Enterasys Networks Network Router XSR-3150 Getting Started Guide

Add to my manuals
110 Pages

advertisement

Enterasys Networks Network Router XSR-3150 Getting Started Guide | Manualzz
8.5x11-inch cover with bleed on 4 sides
X-Pedition™ Security Router
XSR-3150 Getting Started Guide
Version 3.0
P/N 9033865-06
Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal
vorgenommen werden.
Notice
Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and
its web site without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such
changes have been made.
The hardware, firmware, or software described in this document is subject to change without notice.
IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR
CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF
OR RELATED TO THIS DOCUMENT, WEB SITE, OR THE INFORMATION CONTAINED IN THEM, EVEN IF
ENTERASYS NETWORKS HAS BEEN ADVISED OF, KNEW OF, OR SHOULD HAVE KNOWN OF, THE POSSIBILITY OF
SUCH DAMAGES.
Enterasys Networks, Inc.
50 Minuteman Road
Andover, MA 01810
© 2007 Enterasys Networks, Inc. All rights reserved.
Part Number: 9033865‐06 September 2007
ENTERASYS, ENTERASYS NETWORKS, ENTERASYS XSR, and any logos associated therewith, are trademarks or registered
trademarks of Enterasys Networks, Inc. in the United States and other countries. All other product names mentioned in this
manual may be trademarks or registered trademarks of their respective owners.
Documentation URL: http://www.enterasys.com/support/manuals
Documentacion URL: http://www.enterasys.com/support/manuals
Dokumentation im Internet: http://www.enterasys.com/support/manuals
i
Regulatory Compliance Information
Federal Communications Commission (FCC) Notice
The XSR complies with Title 47, Part 15, Class A of FCC rules. Operation is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference received, including interference that may cause undesired operation.
NOTE: The XSR has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the XSR is operated in a
commercial environment. This XSR uses, generates, and can radiate radio frequency energy and if not installed in accordance
with the operator’s manual, may cause harmful interference to radio communications. Operation of the XSR in a residential
area is likely to cause interference in which case you will be required to correct the interference at your own expense.
WARNING: Modifications or changes made to the XSR, and not approved by Enterasys Networks may void the authority
granted by the FCC or other such agency to operate the XSR.
The XSR complies with Part 68 of the FCC rules and the requirements adopted by the Administrative Council for Terminal
Attachments (ACTA). A label on the circuit board of the Network Interface Module contains, among other information, a
product identifier in the format listed in the following table. If requested, this number must be provided to the telephone
company.
Product
Product Identifier
NIM-T1/E1-xx, NIM-CT1E1/PRI-xx
US: 5N5DENANET1
NIM-BRI-U-xx
US: 5N5DENANEBU
NIM-ADSL-AC-xx
US: 5N5DL02NEAA
NIM-DIRELAY-xx
US: 5N5DENANEDI
NIM-TE1-xx, NIM-CTE1-PRI-xx
US: 5N5DENANECT
A plug and jack used to connect the XSR to the premises wiring and telephone network must comply with the applicable FCC
Part 68 rules and requirements adopted by ACTA. Refer to the following table and installation instructions for details.
Product
Jack Used
NIM-T1/E1-xx, NIM-CT1E1/PRI-xx, RJ48C
NIM-DIRELAY-xx, NIM-TE1-xx,
NIM-CTE1-PRI-xx
NIM-BRI-U-xx
RJ49C
NIM-ADSL-AC-xx
RJ11C
Codes applicable to this equipment:
Product
Facilities Interface Code (FIC)
Service Order Code (SOC)
NIM-T1/E1-xx, NIM-CT1E1/PRI-xx, 04DU9.BN, 04DU9.DN,
NIM-DIRELAY-xx, NIM-TE1-xx,
04DU9.1KN, 04DU9.1SN
NIM-CTE1-PRI-xx
6.0N
NIM-BRI-U-xx
02IS5
6.0N
NIM-ADSL-AC-xx
02LS2
7.0Y
If the XSR harms the telephone network, the telephone company will notify you in advance that it may need to temporarily
discontinue service. But if advance notice is not practical, the telephone company will notify you as soon as possible. Also, you
will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation
of the XSR. If this happens, the telephone company will provide advance notice for you to make necessary modifications and
maintain uninterrupted service.
If you experience trouble with the XSR, for repair or warranty information, please contact Enterasys Networks, Inc., at 978‐684‐
1000. If the XSR is causing harm to the telephone network, the telephone company may request that you disconnect the
equipment until the problem is solved. The XSR is not intended to be repaired by the customer.
ii
Industry Canada Notices
This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio
Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils
numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des
Communications du Canada.
Equipment Attachments Limitations
“NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets
telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal
Equipment Technical Requirements document(s). The department does not guarantee the equipment will operate to the userʹs
satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local
telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer
should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations
made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request
the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and
internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural
areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric
inspection authority, or electrician, as appropriate.”
“NOTICE: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum
number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any
combination of devices subject only to the requirement that the sum of the ringer equivalence Numbers of all the devices does
not exceed 5.ʺ
R & TTE Directive Declaration
Hereby, Enterasys Networks, Inc. declares that this XSR‐1850 X‐Pedition Security Router is compliant with essential
requirements and other relevant provisions of Directive 1999/5/EC.
Class A ITE Notice
WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the
user may be required to take adequate measures.
Clase A. Aviso de ITE
ADVERTENCIA: Este es un producto de Clase A. En un ambiente doméstico este producto puede causar interferencia de radio
en cuyo caso puede ser requerido tomar medidas adecuadas.
Klasse A ITE Anmerkung
WARNHINWEIS: Dieses Produkt zählt zur Klasse A ( Industriebereich ). In Wohnbereichen kann es hierdurch zu
Funkstörungen kommen, daher sollten angemessene Vorkehrungen zum Schutz getroffen werden.
iii
Product Safety
This product complies with the following: UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950, EN 60825, IEC 60950.
Use the XSR with the Advanced Power Solutions (APS61ES‐30) power supply included with the branch router. Enterasys
Networks strongly recommends that you use only the proper type of power supply cord set for the XSR. It should be a
detachable type, UL listed/CSA certified, type SJ or SJT, rated 250 V minimum, 7 amp with grounding‐type attachment plug.
Maximum length is 15 feet (4.5 meters). The cord set should have the appropriate safety approval for the country in which the
equipment will be installed.
Seguridad del Producto
El producto de Enterasys cumple con lo siguiente: UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950, EN 60825, IEC 60950.
Produktsicherheit
Dieses Produkt entspricht den folgenden Richtlinien: UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950, EN 60825,
IEC 60950.
Electromagnetic Compatibility (EMC)
This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 55024, EN 61000‐3‐2,
EN 61000‐3‐3, AS/NZS CISPR 22, and VCCI V‐3.
Compatibilidad Electromágnetica (EMC)
Este producto de Enterasys cumple con lo siguiente: 47 CFR Partes 2 y 15, CSA C108.8, 89/336/EEC, EN 55022, EN 55024,
EN 61000‐3‐2, EN 61000‐3‐3, AS/NZS CISPR 22, VCCI V‐3.
Elektro- magnetische Kompatibilität ( EMC )
Dieses Produkt entspricht den folgenden Richtlinien: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 55024,
EN 61000‐3‐2, EN 61000‐3‐3, AS/NZS CISPR 22, VCCI V‐3.
Hazardous Substances
This product complies with the requirements of European Directive, 2002/95/EC, Restriction of Hazardous Substances (RoHS)
in Electrical and Electronic Equipment.
European Waste Electrical and Electronic Equipment (WEEE) Notice
In accordance with Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment (WEEE):
1.
The symbol above indicates that separate collection of electrical and electronic equipment is required and that this product
was placed on the European market after August 13, 2005, the date of enforcement for Directive 2002/96/EC.
2.
When this product has reached the end of its serviceable life, it cannot be disposed of as unsorted municipal waste. It must
be collected and treated separately.
3.
It has been determined by the European Parliament that there are potential negative effects on the environment and human
health as a result of the presence of hazardous substances in electrical and electronic equipment.
4.
It is the users’ responsibility to utilize the available collection system to ensure WEEE is properly treated.
For information about the available collection system, please go to www.enterasys.com/services/support/ or contact
Enterasys Customer Support at 353 61 705586 (Ireland).
iv
ѻક䇈ᯢк䰘ӊ
Supplement to Product Instructions
䚼ӊৡ⿄
(Parts)
䞥ሲ䚼ӊ
(Metal Parts)
⬉䏃῵ഫ
(Circuit Modules)
⬉㓚ঞ⬉㓚㒘ӊ
(Cables & Cable Assemblies)
ล᭭੠㘮ড়⠽䚼ӊ
(Plastic and Polymeric parts)
⬉䏃ᓔ݇
(Circuit Breakers)
ƻ˖
䪙
3E
᳝↦᳝ᆇ⠽䋼៪‫ܗ‬㋴(Hazardous Substance)
໮⒈㘨㣃
∲
䬝
݁Ӌ䫀
3%%
+J
&G
&U
h
ƻ
ƻ
h
ƻ
ƻ
h
ƻ
ƻ
h
ƻ
ƻ
h
ƻ
ƻ
h
ƻ
ƻ
ƻ
ƻ
ƻ
ƻ
ƻ
h
ƻ
ƻ
h
h
ƻ
ƻ
໮⒈Ѡ㣃䝮
3%'(
㸼⼎䆹᳝↦᳝ᆇ⠽䋼೼䆹䚼ӊ᠔᳝ഛ䋼ᴤ᭭Ёⱘ৿䞣ഛ೼ SJ/T 11363-2006 ᷛ‫ޚ‬㾘ᅮⱘ䰤䞣㽕∖ҹϟDŽ
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is
below the relevant threshold of the SJ/T 11363-2006 standard.
h˖
㸼⼎䆹᳝↦᳝ᆇ⠽䋼㟇ᇥ೼䆹䚼ӊⱘᶤϔഛ䋼ᴤ᭭Ёⱘ৿䞣䍙ߎSJ/T 11363-2006 ᷛ‫ޚ‬㾘ᅮⱘ䰤䞣㽕∖DŽ
Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T 11363-2006 standard.
ᇍ䫔ଂП᮹ⱘ᠔ଂѻકᴀ㸼ᰒ⼎
߃߯կᑨ䫒ⱘ⬉ᄤֵᙃѻકৃ㛑ࣙ৿䖭ѯ⠽䋼DŽ⊼ᛣ೼᠔ଂѻકЁৃ㛑Ӯгৃ㛑ϡӮ৿᳝᠔᳝᠔߫ⱘ䚼ӊDŽ
This table shows where these substances may be found in the supply chain of Enterasys’ electronic
information products, as of the date of sale of the enclosed product. Note that some of the component types
listed above may or may not be a part of the enclosed product.
䰸䴲঺໪⡍߿ⱘᷛ⊼ℸᷛᖫЎ䩜ᇍ᠔⍝ঞѻકⱘ⦃ֱՓ⫼ᳳᷛᖫᶤѯ䳊䚼ӊӮ
᳝ϔϾϡৠⱘ⦃ֱՓ⫼ᳳ ՟བ⬉∴ऩ‫ܗ‬῵ഫ 䌈೼݊ѻકϞ
ℸ⦃ֱՓ⫼ᳳ䰤া䗖⫼Ѣѻકᰃ೼ѻક᠟‫ݠ‬Ё᠔㾘ᅮⱘᴵӊϟᎹ԰
The Environmentally Friendly Use Period (EFUP) for all enclosed products and their parts
are per the symbol shown here, unless otherwise marked. Certain parts may have a
different EFUP (for example, battery modules) and so are marked to reflect such. The
Environmentally Friendly Use Period is valid only when the product is operated under the
conditions defined in the product manual.
50
v
VCCI Notice
This is a class A product based on the standard of the Voluntary Control Council for Interference by Information Technology
Equipment (VCCI) V‐3. If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble
occurs, the user may be required to take corrective actions.
BSMI EMC Statement — Taiwan
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
Declaration of Conformity
Application of Council Directive(s): 89/336/EEC
73/23/EEC
Manufacturer’s Name: Enterasys Networks, Inc.
Manufacturer’s Address: 50 Minuteman Road
Andover, MA 01810
USA
European Representative Address: Enterasys Networks, Ltd.
Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG14 2PZ, England
Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC
EN 55022
EN 61000‐3‐2
EN 61000‐3‐3
EN 55024
EC Directive 73/23/EEC
EN 60950
EN 60825
Equipment Type/Environment: Networking Equipment, for use in a Commercial
or Light Industrial Environment.
Enterasys Networks, Inc. declares that the equipment packaged with this notice conforms to the above directives.
vi
Australian Telecom
N826
WARNING: Do not install phone line connections during an electrical storm.
WARNING: Do not connect phone line until the interface has been configured through local management. The service
provider may shut off service if an un‐configured interface is connected to the phone lines.
WARNING: The NIM‐BRI‐ST cannot be connected directly to outside lines. An approved channel service unit (CSU) must be
used for connection to the ISDN network. In some areas this CSU is supplied by the network provider and in others it must be
supplied by the user. Contact your service provider for details.
Federal Information Processing Standard (FIPS) Certification
The XSR has been submitted to the National Institute of Standards and Technology (NIST) for FIPS 140‐2 certification and is
now officially listed on the NIST pre‐validation list. For more information about the FIPS validation program, go to http://
csrc.nist.gov/cryptval/preval.htm. For the FIPS 140‐1 and 140‐2 Pre‐Validation List, click on the [PDF] link at the top of the
page.
Independent Communications Authority of South Africa
This product complies with the terms of the provisions of section 54(1) of the Telecommunications Act (Act 103 of 1996) and the
Telecommunications Regulation prescribed under the Post Office Act (Act 44 of 1958).
TE-2002/195
TE-2002/190
APPROVED
APPROVED
TE-2003/112
TE-2003/113
APPROVED
APPROVED
SS/366.01
APPROVED
VPN Consortium Interoperability
The VPN Consortium’s (VPNC) testing program is an important source for certification of conformance to IPSec standards.
With rigorous interoperability testing, the VPNC logo program provides IPSec users even more assurance that the XSR will
interoperate in typical business environments. VPNC is the only major IPSec testing organization that shows both proof of
interoperability as well as the steps taken so that you can reproduce the tests.
vii
Enterasys Networks, Inc. Firmware License Agreement
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,
CAREFULLY READ THIS LICENSE AGREEMENT.
This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc., on behalf of itself
and its Affiliates (as hereinafter defined) (“Enterasys”) that sets forth Your rights and obligations with respect to the Enterasys
software program/firmware (including any accompanying documentation, hardware or media) (“Program”) in the package
and prevails over any additional, conflicting or inconsistent terms and conditions appearing on any purchase order or other
document submitted by You. “Affiliate” means any person, partnership, corporation, limited liability company, other form of
enterprise that directly or indirectly through one or more intermediaries, controls, or is controlled by, or is under common
control with the party specified. This Agreement constitutes the entire understanding between the parties, with respect to the
subject matter of this Agreement. The Program may be contained in firmware, chips or other media.
BY INSTALLING OR OTHERWISE USING THE PROGRAM, YOU REPRESENT THAT YOU ARE AUTHORIZED TO
ACCEPT THESE TERMS ON BEHALF OF THE END USER (IF THE END USER IS AN ENTITY ON WHOSE BEHALF YOU
ARE AUTHORIZED TO ACT, “YOU” AND “YOUR” SHALL BE DEEMED TO REFER TO SUCH ENTITY) AND THAT YOU
AGREE THAT YOU ARE BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES, AMONG OTHER
PROVISIONS, THE LICENSE, THE DISCLAIMER OF WARRANTY AND THE LIMITATION OF LIABILITY. IF YOU DO
NOT AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT,
ENTERASYS IS UNWILLING TO LICENSE THE PROGRAM TO YOU AND YOU AGREE TO RETURN THE UNOPENED
PRODUCT TO ENTERASYS OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT
FOR A FULL REFUND.
IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT ENTERASYS NETWORKS, LEGAL
DEPARTMENT AT (978) 684‐1000.
You and Enterasys agree as follows:
1. LICENSE. You have the non‐exclusive and non‐transferable right to use only the one (1) copy of the Program provided in
this package subject to the terms and conditions of this Agreement.
2. RESTRICTIONS. Except as otherwise authorized in writing by Enterasys, You may not, nor may You permit any third
party to:
(a) Reverse engineer, decompile, disassemble or modify the Program, in whole or in part, including for reasons of error
correction or interoperability, except to the extent expressly permitted by applicable law and to the extent the parties
shall not be permitted by that applicable law, such rights are expressly excluded. Information necessary to achieve
interoperability or correct errors is available from Enterasys upon request and upon payment of Enterasys’ applicable
fee.
(b) Incorporate the Program in whole or in part, in any other product or create derivative works based on the Program, in
whole or in part.
(c) Publish, disclose, copy reproduce or transmit the Program, in whole or in part.
(d) Assign, sell, license, sublicense, rent, lease, encumber by way of security interest, pledge or otherwise transfer the
Program, in whole or in part.
(e) Remove any copyright, trademark, proprietary rights, disclaimer or warning notice included on or embedded in any
part of the Program.
3. APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and federal courts
of the Commonwealth of Massachusetts without regard to its conflicts of laws provisions. You accept the personal jurisdiction
and venue of the Commonwealth of Massachusetts courts. None of the 1980 United Nations Convention on the Limitation
Period in the International Sale of Goods, and the Uniform Computer Information Transactions Act shall apply to this
Agreement.
4. EXPORT RESTRICTIONS. You understand that Enterasys and its Affiliates are subject to regulation by agencies of the
U.S. Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain technical products
to certain countries, unless a license to export the product is obtained from the U.S. Government or an exception from obtaining
such license may be relied upon by the exporting party.
If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export
Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for
civil end uses only and not for military purposes.
viii
If the Program is exported from the United States pursuant to the License Exception TSR under the U.S. Export
Administration Regulations, in addition to the restriction on transfer set forth in Section 1 or 2 of this Agreement, You agree not
to (i) reexport or release the Program, the source code for the Program or technology to a national of a country in Country
Groups D:1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Cambodia, Cuba, Georgia, Iraq, Kazakhstan, Laos, Libya, Macau,
Moldova, Mongolia, North Korea, the People’s Republic of China, Russia, Tajikistan, Turkmenistan, Ukraine, Uzbekistan,
Vietnam, or such other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or
E:2 (as defined herein) the direct product of the Program or the technology, if such foreign produced direct product is subject to
national security controls as identified on the U.S. Commerce Control List, or (iii) if the direct product of the technology is a
complete plant or any major component of a plant, export to Country Groups D:1 or E:2 the direct product of the plant or a
major component thereof, if such foreign produced direct product is subject to national security controls as identified on the
U.S. Commerce Control List or is subject to State Department controls under the U.S. Munitions List.
5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Program (i) was developed solely at private
expense; (ii) contains “restricted computer software” submitted with restricted rights in accordance with section 52.227‐19 (a)
through (d) of the Commercial Computer Software‐Restricted Rights Clause and its successors, and (iii) in all respects is
proprietary data belonging to Enterasys and/or its suppliers. For Department of Defense units, the Program is considered
commercial computer software in accordance with DFARS section 227.7202‐3 and its successors, and use, duplication, or
disclosure by the U.S. Government is subject to restrictions set forth herein.
6. DISCLAIMER OF WARRANTY. EXCEPT FOR THOSE WARRANTIES EXPRESSLY PROVIDED TO YOU IN WRITING
BY ENTERASYS, ENTERASYS DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR
PURPOSE, TITLE AND NON‐INFRINGEMENT WITH RESPECT TO THE PROGRAM. IF IMPLIED WARRANTIES MAY NOT
BE DISCLAIMED BY APPLICABLE LAW, THEN ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THIRTY
(30) DAYS AFTER DELIVERY OF THE PROGRAM TO YOU.
7. LIMITATION OF LIABILITY. IN NO EVENT SHALL ENTERASYS OR ITS SUPPLIERS BE LIABLE FOR ANY
DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS,
BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR
RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THE PROGRAM, EVEN IF
ENTERASYS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THIS FOREGOING LIMITATION SHALL
APPLY REGARDLESS OF THE CAUSE OF ACTION UNDER WHICH DAMAGES ARE SOUGHT.
THE CUMULATIVE LIABILITY OF ENTERASYS TO YOU FOR ALL CLAIMS RELATING TO THE PROGRAM, IN
CONTRACT, TORT OR OTHERWISE, SHALL NOT EXCEED THE TOTAL AMOUNT OF FEES PAID TO ENTERASYS BY
YOU FOR THE RIGHTS GRANTED HEREIN.
8. AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical
value to Enterasys, and, accordingly, You hereby agree to maintain complete books, records and accounts showing (i) license
fees due and paid, and (ii) the use, copying and deployment of the Program. You also grant to Enterasys and its authorized
representatives, upon reasonable notice, the right to audit and examine during Your normal business hours, Your books, records,
accounts and hardware devices upon which the Program may be deployed to verify compliance with this Agreement, including
the verification of the license fees due and paid Enterasys and the use, copying and deployment of the Program. Enterasys’ right
of examination shall be exercised reasonably, in good faith and in a manner calculated to not unreasonably interfere with Your
business. In the event such audit discovers non‐compliance with this Agreement, including copies of the Program made, used
or deployed in breach of this Agreement, You shall promptly pay to Enterasys the appropriate license fees. Enterasys reserves
the right, to be exercised in its sole discretion and without prior notice, to terminate this license, effective immediately, for failure
to comply with this Agreement. Upon any such termination, You shall immediately cease all use of the Program and shall return
to Enterasys the Program and all copies of the Program.
9. OWNERSHIP. This is a license agreement and not an agreement for sale. You acknowledge and agree that the Program
constitutes trade secrets and/or copyrighted material of Enterasys and/or its suppliers. You agree to implement reasonable
security measures to protect such trade secrets and copyrighted material. All right, title and interest in and to the Program shall
remain with Enterasys and/or its suppliers. All rights not specifically granted to You shall be reserved to Enterasys.
10. ENFORCEMENT. You acknowledge and agree that any breach of Sections 2, 4, or 9 of this Agreement by You may cause
Enterasys irreparable damage for which recovery of money damages would be inadequate, and that Enterasys may be entitled
to seek timely injunctive relief to protect Enterasys’ rights under this Agreement in addition to any and all remedies available at
law.
ix
11. ASSIGNMENT. You may not assign, transfer or sublicense this Agreement or any of Your rights or obligations under this
Agreement, except that You may assign this Agreement to any person or entity which acquires substantially all of Your stock
assets. Enterasys may assign this Agreement in its sole discretion. This Agreement shall be binding upon and inure to the benefit
of the parties, their legal representatives, permitted transferees, successors and assigns as permitted by this Agreement. Any
attempted assignment, transfer or sublicense in violation of the terms of this Agreement shall be void and a breach of this
Agreement.
12. WAIVER. A waiver by Enterasys of a breach of any of the terms and conditions of this Agreement must be in writing and
will not be construed as a waiver of any subsequent breach of such term or condition. Enterasys’ failure to enforce a term upon
Your breach of such term shall not be construed as a waiver of Your breach or prevent enforcement on any other occasion.
13. SEVERABILITY. In the event any provision of this Agreement is found to be invalid, illegal or unenforceable, the validity,
legality and enforceability of any of the remaining provisions shall not in any way be affected or impaired thereby, and that
provision shall be reformed, construed and enforced to the maximum extent permissible. Any such invalidity, illegality, or
unenforceability in any jurisdiction shall not invalidate or render illegal or unenforceable such provision in any other
jurisdiction.
14. TERMINATION. Enterasys may terminate this Agreement immediately upon Your breach of any of the terms and
conditions of this Agreement. Upon any such termination, You shall immediately cease all use of the Program and shall return
to Enterasys the Program and all copies of the Program.
x
Contents
About This Guide
Contents of the Guide .......................................................................................................................................xv
Conventions Used in This Guide ......................................................................................................................xv
Getting Help .................................................................................................................................................... xvii
Chapter 1: Overview
System Description ......................................................................................................................................... 1-1
Hardware Features .................................................................................................................................. 1-2
Software Features .................................................................................................................................... 1-4
Operating System ............................................................................................................................... 1-4
Industry-common CLI ......................................................................................................................... 1-4
IP Protocol .......................................................................................................................................... 1-4
IP Routing........................................................................................................................................... 1-5
SNMP and Statistics Gathering .......................................................................................................... 1-5
Security............................................................................................................................................... 1-6
PPP .................................................................................................................................................... 1-6
Frame Relay ....................................................................................................................................... 1-6
Dynamic Host Configuration Protocol (DHCP) ................................................................................... 1-7
Integrated Services Digital Network (ISDN) - BRI/PRI ....................................................................... 1-7
Quality of Service (QoS) ..................................................................................................................... 1-8
Virtual Private Network (VPN) ............................................................................................................ 1-8
GRE over IPSec ................................................................................................................................. 1-9
Asynchronous Digital Subscriber Line (ADSL) ................................................................................. 1-10
Dial Service ...................................................................................................................................... 1-10
Dial Backup ...................................................................................................................................... 1-10
Dial-on-Demand/Bandwidth-on-Demand (DoD/BoD) ....................................................................... 1-10
Installation Overview .................................................................................................................................... 1-11
Chapter 2: Hardware Installation
Introduction ..................................................................................................................................................... 2-1
Verifying Your Shipment ................................................................................................................................. 2-1
Installation Site Suggestions .......................................................................................................................... 2-1
Installing NIM Cards and Rack Mounting ....................................................................................................... 2-2
Installing a CompactFlash Memory Card ....................................................................................................... 2-5
CompactFlash Card Installation ............................................................................................................... 2-5
CompactFlash Card for the ADSL NIM .................................................................................................... 2-6
Formatting the CompactFlash Card ......................................................................................................... 2-6
Connecting Cables ......................................................................................................................................... 2-7
Chapter 3: Software Configuration
Initializing XSR Software ................................................................................................................................ 3-1
Opening a COM (Console) Session ............................................................................................................... 3-3
Optional: Configuring Remote Auto Install ..................................................................................................... 3-3
Configuring RAI for Frame Relay ............................................................................................................. 3-3
Configuring RAI for DHCP over LAN ....................................................................................................... 3-5
Configuring RAI over ADSL ..................................................................................................................... 3-5
Configuring the XSR Name and User Information .......................................................................................... 3-7
Setting User Name, Privilege and Password ........................................................................................... 3-7
Setting the Clock ............................................................................................................................................ 3-7
Configuring the LAN Ports .............................................................................................................................. 3-8
Configuring the WAN Ports ............................................................................................................................ 3-8
xi
PRI Configuration ..................................................................................................................................... 3-8
BRI Configuration ..................................................................................................................................... 3-9
BRI Leased Line ................................................................................................................................. 3-9
BRI Leased Frame Relay ................................................................................................................. 3-10
BRI Switched Line ............................................................................................................................ 3-10
ADSL Configuration ............................................................................................................................... 3-11
PPPoE .............................................................................................................................................. 3-11
PPPoA .............................................................................................................................................. 3-11
IPoA.................................................................................................................................................. 3-12
Firewall Sample Configuration ...................................................................................................................... 3-12
Setting Up RIP Routing ................................................................................................................................ 3-14
Configure OSPF Routing .............................................................................................................................. 3-15
Configuring Frame Relay Point to Point Networks ....................................................................................... 3-15
Setting Up an SNMP Community String, Traps and V3 Values ................................................................... 3-16
Configuring Message Logging and Severity Level ....................................................................................... 3-17
Viewing Your Configuration .......................................................................................................................... 3-18
Connecting Remotely via the Web ............................................................................................................... 3-18
LAN-PPP Services Sample Configuration .................................................................................................... 3-20
Frame Relay WAN Link with PPP Backup Sample Configuration ................................................................ 3-22
Configure Users and Passwords ...................................................................................................... 3-22
Configure LAN Interface ................................................................................................................... 3-22
Configure Quality of Service ............................................................................................................. 3-22
Configure WAN/Frame Relay Port ................................................................................................... 3-23
Apply QoS ........................................................................................................................................ 3-24
Configure OSPF Routing.................................................................................................................. 3-25
Configure More Access Lists ............................................................................................................ 3-25
Configure DHCP/BOOTP Relay ....................................................................................................... 3-25
Configure the Dial Backup Connection............................................................................................. 3-25
Configure SNMP............................................................................................................................... 3-26
VPN Site-to-Site Sample Configuration ........................................................................................................ 3-27
Generate Master Encryption Key ..................................................................................................... 3-27
Configure Access Control Lists ........................................................................................................ 3-27
Set Up IKE Phase I Security............................................................................................................. 3-28
Configure IKE Policy for Remote Peer ............................................................................................. 3-28
Create a Transform Set .................................................................................................................... 3-28
Configure Crypto Maps..................................................................................................................... 3-28
Configuring VPN at Interface Mode and Setting Up RIP .................................................................. 3-29
Configuring Authentication (AAA)..................................................................................................... 3-30
VPN Sample Configuration with Network Extension Mode .......................................................................... 3-30
XSR Rebooting Characteristics .................................................................................................................... 3-33
Initialization Output ................................................................................................................................. 3-33
Reboot Triggers ..................................................................................................................................... 3-34
Power-Up Reboot ............................................................................................................................. 3-34
Reload Command from the CLI........................................................................................................ 3-35
Bootrom Monitor Commands bc and bw .......................................................................................... 3-35
Watchdog Timer Expiration .............................................................................................................. 3-35
System Crash ................................................................................................................................... 3-35
Restart with Default Configuration Interrupt ..................................................................................... 3-35
Power-up Error Conditions ..................................................................................................................... 3-35
Bootrom Monitor Mode Commands .............................................................................................................. 3-35
bc ........................................................................................................................................................... 3-36
bw ........................................................................................................................................................... 3-36
bp ........................................................................................................................................................... 3-36
bu ........................................................................................................................................................... 3-36
xii
bU ........................................................................................................................................................... 3-37
cd ........................................................................................................................................................... 3-37
da ........................................................................................................................................................... 3-37
df ............................................................................................................................................................ 3-38
del .......................................................................................................................................................... 3-38
dir ........................................................................................................................................................... 3-38
ds ........................................................................................................................................................... 3-38
dt ............................................................................................................................................................ 3-38
ff ............................................................................................................................................................. 3-38
ffc ........................................................................................................................................................... 3-39
ng ........................................................................................................................................................... 3-39
np ........................................................................................................................................................... 3-39
ns ........................................................................................................................................................... 3-39
remove ................................................................................................................................................... 3-40
rename ................................................................................................................................................... 3-40
sb ........................................................................................................................................................... 3-40
sf ............................................................................................................................................................ 3-40
si ............................................................................................................................................................. 3-41
sn ........................................................................................................................................................... 3-41
sv ............................................................................................................................................................ 3-42
Appendix A: Specifications
System Specifications ....................................................................................................................................A-1
Cable, CompactFlash and Accessory Specifications .....................................................................................A-2
COM (Console) Port .................................................................................................................................A-4
GigabitEthernet Ports ...............................................................................................................................A-5
Mini-GBIC Fiber, Copper Port ..................................................................................................................A-5
Copper/Fiber-optic Ethernet NIMs ...........................................................................................................A-6
2/4-Port Serial NIM Card Port ..................................................................................................................A-7
T1/E1/ISDN PRI NIM Card Ports ...........................................................................................................A-12
Balun for E1 or PRI NIM Cards ..............................................................................................................A-13
Grounding Shunt for E1 NIM Cards .......................................................................................................A-14
Installing Shunt/Terminal Strip..........................................................................................................A-14
T3/E3 NIM Card .....................................................................................................................................A-15
1/2-Port BRI-S/T ISDB NIM Card Ports .................................................................................................A-16
Termination Shunt for the ISDN BRI-S/T NIM Card ...............................................................................A-16
Installing Shunt/Terminal Strip..........................................................................................................A-17
1/2-Port BRI-U NIM Card Ports ..............................................................................................................A-18
1-Port ADSL NIM Card Port ...................................................................................................................A-19
T1/E1 Drop & Insert (D&I) NIM ..............................................................................................................A-20
CompactFlash Memory Card .................................................................................................................A-21
LED Behavior .........................................................................................................................................A-21
Index
xiii
xiv
About This Guide
This guide provides a general overview of the XSR‐3150 hardware and software features and
describes how to quickly install and configure the XSR. Refer to the XSR CLI Reference Guide and
XSR User’s Guide for information not contained in this document.
