Dacor | DHICH | Others PDF [1.5 MB] | Dacor DHICH Others PDF [1.5 MB]

Ventilation Solutions
1
Ventilation Facts
POLLUTANTS TO REMOVE FROM THE KITCHEN
Heat, Odors, Grease,
Gases, Steam & Smoke
FACTORS THAT NEGATIVELY INFLUENCE
VENTILATION
Open Windows & Doors, Air Conditioning Vents,
Ceiling Fans, Island Cooking, Foot Traffic
GENERAL RULE OF THUMB
100 CFM for every 10,000 BTU
(*Increase if duct run is long or complicated)
Two Types of Ventilation
Power Sources
Factors to Consider
Width & Depth of Cooking Product
1
OVERHEAD
Hoods
Powerpacks
Over-the-Range
Microwaves (OTR)
Capture Area: Width, Height & Depth
Internal Blowers
External Blowers:
REMP3, REMP16
ILHSF8, ILHSF10
Mounting Height (see chart)
Blower Size
Duct Diameter:
Use Manufacturer’s
Recommendation
Duct Length (see chart)
2
DOWNDRAFT
RV
ERV
ERV-ER
PRV
Internal Blowers:
CABP3 (RV only)
Width & Depth of Cooking Product
External Blowers:
REMP3, REMP16
Duct Diameter:
Use Manufacturer’s
Recommendation
In-Line Blowers:
ILHSF8, ILHSF10
Blower Size
Duct Length (see chart)
HVAC Experts recommend
Ventilation Solutions
2
Ventilation Facts
Hoods: EH/EHR/MH - Bottom of the hood should be 25” minimum above
the cooktop surface. DHI, DHW, PHW - Bottom of the hood should
be 30” minimum above the cooktop surface.
PowerPacks (with SS Liner): Bottom of liner should be 36" from the
finished counter.
RECOMMENDED
MOUNTING HEIGHTS
OTR (above electric cooking): Top of microwave should be 34" above
the finished counter.
OTR (above gas cooking): Top of microwave should be 36" above the
finished counter. (36" mandatory above ERD30, ER30D, ER30DSR and
EGR30)
*In hoods or Powerpacks, if you must install the hood higher than the recommended
height, it is very important that you increase the size (width) of the hood and the power
(CFM) to provide the best possible ventilation.
Elbows & Transitions count extra-you must add to straight run
to get the total duct run.
90º, 8" Round=7'
90º, 10" Round=5'
45º, 8" Round=3'
90º, Rectangle=15'
45º, 10" Round=2' 90º, Flat Rectangle Elbow=20'
RECOMMENDED DUCT LENGTHS
(VARIES BY PRODUCT)
Straight Transition, 8" or 10" Rd to 3 1/4" x 10" Rectangle = 4'
Elbow Transition, 8" or 10" Rd to 3 1/4" x 10" Rectangle = 25'
8" Round: 60' max
10" Round: 50' max
3 1/4" x 10" Rectangle: 50' max
Keep duct run as short as possible.
Whenever possible, use round duct instead of rectangle.
Do not use back to back elbows – 24" minimum between elbows.
Do not use flex duct.
DO’S & DONT’S
Do not use duct smaller then the recommended size – and never reduce!
Seal ductwork with duct tape and use screws to support weight.
Match roof or wall cap with duct size.
In Pro, Island cooking, we recommend you oversize the hood a minimum of 6".
Support and insulate duct to reduce all noise and vibration.
Ventilation Solutions
3
Pro-Style Hoods
18" Epicure Hoods
18" High, 267/8" Deep
EH5418, EH4818, EH4218, EH3618, EH3018,
EHR5418, EHR4818, EHR4218, EHR3618,
EHR3018
WIDTHS
54", 48”, 42”, 36” and 30”
FINISHES
Stainless Steel in standard Chrome trim. Three trim finish options are
available in Black Chrome, Brass or Copper.
