2-ROCKER & 3-ROCKER SWITCHES
WARNING
WARNING
ALL ELECTRICAL WORK MUST BE DONE IN
ACCORDANCE WITH LOCAL CODES, ORDINANCES,
OR NATIONAL ELECTRICAL CODE AS APPLICABLE.
FOR SAFETY,THIS PRODUCT MUST BE INSTALLED IN
A GROUNDED SWITCH BOX. IF YOU ARE UNFAMILIAR
WITH METHODS OF INSTALLING ELECTRICAL
WIRING, SECURE THE SERVICES OF A QUALIFIED
ELECTRICIAN.
To prevent serious injury from electrical shock or damage
to electrical components - DO NOT WIRE HOT!
Each individual rocker switch on this control is rated at 15
AMPS, @ 120 VAC. The total load on this control must not
exceed 20 AMPS, @ 120 VAC.
Warranty is void if miswired.
Turn off power and lock out service panel before installing
or wiring this product.
NOTE:
Use this control only with copper or copper-clad wire. Do
not use aluminum wire with this device.
WARNING:
INSTALLATION
If the switch has not been wired properly and wires need
to be moved, proceed as follows:
To avoid fire or electrical shock, turn off power at
circuit breaker or fuse. Test that the power is off
before wiring.
WIRE OPENING
1. Each wire opening has a
release slot.
2. Push a small nail or screwdriver into release slot
while gently removing wire.
1. WARNING
To avoid fire or electrical shock, turn off power at circuit
breaker or fuse. Test that the power is off before wiring.
3. DO NOT pull any wire out
of the switch without using
the release slot.The switch
may become damaged.
2. MOUNT THE SWITCH BOX
For 2-Rocker Switch: Install a 3½" deep single-gang
switch box or a 2" deep double-gang switch box.
For 3-Rocker Switch: Install a 2½" deep double-gang
switch box with a single device adapter plate.
RELEASE SLOT
STEP 4A
3. ATTACH POWER CABLE
SINGLE-GANG
SWITCH BOX
Clamp wiring to switch box and unit using appropriate
clamp. Provide 6" leads inside box and fan for easier
wiring.
4. CONNECT WIRING
General instructions for all configurations:
2 - ROCKER SWITCH
APPLIANCE
RED
LOAD
1
BLACK
LOAD
2
COM
1 2 0 VA C
LINE IN
Make sure both the switch box and the appliance are
properly grounded.
BLACK
Make sure ground wire is securely fastened to control's
ground screw. Tighten ground screw 14 to 16-in. lbs.
torque.
GROUND
WHITE
GRD
WHITE
GROUND
Remove insulation per strip gauge on control (approx.
5/8"). Use proper wire nut sizes for number and size of
wires.
3 - ROCKER SWITCH
For push-in terminals: Use #14-AWG solid copper wire
only.
For screw terminals: Use #12 or #14-AWG solid copper
wire only. Tighten screw terminals 14 to 16-in. lbs. torque.
DOUBLE-GANG SWITCH BOX
(with single device adapter plate)
Choose 4A., 4B. or 4C
COM
4A. When using 2-Rocker or 3-Rocker Switch to turn an
appliance ON & OFF:
120 VAC
LINE IN
Make electrical connections following appropriate
diagram.
BLACK
(over)
WHITE
GROUND
RED
LOAD
1
BLACK
LOAD
2
WHITE
BLACK
GRD
APPLIANCE
WHITE
GROUND
LOAD
3
FIG. I
* 2- SPEED
HOODS
JUMPER
WIRE HERE!
Remove the range hood’s wiring cover. If the hood
has a BLACK JUMPER WIRE, it must be cut and
the end stripped as shown. (FIG. I)
Use UL approved clamps to secure all cables to
hood and box. Make wiring connections following
appropriate diagram. Use proper wire nut sizes for
number and size of wires. Replace range hood wiring cover.
4C. When using a 2-Rocker Switch to turn a range hood
ON & OFF from another location with 120 VAC
POWER CABLE ENTERING HOOD:
Remove the range hood’s wiring cover. If the hood
has a BLACK JUMPER WIRE, it must be cut and
the end stripped as shown. (FIG. I)
** INTERMEDIATE
HOODS
CUT BLACK
CUT BLACK
JUMPER WIRE
HERE!
STEP 4B
REF. FIG 1
* 2- SPEED
HOODS
POWER INTO SWITCH
BLUE
2-ROCKER
SWITCH
RED
WHITE
RED
GROUND
TO
HOOD
BLACK
FROM SWITCH
BOX
WHITE
120 VAC
LINE IN
** INTERMEDIATE
HOODS
Broan-NuTone warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for a period of
one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
RED
GRN
FROM SWITCH
BOX
STEP 4C
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.broan.com 800-558-1711
REF. FIG 1
* 2- SPEED
HOODS
POWER INTO HOOD
BLUE
BLACK
2-ROCKER
SWITCH
RED
WHITE
RED
GROUND
BLACK
WHITE ‡
WHITE‡
BLACK
GROUND
120 VAC
LINE IN
TO SWITCH
BOX
FROM
HOOD
The duration of any implied warranty is limited to the one-year period as specified for the
express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or
telephone number below, (b) give the model number and part identification and (c)
describe the nature of any defect in the product or part. At the time of requesting warranty
service, you must present evidence of the original purchase date.
BLACK
WHITE
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES,
HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL
CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal
maintenance and service or (b) any products or parts which have been subject to misuse,
negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty
installation or installation contrary to recommended installation instructions.
This warranty gives you specific legal rights, and you may also have other rights, which
vary from state to state. This warranty supersedes all prior warranties.
BLUE
BLACK
During this one-year period, Broan-NuTone will, at its option, repair or replace, without
charge, any product or part which is found to be defective under normal use and service.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S
OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR
PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you.
REF. FIG 1
BLACK
6. ATTACH SWITCH PLATE
Fasten the switch plate to the control using the short
screws from the parts bag.
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
GRN
WHITE
5. MOUNT CONTROL IN SWITCH BOX
Tuck wires into switch box and fasten the control to
box using attached screws.
** INTERMEDIATE RANGE HOODS:
Broan 46000 & QT20000 Series. NuTone ACS3 Series.
BLACK
BLACK
Use UL approved clamps to secure all cables to
hood and box. Make wiring connections following
appropriate diagram. Use proper wire nut sizes for
number and size of wires. Replace range hood wiring cover.
* 2-SPEED RANGE HOODS:
Broan 40000, F40000, 41000, 42000, 43000, 52000,
PM250, CBD1, QL1, QML, QS1 & QSE1 Series. NuTone
NS6500, NSPM250, RL6200 & WS1 Series.
BLACK
** INTERMEDIATE
HOODS
REF. FIG 1
BLUE
BLACK
CODE REQUIRES BOTH
ENDS OF THIS WIRE'S
INSULATION TO BE COLORED. USE A PERMANENT MARKER.
‡
RED
BLACK
BLACK
WHITE
WHITE‡
TO SWITCH
BOX
GROUND
120 VAC
LINE IN
99043739D
PK92824-10-00-0E
4B. When using a 2-Rocker Switch to turn a range hood
ON & OFF from another location with 120 VAC
POWER CABLE ENTERING SWITCH BOX: