Dacor REMP16 Planning Guide [805 KB]
REMP3, REMP16
Revised 10/16/13 Page 1/3
Document # PG09-003
PLANNING
GUIDE
Renaissance® Remote Blowers
± 1/16” (± 1.6 mm) unless otherwise stated
warning
19” (48.3 cm)
17 3/8” (44.1 cm)
9 1/2” (24.1 cm)
7 1/2”
(19.1 cm)
4”
(10.2 cm)
2 1/8”
(5.4 cm)
25 1/2”
(64.8 cm)
CL
Intake collar
Cutout location
11” W x 12 5/8” H
(27.9 cm X 32.1 cm)
Exhaust
•
This appliance must be installed in accordance
with the hood or downdraft vent system
installation instructions.
9 1/4”
(23.5 cm)
8” Nom.
(20.3 cm)
CL
24 1/4”
(61.6 cm)
Observe all governing codes and ordinances
during planning and installation. Contact your
local building department for further information.
3 5/8”
(9.2 cm)
CL
Power supply
conduit hole
7 15/16”
(20.2 cm)
5 13/16”
(14.8 cm)
•
Intake collar
Mounting
flange
Discharge
REMP3 overall dimensions
(Top and Side Views)
26” (66.0 cm)
24 1/4” (61.6 cm)
11 1/2”
(29.2 cm)
9 9/16”
(24.3 cm)
13 1/8”
(33.3 cm)
9 1/2”
(24.1 cm)
4”
(10.2 cm)
2 1/8”
(5.4 cm)
3 5/8”
(9.2 cm)
CL
Power supply
conduit
location
12 1/4”
(31.1 cm)
10” Nom.
(25.4 cm)
CL
32 1/4”
(81.9 cm)
33 1/2”
(85.1 cm)
CL
Intake collar
Cutout location
13” W X 16 5/8” H
(33.0 cm X 42.2 cm)
Exhaust
Intake collar
Mounting
flange
Discharge
REMP16 overall dimensions
(Top and Side Views)
Model No.
REMP3
REMP16
Electrical Supply
Requirements
Maximum Duct
Length
Refer to downdraft
vent or hood
specifications
Refer to downdraft
vent or hood specifications
Total Connected
Load
Blower Rating*
Approximate
Shipping Weight
120 Vac, 3.8 Amp.
600 CFM (nominal)
620.5 CFM (actual)
35 lbs.
120 Vac, 2.7 Amp.
1000 CFM (nominal)
994.8 CFM (actual)
55 lbs.
Finish
Galvanized
(may be painted)
* At 0" static pressure
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
REMP3, REMP16
Revised 10/16/13 Page 2/3
Document # PG09-003
PLANNING
GUIDE
Renaissance Remote Blowers
Static pressure - inches of water
REMP3 Blower Performance
5.0
4.0
3.0
2.0
1.0
0
100 200 300 400 500 600
Airflow CFM (Cubic feet/minute)
700
Static pressure - inches of water
REMP16 Blower Performance
2.5
2.0
1.5
1.0
0.5
0
200 400 600 800 1000
Airflow CFM (Cubic feet/minute)
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
REMP3, REMP16
Revised 10/16/13 Page 3/3
Document # PG09-003
PLANNING
GUIDE
Renaissance Remote Blowers
Wiring/conduit
of
Wiring/conduit
Duct
Wall
example REMP
Roof Installation
SIDE VIEW
example REMP
wall Installation
SIDE VIEW
(Exhaust must
point down)
Exhaust
Duct
Blower
ust
a
Exh
Ro
r
we
Blo
No obstructions
within 15 inches of exhaust
Roof curb
Prevailing
wind
Blower
discharge
REMP flat roof installation
Top AND Side Views (see note 2)
+/- 1/16” (+/- 1.6 mm) unless otherwise stated
2"
(5.1 cm)
2”
(5.1 cm)
25 1/2"
(64.8 cm)
33 1/2”
(85.1 cm)
6”
(15.2 cm)
6"
(15.2 cm)
2"
(5.1 cm)
19"
(48.3 cm)
2”
(5.1 cm)
23 ¼"
(59.1 cm)
REMp3
roof curb dimensions
26"
(66.0 cm)
30 1/2”
(77.6 cm)
REMp16
roof curb dimensions
NOTE:
1.
2.
3.
4.
The REMP chassis may be rotated to clear obstructions. 15” (38.1 cm) min. clearance must be maintained from the air
discharge to any obstruction. In cold climates, take into account snow accumulation which can also act as an obstruction.
When mounting in a horizontal position, shield the REMP to protect from possible water collection in the chassis. Maintain
a minimum down slope of 1/4” (6 mm) per foot for evacuation of water.
When the REMP is installed on to a flat (less than a 2:12 pitch) roof, a roof curb is required.
The blower discharge must be pointed in the same direction as the prevailing wind.
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093