INTERNAL POWERED–EH MODELS
600 CFM (582 CFM at 0.0” static pressure) - EH4218, EH3618 & EH3018
1200 CFM (1164 at 0.0” static pressure) - EH5418, EH4818
EXTERNAL POWERED–EHR MODELS (REMOTE BLOWER OPTION) - only
one blower allowed per installation)
EHR3018 or EHR3618- Use REMP3 or REMP16; ILHSF8 or ILHSF10
EHR4218, EHR4818 or EHR5418 – Use REMP16 or ILHSF10
VENTING
Vents out the top (vertically) or back (horizontally)
42”, 36” & 30” hoods – 8” round single outlet
54” & 48” hoods – 8” round dual outlets, may use AHT10 to transition
into a single 10” round exhaust
CONTROLS
Hood switch will control integrated or remote blowers at 4 speed
settings
DUCT COVERS
Available in all standard widths – 6," 12" or 18" heights
12" Epicure Hoods
12" High, 267/8" Deep
EH4812, EH4212, EH3612, EH3012
EHR4812, EHR4212, EHR3612, EHR3012
WIDTHS
48”, 42”, 36” and 30”
FINISHES
Stainless Steel in standard Chrome trim. Three trim finish options
are available in Black Chrome, Brass or Copper.
INTERNAL POWERED–EH MODELS
600 CFM (582 CFM at 0.0” static pressure) - EH4212 or EH3612 or
EH3012
1200 CFM (1164 at 0.0” static pressure) - EH4812
EXTERNAL POWERED–EHR MODELS (REMOTE BLOWERS OPTIONonly one blower allowed per installation)
EHR4212 or EHR3612 or EHR3012 - Use REMP3; ILHSF8
EHR4812 - Use REMP16; ILHSF10
VENTING
Vents out the top (vertically) or back (horizontally)
30", 36" or 42" hoods – 8" round single outlet
48” hoods – 8” round dual outlets, may use AHT10 to transition
into a single 10” round exhaust
CONTROLS
Hood switch will control integrated or remote blowers at 4 speed
settings
DUCT COVERS
Available in all standard widths – 6," 12" or 18" heights
Ventilation Solutions
4
Millennia Hoods
18" Millennia Hoods
18" High, 251/2" Deep
MH4818, MH3618, MH3018
WIDTHS
48", 36” and 30”
FINISH
Stainless Steel
INTERNAL POWERED–MH MODELS
600 CFM (582 CFM at 0.0” static pressure) - MH3618 or MH3018
1200 CFM (1164 at 0.0” static pressure) - MH4818
VENTING
Vents out the top (vertically) or back (horizontally)
36” & 30” hoods- 8” round single outlet
48” – 8” round dual outlets, may use AHT10 to transition
into a single 10” round exhaust
CONTROLS
Hood switch will control integrated blowers at 4 speed settings.
DUCT COVERS
Available in all standard widths – 6," 12" or 18" heights
12" Millennia Hoods
12" High, 251/2" Deep
MH4812, MH3612, MH3012
WIDTHS
48", 36” and 30”
FINISH
Stainless Steel
INTERNAL POWERED–MHD MODELS
600 CFM (582 CFM at 0.0” static pressure) – MH3012 or MH3612
1200 CFM (1164 at 0.0” static pressure) – MH4812
VENTING
Vents out the top (vertically) or back (horizontally)
36" & 30" hoods – 8" round single outlet
48" hoods - 8" round dual outlets, may use AHT10 to transition
into a single 10" round exhaust
CONTROLS
Hood switch will control integrated blowers at 4 speed settings
DUCT COVERS
Available in all standard widths - 6," 12" or 18" heights
Ventilation Solutions
5
EH and MH Hoods
Blower Performance Curves
Centrifugal Blower
2.10
1.80
3
ed
Spe
1.20
1.50
1.25
1.00
.30
.25
Sp
ee
d
d3
ee
Sp
.50
1
d
ee
Sp
.75
0
4
0
130
195
260
325
390
455
545
50
3
2.00
1.75
250
300
350
400
1
2.10
1.80
1.50
ed
Spe
.90
3
d4
ee
Sp
.75
200
2.40
1.20
d3
ee
Sp
d2
ee
Sp
1.00
150
1
eed
Sp
1
1.25
100
2
ed
Spe
d
ee
Sp
1.50
Static pressure - inches of water
65
Static pressure - inches of water
1.75
.60
d
ee
Sp
.50
2
2.00
d2
ee
Sp
d4
ee
Sp
.90
1
ed
Spe
1.50
Static pressure - inches of water
1
2.40
2
ed
Spe
Static pressure - inches of water
ø 146mm 4-speed
.60
4
.30
.25
0
0
50
100
150
200
250
300
Ventilation Solutions
350
400
65
130
195
260
325
390
455
545
6
Millennia Hoods
Millennia Island Hoods - DHI602, DHI542, DHI482, DHI421, DHI361
WIDTHS 60”, 54”, 48”, 42” & 36”
FINISH Stainless Steel
INTERNAL POWERED
1200 CFM (1164 at 0.0” static pressure) - DHI602, DHI542,
DHI482
600 CFM (582 CFM at 0.0” static pressure) - DHI421, DHI361
VENTING
Vents out the top (vertically), 8” round
Millennia Chimney Hoods - DHW482, DHW421, DHW361, DHW301
WIDTHS 48”, 42”, 36” & 30”
FINISH Stainless Steel
INTERNAL POWERED
1200 CFM (1164 at 0.0” static pressure) - DHW482-1200 CFM
600 CFM (582 CFM at 0.0” static pressure) - DHW421,
DHW361 & DHW301
VENTING
Vents out the top (vertically), 8” round
Millennia Chimney Hoods PHW plus choice of PHG36 or PHG30 Glass
WIDTHS 36" & 30"
FINISHES PHW is in Stainless and must order the Glass Canopy
either PHG36 or PHG30 in 6 Preference Color Options: Anthracite
Gray (AG), Titanium Silver (TS), Sterling Grey (SG), Slate Green
(GN), Blue Water (BU) and Black (BK) to complete the hood.