This guide is written for administrators who want to configure the X‐Pedition Security Router or
experienced users who are knowledgeable of basic networking principles.
This chapter details the following:
•
Contents of the Guide
•
Conventions Used in This Guide
•
Getting Help
Contents of the Guide
Information in this guide is arranged as follows:
•
Chapter 1, Overview, introduces key features of the XSR and briefly describes hardware
installation.
•
Chapter 2, Hardware Installation, provides a checklist to verify your shipment and describes
how to install XSR hardware including NIM and optional CompactFlash cards, and rack‐
mounting brackets.
•
Chapter 3, Software Configuration, describes how to initiate and quickly configure the XSR. It
also details how to add an interface and subnet mask; set passwords, SNMP, DNS and
SYSLOG server values; configure the firewall feature set, upgrade system image and Boot
PROM software; consult system statistics, and save configuration changes.
•
Appendix A, Specifications, outlines hardware specifications including information about: the
processor, interfaces, system memory, chassis, power supply, interfaces, required cabling and
other accessories, pinout assignments for WAN and LAN interfaces, and LED behavior.
Conventions Used in This Guide
The following conventions are used in this guide:
Note: Calls the reader’s attention to any item of information that may be of special importance.
Nota: Llama la atencion del lector a cierta información que puede ser de especial importancia.
Caution: Contains information essential to avoid damage to the equipment.
Precaución: Contiene información esencial para prevenir dañar el equipo.
Achtung: Verweißt auf wichtige Informationen zum Schutz gegen Beschädigungen.
xv
Electrical Hazard: Warns against an action that could result in personal injury or death due to an
electrical hazard.
Riesgo Electrico: Advierte contra una acción que pudiera resultar en lesión corporal o la muerte
debido a un riesgo eléctrico.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes.
Personal vorgenommen werden.
Warning: Warns against an action that could result in personal injury or death.
Advertencia: Advierte contra una acción que pudiera resultar en lesión corporal o la muerte.
Warnhinweis: Warnung vor Handlungen, die zu Verletzung von Personen oder gar Todesfällen
führen können!
xvi
Bold/En negrilla
Text in boldface indicates values you type using the keyboard or select
using the mouse (for example, a:\setup). Default settings may also appear
in bold.
El texto en negrilla indica valores que usted introduce con el teclado o que
selecciona con el mouse (por ejemplo, a:\setup). Las configuraciones
default pueden también aparecer en en negrilla.
Italics/It áli ca
Text in italics indicates a variable, important new term, or the title of a
manual.
El texto en itálica indica un valor variable, un importante nuevo término, o
el título de un manual.
SMALL CAPS/
MAYUSCULAS
Small caps specify the keys to press on the keyboard; a plus sign (+)
between keys indicates that you must press the keys simultaneously (for
example, CTRL+ALT+DEL).
Las mayusculas indican las teclas a oprimir en el teclado; un signo de más
(+) entre las teclas indica que usted debe presionar las teclas
simultáneamente (por ejemplo, CTRL+ALT+DEL).
Courier font/
Tipo de letra Courier
Text in this font denotes a file name or directory.
El texto en este tipo de letra denota un nombre de archivo o de directorio.
+
Points to text describing CLI command.
Apunta al texto que describe un comando de CLI.
FastEthernet
FastEthernet and GigabitEthernet references are generally
interchangeable throughout this guide.
Las referencias a los terminos FastEthernet y GigabitEthernet son
generalmente intercambiables en el contenido de esta guia.
Getting Help
For additional support related to the XSR, contact Enterasys Networks using one of the following
methods:
World Wide Web
www.enterasys.com/support/
Phone
1-800-872-8440 (toll-free in U.S. and Canada)
or 1-978-684-1000
To find the Enterasys Networks Support toll-free number in your country:
www.enterasys.com/support/
Internet mail
[email protected]
To expedite your message, type [xsr] in the subject line.
FTP
Login
Password
ftp://ftp.enterasys.com
Get the latest image and
Release Notes
http://www.enterasys.com/download
Additional documentation
http://www.enterasys.com/support/manuals
anonymous
your Email address
To send comments concerning this document to the Technical Publications Department:
[email protected]
Please include the document Part Number in your email message.
Before contacting Enterasys Networks for technical support, have the following information
ready:
•
Your Enterasys Networks service contract number
•
A description of the failure
•
A description of any action(s) already taken to resolve the problem (for example, changing
mode switches or rebooting the unit)
•
The serial and revision numbers of any associated Enterasys Networks products in the
network
•
A description of your network environment (such as layout, cable type, other relevant
environmental information)
•
Network load and frame size at the time of the problem
•
The device history (for example, if you have returned the device before, or if this a recurring
problem)
•
Any previous Return Material Authorization (RMA) numbers
xvii
xviii
1
Overview
This chapter introduces the key features of the XSR-3150 and briefly describes hardware
installation.
System Description
The XSR is a networking device designed for enterprise regional offices that provides IP routing
over GigabitEthernet LAN and T1/E1, Serial (RS232, X.21, V.35, RS422/530, RS449), Dial Services
via POTS, ISDN (BRI/PRI) or Frame Relay WAN connections. Virtual Private Network (VPN)
support is also provided in Site-to-Site or Remote Access applications.
The router can be managed using the Command Line Interface (CLI) and monitored using SNMP
v1, v2c/v3 (with standard MIB-II and proprietary MIB support). The XSR also provides Web
access to display device data.
The XSR-3150 can be configured to support the following applications:
•
Regional Router - The XSR serves as a router with multiple WAN link support. It is also capable
of providing the same VPN support as the full-featured VPN Gateway for customers who
wish to integrate both applications in the same system.
•
Full-Featured VPN Gateway - The XSR supports more than 5000 simultaneous VPN tunnels at
300 Mbps using 3DE. The VPN Gateway supports the same functionality as the Aurorean
Network Gateway series but without local hard disk support.
•
Firewall platform - The XSR provides a stateful inspection firewall. Processing is performed on
the dual MIPS core at 300 Mbps.
A typical deployment of the XSR might be in two branch offices connected to a regional office, as
illustrated in Figure 1-1. In this example, one XSR with its associated sub-network has an E1/T1 or
high-speed serial WAN connection as its primary link to the Public Service Telephone Network
(PSTN) with an asynchronous modem connection in a backup capacity.
XSR Getting Started Guide
1-1
System Description
Figure 1-1
Typical XSR-3150 Topology
XSR-3150
XSR
XSR
Hardware Features
The semi-modular XSR, shown in Figure 1-2, comes equipped with the following features:
1-2
Overview
•
Standard 1U chassis (1-11/16 inches high by 17 inches wide by 21 inches deep) mountable in a
standard 19” rack.
•
Broadcom 1250 dual-CPU, 64-bit processor (1700 Dhrystone MIPS @ 600 MHz) with load
balancing, 512 KByte on-chip Layer 2 cache, up to two co-issued, load-to-use instruction pairs
per cycle, and 32 KByte Instruction and Data caches.
•
Two, internal, universal (100 - 240 VAC) redundant power supplies with country-specific line
cords.
System Description
Figure 1-2
XSR-3150
SE
CU
XS
R
RITY
RO
-31
UT
ER
S
50
NIM
1
NIM
2
NIM
1
NIM
SY
PW
S
2
VP
N
R
CO
M
CO
M
Lin
k
10
00
TX
10
/10
0/1
00
GB
IC
0
10
/10
ET
H1
ET
H2
•
0/1
00
0
ET
H3
Two Network Interface Module (NIM) card slots for these NIMs:
–
1, 2, or 4 full, fractional and channelized T1/E1 WAN NIM with integral CSU/DSU or
Primary Rate Interface (PRI) ports (RJ-48C).
–
1-port T3/E3 channelized/unchannelized WAN NIM with BNC ports. This NIM is also
available with up to 16 T1/E1 tributaries and system synchronizaton of two MIMs.
–
High-speed serial port for up to 230 Kbps asynchronous and 8 Mbps synchronous for
leased and dial lines (68-pin serial) with universal connector supporting X.21, V.35, RS422
and EIA530.
–
1- or 2-port serial Basic Rate Interface (BRI) WAN NIMs with S/T (RJ-45) or U ports (RJ49C).
–
1-port Annex A (POTS)/C or B (ISDN) ADSL WAN NIMs with RJ-11 connector with
CompactFlash card.
–
2-port T1/E1 Drop and Insert WAN NIM with RJ-45 connectors.
–
1-port Copper or Fiber-optic Ethernet LAN or WAN NIM with an RJ-45 or MT-RJ multimode interface.
•
Three 10/100/1000BaseT GigabitEthernet LAN connectors and a Mini-Gigabit Interface
Converter (MGBIC) fiberoptic port capable of operating in full or half-duplex modes.
•
COM (console) serial interface including modem control signals for remote debugging, or outof-band configuration.
•
128 MBytes of 64-bit, 133 MHz SDRAM/DIMM memory, 8 MBytes of Onboard Flash RAM,
optional 16 MByte plug-in CompactFlash RAM card upgradeable to 1 GByte for firmware,
image and alarm storage.
•
PCI-based, Encryption Module hardware accelerator for: encryption/decryption (3DES),
Message Digest (MD-5, SHA-1), and public key acceleration.
•
Alarm detection, local and remote loopback, and loopback tests.
XSR Getting Started Guide
1-3
System Description
•
14 diagnostic LEDs to display port and system status as well as indicate a Flash upgrade in
progress.
•
Five system fans with failure detection capability and three in-board fans dedicated to power
supply cooling.
Software Features
The XSR provides the following software features:
Operating System
•
Multi-threaded OS to fully utilize the XSR’s dual processors
Industry-common CLI
•
Configuration, performance (status/statistics), and fault (traps/events) management
•
Multiple administrators can log into the XSR simultaneously through terminal or remote
Telnet/SSHv2 access
•
Maximum of five simultaneous Telnet/SSHv2 sessions
•
CLI script downloads for bulk configuration
•
Alarm/event view and retrieval
•
Diagnostic/debug reports and statistics
•
Multiple user privilege settings per configuration mode
IP Protocol
1-4
Overview
•
Address Resolution Protocol (ARP)
•
Internet Control Message Protocol (ICMP}
•
Transmission Control Protocol/User Datagram Protocol (TCP/UDP)
•
Dynamic Host Configuration Protocol (DHCP)
•
Network Address Translation (NAT) & NAPT
•
Dynamic NAT pool based on source and destination
•
Dynamic NAT pool with overload
•
NAT Port Forwarding
•
PAT (NAPT) based on port source and destination
•
Telnet & TFTP for device management and configuration
•
Debugging tools Ping & TraceRoute
•
Secondary IP addressing
•
PPP and OSPF debugging
•
Internet Group Management Protocol (IGMP)
•
Remote Auto Install over Ethernet
System Description
•
Simple Network Time Protocol (SNTP) server
•
OS fallback
IP Routing
•
Static and multiple routes to the same destination
•
Redistribution of routes from RIP, OSPF, BGP, connected, or static into RIP, OSPF, and BGP
•
RIP-1 & RIP-2
•
Open Shortest Path First Protocol (OSPF)
•
OSPF over Generic Routing Encapsulation (GRE): RFC-2784
•
Virtual Router Redundancy Protocol (VRRP)
•
Configurable administrative distance (route preference) per protocol for RIP, OSPF and BGP,
and per route for static routes
•
DNS Proxy (forwarding proxy server)
•
Virtual Local Area Networks (VLAN) IEEE 802.1Q
•
VLAN Routing including priority support
•
Policy Based Routing
•
Border Gateway Protocol Version 4 (BGP-4)
•
BGP configurable timers and filter tags
•
Protocol Independent Multicast - Sparse Mode (PIM-SM)
•
Multicast Forwarding over GRE
•
Equal-Cost Multi-Path Protocol (ECMP)
SNMP and Statistics Gathering
•
Gathering XSR statistics and monitoring using SNMP v1/v2c/v3 using proprietary and
standard MIBs including MIB-II Syslog, Configuration Change, TimedReset, Entity, Chassis,
Persistence, and Protocol MIBs (OSPF, RIP, FR, and PPP).
•
Up/download files to the XSR with the Configuration Management MIB.
•
Configure and monitor the XSR using proprietary MIBs: Enterprise VPN and Firewall
Configuration, and Host Resources (CPU utilization) via NetSight Atlas Router Services
Manager.
•
Configuration checksum via MIB
•
SNMP Inform support
•
Service Level Agreement (SLA) agents
•
SNMP-TFTP on-the-fly running configuration
•
Hostname in the Syslog message header
•
Multiple Syslog servers
XSR Getting Started Guide
1-5
System Description
Security
•
Stateful inspection firewall engine
•
FTP, H.323, and RPC (SUN and Microsoft) ALG support
•
Application commands for FTP, SMTP, & HTTP
•
Firewall logging and authentication
•
Firewall interaction with NAT & VPN
•
Standard and Extended Access Control Lists
•
Denial of Service (DoS) protection
•
AAA for firewall, Console, Telnet, SSHv2, PPP and VPN users
•
AAA per-interface configuration
•
AAA debugging
•
Dynamic Firewall configuration
•
Onboard URL filtering
•
Sync and asynchronous communications modes accepted
•
Authentication of peer entities via Password Authentication Protocol (PAP)
•
Challenge Handshake Authentication Protocol (CHAP)
•
Microsoft Challenge Handshake Authentication Protocol (MS-CHAP)
•
IP Address can be assigned from remote device, and the device will support IP address
assignment to a remote device. Pools can be configured locally or from a separate server
(DHCP).
•
Multilink PPP (MLPPP): RFC-1990
•
Multi-Class MLPPP: RFC-2686
•
Point-to-Point Protocol over Ethernet (PPPoE) and sub-interface monitoring
•
Remote Auto Install over PPP
PPP
Frame Relay
•
DTE support for User Network Interface (UNI) over Frame Relay PVC connections
•
10-bit DLCI addressing using a 2-byte DLCI header
•
Per DLCI IP QoS support
•
Rate enforcement (CIR) with automatic rate fallback via traffic/adaptive shaping when the
network is congested. Automatically restores normal rates when congestion removed
•
Congestion control: Backward and Forward Explicit Congestion Notification (BECN/FECN)
•
Standard LMIs: ILMI, ANSI Annex D, CCITT Annex A and:
• Auto option for LMI detection/adaptation
• None option for directly connecting XSRs
1-6
Overview
System Description
•
Periodic Keep-Alive messages to learn of connection problems
•
Multi-protocol interconnect over Frame Relay - RFC-2427
•
RFC-2390 Frame Relay Inverse ARP to discover IP address of remote peer when used in multipoint mode and responds to incoming Inverse ARP requests independent of P2P or MP2P
•
Multiple logical interfaces over the same physical Frame Relay port: sub-interfaces
•
Quality of Service: standard FIFO queuing, or IP QoS on DLCIs.
•
Max PDU size of 1600 bytes
•
Traffic shaping
•
Frame Relay Fragmentation Implementation Agreement (FRF.12)
•
Data Communications Equipment (DCE) support
•
Frame Relay over ISDN
•
Remote Auto Install over Frame Relay
Dynamic Host Configuration Protocol (DHCP)
•
Temporary or permanent network (IP) address allocation to clients
•
Network configuration parameter assignment to clients
•
Persistent storage/database of network values for network clients - Bindings Database
•
Persistent storage of network client lease states kept across reboot
•
Persistent and user-controllable conflict avoidance to prevent duplicate IP address including
configurable ping checking
•
Visibility of DHCP network activity and leases through operator reports statistics and logs
•
DHCP Client
Integrated Services Digital Network (ISDN) - BRI/PRI
•
Circuit Mode Data (CMD): Channels (DS0s) are switched by the CO to the destination user for
the duration of the call
•
Outgoing calls supported for Backup, DoD/BoD
•
Incoming calls routed to the correct protocol stack based on called number/sub-address and
calling number/sub-address
•
Permanent B-channel support, i.e. 64 or 128 kbps lease line. Each BRI port can be set for CMD
or Leased-Line mode of operation
•
BRI supported switches: ETSI
•
BRI: TEI auto-negotiated
•
Q.921/Q.931 (Layer 2/Layer 3) configuration is set automatically by selection of switch type
•
PRI supported switches: ETSI, NI, DMS100, NTT
•
PRI: Handling restart and maintenance modes automatically set
•
PRI: Fixed TEI to 0
•
ISDN switched and Leased Line connections
XSR Getting Started Guide
1-7
System Description
•
Bandwidth optimization (BoD) & Dial on Demand (DoD)
•
Bandwidth Allocation Protocol (BAP)
•
Security: PAP/CHAP
•
Call monitoring
•
Multilink PPP (MLPPP)
•
Per call activation for NTT switches
•
Frame Relay over ISDN
Quality of Service (QoS)
•
Traffic classification using IP Precedence and DiffServ Code Point (DSCP) bits, and multiplefield (L3, L4 and other headers) inspection. Match-any and match-all options also define a classmap.
•
Priority Queuing or Class-based Weight Fair Queueing (CBWFQ) to specify the policy-map
•
Random and Weighted Early Detection (RED/WRED) and Tail Drop congestion avoidance
•
QoS over VPN
•
QoS on Input
Virtual Private Network (VPN)
•
Site-to-Site application
• 200 tunnels with standard 64-Mbyte DIMM
• IPSec/IKE with pre-shared secrets
• IPSec/IKE with Certificates (PKI)
• EZ-IPsec with PKI or pre-shared secrets:
• Network Extension Mode (NEM)
• Client mode
•
Remote Access application
• 200 tunnels with standard 64-Mbyte DIMM installed
• L2TP/IPSec protocols
–
Certificate and PKI environment
MS-ChapV2, EAP user authentication:
Username/Password (local database & RADIUS)
SecurID (third-party plug-in)
Certificates (embedded/smart cards) – Microsoft only
–
PPTP protocol
MS-ChapV2, EAP user authentication
Local Database & RADIUS
SecurID (third-party plug-in)
1-8
Overview
System Description
Certificates (embedded/smart cards) – Microsoft only
•
Encryption
• Advanced Encryption Standard (AES), Triple Data Encryption Standard (3DES), Data
Encryption Standard (DES)
• 3DES/DES acceleration
•
Data Integrity
• MD5 & SHA-1 algorithms
•
Internet Protocol Security (IPsec)
• Encapsulating Security Payload (ESP), Authentication Header (AH) & IPComp
• Tunnel & Transport mode
• Diffie-Hellman Groups 1 & 2
• Mode Config for IP address assignment
• NAT Traversal via UDP encapsulation
•
Public Key Infrastructure (PKI)
• Microsoft, Verisign Certificate Authority (CA) support
• Simple Certificate Enrollment Protocol (SCEP)
• Chained CA support
• CRL checking (Hypertext Transfer Protocol [HTTP] & Lightweight Directory Access
Protocol (LDAP)
•
Network Address Translation (NAT)
• Static NAT, on the interface and port-forwarded static NAT
• PAT (NAPT) by port source and destination address
• Dynamic NAT by source/destination IP address
• Dynamic NAT pool mapping with overload
• PPTP/GRE ALG and arbitrary IP address for NAPT
• Multiple NATs on an interface
•
Dynamic Host Configuration Protocol (DHCP)
• DHCP Server
•
OSPF over VPN
•
DF Bit override
GRE over IPSec
•
ToS bit preservation
•
IP helper on VPN interfaces
•
IETF/Microsoft-compatible NAT traversal for L2TP
•
QoS over VPN
XSR Getting Started Guide
1-9
System Description
Asynchronous Digital Subscriber Line (ADSL)
•
POTS and ISDN circuit support
•
ATM Frame UNI (FUNI) data framing format
•
OAM cells: AIS, RDI, CC, Loopback over F4 and F5 flows
•
Up to 30 ATM Permanent Virtual Circuits (PVCs)
•
ATM UBR traffic class
•
ATM Adaption Layers 0, 5
•
PDU encapsulation types:
• PPP over ATM (PPPoA) (routed)
• IP over ATM (routed)
• PPP over Ethernet over ATM (PPPoE) (routed)
•
Responds to inverse ARP requests
•
Maintenance of SNMP Interface and Interface Stack tables
•
Remote Auto Install over ADSL
Dial Service
•
Asynchronous serial support through an external modem
•
Synchronous serial
•
Outbound calling
•
Unnumbered Interface Addressing
•
PPP encapsulation
•
Authentication from XSR’s database for PAP & CHAP
•
Dialer profile support
•
Configurable redialer
•
ISDN callback
•
Dialer watch
•
Dialer interface spoofing
•
Incoming call support for analog modems
Dial Backup
•
IP Interfaces backup
Dial-on-Demand/Bandwidth-on-Demand (DoD/BoD)
1-10
Overview
•
PPP Point-to-Multipoint & Multi-to-Multipoint connections
•
MLPPP Point -to-Multipoint & Multi-to-Multipoint connections
•
Incoming Call Mapping connections
Installation Overview
•
Switched PPP Multilink connections
•
Backup using ISDN & MLPPP connections
•
Dialer interface spoofing
•
Dialer watch
Installation Overview
Installing the XSR consists of performing the following general steps. For detailed instructions,
refer to Chapters 2 and 3 of this manual.
1
Unpack the XSR from the shipping box. Remove accessories.
Items included in the shipping box are shown in Chapter 2 of this manual. If you are missing
any of these items, contact your authorized Enterasys Networks reseller or Enterasys
Networks Customer Support as described in the XSR Quick Start Guide.
Cabling is not supplied with the XSR. Refer to page A-2 for part numbers and contact your
Enterasys Networks sales representative.
2
Install any optional memory component.
3
Install NIM cards.
4
Mount the XSR in a standard 19” rack.
5
Connect Ethernet cable(s) to the GigabitEthernet LAN port(s).
6
Do one of the following or both:
–
Connect a NIM cable, attaching one end to the RJ-xx, BNC or optical port on the XSR and
the other to a network connector/hub.
–
Connect the serial cable to the High Speed serial port, attaching one end to the 68-pin,
SCSI III type connector on the XSR and the other end to a network device.
–
Connect all other NIM cables.
7
Connect the COM serial cable, attaching the female end to the COM port of the XSR and the
other end to the DB-9 serial port on your terminal or PC.
8
Connect the appropriate end of the country-specific power cords to the AC Inlet/ Switches at
the back of the XSR and plug the other ends into a wall socket.
Once the XSR is connected, you can begin software configuration, which is described in “Software
Configuration” on page 3-1.
XSR Getting Started Guide
1-11
Installation Overview
1-12
Overview
2
Hardware Installation
Introduction
This chapter provides a checklist to verify your shipment, suggestions for the installation site, and
describes how to install the following XSR hardware:
•
NIM cards
•
Optional - CompactFlash card
•
Connecting cables
Note: For instructions on installing a balun and grounding shunt/terminal strip on E1 NIM cards only,
refer to Appendix A: Specifications on page A-1.
Verifying Your Shipment
Before installing the XSR, first check your shipment to ensure that everything you ordered arrived
safely. Open the shipping box(es) and verify that you received the following equipment:
•
XSR chassis with installed hardware including any optional NIM cards (shipped separately)
•
Two country-specific power cables
•
One console (COM) cable
•
Rack mount assembly
•
Quick Start Guide
Installation Site Suggestions
When determining an installation site for the XSR chassis, follow the guidelines outlined below:
•
For proper cooling, maintain a minimum clearance of 15.2 centimeters (6 inches) behind the
chassis and 5.08 centimeters (2 inches) of clearance on either side of the chassis.
•
If installing the XSR chassis as a free-standing unit on a shelf, ensure that the shelf can support
a minimum weight of approximately 20 pounds per fully loaded chassis plus the weight of the
connected network cables.
•
For access to the rear of the chassis, allow an area of 48.26 centimeters (19 inches) wide by 61
centimeters (24 inches) deep.
•
If installing the XSR chassis in an equipment rack, ensure that the rack can support and
remain stable with the chassis installed.
XSR Getting Started Guide
2-1
Installing NIM Cards and Rack Mounting
•
Each XSR AC power supply requires a three-pronged power receptacle capable of delivering
the current and voltage specified in Appendix A. An AC outlet on a separately fused circuit is
required for each XSR to provide power redundancy, and must be located within 182
centimeters (6 feet) from the site. The power cord used and type of outlet is dependent on the
country. In the United States, a power cord with a NEMA 5-15P plug is provided with each
XSR.
•
Ambient temperature at the installation site must be maintained between 0° and 40°C (41° to
104°F). Temperature changes must be maintained within 10°C (18°F) per hour.
Installing NIM Cards and Rack Mounting
Perform the following steps to install optional NIM card(s) and rack mount the XSR:
1.
Be sure the power cord is disconnected before you add a NIM card.
2.
Place the XSR on a flat, static-free surface.
3.
Remove the XSR cover from the chassis, as shown in Figure 2-1, by first removing screws from
the side and top.
Figure 2-1
Removing XSR Cover
SECURITY ROUTERS
XSR-3150
NIM1
NIM 1
NIM2
NIM 2
VPN
1000
10/100/1000
10/100/1000
Link
SYS
PWR
COM
2-2
Hardware Installation
COM
TX
GBIC
ETH3
ETH1
ETH2
Installing NIM Cards and Rack Mounting
4.
Remove the NIM slot cover, as shown in Figure 2-2, by grasping the handle and pressing it to
the side before pulling it out.
Figure 2-2
SE
XS
CU
RIT
R-
YR
OU
31
Removing NIM Slot Covers
TE
RS
50
NIM
1
NIM
5.
2
Carefully attach the NIM card(s) to the connector on the motherboard and secure with four
screws, as shown in Figure 2-3.
Figure 2-3
Attaching NIM card to Motherboard
SECURITY ROUTERS
XSR-3150
NIM1
NIM 1
NIM2
NIM 2
VPN
Link
SYS
1000
10/100/1000
10/100/1000
PWR
COM
6.
COM
TX
GBIC
ETH1
ETH2
ETH3
Re-install the chassis cover.
XSR Getting Started Guide
2-3
Installing NIM Cards and Rack Mounting
7.
Attach the rack brackets to the chassis with the screws supplied, as shown in Figure 2-4.
Figure 2-4
Fastening Rack Brackets
SE
CU
Y RO
XS
R-3 UTERS
15
0
RIT
NIM
1
NIM
2
NIM1
NIM2
SY
PW
S
VP
R
N
CO
M
Lin
k
CO
M
10
00
10
TX
/100
/100
GB
IC
0
10
ET
H1
/100
ET
H2
8.
/100
Mount the bracketed XSR to your rack, as shown in Figure 2-5.
Figure 2-5
Attaching XSR to Rack
SE
CU
Y RO
XS
R-3 UTERS
15
0
RIT
NIM
1
NIM
2
NIM1
NIM2
SY
PW
S
VP
R
N
CO
M
CO
M
Lin
k
10
00
TX
10
/100
/100
GB
IC
0
10
ET
H1
/100
ET
H2
2-4
0
ET
H3
Hardware Installation
/100
0
ET
H3
Installing a CompactFlash Memory Card
Installing a CompactFlash Memory Card
An optional CompactFlash (CF) memory card provides additional non-volatile storage
capabilities in 8, 16, 32, or 64 Mbyte increments. The CF’s controller interfaces with a host system
allowing data to be written to and read from the CF’s flash memory module. The XSR supports
Type I and II CompactFlash card types. Refer to Figure 2-6 for a generic illustration of the card.
The CF’s memory is large enough to store image files. You can do so simply by using the Bootrom
Monitor mode copy command. For example, to copy a file from the Onboard flash: directory to the
cflash: directory while in the flash: directory, enter:
XSR>copy <source_name> cflash:<destination_name>
Figure 2-6
Typical CompactFlash Card
Pin 1
Pin 50
CompactFlash Card Installation
Follow the steps below to install the CompactFlash card:
1.
If your CF is already formatted, first remove the cover plate as shown in Figure 2-7. If it is not
formatted, jump to “Formatting the CompactFlash Card” on page 2-6.
Figure 2-7
SE
CU
RITY
XS
R-3
Removing CompactFlash Coverplate
RO
UT
ER
S
15
0
NIM
1
NIM
2
NIM
1
NIM
2
SY
S
VP
N
PW
R
CO
M
CO
M
Lin
k
10
00
TX
10
/10
0/1
00
GB
IC
0
10
/10
ET
H1
ET
H2
2.
0/1
00
0
ET
H3
Seat the card in the PCMCIA interface as shown in Figure 2-8.
XSR Getting Started Guide
2-5
Installing a CompactFlash Memory Card
Gently insert the CF into the slot, taking care that the CF’s wider grooved edge fits into the
wider track of the PCMCIA interface. If the card does not seat easily but stops halfway into the
slot, do not force it in - the card was inserted incorrectly. Flip it over and re-insert. Note that
the XSR’s CF eject mechanism pops out for easy removal when you install the card.
Figure 2-8
Installing CompactFlash Card
NIM
1
NIM
2
SY
S
PW
R
VP
N
CO
M
SE
CU
XS
RITY
R-3
RO
UT
ER
15
0
S
NIM
1
NIM
2
NIM
1
NIM
2
SY
PW
S
VP
R
N
CO
M
CO
M
Lin
k
10
00
TX
GB
IC
10
/10
0/1
00
0
ET
H1
10
/10
0/1
00
0
ET
H
2
ET
H3
CompactFlash Card for the ADSL NIM
The ADSL NIM is shipped with a CompactFlash card carrying the DSP firmware necessary for
connecting to a DSAM. Refer to Figure 2-13 for an illustration and installation instructions.
Formatting the CompactFlash Card
If your CF is not formatted, there are two ways you can format the card:
2-6
•
Use the XSR Bootrom Monitor Mode ffc command. A few seconds after you boot up the XSR,
press the CTRL-C keys and a password prompt will appear. Press ENTER (factory default) if
you have not defined any password. The Bootrom Monitor Mode will appear. Enter ffc and
the router will complete the formatting.
•
Install the CF in a PCMCIA card and enter the Windows format command. For further
instructions, refer to Windows documentation.
•
After completing CF formating via Bootrom Monitor Mode, use the bc command to restart the
XSR in normal mode.
Hardware Installation
Connecting Cables
Connecting Cables
Perform any of the following steps to connect your cabling to optional WAN or LAN NIMs,
GigabitEthernet ports, and power supplies:
1.
Connect the serial COM cable provided in the packing box to your PC connector, as shown in
Figure 2-9.
Figure 2-9
CO
Connecting Serial COM (Console) Cable
Lin
M
k
10
00
TX
10
/10
0/1
00
GB
0
10
/10
IC
ET
H1
0/1
00
0
ET
H2
ET
H3
2.
Connect WAN cables to the T1/PRI or BRI port(s), or High Speed Serial, T3/E3, ADSL, or T1
Drop & Insert WAN ports, as shown in Figure 2-10, Figure 2-11, Figure 2-12, Figure 2-13, or
Figure 2-14, respectively.
