Best | ILB3 | Installation guide | Best ILB3 Installation Guide

Best ILB3 Installation Guide
MODEL ILB3
Page 1
IN-LINE BLOWER
READ AND SAVE THESE INSTRUCTIONS
!
FOR DOMESTIC COOKING ONLY
!
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to
a GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such as
an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further information and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
! “TYPICAL INSTALLATION”
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (Horizontal blower discharge)
- Wiring
! “MOUNTING OPTIONS”
! “WIRING PLATE POSITION”
! “DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (Vertical blower discharge)
! “USE AND CARE”
! “SERVICE PARTS”
! “WARRANTY”
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
MODEL ILB3
Page 2
TYPICAL INSTALLATION
TYPICAL INSTALLATION
MOUNTING (New Frame Construction)
MOUNTING USING HANGER KIT (included)
10” ROUND DUCT
8” TO 10” ROUND TRANSITION
ADDITIONAL
1½” FRAMING
HANGER
KIT BOLT
& WASHER
10” ROUND
DUCT
EXTENSION
SPRING
Blower
factoryshipped
in straight
through
discharge
position.
10” ROUND
DUCT (INTAKE)
HANGER
KIT CHAIN
CEILING JOIST
(16” centers
shown)
Mounting brackets factoryshipped in position for
½” ceiling material.
MOUNTING SCREW
HANGER KIT
EYE-BOLT
8” TO 10”
ROUND
TRANSITION
HANGER
KIT NUT &
WASHER
Factory-shipped unit installed in new construction.
MOUNTING
BRACKET
MOUNTING (Existing Frame Construction)
8” TO 10” ROUND TRANSITION
GRILLE NUT
(Install into
square holes in
housing)
10” ROUND
DUCT
(OUTLET)
10” ROUND DUCT
(OUTLET)
ACCESS
PANEL SCREW
ACCESS PANEL
CEILING JOIST
(16” centers
shown)
Blower factory-shipped in straight-through
discharge position.
DUCTING (Horizontal blower discharge)
MOUNTING
BRACKETS
(Attached to
opposite sides
of housing &
upside-down)
10” ROUND
DUCT
(INTAKE)
ROOF CAP
2 X 4 FRAMING
(wide side down)
ROUND DUCT
Blower factory-shipped in straight-through
discharge position.
IMPORTANT: Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork. Use
duct tape to make ductwork connections secure and air-tight.
Remove shipping ring from blower inlet
Remove the shipping ring from the blower inlet before operating
the ventilator.
ROUND
ELBOW
WALL
CAP
Two ways to connect ductwork to a factory-shipped unit.
MODEL ILB3
Page 3
WIRING
WIRING PLATE POSITION
BLACK
TO
BLACK
TOP / BACK
OF HOUSING
GROUND TO
WIRING PLATE
VERTICAL
POWER
CABLE
CONNECTION
WIRING
PLATE
120 VAC
LINE IN
(from
range
hood)
WHITE
TO
WHITE
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
¼-20 hex nuts secure mounting brackets to housing. Loosen and
re-tighten or remove and replace nuts as necessary for desired
mounting bracket position.
yy
;;
12¼"
yyy
@@@
;;;
;;;;;;;
yyyy
yyy
Mounting brackets in
factory-shipped position.
(Outlet parallel to joists.)
(New construction)
12¼"
12¼"
DUCT
CONNECTOR
yyyy
;;;;
Change
blower &
duct
connector
positions for
right angle
discharge.
Mounting brackets flipped
over and mounted to outlet
sides of housing.
;;;;;
yyy
yy
(Outlet perpendicular to joists.)
(New construction)
12¼"
10 3/ 4"
to
11 3/ 4"
(Outlet parallel to joists.)
(New or existing construction)
12¼"
BLOWER
BLOWER
Blower and duct connector
in straight through discharge position.
(Factory shipped)
Blower and duct connector
in right angle discharge
position.
DUCTING (Vertical blower discharge)
(Outlet parallel to joists.)
(New construction)
yyy
;;;;;;;
yyyy
Mounting brackets mounted
to top of sides of housing.
yyyy
;;;;
Mounting brackets flipped
over to give approx. 1”
more clearance.
91/ 2"
to
101/ 2"
12¼"
DUCT
CONNECTOR
(Outlet parallel to joists.)
(Existing construction)
Mounting brackets mounted
to outlet sides of housing.
yy
;;
BLOWER DISCHARGE POSITIONS
1½"
to
2½"
11/ 2"
to
21/ 2"
yyy
;;;
Wiring plate mounts to side or top of housing.
DUCTING OPTIONS
MOUNTING OPTIONS
11/ 8"
MAX.
HORIZONTAL POWER
CABLE CONNECTION
ROOF CAP
ROUND
DUCT
yyyy
;;;;
Mounting brackets flipped
over and mounted to top of
sides of housing.
(Outlet parallel to joists.)
(New or existing construction)
Typical ductwork connection to a ventilator converted to
right angle discharge.
MODEL ILB3
USE AND CARE
Follow wiring instructions packed with range hood, and adhere to
all local and state codes, and the National Electrical Code.
WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.
Page 4
To clean blower assembly: Remove access panel, unplug blower
from housing, remove blower mounting nuts, and carefully remove
blower from housing. Use appropriate vacuum attachment or a
soft cloth and mild soap or detergent to clean blower discharge
area and wheel. DO NOT ALLOW WATER TO ENTER MOTOR.
Make sure blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
24
SERVICE PARTS
KEY NO. PART NO.
1
97014736
2
97014728
3
97014761
4
99390099
5
99150415
6
98005513
7
99400035
8
98005512
9
99150471
10
97014775
11
98009399
12
99020273
13
99080485
14
99260558
15
99250959
16
99100491
+
97016792
17
18
19
20
21
22
23
24
25
99260477
97006039
98009417
99420470
99150472
99150591
97016791
S414
97014597
DESCRIPTION
Housing Assembly
Mounting Bracket (2 req.)
Damper Assembly (8” dia.)
Duct Connector (8” dia.)
Screw, 8-18 x ¼ (12 req.)*
Wire Box Cover
Strain Relief Bushing
Wiring Plate
Ground Screw, 10-32 x ½ (2 req.)
Scroll Assembly
Inlet Ring
Blower Wheel
Motor
Lock Nut, 8-32 (4 req.)*
Washer (4 req.)*
Grommet (4 req.)
Blower Assembly, Complete
(Includes Key Nos. 5 & 10-16)
Nut, ¼-20 (6 req.)*
Wire Harness
Access Panel
Cover Nut (2 req.)
Cover Mounting Screw (2 req.)
Screw, 10-16 x 7/8 (4 req.)*
Hanger Kit
Transition 8-10” Round
Rough-In Kit
Order replacement parts by PART NO. - not by KEY NO.
* Standard hardware - may be purchased locally.
+ Not shown assembled.
WARRANTY
23
8
3
5
5
2
9
22
1
5
20
4
17
5
5
22
6
7
18
11
16
12
13
10
BLOWER
ASSEMBLY
14
15
19
25
17
21
BROAN ONE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date
of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any
products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to
recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE
OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan at the address or phone number stated below (b) give the model number and part identification and (c) describe the
nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Best by Broan, P.O. Box 140, Hartford, WI 53027 (1-800-637-1453)
99043699C