INTERNAL POWERED
600 CFM (582 CFM at 0.0” static pressure) - PHW + PHG36+
Color Choice
600 CFM (582 CFM at 0.0” static pressure) - PHW + PHG30+
Color Choice
VENTING
Vents out the top (vertically), 8” round
Ventilation Solutions
7
PowerPacks
IVS1 or IVSR1
DIMENSIONS
22 5⁄8" wide, 12 1⁄4" deep, 6" high
INTERNAL POWERED – IVS1
600 CFM (582 CFM at 0.0” static pressure)
EXTERNAL POWERED – IVSR1 (REMOTE BLOWER OPTION only one blower allowed per installation)
Use REMP3 – 600 CFM (572 CFM at 0.0” static pressure)
Use ILHSF8 – 600 CFM (650 CFM at 0.0” static pressure)
VENTING
Vents out the top (vertically) – 8" round
OPTIONAL STAINLESS STEEL LINERS
IHL36 for 36" Decorative Hoods
IHL30 for 30" Decorative Hoods
IVS2 or IVSR2
DIMENSIONS
34 1⁄2" wide, 12 1⁄4" deep, 6" high
INTERNAL POWERED – IVS2
1200 CFM (1164 at 0.0” static pressure)
EXTERNAL POWERED – IVSR2 (REMOTE BLOWER OPTION only one blower allowed per installation)
Use REMP16–1000 CFM (980 CFM at 0.0” static pressure)
Use ILHSF10–1100 CFM (1116 CFM at 0.0” static pressure)
VENTING
Vents out the top (vertically)– (2) 8" round ducts
Use Dacor ATD10 transition to (1) 10" round exhaust
OPTIONAL STAINLESS STEEL LINERS
IHL54 for 54" Decorative Hoods
IHL48 for 48" Decorative Hoods
IHL42 for 42" Decorative Hoods
Ventilation Solutions
8
Blower Performance Curve
IVS1
Static pressure - inches of water
IVS1
.75
.60
.45
.30
.15
0
100
200
300
400
500
600
Airflow CFM (Cubic feet/minute)
Ventilation Solutions
9
Over the Range Microwaves
PMOR3021
FINISHES
Stainless Steel, Black or White
INTERNAL POWERED
300 CFM
VENTING
Vents out the top (vertically) or the back (horizontally)
3 1⁄4" x 10" rectangle duct
SPECIAL NOTES
Factory set for NON-VENTED MODE (Recirculating before installation)
Must turn motor 1/4 turn to change to VENTED
Only "UL" approved Over the Range Microwave/Hood to go over 30" wide
gas or electric products.
Must use deflector shield (supplied) and proper mounting height.
PCOR30 Convection Model
FINISHES
Stainless Steel, Black or White
INTERNAL POWERED
300 CFM
VENTING
Vents out the top (vertically) or the back (horizontally)
3 1⁄4" x 10" rectangle duct
SPECIAL NOTES
Factory set for NON-VENTED MODE (Recirculating before installation)
Must turn motor 1/4 turn to change to VENTED
Only "UL" approved Over the Range Microwave/Hood to go over 30" wide
gas or electric products.
Must use deflector shield (supplied) and proper mounting height.