Figure 2-10
SE
Attaching T1/PRI or BRI Port Connector
CU
XS ITY ROU
TE
R31 RS
50
R
NIM
1
NIM
2
XSR Getting Started Guide
2-7
Connecting Cables
Figure 2-11
Connecting High Speed Serial Connector
SE
CU
XS
RIT
R-
YR
OU
31
TE
50
RS
NIM
1
NIM
Figure 2-12
2
Attaching T3/E3 BNC Connectors
SE
CU
RIT
YR
OU
TE
RS
XS
R-
31
50
Tx
NIM
AL
1
AR
M
LO
S
EN
AB
LE
LO
F
Rx
id
NIM
2-8
Hardware Installation
2
Connecting Cables
Figure 2-13
SE
CU
XS
Connecting ADSL Connector
RIT
R-
YR
OU
31
TE
50
RS
NIM
1
NIM
2
A CompactFlash card is provided with the XSR ADSL NIM. It is loaded with the Digital Signal
Processing (DSP) firmware (adsl.fls) required to communicate with your DSLAM. When
inserted into the Compact Flash slot - upon first configuring an ATM interface - the XSR’s ADSL
driver will copy adsl.fls into host memory where it will remain available for use on demand. Be
aware that if all ATM interfaces are deleted, adsl.fls must be recopied into Flash.
Note: The XSR supports one installed ADSL NIM card type at a time (multiple installed cards must
be of the same type).
Figure 2-14
SE
XS
Attaching T1 Drop & Insert Connector
CU
R-
RIT
YR
OU
31
TE
RS
50
NIM
1
NIM
2
XSR Getting Started Guide
2-9
Connecting Cables
3.
Connect the Ethernet port(s) to your LAN connectors with a cable, as shown in Figure 2-15.
Figure 2-15
CO
M
Lin
k
10
00
TX
Attaching GigabitEthernet Connector
10
/10
0/1
00
0
GB
10
/10
IC
0/1
ET
00
H1
0
ET
H2
ET
H3
4.
Insert the Mini-GBIC module in the GBIC slot then connect the optical cable, as shown in
Figure 2-16.
Figure 2-16
CO
Inserting Mini-GBIC Module
Lin
M
k
10
00
TX
GB
10
/10
0/1
00
0
10
IC
ET
ET
2-10
Hardware Installation
/10
H1
H2
0/1
00
0
ET
H3
Connecting Cables
Attach either the Ethernet or Fiber Ethernet LAN NIM, as shown in Figure 2-17 and
Figure 2-18, respectively.
Figure 2-17
Attaching Ethernet LAN NIM Connector
SE
CU
RIT
YR
OU
TE
RS
XS
R-
31
50
NIM
1
NIMETHR01
LINK ACT
NIM
Figure 2-18
RIT
YR
OU
31
TE
50
RS
NIM
1
NIMFIBR01
CU
R-
Attaching Ethernet Fiber LAN NIM Connector
ACT
SE
XS
2
LINK
5.
NIM
2
XSR Getting Started Guide
2-11
Connecting Cables
6.
Attach the dual power supply cords to the connectors at the rear of the XSR, as shown in
Figure 2-19, and plug in the country-specific power cords to a wall socket. The XSR will power
up.
Figure 2-19
Connecting Dual Internal Power Supply Cords
10 LI
0~ NE
20 125V
0~
24 ~1
0V .25
50 ~0 A
/60 .65
Hz A
10 LI
0~ NE
20 125V
0~
24 ~1
0V .25
50 ~0 A
/60 .65
Hz A
You are now ready to configure the software and initialize the XSR. Continue with “Software
Configuration” on page 3-1.
2-12
Hardware Installation
3
Software Configuration
This chapter describes how to initialize, quickly set up and verify your configuration for the XSR.
Refer to the XSR CLI Reference Guide for a more thorough explanation of commands and parameter
options. The chapter also includes sample configuration scripts, detailed XSR rebooting
characteristics and Bootrom Monitor mode instructions.
Software configuration comprises the following procedures:
•
Initialize the software
•
Open a console (COM) session to the XSR
•
Name the XSR and add users/passwords
•
Set up LAN ports
•
Configure WAN ports for dialer and backup dialer service
•
Configure the Firewall feature set
•
Configure IP routing: RIP or OSPF
•
Configure Frame Relay networks
•
Set up a backup line
•
Create an SNMP community string and traps
•
Configure message logging and severity level
•
View your configuration
•
Connect via SSH, Telent or the Web
•
LAN/PPP Services Sample Configuration
•
Frame Relay WAN Link and PPP Backup Sample Configuration
•
VPN configurations (see the XSR User’s Guide for a Client example)
Initializing XSR Software
1.
Be sure the NIM cards are installed and cable connections are snug.
2.
Attaching the power cord (as described in Chapter 2) powers on the XSR. The LED sequence
proceeds as follows:
• Power LED turns ON.
• All LEDS flash quickly on and off starting from the SYS LED on the left, proceeding to the
right.
XSR Getting Started Guide
3-1
Initializing XSR Software
• ETH 10/100/1000 LEDs turn ON and OFF a few times during initialization as the XSR
proceeds from bootrom to power up diagnostics to software image, then they remain ON or
OFF depending on the LAN type.
• ETHERNET Activity LEDs blink when frames pass on the LAN.
• COM Activity LED is OFF until the CLI comes up. Then it blinks ON/OFF during console
keyboard input or output.
• NIM LEDs are OFF until the CLI comes up. Then they are turned ON if a supported card is
present (T1/E1 or Serial), and the card passes the power-up diagnostics test.
3.
XSR software initializes in two phases. A cold start (including power cycling) is marked by
diagnostic and router software phases. A warm start skips the powerup diagnostics and boots
to router software. First-time startup is a cold start with the following sequence of events:
• Basic hardware initialization of the processor, memory, and other components occurs.
• Bootrom Monitor mode is accessible now and can be entered by pressing a special key
combination within a 5-second interval. For more information, refer to “Bootrom Monitor
Mode Commands” on page 3-35.
• Power-up diagnostics test the following hardware blocks:
–
RAM size is detected
–
On-board Flash size is detected
–
GigabitEthernet is checked
–
Ethernet on motherboard is checked
–
NIM cards 1 and 2 is checked
–
Real-Time Clock are checked
–
Front panel LEDs are set to reflect current status
• Diagnostics test results are saved for later use by system software.
• The software image in Flash memory is verified by checksum.
–
If no valid image exists in flash: or cflash:, Bootrom Monitor mode is acquired.
–
If the default file (xsr3000.fls) is not found as specified in Bootrom mode, an FTP/TFTP
server as defined in network parameters of Bootrom mode is queried.
–
If the image is not found remotely, initialization is suspended in Bootrom mode.
Note: Optionally, you can create a boot-config file to identify the name of a firmware file from which
the XSR boots. Refer to the boot system command in the XSR CLI Reference Guide for more
information.
• A valid image in Flash memory, if present, is decompressed.
• The decompressed software image is loaded into RAM.
• Execution is passed to the software image.
• The operating system is started.
• The Flash startup configuration files (startup-config, private-config) become the running
configuration.
• All software modules are initialized. If an error occurs when processing startup-config, the
CLI will continue processing the file until the end. If the file contains more than one error,
3-2
Software Configuration
Opening a COM (Console) Session
only the first error will be reported, along with a count of the sum of errors incurred. In the
case of a single error, only the error line will be reported. Error messages will be logged as
well. Because the result of continuing to process a flawed startup-config is not predictable,
the nature and position of the syntax error may cause the erroneous configuration of the
XSR.
• Router ports and protocol stacks are initialized based on startup configuration.
• Alarms and messages reported during initialization are logged.
• COM is up.
• The XSR is up.
To view the screen output produced when the XSR reboots, refer to “XSR Rebooting
Characteristics” on page 3-33.
Opening a COM (Console) Session
1.
Open a COM session to the XSR using Procomm or another program.
Set the session properties as follows: BPS - 9600, Data bits - 8, Parity - none, Stop bits - 1, Flow
control - none. Refer to “Initialization Output” on page 3-33 to view XSR initialization data.
2.
When the XSR login appears, enter admin and enter no (blank) password. Note that logins
and passwords can be changed later.
Note: You can abort RAI at any time by pressing any key.
Refer to the following section for quick configuration of RAI. For a full description of RAI
including how it works, refer to “Chapter 2: Managing the XSR” in the XSR User’s Guide.
Optional: Configuring Remote Auto Install
In short, the RAI application transports a startup configuration file from a TFTP server for use in
configuring the remote XSR. This file is placed in the Flash: directory as the startup-config and
executed via the normal startup process. RAI is supported on a Frame Relay network running on a
serial NIM card (configuration example shown below), RAI over Ethernet (with DHCP), RAI PPP
over a Leased line or RAI over an ADSL network.
For remote XSR setup, you need only hook up cabling as described in ”Chapter 2: Hardware
Installation” of this guide.
Configuring RAI for Frame Relay
To configure two remote XSRs with RAI over Frame Relay, perform the following setup on the
central site. On multi-point Serial sub-interface 1/0.1, configure DLCIs 16 and 18 to statically map
to IP addresses 133.133.1.2 and 133.133.1.3. If the DLCI will onnect to a remote XSR running RAI,
then add the bootp parameter after the static IP address.
This configuration supports two remote XSRs connected on DLCIs 16 and 18. Make sure with your
Frame Relay provider that these DLCIs terminate at the location of the remote XSRs. To add more
remote XSRs, you will need additional DLCIs.
XSR Getting Started Guide
3-3
Optional: Configuring Remote Auto Install
Note the use of a helper-address to specify a destination address for UDP broadcasts and forward
traffic to the DNS and TFTP servers. In the example below, DNS and TFTP servers reside on the
same node - 10.10.1.2 (configuration of DNS and TFTP servers are not shown here). In short, the
DNS server should map IP addresses 133.133.1.2 and 133.133.1.3 to hostnames. On the TFTP
server, you should create a startup-config file with names <hostname>-config in a directory
accessible by TFTP.
XSR(config)#interface serial 1/0.1 multi-point
XSR(config-if<S1/0.1>)#ip helper-address 10.10.1.2
XSR(config-if<S1/0.1>)#ip address 133.133.1.1
XSR(config-if<S1/0.1>)#frame-relay interface-dlci 16 ip 133.133.1.2 bootp
XSR(config-if<S1/0.1>)#frame-relay interface-dlci 18 ip 133.133.1.3 bootp
XSR(config-if<S1/0.1>)#no shutdown
XSR(config-if<S1/0.1>)#exit
XSR(config)exit
XSR#copy running-config startup-config
RAI displays the following phased output on the remote node. Refer to the accompanying notes
for additional explanation of phases.
********************* REMOTE AUTO INSTALL STARTING ***************
+ RAI is starting up.
************* REMOTE AUTO INSTALL ATTEMPTING FOREVER **************
+ Persistent (or Non-Persistent) RAI is attempted.
Phase 0 - Initialization and Starting search for proper media-type
Phase 0 - Trying media-type V35
******** PRESS ANY KEY TO TERMINATE REMOTE AUTO INSTALL ***********
+ A periodic reminder that you can terminate the program at any time by depressing any key on your keyboard. Be aware
that any existing startup-config that may exist in the node will be executed.
Phase 1 - Trying media-type RS232
+ Upon failing, the next media-type is tried.
Phase 1 - Frame Relay interface Serial 1/0 reported DLCI 16 active
+ Frame Relay has successfully found a FR network with active DLCIs.
Phase 2 - transmitting bootp - attempt #1
+ The bootp client is sending out a request. At most, five requests will be tried.
Phase 3 - received IP address: 133.133.1.2
+ The bootp client has received a response and the IP address for this interface is 133.133.1.2.
Phase 4 - Sending out Reverse DNS query onto Frame Relay
+ rDNS is sending out a query looking for the hostname for IP address 133.133.1.2
Phase 6 - getting hostname xsrnode-confg from tftp server into flash: startupconfig
+ rDNS has responded with the hostname xsrnode which will be used in the TFTP transfer. RAI will try several file names
if this file is not available from the server.
Phase 7 - preparing node to execute startup-config
3-4
Software Configuration
Optional: Configuring Remote Auto Install
+ TFTP transfer succeeded in copying the hostname file to the Flash: startup-config file.
****************** REMOTE AUTO INSTALL TERMINATING*****************
+ The RAI process is complete and is preoceding to system initialization where it will process the new startupconfig file.
Configuring RAI for DHCP over LAN
The following example configures DHCP server to be used with RAI over Ethernet. Note that
there is no need for a DNS server because the startup-config name is provided by the DHCP
server. Begin by creating an IP local pool which will include the Fast/GigabitEthernet interface
address:
XSR(config)#ip local pool dhcp 200.1.0.0 255.255.255.0l
Next, configure the interface that will service the remote device, set the IP address inside the pool
defined earlier, and enable DHCP Server:
XSR(config)#interface
XSR(config-if<G2>)#ip
XSR(config-if<G2>)#ip
XSR(config-if<G2>)#no
GigabitEthernet 2
address 200.1.0.4 255.255.255.0
dhcp server
shutdown
Now configure the following DHCP Client parameters:
XSR(config)#ip dhcp pool dhcp
XSR(config-dhcp-pool)#lease 0 0 10
+ This command sets a lease interval of 10 minutes
XSR(config-dhcp-pool)#hardware-address 0001.f412.2334
+ This command sets the MAC address of the client
XSR(config-dhcp-pool)#host 200.1.0.66 255.255.255.0
+ This command binds 200.1.0.66/24 to the earlier configured hardware address
XSR(config-dhcp-pool)#option 12 instance 0 ascii etr1
+ This command sets the Client hostname as etr1
XSR(config-dhcp-pool)#option 150 instance 0 ip 1.1.1.1
+ This command configures the TFTP server IP address to 1.1.1.1
XSR(config-dhcp-pool)#option 67 instance 0 ascii etr1-startup-confg
+ This command enters the config-file name as startup-config
Remember to save your configuration after all edits.
Configuring RAI over ADSL
In the following example, a remote XSR is connected to an ADSL network at the central site with a
PPPoE server. A TFTP server runs on a separate machine - 192.168.72.118, while the PPPoE server
runs on a CISCO router. The PPPoE server can reside on any other device providing PPPoE
session termination and has a mechanism to direct TFTP broadcast packets to a specific IP address.
A DNS server is not required with this method because RAI over ADSL uses the serial number of
the XSR for the startup-config name.
The following is a CISCO configuration at the the central site:
vpdn enable
+ Enables a virtual private dial-up network configuration on the router.
vpdn-group 1
XSR Getting Started Guide
3-5
Optional: Configuring Remote Auto Install
+ Creates a VPDN session group and links it to a virtual template.
accept-dialin
protocol pppoe
virtual-template 1
pppoe limit per-mac 10
+ This is an optional command.
pppoe limit max-sessions 32000
+ This is an optional command.
interface GigabitEthernet1/0/0
no ip address
negotiation auto
!
interface GigabitEthernet1/0/0.10
encapsulation dot1Q 20
pppoe enable
pppoe max-sessions 10
+ Optional. This command enables PPPoE and allows PPPoE sessions to be created through this sub-interface.
!
interface Virtual-Template1
ip unnumbered loop 0
mtu 1492
peer default ip address pool pool1
ppp authentication pap
ip helper-address 192.168.72.118
+ This is the address of the TFTP server.
ip directed-broadcast
+ This command configures the virtual template interface.
!
ip local pool pool1 192.168.0.1 192.168.0.100
username 0000019876543210 password 0 0000019876543210
+ Enter the remote XSR’s serial number.
aaa new-model
!
aaa authentication ppp default local ! look at local database first
aaa authentication ppp dialins local
+ Specifies the IP local pool to use for address assignment.
When the RAI process begins, the remote XSR displays the following messages:
**************** PRESS ANY KEY TO TERMINATE REMOTE AUTO INSTALL ***************
Phase 2 - ADSL - searching for pvc's ...Training (60 sec)
+ The XSR begins training with the DSLAM, waiting 60 seconds.
Phase 2 - ADSL - searching for pvc's ...Training (54 sec)
Phase 2 - ADSL - searching for pvc's ...
