Dacor | CABP3 | Planning Guide [489 KB] | Dacor CABP3 Planning Guide [489 KB]

CABP3
Revised 10/16/13 Page 1/1
Document # PG09-001
PLANNING
GUIDE
Renaissance® Cabinet Blower
Total Connected
Load
Blower Rating*
(CFM)
Approximate
Shipping Weight
4 Amps. @
120Vac, 60 Hz
600 Nominal
585.6 Actual
34 lbs.
warning
* At zero inches static pressure. Performance varies based on
duct system configuration.
NOTE: See downdraft vent Planning planning guide for
approved applications.
•
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
•
This appliance must be installed in accordance with the
downdraft vent installation instructions.
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated
17" (43.2 cm)
Ø 7/8" (2.2 cm)
(Grommet Hole)
2" (5.1 cm)
5 3/4"
(14.6 cm)
1/2" (1.3 cm)
19 3/8"
(49.2 cm)
3 3/4"
(9.5 cm)
18 7/8"
(47.9 cm)
Electrical Location Side View
17"
(43.2 cm)
9 3/4"
(24.8 cm)
17 7/8" (45.4 cm)
18 3/8" (46.7 cm)
3"
(7.6 cm)
18 7/8" (47.9 cm)
top view
duct location side view
Static pressure - inches of water
CABP3 Blower Performance
5.0
4.0
3.0
2.0
1.0
0
100 200 300 400 500 600
Airflow CFM (Cubic feet/minute)
Electrical Wiring
Access Hole
3/8” (9 mm)
mounting flange
around perimeter
iso view
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
Download PDF