Ventilation Solutions
10
Downdraft Systems
RV46, RV36, RV30
SIZES 46," 36" & 30"
FINISHES Stainless Steel, Black or White
INTERNAL POWERED Use CABP3 blower – 600 CFM
EXTERNAL POWERED (REMOTE BLOWER OPTION - only one blower
allowed per installation)
REMP3–600 CFM, 8" round duct (572 CFM at 0.0” static pressure)
REMP16–1000 CFM, 10" round duct (980 CFM at 0.0” static
pressure)
ILHSF8-600 CFM (650 CFM at 0.0” static pressure), 8” round duct
ILHSF10-1100 CFM (1116 CFM at 0.0” static pressure), 10” round duct
VENTING
Three options: right or left sides, or bottom
SPECIAL NOTES See pages 12, 13 and 16 for selection of products to
match this downdraft system.
ERV30/36/48, ERV36-ER, ERV48-ER
SIZES 48" 36" & 30"
FINISHES Stainless Steel only
EXTERNAL POWERED (REMOTE BLOWER OPTION - only one blower
allowed per installation)
REMP3 –600 CFM, 8" round duct (572 CFM at 0.0” static pressure)
REMP16–1000 CFM, 10" round duct (980 CFM at 0.0” static
pressure)
ILHSF8-600 CFM (650 CFM at 0.0” static pressure), 8” round duct
ILHSF10-1100 CFM (1116 CFM at 0.0” static pressure), 10” round duct
VENTING
Transition ATD-2 included
Four optional exhaust directions: right or left sides, bottom or back
SPECIAL NOTES See pages 12, 13 and 16 for selection of products to
match this downdraft system.
ERV48-ER is designed for ER48D Range only
ERV36-ER is designed for ER36D Range only
PRV46, PRV36, PRV30
SIZES 46," 36" & 30"
FINISHES Stainless Steel, Black or White
EXTERNAL POWERED (REMOTE BLOWER OPTION - only one blower
allowed per installation)
REMP3 –600 CFM, 8" round duct (572 CFM at 0.0” static pressure)
REMP16–1000 CFM, 10" round duct (980 CFM at 0.0” static pressure)
ILHSF8-600 CFM (650 CFM at 0.0” static pressure), 8” round duct
ILHSF10-1100 CFM (1116 CFM at 0.0” static pressure), 10” round duct
VENTING
Transition ATD-2 included
Four optional exhaust directions: right or left sides, bottom or back
SPECIAL NOTES See pages 12, 13 and 16 for selection of products to
match this downdraft system.
Ventilation Solutions
11
Accessories
Remote Blower
Internal Blower
REMP3 (shown) - 600 CFM
CABP3 - 600 CFM
REMP16 - 1,000 CFM
APPLICATIONS:
APPLICATIONS:
Use with EHR, IVSR,
RV, ERV or PRV
systems
Stainless Steel Liners
for PowerPacks
Install with RV
model downdrafts
only
Stainless Steel Duct Covers
SIZES
SIZES
Available in five widths:
54," 48," 42," 36" & 30"
Available in five widths:
54," 48," 42," 36" &
30"All widths available
in three heights:
6," 12" & 18
IHL36 & IHL30
Use with IVS1 & IVSR1
IHL54, IHL48 & IHL42
Use with IVS2 & IVSR2
Transition Duct
Remote Control Speed Switch
ATD10
ARSC
Use with all IVS2 &
IVSR2.
Install as remote control for
all blower systems except
EH/EHR/MH Hoods
Use with EHD, EHDR4809,
EHDR4209 & MHD4809.
Used to connect dual
exhaust into a
single 10" round exhaust.
ARLC
To control lights except
EH/EHR/MH Hoods
ARSLC
To control both blower &
lights except EH/EHR/MH
Hoods
Transition Duct
AHT10
Use with EH5418, EHR5418,
EH4818, EHR4818, EH4812,
EHR4812, MH4818, & MH4812.
Used to connect dual
exhaust into a
single 10" round exhaust.