+ Training is successful, discovery of VPI/VPCs begins.
Phase 2 - ADSL - searching for pvc's ...vpi/vci (0/0)
+ The XSR looks for PVC 0/0 and higher.
Phase 2 - ADSL - searching for pvc's ...vpi/vci (0/38)
+ The XSR looks for PVC 0/38 and higher.
3-6
Software Configuration
Configuring the XSR Name and User Information
Phase 3 - ADSL - trying to connect on 0/35 with snap PPPoE
+ PVC 0/35 is found, SNAP PPPoE encapsulation is applied and authentication tried if required.
Phase 3 - ADSL - waiting for IP to connect (54 sec)
+ The XSR waits one minute for the PPPoE connection to come up.
Phase 4 - ADSL - IP is connected on 0/35, prepare to load startup config
+ The XSR starts downloading the startup-file.
Phase 6 - ATM/ADSL - retrieving file 0000019876543210-confg from tftp server 25
5.255.255.255
+ The startup-config name is the serial number of the XSR.
Phase 7 - preparing node to execute startup-config
Configuring the XSR Name and User Information
1.
At the CLI prompt, enter enable to acquire Privileged EXEC mode.
2.
Enter configure to acquire Global mode.
3.
Enter hostname <your XSR designation>.
4.
Enter username <name> <privilege level> password <cleartext | secret> <0 | 5> <password>.
5.
Enter banner login <your welcome text> to add a user login banner.
Remember to save your configuration after all edits.
Setting User Name, Privilege and Password
The value <name> is the user’s designation - for sake of clarity, often set as the name of the facility
or site the XSR connects to. The value <privilege level> (0-15) prioritizes this user in terms of
configuration rights with 15 as the highest and 0 the lowest (default). When you create a new user
you can decide which privilege that user will have (if you are admin). For example, a user with
privilege 7 will be allowed to execute only commands with privilege levels between 0 and 7.
Default privilege levels are defined for all commands and the admin user and are listed in the XSR
CLI Reference Guide under the privilege command. You can change a command’s default
privilege by entering: privilege <configuration_mode> level <0-15> <command |
command_group>.
The value <cleartext | secret> can be sent in the clear or encrypted with a 0 (the input password is
not expected to be unencrypted so the XSR will encrypt it) or 5 (the input password is expected to
already be encrypted so it will not be encrypted again). The value <pass> is the password
associated with the specified name. The MD5 algorithm is encrypts the password.
Note: Newly created users are stored in the startup config file. You can also delete admin but only if
you first create another level 15 user.
Setting the Clock
XSR 1800 and 3000 Series routers have an on-board Real Time Clock (RTC) chip with which to
keep accurate time across the network. As an alternative to accessing a public time server, you can
utilize the RTC as a time reference and propagate it by configuring XSRs as Simple Network Time
Protocol (SNTP) servers or clients. XSR 1200 Series routers do not carry an RTC chip, however, and
if your topology includes these devices you must synchronize them from an external source.
XSR Getting Started Guide
3-7
Configuring the LAN Ports
Enter the following command to configure the XSR as an SNTP client:
XSR(config)#sntp-client server [primary | A.B.C.D.][alternate | A.B.C.D.]
Enter the following command to configure the XSR as an SNTP server:
XSR(config)#sntp-server enable
Remember to save your configuration after all edits.
Configuring the LAN Ports
1.
Enter interface gigabitethernet <1 | 2 | 3> to acquire Interface mode and select one of the
GigabitEthernet ports.
2.
Enter ip address <xxx.xxx.xxx.xxx> <yyy.yyy.yyy.yyy> where x is the IP address and y is the
subnet mask of this GigabitEthernet port.
3.
Enter no shutdown to keep the interface enabled.
4.
Enter show ip interface gigabitethernet <1 | 2 | 3> to verify LAN settings.
5.
Enter copy running-config startup-config to save your settings.
Remember to save your configuration after all edits.
Configuring the WAN Ports
For ISDN PRI configuration, continue below; or see “BRI Configuration” on page 3-9, or “ADSL
Configuration” on page 3-11.
PRI Configuration
1.
Enter controller <t1 | e1> <slot # | card # | port #> of the first installed T1/E1/ISDN-PRI NIM
to acquire Controller mode and set up the physical port.
2.
Enter no shutdown to keep the interface enabled.
The above commands add either one channel-group 0 having 24 timeslots for the T1 controller
with default values for framing set to ESF, B8ZS line encoding, and line clock source, or one
channel-group 0 having 31 timeslots for the E1 controller including crc4 framing, hdb3 line
encoding, and line clock source defaults. For a non-default configuration, go to Step 3.
3.
Enter clock source <line | internal | internal synchronization> to select where the XSR will
derive its timer for synchronized data transmission.
The line source derives from the network, internal derives from a chip on the XSR, and
internal synchronization derives from the first T1/E1/ISDN-PRI card by clock transfer.
3-8
4.
Enter no channel-group <number> to delete the default group.
5.
Enter channel-group <number> timeslot <number> <speed> <number> to create a channel
group.
Software Configuration
Configuring the WAN Ports
This command allows multiple logical WAN interfaces to be created on a single channelized
T1/E1/ISDN-PRI port, ranging from 0 - 23 for T1 lines, and 0 - 31 for E1 lines. Also, from 1 - 24
T1 and 1 - 31 E1 timeslots can be set. Channel speed options are 56 (T1) or 64 (E1) kbps.
Note: Channel group and timeslot number ranges are different. Be sure to match them correctly and
within the range. Also, when adding a second T1 or E1, be sure to begin channel numbering again
at 0.
6.
Enter framing <sf | esf | crc4 | no-crc4> to set the framing type.
The value you set must match the type and format offered by your service provider and must
correlate with the NIM card you are configuring: sf or esf for T1 cards, and crc4 or no-crc4 for
E1 cards.
7.
Enter linecode <ami | b8zs | hdb3> to configure the encoding type.
This setting must match your service provider’s linecode type and type of NIM card installed:
B8ZS for T1 only, HDB3 for E1 only, and AMI for both T1/E1.
8.
Enter interface serial <slot # | card # | port #> of the serial NIM card to acquire Interface mode
and configure the logical interface.
9.
Enter encapsulation ppp to set the encapsulation type.
10. Enter ppp authentication <chap [ms-chap] [pap] | pap [ms-chap] [chap] | ms-chap [chap] [pap]>
for the authentication type on the port.
11. Enter ip address <xxx.xxx.xxx.xxx> <yyy.yyy.yyy.yyy> where x is the IP address and y is the
subnet mask of the serial port.
12. Enter backup interface dialer <number> to allow the serial interface to set the specified dialer
interface as a dialed backup.
13. Enter no shutdown to keep the interface enabled.
14. Enter show controller <T1 | E1> <slot/card/port> to verify NIM settings.
15. Enter show interface serial <slot# | card#: channel#> to verify serial port settings.
16. Enter show ppp interface serial <card#|port#:channel#> to display PPP status on the interface.
17. Enter show dialer to verify your dialer interface configuration.
Remember to save your configuration after all edits.
BRI Configuration
ISDN BRI can be configured on a leased (over PPP or Frame Relay) or non-leased, switched line.
Continue configuration with the BRI type of your choice.
BRI Leased Line
1.
Enter interface bri 0:<1 | 2> to acquire Interface mode and select the BRI port and channel
1 or 2.
2.
Enter leased-line <64 | 128> to acquired BRI interface mode and select 64 or 128 kbps line
speed. Selecting 128 assigns B1 and B2 timeslots to channel 1 while 64 assigns either B1 or B2
timeslots to channel 1 or 2.
3.
Enter ip address <xxx.xxx.xxx.xxx>/24 to set an IP address for the BRI interface.
XSR Getting Started Guide
3-9
Configuring the WAN Ports
4.
Enter encapsulation ppp to select PPP encoding.
5.
Enter no shutdown to keep the BRI interface enabled.
BRI Leased Frame Relay
1.
Enter interface bri 0:<1 | 2>.<1-30> to acquire BRI Interface mode and select the BRI
port and channel 1 or 2.
2.
Enter encapsulation frame-relay to select Frame Relay encoding.
3.
Enter no shutdown to keep the BRI interface enabled.
4.
Enter frame-relay lmi-type <ilmi | ansi | q933a | auto | none> to select the Local
Management Interface type.
5.
Enter interface bri 0:<1 | 2>.<1-30> multi-point to acquire BRI Sub-interface mode and
select the BRI port, channel, and sub-interface.
6.
Enter ip address <xxx.xxx.xxx.xxx>/24 to set an IP address for the BRI interface.
7.
Enter frame-relay interface-dlci <16-1007> to acquire Frame Relay DLCI Interface
mode and assign a data-link connection identifier to the Frame Relay sub-interface.
8.
Enter no shutdown to keep the BRI sub-interface enabled.
BRI Switched Line
1.
Enter interface bri 0 to acquire Interface mode and select the BRI port.
2.
Enter isdn switch-type <basic-5ess | basic-dms100 | basic-net3 | basic-ni1 |
basic-ntt> to select the Central Office switch type for the ISDN port.
3.
Enter isdn spid1 <SPID><LDR> for the SPID (ISDN service) and LDR (local directory)
telephone numbers.
4.
Enter isdn spid2 <SPID><LDR> for a second SPID as needed.
5.
Enter no shutdown to keep the BRI interface enabled.
6.
Enter dialer pool-member <1-255> priority <0-255> to add a dialer pool and associated
priority to this BRI interface. You can add additional dial pools as needed.
7.
Enter exit to quit BRI Interface mode.
8.
Enter interface dialer <0-255> to acquire Interface mode and select the Dialer port.
9.
Enter ip address <xxx.xxx.xxx.xxx/24 to set an IP address for the Dialer port.
10. Enter encapsulation ppp to select PPP encoding.
11. Enter dialer string <phone number> class <Map Class name> to specify the destination
number and associated Map Class.
12. Enter any additional dialer strings as instructed above.
13. Enter dialer pool <1-255> to create a dial pool from which the dialer interface will select a
physical interface.
14. Enter show interface to verify your ISDN and dialer configuration.
15. Enter no shutdown to keep the Dialer interface enabled.
Remember to save your configuration after all edits.
3-10
Software Configuration
Configuring the WAN Ports
ADSL Configuration
ADSL can be configured using three different types of encapsulation: PPPoA, PPPoE, and IPoA.
Continue configuration with the ADSL type of your choice.
PPPoE
The following commands configure a sample PPPoE topology. The first set configures the LAN
interface with directed broadcasts prohibited.
XSR(config)#interface
XSR(config-if<F1>)#ip
XSR(config-if<F1>)#no
XSR(config-if<F1>)#no
FastEthernet 1
address 192.168.1.1 255.255.255.0
ip directed-broadcast
shutdown
The commands below configure the ATM interface and sub-interface with a negotiated IP address,
PAP username and password, and ban keepalives. They also reset default PVC VPI and VCI
values to those requested by the DSL provider. Notice that the Maximum Segment Size (MSS) is
set to 1400 bytes for TCP SYN (synchronize) packets. Because a PC connected to a Fast/
GigabitEthernet port may be unable to access Web sites if its MSS setting is too high, subtracting
for the PPPoE, IP, TCP, and GRE headers (6, 20, 20, and 24 bytes, respectively) and the PPP
Protocol ID should avoid that problem.
XSR(config)#interface ATM 0
XSR(config-if<ATM0/0>)#no shutdown
XSR(config-if<ATM0/0>)#interface ATM 0.1
XSR(config-if<ATM0/0.1>)#no shutdown
XSR(config-if<ATM0/0.1>)#encapsulation mux pppoe
XSR(config-if<ATM0/0.1>)#ip address negotiated
XSR(config-if<ATM0/0.1>)#ip mtu 1492
XSR(config-if<ATM0/0.1>)#ip tcp adjust-mss 1400
XSR(config-if<ATM0/0.1>)#ppp pap sent-username user@net password letmein
XSR(config-if<ATM0/0.1>)#no ppp keepalive
XSR(config-if<ATM0/0.1>)#pvc 0/100
The following optional commands configure two default routes:
XSR(config)#ip route 0.0.0.0 0.0.0.0 30.0.0.10
XSR(config)#ip route 30.0.0.10 255.255.255.255 ATM 0.1
The following optional commands configure NAT:
XSR(config)#access-list 99 permit 192.168.1.0 0.0.0.255
XSR(config)#interface FastEthernet 1
XSR(config-if<F1>)#ip nat source list 99 assigned overload
PPPoA
Enter the following commands to configure PPPoA. The first set configures the LAN interface
with directed broadcasts prohibited.
XSR(config)#interface
XSR(config-if<F1>)#ip
XSR(config-if<F1>)#no
XSR(config-if<F1>)#no
FastEthernet 1
address 192.168.1.1 255.255.255.0
ip directed-broadcast
shutdown
XSR Getting Started Guide
3-11
Firewall Sample Configuration
The commands below configure the ATM interface and sub-interface with a negotiated IP address,
CHAP username and password, and bans keepalives.
XSR(config)#interface ATM 0
XSR(config-if<ATM0/0>)#no shutdown
XSR(config-if<ATM0/0.1>)#interface ATM 0.1
XSR(config-if<ATM0/0.1>)#no shutdown
XSR(config-if<ATM0/0.1>)#encapsulation snap pppoa
XSR(config-if<ATM0/0.1>)#ip address negotiated
XSR(config-if<ATM0/0.1>)#ip mtu 1492
XSR(config-if<ATM0/0.1>)#ip tcp adjust-mss 1400
XSR(config-if<ATM0/0.1>)#ppp chap hostname red password sox
XSR(config-if<ATM0/0.1>)#no ppp keepalive
Note: If you have configured a VPN tunnel and wish to avoid intermittent Web browser problems,
add the crypto ipsec df-bit clear command to your configuration.
IPoA
Enter the following commands to configure a IPoA topology:
XSR(config)#interface ATM 0
XSR(config-if<ATM0/0>)#no shutdown
XSR(config-if<ATM0/0>)#interface ATM 0.1
XSR(config-if<ATM0/0.1>)#encapsulation snap ipoa
XSR(config-if<ATM0/0.1>)#ip address 192.168.1.1 255.255.255.0
XSR(config-if<ATM0/0.1>)#ip mtu 1492
XSR(config-if<ATM0/0.1>)#exit
XSR(config)#ip route 0.0.0.0 0.0.0.0 30.0.0.10
XSR(config)#ip route 30.0.0.10 255.255.255.255 ATM 0.1
Firewall Sample Configuration
In this scenario, the XSR acts as a router connecting a branch office to the Internet, as illustrated in
Figure 3-1. The branch office has two servers (Web and Mail) accessible from the external world
and an internal network of hosts which are protected from the external world by the firewall. The
Web and Mail servers are part of the DMZ and considered internal by the XSR. Note that some
commands have been abbreviated.
3-12
Software Configuration
Firewall Sample Configuration
Figure 3-1
XSR with Firewall Topology
220.150.2.32/28
XSR
Frame Relay
Internet
S1
206.12.44.16/28
220.150.2.35
SECU
RITY
ROUT
XSR
ERS
-185
0
POW
ER
220.150.2.37
10/10
0BT
SYS
ACT
VPN
ETHE
RNET
PORT
1
10/10
0BT
ACT
ETHE
RNET
PORT
2
CONS
OLE
NIM
1
NIM
FE1
2
FE2
220.150.2.17
Internal
220.150.2.16/28
220.150.2.36
DMZ
Mail server
(SMTP)
220.150.2.18
Web server
(HTTP)
220.150.2.19
In this configuration, the firewall provides protected access from the private to dmz networks. That
is, access is restricted to Web and mail traffic only. The hosts in the private network are provided
full access to the Internet but access is denied from the Internet to the private network. Also, all Java
and ActiveX pages, IP options, IP broadcast and multicast packets are banned.
