CFM/0.3 Sones @ 0.10" SP.
LOWEST AVAILABLE SPEED: 30 CFM/<0.3 Sones @ 0.10" SP.
• Grill
White, polymeric grill secured in place with torsion springs; easily
removed if necessary, dimensions - 17" x 157/8".
127/8"
123/4"
• Blower Wheel
6"
Balanced polymeric dual inlet blower wheel secured in place using a hex nut.
• Adjustable Capacity DC Motor
11 capacity settings allow the fan to be set to the required exhaust rate
for continuous ventilation. Set points include:
30 40 50 60 70 80 90 100 110 120 & 130 CFM
97/8"
Quiet DC motor maintains CFM ratings across multiple static pressures,
suitable for continuous operation, permanently lubricated, 115/120V
60 Hz., 0.4 amps. Maximum fan watts @ 0.1 SP.: 7.4 watts
Ideal for compliance with ASHRAE 62.2, LEED, ENERGY STAR® for
Homes, California Title 24 and other programs.
17"
157/8"
• Fan Housing
VENTIL
• Electrical Connections
1
/2" electrical knockouts provided. Easy wiring access via either
internal or external wiring compartment cover.
ARDS
ASHRAE
62.2
AND
6" round, zinc plated metal collar adapter. Gasketed, spring loaded
aluminum backdraft damper.
COMPLIES WITH
ST
Acceptable for use over
tub or shower when
installed in a GFCI
protected branch circuit.
• Duct Collar
IO
N
23 gauge galvanized steel housing. Overall dimensions:
127/8"x 123/4"x 97/8".
AT
• Unit Mounting
• Lighting
GU24 base, 8 Watt 4000K LED Lamp, 725 Lumens (91 Lumens/Watt).
4 watt night light (night light bulb not included).
• Single Pack Shipping Info
Box Dim: 20" x 157/8" x 113/8"
Shipping Weight: 17 lbs.
The housing will mount through drywall thickness up to 3/4", with a
rough-in opening of 131/8" x 13". The housing will mount either
between 16" or 24" on center joists, using the 2 supplied housing
mounting brackets. The housing mounting brackets can be
adapted for overhead mounting (hardware not provided). The unit
is provided with an optionally installed ceiling flange to ensure
proper building infiltration rates are maintained and that no air
leaks occur between the fan housing and ceiling cutout.
SEE REVERSE SIDE FOR STATIC PRESSURE RANGES
PROJECT
ARCHITECT
LOCATION
ENGINEER
CONTRACTOR
SUBMITTED BY
CFM
IN
W.G.
RPM
WATTS
DE IN AMERIC
MA
A
MEE
TS
FAN
MODEL
NUMBER NUMBER
IRE
REQU
ME
N TS O A RRA
F
Specifications subject to change without notice.
AMPS
SONES
QTY
DATE
OPTIONAL EQUIPMENT
& REMARKS
U.S.: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Canada:
Brampton, Ontario
Tel: 905-456-2033
Fax: (905) 456-1015
Updated 3-18
SPECIFICATIONS
DL4S
VARIABLE AIRFLOW
EXHAUST FAN
Set Points (CFM)
ACHIEVABLE STATIC PRESSURES
130 CFM
120 CFM
110 CFM
100 CFM
90 CFM
80 CFM
70 CFM
60 CFM
50 CFM
40 CFM
30 CFM
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.25
DE IN AMERIC
MA
A
MEE
TS
0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55
Static Pressure Range (inches of W.G.)
IRE
REQU
ME
N TS O A RRA
F
Specifications subject to change without notice.
U.S.: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Canada:
Brampton, Ontario
Tel: 905-456-2033
Fax: (905) 456-1015
Updated 3-18
Download PDF

advertising