Ventilation Solutions
12
Static pressure - inches of water
Blower Performance Curve
REMP3
REMP3
4.00
3.50
3.00
2.50
2.00
1.50
1.00
.50
0
100
200
300
400
500
600
700
Airflow CFM (Cubic feet/minute)
Ventilation Solutions
13
Blower Performance Curve
REMP16
Static pressure - inches of water
REMP16
2.50
2.00
1.50
1.00
.50
0.00
200
400
600
800
1000
1200
Airflow CFM (Cubic feet/minute)
Ventilation Solutions
14
Blower Performance Curve
CABP3
Static pressure - inches of water
CABP3
4.00
3.50
3.00
2.50
2.00
1.50
1.00
0.50
0.00
100
200
300
400
500
600
700
Airflow CFM (Cubic feet/minute)
Ventilation Solutions
15
In-Line Blowers
ILHSF8
POWER
600 CFM (650 CFM at 0.0” static pressure)
VENTING
8" round duct
APPLICATIONS
In-line Blower for a remote application
MAKE-UP OR REPLACEMENT AIR SYSTEM
Have your builder contact their HVAC contractor to
see if this is required in your area.
ILHSF10
POWER
1100 CFM (1116 CFM at 0.0” static pressure)
VENTING
10" round duct
APPLICATIONS
In-line Blower for a remote application
MAKE-UP OR REPLACEMENT AIR SYSTEM
Have your builder contact their HVAC contractor to
see if this is required in your area.
Ventilation Solutions
16
Creating the Proper Ventilation System 1
Select Cooking Product
COOKING PRODUCT
MODEL
HOOD
INTEGRATED VENT
SYSTEM
OVER THE RANGE
(OTC)
RAISED VENT
SYSTEM
ER48D
EH5418 or EHR5418
EH4818 or EHR4818
EH4812 or EHR4812
MH4818, MH4812
DHI542, DHI482,
DHW482
IVS2 or IVSR2
Plus IHL54 or IHL48
NA
ERV48-ER
(must use
remote blower)
ER36D
EH4218 or EHR4218
EH4212 or EHR4212
EH3618 or EHR3618
EH3612 or EHR3612
MH3618, MH3612
DHI421, DHI361
DHW421, DHW361
PHW+PHG36+Color
IVS2 or IVSR2 +
IHL42
IVS1 or IVSR1 +
IHL36
NA
ERV36-ER
(must use
remote blower)
EH3618 or EHR3618
EH3612 or EHR3612
EH3018 or EHR3018
EH3012 or EHR3012
MH3618 or MH3018
MH3612 or MH3012
DHI361
DHW361, DHW301
PHW+PHG36+Color
PHW+PHG30+Color
IVS1 or IVSR1 +
IHL36
IVS1 or IVSR1 +
IHL30
PCOR30 or
PMOR3021
with
ILHSF8 and
ARSC (with
deflector
shield)
ERV30 with
ERD30, ER30DSR
(EGR30 not
approved for use
with downdraft)
(must use
remote blower)
EH5418 or EHR5418
EH4818 or EHR4818
EH4812 or EHR4812
MH4818, MH4812
DHI542, DHI482, DHW482
IVS2 or IVSR2
Plus IHL54 or IHL48
NA
ERV48
(must use
remote blower)
EH4218 or EHR4218
EH4212 or EHR4212
EH3618 or EHR3618
EH3612 or EHR3612
MH3618, MH3612
DHI421, DHI361,
DHW421, DHW361
IVS2 or IVSR2 + IHL42
IVS1 or IVSR1 + IHL36
NA
ERV36
(must use remote
blower)
ER30DSR
ER30D
ERD30
EGR30
ESG486
EG486
ESG366
EG366
SGM466
EH4818 or EHR4818
EH4812 or EHR4812
MH4818, MH4812
DHI482, DHW482
Ventilation Solutions
IVS2 or IVSR2
Plus IHL54 or IHL48
RV46
(CABP3 or remote
blower)
NA
PRV46
(must use remote
blower)
17
Creating the Proper Ventilation System 2
Selecting Cooking Product
COOKING PRODUCT
INTEGRATED VENT
SYSTEM
OVER THE RANGE
(OTR)
MODEL
HOOD
RGC365
SGM365
EH4218 or EHR4218
EH4212 or EHR4212
EH3618 or EHR3618
EH3612 or EHR3612
MH3618 or MH3612
DHI421 or DHI361
DHW421 or DHW361
PHW+PHG36+Color
RGC304
SGM304
EH3618 or EHR3618
EH3612 or EHR3612
EH3018 or EHR3018
EH3012 or EHR3012
MH3618 or MH3612
MH3018 or MH3012
DHI361
DHW361 or DHW301
PHW+PHG36+Color
PHW+PHG30+Color
IVS1 or IVSR1 +
IHL36
or IHL30
METB365-1
ETT365-2
EH4218 or EHR4218
EH4212 or EHR4212
EH3618 or EHR3618
EH3612 or EHR3612
MH3618 or MH3612
DHI421or DHI361
DHW421 or DHW361
PHW+PHG36+Color
IVS2 or IVSR2 +
IHL42
IVS1 or IVSR1 +
IHL36
NA
MET304
ETT304-1
EH3618 or EHR3618
EH3612 or EHR3612
EH3018 or EHR3018
EH3012 or EHR3012
MH3618 or MH3612
MH3018 or MH3012
DHI361
DHW361 or DHW301
PHW+PHG36+Color
PHW+PHG30+Color
IVS1 or IVSR1+
IHL36 or IHL30
PCOR30 or
PMOR3021
(add ILHSF8 &
ARSC if you
want 600 CFM)
MRES30S
EH3618 or EHR3618
EH3612 or EHR3612
EH3018 or EHR3018
EH3012 or EHR3012
MH3618 or MH3612
MH3018 or MH3012
DHI361
DHW361 or DHW301
PHW+PHG36+Color
PHW+PHG30+Color
IVS1 or IVSR1+
IHL36 or IHL30
PCOR30 or
PMOR3021
(add ILHSF8 &
ARSC if you want
600 CFM)
Ventilation Solutions
IVS2 or IVSR2 +
IHL42
IVS1 or IVSR1 +
IHL36
RAISED VENT
SYSTEM
ERV36 or RV36
(with appropriate
remote blower)
NA
PRV36
(must use remote
blower)
PCOR30 or
PMOR3021
(add ILHSF8 &
ARSC if you
want 600 CFM)
ERV30 or RV30
(with appropriate
blower)
PRV30
(must use remote
blower)
ERV36 or RV36
(with appropriate
blower)
PRV36
(must use remote
blower)
ERV30 or RV30
(with appropriate
blower)
PRV30
(must use remote
blower)
ERV30
(must use remote
blower)
PRV30
(must use remote
blower)
18
Creating the Proper Ventilation System 3
Build the Ventilation Package
STEP:
Select
Vent System / Model
VENT SYSTEMS
MODEL
EH4218
EH3618
EH3018
18" Pro Hood
Internal Blower
2
3
Select
Blower
1
EH5418
EH4818
MAX
LENGTH
Included 600
CFM (582 at
0.0” static
pressure)
NA
(one)
8" round
60'
NA
NA
REMP3
REMP16
ILHSF8
ILHSF10
12" Pro Hood
Internal Blower
NA
REMP16
or
ILHSF10
Included 600
CFM (582 at
0.0” static
pressure)
NA
EHR4818
EH3012
EH4812
(two)
8" round
Included
1200 CFM
(1164 at
0.0” static
pressure)
EHR5418
EH3612
NA
NA
REMP3
REMP16
ILHSF8
ILHSF10
EHR3612
EHR3012
12" Pro Hood
EHR4812
Ventilation Solutions
NA
AHT10 may
be used to
transition to
a single 10"
duct exhaust
(one)
8" round
(two)
8" round
AHT10 may
be used to
transition to a
single 10"
duct exhaust
(one)
8" round
(two)
8" round
Included 1200
CFM (1164 at
0.0” static
pressure)
EHR4212
External Blower
DUCT
LENGTH
DUCT SIZE
EHR3018
EH4212
Max Length
for 1 Blower
System
Determine
Duct Length
Incl. Elbows
& Trans.
REMOTE
POWER
EHR3618
18" Pro Hood
5
Duct Size
Needed
(minimum)
INTERNAL
POWER
EHR4218
External Blower
4
REMP16
ILHSF10
AHT10 may be
used to
transition to a
single 10" duct
exhaust
(one)
8" round
(two)
8" round
AHT10 may be
used to
transition to a
single 10" duct
exhaust
COMMENTS
50' for 10"
60' for 8"
Ask builder
about
make-up
air
60'
Only one
blower is
allowed
50' for 10"
60' for 8"
Ask builder
about
make-up air.
Only one
blower is
allowed.
60'
50' for 10"
60' for 8"
Ask builder
about
make-up air
60'
Only one
blower is
allowed
50' for 10"
60' for 8"
Ask builder
about
make-up air.
Only one
blower is
allowed.