Begin by specifying network objects for private, dmz, and Mgmt networks:
XSR(config)#ip firewall network dmz 220.150.2.16 mask 255.255.255.240 internal
XSR(config)#ip firewall network private 220.150.2.32 mask 255.255.255.240
internal
XSR(config)#ip firewall network Mgmt 220.150.2.35 mask 255.255.255.0 internal
Log only critical events:
XSR(config)#ip firewall logging event-threshold 3
Set policies between the dmz and external networks. Note that policy objects and names are casesensitive and you must cite network names exactly:
XSR(config)#ip
XSR(config)#ip
XSR(config)#ip
XSR(config)#ip
firewall
firewall
firewall
firewall
policy
policy
policy
policy
a1
a2
a3
a4
private dmz
dmz private
private dmz
dmz private
HTTP
HTTP
HTTP
HTTP
allow
allow
allow
allow
Set the policies between the dmz and external networks:
XSR(config)#ip
XSR(config)#ip
XSR(config)#ip
XSR(config)#ip
firewall
firewall
firewall
firewall
policy
policy
policy
policy
a5
a6
a7
a8
ANY_EXTERNAL dmz
dmz ANY_EXTERNAL
ANY_EXTERNAL dmz
dmz ANY_EXTERNAL
SMTP
SMTP
SMTP
SMTP
allow
allow
allow
allow
Set policies to allow any traffic from private to external and Mgmt networks:
XSR(config)#ip firewall policy a9 private ANY_EXTERNAL ANY_TCP allow
XSR(config)#ip firewall policy Telnetsess Mgmt Mgmt Telnet allow bidirectional
Allow ICMP traffic to pass from the dmz to private, private to all external, and all external to private
networks:
XSR Getting Started Guide
3-13
Setting Up RIP Routing
XSR(config)#ip firewall filter allowICMP private dmz protocol-id 1
XSR(config)#ip firewall filter allowICMP private ANY_EXTERNAL protocol-id 1
XSR(config)#ip firewall filter allowICMP ANY_EXTERNAL dmz protocol-id 1
Trial load the completed configuration into the firewall engine, and if successful, load the
configuration:
XSR(config)#ip firewall load trial
XSR(config)#ip firewall load
Complete LAN and WAN interface configuration:
XSR(config)#interface gigabitethernet 1
XSR(config-if<F1>)#ip address 220.150.2.35/24
XSR(config-if<F1>)#no shutdown
XSR(config)#interface gigabitethernet 2
XSR(config-if<F2>)#ip address 220.150.2.17/24
XSR(config-if<F2>)#no shutdown
XSR(config)#interface serial 1/0:0
XSR(config-if<S1/0:0>)#ip address 206.12.44.16/24
XSR(config-if<S1/0:0>)#no shutdown
Globally enable the firewall. Even though you have configured and loaded the firewall, only
invoking the following command “turns on” the firewall. Once enabled, if you are remotely
connected, the firewall will close your session. Simply login again.
XSR(config)#ip firewall enable
For more Firewall configuration examples, refer to the XSR User’s Guide.
Setting Up RIP Routing
The following commands configure a GigabitEthernet and Serial interface to support RIP with
additional functionality as an option:
3-14
1.
Enter interface gigabitethernet <1 | 2 | 3> to acquire Interface mode and select one of the
GigabitEthernet ports.
2.
Enter ip address <xxx.xxx.xxx.xxx> <yyy.yyy.yyy.yyy> where x is the IP address and y is the
subnet mask of this GigabitEthernet port.
3.
Enter no shutdown to keep the interface enabled.
4.
Enter interface serial <slot # | card # | port #> of the serial NIM card to re-acquire Interface
mode and select slot, card and port numbers.
5.
Enter ip address <xxx.xxx.xxx.xxx> <yyy.yyy.yyy.yyy> where x is the IP address and y is the
subnet mask of the serial port.
6.
Enter ip rip authentication mode text if you want to set clear-text authentication. If you enter
this command, continue with the Step 7, otherwise, go to Step 8.
7.
Enter ip rip authentication key-string <text> to specify a text string for authentication.
8.
Enter no shutdown to keep the interface enabled.
9.
Enter ip rip send version <1 | 2> to allow the RIP version of update transmissions. Version 1
is the default value.
Software Configuration
Configure OSPF Routing
10. Enter ip rip receive version <1 | 2> to allow a RIP version of updated transmissions. Accept
both RIP V1 and V2 is the default value.
11. Enter router rip to acquire Router configuration mode and enable RIP routing.
12. Enter network <xxx.xxx.xxx.xxx> (IP address) of the network to be advertised. Repeat the
command to configure additional networks.
13. Enter passive-interface type num if you want to prevent RIP transmissions on the interface.
14. Enter no receive-interface if you want to disable reception of RIP updates on the interface.
Remember to save your configuration after all edits. For more RIP configuration examples,
refer to the XSR User’s Manual.
Configure OSPF Routing
The following OSPF configuration adds two networks to OSPF areas and sets the cost of sending
traffic on the serial interface:
1.
Enter interface gigabitethernet <1 | 2 | 3> to acquire Interface mode and select one of the
GigabitEthernet ports.
2.
Enter ip address <xxx.xxx.xxx.xxx> <yyy.yyy.yyy.yyy> where x is the IP address and y is the
subnet mask of this GigabitEthernet port.
3.
Enter no shutdown to keep the interface enabled.
4.
Enter interface serial <slot # | card # | port #> of the serial NIM card to re-acquire Interface
mode and select slot, card and port numbers.
5.
Enter ip address <xxx.xxx.xxx.xxx> <yyy.yyy.yyy.yyy> where x is the IP address and y is the
subnet mask of the serial port.
6.
Enter no shutdown to keep the interface enabled.
7.
Enter encapsulation ppp to set the correct encapsulation type.
8.
Enter ip ospf cost <1-65535> to set the cost of receiving a packet on this interface.
9.
Enter router ospf to acquire Router configuration mode and enable OSPF routing.
10. Enter network <xxx.xxx.xxx.xxx> area <area-id> of the network to be advertised. Repeat the
command to configure additional networks.
Remember to save your configuration after all edits. For more OSPF configuration examples,
refer to the XSR User’s Manual.
Configuring Frame Relay Point to Point Networks
The following Frame Relay configuration sets up point-to-point networks on Central and Branch
XSRs. On the Central XSR, perform these steps:
1.
Enter interface serial <slot # | card # | port #> of the serial NIM card to acquire Interface mode
and select a slot, card and port number.
2.
Enter encapsulation frame-relay to set the encapsulation type.
3.
Enter no shutdown to keep the interface enabled.
4.
Enter frame-relay lmi-type <ilmi | ansi | q933a | auto | none> to manually select the Link
Management Interface protocol type to use on the port or retain the default type auto.
XSR Getting Started Guide
3-15
Setting Up an SNMP Community String, Traps and V3 Values
5.
Enter media-type V35 to match the correct cabling interface. The default media type for Frame
Relay is RS-232.
6.
Enter frame-relay traffic-shaping to enable congestion control.
7.
Enter map-class frame-relay <name> to designate this map-class and acquire Map-Class
mode.
8.
Enter frame-relay cir out <bits> to set the outgoing CIR (the default is 56000 bps). Refer to the
XSR User’s Guide for more details.
9.
Enter frame-relay bc out <bits> to set the Burst size for this map-class. Refer to the XSR User’s
Manual for further directions.
10. Enter frame-relay be out <rate> to set the excess Burst site for this map-class. Refer to the XSR
User’s Manual for more directions.
11. Enter interface serial <slot # | card # | port # | subinterface#> <point> of the serial NIM card to
acquire Sub-interface mode, select the point-to-point connection type and begin configuring
this sub-interface.
12. Enter no shutdown to enable the sub-interface.
13. Enter ip address <xxx.xxx.xxx.xxx> <yyy.yyy.yyy.yyy> where x is the IP address and y is the
subnet mask of this sub-interface.
14. Enter frame-relay interface-dlci <16 - 1007> to assign a Data-link Connection Identifier
(DLCI) to this sub-interface. DLCIs are provisioned by your service provider.
15. Enter class <name> to designate the map-class which will be assigned to the earlier specified
DLCI. The class name often refers to the speed of the connection such as SlowLink for a 64000
bps link.
16. Repeat the previous steps on the Branch XSR.
Remember to save your configuration after all edits. Refer to the XSR User’s Guide for more
information.
Setting Up an SNMP Community String, Traps and V3 Values
1.
Enter snmp-server community <string> <ro | rw> <ACL #> to create an SNMP community
with an optional ACL. Although SNMP is disabled by default, entering any SNMP
configuration command except snmp-server disable will enable the SNMP server.
You can choose either Read Only or Read/Write privileges and can create read-only or readwrite community strings. Also, community-based write access is available for the ct-download
MIB only. For write access to other MIBs, use SNMPv3. Also, a RW community is unnecessary
for SNMPv3.
Note: Only standard ACLs can be applied to SNMP configuration commands.
3-16
2.
Enter snmp-server host <IP address> traps <community-string [snmp]> to specify where traps
are sent.
3.
Enter snmp-server location <location-string> to specify where the SNMP device is sited.
4.
Enter snmp-server enable traps snmp authentication to define which traps are sent.
Software Configuration
Configuring Message Logging and Severity Level
5.
Optional . For SNMPv3, enter snmp-server group <name> v3 {auth | nonauth | priv} read
<name> write <name> to add a group.
Groups offer users authorization choices and read/write privileges.
Note: Because only one operator can set the XSR at any time, you must exit Global mode to
perform SNMPv3 configuration. Otherwise, the SNMP set request will fail with the “resource
unavailable” message. This rule applies to configuration values, not image downloads.
6.
Optional. For SNMPv3, enter snmp-server view <name> {oid-tree | treeEntryName}{included |
excluded} to specify a view.
7.
Views offer users selective access to the family tree or Object IDs.
8.
Optional. For SNMPv3, enter snmp-server user <username> <group name> v3
[encrypted][auth {md5 | sha} auth-password [priv des56 priv-password]]} to add a user.
Users can have different levels of encryption and passwords.
Remember to save your configuration after all edits. Refer to the User’s Guide and CLI Reference
Guide for more information.
Note: To restart the XSR using NetSight or SNMP management programs, you must enter the
snmp-server system-shutdown command.
Configuring Message Logging and Severity Level
1.
Enter logging <console | buffer | monitor | snmp | A.B.C.D | file> <high | medium | low |
debug> to direct where error messages are sent and what degree of severity they will reflect.
Messages stored to buffer are saved to the XSR’s RAM, those stored to monitor are displayed on
active Telnet CLI sessions, those stored to A.B.C.D. are saved in the IP address of the
associated SYSLOG server. Refer to the XSR CLI Reference and User Guide for more
information about severity levels.
Typically, only HIGH severity alarms are logged to red flag critical events and those requiring
operator intervention. Also, the DEBUG alarm level is meant for maintenance personnel only.
The XSR may discard LOW and DEBUG level alarms if the system is too occupied to deliver
them. The number of discarded messages is displayed by the following line in show logging
command output:
Discards: high=0 medium=0 low=4 debug=22
2.
Enter show logging to verify the logging configuration.
When the XSR has been up and running for a while more data will be shown in this display.
For a detailed list of most alarms and events generated by the router, refer to the XSR User
Guide.
Remember to save your configuration after all edits.
XSR Getting Started Guide
3-17
Viewing Your Configuration
Viewing Your Configuration
1.
Enter show running-config to verify your current configuration.
The XSR will display the commands you issued up to this point. Default values are not
displayed.
Note: All show commands can be entered in privileged EXEC mode - XSR# - or Global
configuration mode - XSR(config)#.
Connecting Remotely via the Web
1.
Enter configure to acquire Configuration mode.
2.
Enter ip http server enable to access the XSR over the Web.
3.
Point your terminal’s Web browser at the XSR’s IP address. Enter http://<XSR IP address>.
The initial Web access window appears as shown in Figure 3-2.
Figure 3-2
Initial Web Access Window
STATUS
* Product Version
* X-Pedition Products
X-Pedition Security Router XSR
© 2004 Enterasys Networks. All rights
3-18
Software Configuration
Connecting Remotely via the Web
Click on Product Version to bring up the Product Version window for a host of hardware,
bootrom, and software information as shown in Figure 3-3.
Figure 3-3
Web Product Version Window
Product Version
Copyright 2004 by Enterasys Networks, Inc.
Hardware:
Processor board ID: 9002854-02 REV0A
Serial Number: (not displayed)
Processor: IBM PowerPC 405GP Rev. D at 250MHz
RAM installed: 64MB
Flash installed: 8MB on processor board
CompactFlash not present
Real Time Clock
GigabitEthernet 1
GigabitEthernet 2 Rev 0
H/W Encryption Accelerator Rev 1
Empty NIM slot 1
T1E1 has 4 channelized ports in NIM 2 slot
Empty internal NIM slot 3
X-pedition Security Router XSR-3150
© 2004 Enterasys Networks. All rights reserved.
XSR Getting Started Guide
3-19
LAN-PPP Services Sample Configuration
LAN-PPP Services Sample Configuration
The sample configuration below, see Figure 3-4, creates a PPP, fractional T1 leased line connection
from the XSR branch node to the Central Site router and a backup serial dialup link to the Backup
Site regional router.
Figure 3-4
Hostname:
Username:
Password:
Sample LAN-PPP Services Configuration
branch1
mainsite
Toronto
Hostname:
Username:
Password:
mainsite
branch1
Toronto
192.168.1.100/24
XSR-3150
154.168.1.47/24
PPP
Leased line
fractional E1/T1
PSTN
Central Site
PPP
Leased line
or E1/T1
serial V.35/X.21
XSR-3150
or
SSR-8600
2
1-800-555-1111
Username: branch2
Password: Ontario
Backup via serial
(RS-232 dial)
PSTN
154.168.1.1/24
Backup Site
Dial serial
or PRI
XSR-3150
Hostname: branch2
Username: branch1
Password: Ontario
The following script configures the LAN-PPP services topology shown above.
XSR>enable
+ Acquires Privileged EXEC mode
XSR#configure
+ Acquires Global configuration mode
XSR(config)#hostname branch1
+ Configures the local hostname
XSR(config)#username mainsite password secret 0 Toronto
+ Configures first username and password for CHAP
XSR(config)#username branch2 password secret 0 Ontario
+ Configures second username and encrypted password for CHAP
XSR(config)#interface gigabitethernet 1
+ Configures local LAN interface and acquires Interface mode
XSR(config-if<G1>)#ip address 192.168.1.100 255.255.255.0
+ Enables IP address for GigabitEthernet interface
XSR(config-if<G1>)#no shutdown
+ Enables the interface
XSR(config)#controller t1 0/1/0
+ Sets up main link connection: T1 NIM in slot 1, port 0 and acquires Controller mode
XSR(config-controller<T1-1/0>)#clock source line
+ Sets external clocking of T1 NIM
XSR(config-controller<T1-1/0>)#no channel-group 0
+ Deletes default channel setup
XSR(config-controller<T1-1/0>)#channel 0 timeslot 1-4,7,9-15
+ Adds channel group 0 mapping to time slots 1-4, 7, and 9-15
XSR(config-controller<T1-1/0>)#framing esf
+ Begins configuring T1 channel values: sets T1 line frame type
XSR(config-controller<T1-1/0>)#linecode b8zs
+ Sets T1 encoding
3-20
Software Configuration
Server
LAN-PPP Services Sample Configuration
XSR(config-controller<T1-1/0>)#no shutdown
+ Enables T1 controller
XSR(config)#interface serial 1/0:0
+ Configures Serial interface 1, port 1 using channel group 0 and acquires Interface mode
XSR(config-if<S1/0:0>)#encapsulation ppp
+ Enables PPP encapsulation
XSR(config-if<S1/0:0>)#ppp authentication chap
+ Configures CHAP authentication on the interface
XSR(config-if<S1/0:0>)#ip address 154.68.1.47 255.255.255.0
+ Enables IP address for serial interface 1/0
XSR(config-if<S1/0:0>)#backup interface dialer 5
+ Sets dialed interface as a dialed backup
XSR(config-if<S1/0:0>)#no shutdown
+ Enables the interface
XSR(config)#router rip
+ Enables RIP routing and goes to Router mode
XSR(config-router)#network 192.168.1.100
+ Configures a network RIP will advertise its routes to
XSR(config-router)#network 154.68.1.0
+ Configures a second network RIP will advertise its routes to
XSR(config-router)#network 164.55.7.0
+ Configures a third network RIP will advertise its routes to
XSR(config)#interface dialer 5
+ Adds backup interface and acquires Interface mode
XSR(config-if<D5>)#diaer pool 3
+ Adds a dialer pool on interface
XSR(config-if<D5>)#dialer string 18005555555
+ Sets backup phone #
XSR(config-if<D5>)#encapsulation ppp
+ Enables PPP encapsulation on port
XSR(config-if<D5>)#ppp authentication chap
+ Sets CHAP on port
XSR(config-if<D5>)#ip address 164.55.7.22 255.255.255.0
+ Enables the IP address for dialer interface 5
XSR(config-if<D5>)#no shutdown
+ Enables the interface
XSR(config)#interface serial 2/0
+ Configures backup interface: Serial card in slot 2, port 0 and acquires Interface mode
XSR(config-if<S2/0>)#dialer pool-member 3
+ Adds a dial pool
XSR(config-if<S2/0>)#physical-layer sync
+ Sets synchronous mode
XSR(config-if<S2/0>)#no shutdown
+ Enables the interface
XSR Getting Started Guide
3-21
Frame Relay WAN Link with PPP Backup Sample Configuration
Frame Relay WAN Link with PPP Backup Sample Configuration
The sample configuration below, similar to the preceding configuration except that the cloud
supporting the primary line is Frame Relay rather than Public Service Telephone Network,
configures one LAN port, the Frame Relay WAN, QoS, OSPF routing, DHCP Relay, IP broadcast
forwarding, SNMP with ACL rules, and access lists.
