Dacor | DHICH | Planning Guides | Dacor DHICH Planning Guides

Dacor DHICH Planning Guides
DHI
Document # PG07-002
Revised 10/02/11 Page 1/1
Discovery™ 36”, 42”, 48” and 54” Wide
Ceiling Mount Island Hoods
All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
•
This appliance must be installed in accordance with the
accompanying installation instructions.
•
DO NOT install an additional in-line or external blower to
increase the length of the duct run. Even small differences
between blower air flow rates can greatly reduce the air draw
of the hood.
600 CFM* (1200 CFM* for units with 2 blowers)
with electronic speed control
Blower Speeds
4
Lights
12 Vac, 20 Watt halogen
Filters
Baffle type, dishwasher safe
Exhaust
8 Inch
Finish
15 ¾” (40.0 cm)
28” (71.1 cm) to 36” (91.4 cm)
15 ½”
(39.4 cm)*
12 ½”
(31.8 cm)
warning
•
Blower
30”
(76.2 cm)
36” (91.4 cm) - 42” (106.7 cm)
48” (121.9 cm) - 54” 137.2 cm)
120 Vac, 60 Hz (see table at right for current rating)
Circuit
requirements
12 9/16” (31.9 cm)
Chimney
430 stainless steel
Total connected
load
PLANNING
GUIDE
120 Vac, 15 Amp. grounded, dedicated 3-wire
circuit (hot, neutral, ground)
* 18” 1/4 on models DHI482 and DHI542
* At zero inches static pressure
DHI SERIES overall dimensions
General Specifications
Chimney can accommodate up to 10” round duct work
Model**
Blowers
Lights
Filters
Maximum Current
Draw
DHI361
1
4
1
3.8 Amp.
DHI421
1
4
1
3.8 Amp.
DHI482
2
4
2
6.8 Amp.
DHI542
2
6
2
7.1 Amp.
model specific Specifications
** IMPORTANT ORDERING INFORMATION: Each model
requires that you order a chimney assembly (Part number
DHICH) in addition to the hood assembly part number.
Specifications subject to change without notice.
Maximum Duct Length
The maximum straight duct length for the hood is 50 feet. To determine the
actual maximum duct run, subtract the equivalent length of each elbow,
transition and cap from 50 feet. See the Duct Planning Guide or the
installation instructions for more details.
IMPORTANT: The minimum installed distance from the hood to the cooking
surface must be no less than 30 inches. The minimum specified distance
may be higher for the particular range or cooktop in use. Check the
manufacturers specifications for the cooktop or range.
www.dacor.com
Phone: (800) 793-0093
7.1