19
Creating the Proper Ventilation System 4
Build the Ventilation Package
2
3
Select
Blower
Duct Size
Needed
(minimum)
1
Select
Vent System / Model
VENT SYSTEMS
MODEL
INTERNAL
POWER
REMOTE
POWER
DUCT SIZE
MAX
LENGTH
MH3618
MH3018
Included 600
CFM (582 at
0.0” static
pressure)
NA
(one)
8" round
60'
MH4818
Included
1200 CFM
(1164 at
0.0” static
pressure)
NA
MH3612
MH3012
Included 600
CFM (582 at
0.0” static
pressure)
NA
MH4812
Included
1200 CFM
(1164 at
0.0” static
pressure)
NA
Included
1200 CFM
(1164 at
0.0” static
pressure)
DHI421
DHI361
18" Millennia Wall
Mounted Hood
12" Millennia Wall
Mounted Hood
AHT10 may
be used to
transition to
a single 10"
exhaust
(one)
8" round
50' for 10"
60' for 8"
(two)
8" round
NA
8" round
50'
Included 600
CFM (582 at
0.0” static
pressure)
NA
8" round
60'
DHW482
Included 1200
CFM (1164 at
0.0” static
pressure)
NA
8" round
DHW421
DHW361
DHW301
Included 600
CFM (582 at
0.0” static
pressure)
NA
8" round
PHW +
PHG36
OR
PHG30
Included 600
CFM (582 at
0.0” static
pressure)
NA
8" round
(colored glass)
Ventilation Solutions
5
DUCT
LENGTH
COMMENTS
Ask builder
about
make-up
air
60'
50' for 10"
60' for 8"
Millennia Island Hood
Preference Hood
(two)
8" round
AHT10 may
be used to
transition to
a single 10"
exhaust
DHI602
DHI542
DHI482
Millennia
Chimney Hood
4
Max Length Determine Duct
Length Incl.
for 1 Blower
Elbows & Trans.
System
50'
Ask builder
about
make-up
air
20
Creating the Proper Ventilation System 5
Build the Ventilation Package
STEP:
Select
Vent System / Model
VENT SYSTEMS
3
4
5
6
Select Liner & Transition
Duct Size
Needed
(minimum)
Max
Length
for 1
Blower
System
Determine
Duct Length Incl.
Elbows
& Trans.
DUCT
LENGTH
2
1
Select
Blower
MODEL
INTERNAL
POWER
REMOTE
POWER
LINER
TRANSITION
DUCT SIZE
MAX
LENGTH
IVS1
Included
600 CFM
(582 at
0.0” static
pressure)
NA
IHL36 or IHL30
NA
8" round
60'
IVS2
Included
1200 CFM
(1164 at
0.0” static
pressure)
NA
IHL54, IHL48
IHL42 or IHL40
ATD10
10" round
50'
IVSR1
NA
REMP3
ILHSF8
IHL36 or IHL30
NA
8" round
60'
IVSR2
NA
REMP16
ILHSF10
IHL54, IHL48
IHL42 or IHL40
ATD10
10" round
50'
Ask builder about
make-up air
Included
300
CFM
ILHSF8 &
ARSC
(if used
with
ERD30,
ER30D,
ER30DSR
or EGR30)
40'
Remove
internal
blower if
using the
ILHSF8 &
ARSC
combination
CABP3
REMP3
REMP16
ILHSF8
ILHSF10
40'
Ask builder
about makeup air if unit
is over
1000 CFM
NA
REMP3
REMP16
ILHSF8
ILHSF10
40'
Ask builder
about makeup air if unit
is over
1000 CFM
NA
REMP3
REMP16
ILHSF8
ILHSF10
40'
Ask builder
about makeup air if unit
is over
1000 CFM
PowerPacks
Internal & External
PMOR3021
PCOR30
Over the Range
Microwaves
RV30
NA
NA
NA
3 1/4" x 10"
rectangle
NA
3 1/4" x 10"
rectangle
NA
3 /4" x 10"
rectangle
NA
3 1/4" x 10"
rectangle
COMMENTS
Ask builder about
make-up air
Downdraft RV
Downdraft ERV
ERV48
ERV36
ERV30
ERV48-ER
ERV36-ER
PRV46
PRV36
PRV30
Downdraft PRV
Ventilation Solutions
1
NA
NA
Ventilation Solutions
©Copyright 2009 Dacor, Inc. All rights reserved.
L65348 011509
800.793.0093
www.dacor.com
Download PDF