Configure Users and Passwords
XSR>enable
+ Acquires Privileged EXEC mode
XSR#configure
+ Acquires Global configuration mode
XSR(config)#username bob password cleartext bobspassword
+ Adds a user and unencrypted password
Configure LAN Interface
XSR(config)#interface gigabitethernet 1
+ Configures the local LAN port and acquires Interface mode
XSR(config-if<G1>)#ip address 192.168.1.100 255.255.255.0
+ Enables the IP address for the GigabitEthernet port
XSR(config-if<F1>)#no shutdown
+ Enables the interface
Configure Quality of Service
XSR(config)#access-list 129 permit udp 192.168.1.0 0.0.0.255 any eq 554
+Adds a UDP filter matching the source network and any destination address to port 554
XSR(config)#access-list 129 permit tcp 192.168.1.0 0.0.0.255 any eq 554
+Adds a TCP filter matching the source network and any destination address to port 554
XSR(config)#access-list 130 permit ip any host 192.168.2.75
+ Adds an IP filter matching any source address to the specified destination address
XSR(config)#access-list 131 permit tcp any any eq 20
+ Adds a TCP filter which matches any source address and destination address to port 20
XSR(config)#access-list 132 permit tcp any any eq 21
+ Adds a TCP filter which matches any source and destination address to port 21
XSR(config)#access-list 133 permit tcp any any eq 80
+ Adds a TCP filter which matches any source and destination address to port 80
XSR(config)#class-map rtp-class
+ Adds a class-map and acquires Class Map mode
XSR(config-cmap<rtp-class>)#match access-group 129
+ Assigns ACL 129 to this class map
XSR(config)#class-map priority-server
+ Adds a class-map and acquires Class Map mode
XSR(config-cmap<priority-server>)#match access-group 130
+ Assigns ACL 130 to this class map
XSR(config)#class-map match-any data_class
+ Adds a class-map and acquires Class Map mode
XSR(config-cmap<data_class>)#match access-group 131
+ Assigns ACL 131 to this class map
XSR(config-cmap<data_class>)#match access-group 132
+ Assigns ACL 132 to this class map
3-22
Software Configuration
Frame Relay WAN Link with PPP Backup Sample Configuration
XSR(config-cmap<data_class>)#match access-group 133
+ Assigns ACL 133 to this class map
XSR(config)#policy-map priority-policy
+ Adds a policy map and acquires Policy Map mode
XSR(config-pmap<priority-policy>)#class rtp_class
+ Adds a queue for this policy map and acquires Class sub-mode
XSR(config-pmap-c<priority-policy>)#priority high 30 3200
+ Gives high priority queue a peak 30% of bandwidth and a burst size of 3200 bits per second
XSR(config-pmap-c<priority-policy>)#set ip dscp ef
+ Configures IP precedence to match packets with Expedited Forwarding
XSR(config-pmap<priority-policy>)#class priority-server
+ Adds another queue for this policy map and enters Class sub-mode
XSR(config-pmap-c<priority-server>)#priority medium 20 6400
+ Gives medium priority queue peak 20% of bandwidth and burst size of 6400 bits per second
XSR(config)#policy-map data_policy
+ Adds a policy map and acquires Policy Map mode
XSR(config-pmap<data_policy>)#class data_class
+ Adds a queue for this policy map and acquires Class sub-mode
XSR(config-pmap-c<data_class>)#police 24000 2400 4800 conform-action transmit
exceed-action set-dscp-transmit 23 violate-action drop
+ Sets traffic policing at an average rate of 24000 bits per second, a normal burst size of 2400 bits per second, and an excess
burst size of 4800 bits per second. Packets conforming to values are sent, those exceeding are set to a DSCP value of 23
and those violating values are dropped.
XSR(config-pmap-c<data_class>)#bandwidth percent 50
+ Gives the class a minimum 50% of the bandwidth
Configure WAN/Frame Relay Port
This port’s IP address is 154.68.1.47. The attached switch operates at 128,000 bps, with auto LMI
type, and traffic shaping enabled. Any QoS values set will be applied to the DLCIs: do not apply
QoS to the port, it is not recommended on Frame Relay connections. Note that some commands
are abbreviated.
XSR(config)#interface serial 1/0
+ Configures Frame Relay interface: Serial card in slot 1, port 0 and acquires Interface mode
XSR(config-if<S1/0>)#media-type v35
+ Selects type for Frame Relay
XSR(config-if<S1/0>)#no shutdown
+ Enables the interface
XSR(config-if<S1/0>)#encapsulation frame-relay
+ Enables FR encapsulation
XSR(config-if<S1/0>)#frame-relay class CLASS-FRP
+ Adds a FR map class
XSR(config-if<S1/0>)#frame-relay traffic-shaping
+ Enables map class values
XSR(config)#interface serial 1/0.1 multipoint
+ Adds FR port: serial card in slot 1, port 0, sub-interface 1 for multipoint connections and acquires Interface mode
XSR(config-if<S1/0.1>)#frame-relay interface-dlci 33
+ Adds PVC #33
XSR(config-if<S1/0.1-33>)#no shutdown
+ Enables the DLCI port
XSR(config-if<S1/0.1-33>)#ip address 154.68.1.47 255.255.255.0
+ Configures the IP address of the port
XSR Getting Started Guide
3-23
Frame Relay WAN Link with PPP Backup Sample Configuration
XSR(config)#interface serial 1/0.2 multipoint
+ Configures FR port: Serial card in slot 1, port 0, sub-interface 2 for multipoint links and acquires Interface mode
XSR(config-if<S1/0.2>)#frame-relay class CLASS_SI
+ Adds another FR map class
XSR(config-if<S1/0.2>)#frame-relay interface-dlci 16
+ Adds PVC #16 and acquires DLCI 16 sub-mode
XSR(config-if<S1/0.2-16>)#class CLASS_DLCI
+ Assigns the specified map class to DLCI 16
XSR(config-if<S1/0.2-16>)#ip address 154.68.2.1 255.255.255.0
+ Configures the IP address of DLCI 16
XSR(config-if<S1/0.2-16>)#no shutdown
+ Enables DLCI 16 interface
Apply QoS
XSR(config)#map-class frame-relay CLASS-FRP
+ Adds a FR map class and acquires FR Map Class mode
XSR(config-map-class<CLASS-FRP>)#frame-relay cir out 48000
+ Sets this map class’ CIR rate at 48000 bits per second
XSR(config-map-class<CLASS-FRP>)#frame-relay bc out 4000
+ Sets this map class’ committed burst size to 4000 bits
XSR(config-map-class<CLASS-FRP>)#frame-relay be out 3000
+ Sets this map class’ excess burst size to 3000 bits
XSR(config-map-class<CLASS-FRP>)#frame-relay adaptive-shaping
+ Enables BECN (traffic shaping) for this map class
XSR(config-map-class<CLASS-FRP>)#service-policy output data_policy
+ Attaches this policy to the map class
XSR(config)#map-class frame-relay CLASS-SI
+ Adds another FR map class and acquires Frame Relay Map Class mode
XSR(config-map-class<CLASS-SI>)#frame-relay cir out 30000
+ Sets this map class’ CIR rate at 30,000 bits per second
XSR(config-map-class<CLASS-SI>)#frame-relay bc out 5000
+ Sets this map class’ committed burst size to 5000 bits
XSR(config-map-class<CLASS-SI>)#frame-relay be out 3000
+ Sets this map class’ excess burst size to 3000 bits
XSR(config-map-class<CLASS-SI>)#frame-relay adaptive-shaping
+ Enables BECN (traffic shaping) for this map class
Router(config-map-class<CLASS-SI>)#service-policy HighOutput
+ Attaches this policy to the map class
XSR(config)#map-class frame-relay CLASS-DLCI
+ Adds another Frame Relay map class and acquires Frame Relay Map Class mode
XSR(config-map-class<CLASS-DLCI>)#frame-relay cir out 50000
+ Sets this map class’ CIR rate at 50,000 bits per second
XSR(config-map-class<CLASS-DLCI>)#frame-relay bc out 4000
+ Sets this map class’ committed burst size to 4000 bits
XSR(config-map-class<CLASS-DLCI>)#frame-relay be out 1000
+ Sets this map class’ excess burst size to 1000 bits
XSR(config-map-class<CLASS-DLCI>)#frame-relay adaptive-shaping
+ Enables BECN (traffic shaping) for this map class
XSR(config-map-class<CLASS-DLCI>)#service-policy output priority-policy
+ Attaches this policy to the map class
3-24
Software Configuration
Frame Relay WAN Link with PPP Backup Sample Configuration
Configure OSPF Routing
XSR(config)#router ospf 1
+ Enables OSPF with a router ID and acquires Router mode
XSR(config-router)#network 192.168.1.0 0.0.0.255 area 0.0.0.10
+ Configures the area ID for the specified network
XSR(config-router)#network 154.68.1.0 0.0.0.255 area 0.0.0.0
+ Configures another area ID for the specified network
Configure More Access Lists
The following ACLs deny any packets to or from network 192.168.1.15 as they enter or leave
FastEthernet 1 interface, and permit traffic to or from subnet 192.168.2.xx while denying any other
traffic.
XSR(config)#access-list 125 deny ip any host 192.168.1.15
XSR(config)#access-list 125 deny ip host 192.168.1.15 any
XSR(config)#access-list 125 permit ip 192.162.2.0 0.0.0.255 any
XSR(config)#access-list 125 permit ip 192.162.2.0 0.0.0.255
XSR(config)#interface fastethernet 1
XSR(config-if<F1>)#ip access-group 125 in
XSR(config-if<F1>)#ip access-group 125 out
Configure DHCP/BOOTP Relay
XSR(config)#interface gigabitethernet 1
+ Adds GigabitEthernet port 1 and acquires Interface mode
XSR(config-if<G1>#ip helper-address 192.168.1.120
+ Marks destination IP address for UDP broadcasts
Configure the Dial Backup Connection
XSR(config)#interface ser 1/0
+ Adds serial port 1 and acquires Interface mode
XSR(config-if<S1/0>)#encapsulation ppp
+ Enables PPP encapsulation
XSR(config-if<S1/0>)#ip address 192.31.27.80 255.255.255.0
+ Sets the IP address on the interface
XSR(config-if<S1/0>)#backup int dialer 1
+ Adds a backup dialer interface
XSR(config-if<S1/0>)#backup delay 2 2
+ Sets the interval that elapses after the primary interfaces fails and comes up
XSR(config-if<S1/0>)#no shutdown
+Enables the interface
XSR(config)#interface serial 2/0
+ Adds serial port 2 and acquires Interface mode
XSR(config-if<S2/0>)#dialer pool-member 1
+ Adds a dial pool member
XSR(config-if<S2/0>)#physical-layer sync
+ Sets synchronous mode
XSR(config-if<S2/0>)#no shutdown
+ Enables the interface
XSR(config)#int dialer 1
+ Adds dialer interface and acquires Dialer Interface mode
XSR Getting Started Guide
3-25
Frame Relay WAN Link with PPP Backup Sample Configuration
XSR(config-if<D1>)#encapsulation ppp
+ Enables PPP encapsulation
XSR(config-if<D1>)#ip address 192.31.27.84 255.255.255.0
+ Sets the IP address on the interface
XSR(config-if<D1>)#dialer string 4165557922
+ Sets dialer phone #
XSR(config-if<D1>)#dialer wait-for-carrier 30
+ Specifies the period the XSR will wait for a connection from the service provider
XSR(config-if<D1>)#di pool 1
+ Specifies the dial pool from which calls originate
XSR(config-if<D1>)#no shutdown
+ Enables the dial interface
Configure SNMP
The previously configured ACL will be applied to all SNMP requests. Stricter ACLs can be written
if tighter security controls are required.
XSR(config)#snmp-server community toMonitor1 ro 26
+ Adds an SNMP community with read-only privileges attached to ACL 26
XSR(config)#snmp-server community toConfigure1 rw 26
+ Adds another SNMP community with read-write privileges attached to ACL 26
XSR(config)#snmp-server enable traps
+ Enables traps to be transmitted
XSR(config)#snmp-server contact [email protected]
+ Specifies contact information for the management server
XSR(config)#snmp location “HQ 2nd floor”
+ Specifies the server locationr
XSR(config)#snmp-server host 192.168.2.101 traps trapCommunity
+ Specifies management station to send traps to
XSR(config)#snmp-server host 192.168.2.102 traps trapCommunity
+ Specifies another management station to send traps to
3-26
Software Configuration
VPN Site-to-Site Sample Configuration
VPN Site-to-Site Sample Configuration
The following VPN topology, shown in Figure 3-5, configures a central site XSR to connect over
IPSec tunnels with a remote ANG-1105 and two XSRs.
Figure 3-5
VPN Site-to-Site Topology
112.16.72.2
Central Site
112.16.244.9
ANG-1105
112.16.1.221
Branch Sites
XSR
SECU
RITY
XSR
ROUT
ERS
-185
0
112.16.76.2
10/10
POW
ER
0BT
SYS
ACT
VPN
10/10
0BT
ACT
ETHE
RNET
PORT
1
ETHE
RNET
PORT
2
CON
SOLE
NIM
1
NIM
2
SECUR
ITY
ROUTE
XSR-
1850
RS
10/100B
POWER
T
SYS
ACT
VPN
ETHERN
PORT ET
1
10/100B
T
ACT
ETHERN
PORT ET
2 CONSO
LE
XSR
Firewall
NIM
1
NIM
2
112.16.244.7
112.16.244.10
Gateway IP address
for all remote sites
XSR
ANG-1105
112.16.80.2
SECUR
ITY
ROUTE
XSR-
1850
RS
10/100B
POWER
T
SYS
ACT
VPN
ETHERN
PORT ET
1
10/100B
T
ACT
ETHERN
PORT ET
2 CONSO
LE
NIM
1
NIM
2
112.16.244.5
The following script configures the VPN topology shown in Figure 3-5.
Generate Master Encryption Key
If you have not already generated a master encryption key, you must do so now to configure th6e
VPN. A master key need only be generated once.
Caution: The master encryption key is stored in hardware, not Flash, and you cannot read the
key - only overwrite the old key by writing a new one. To ensure router security, it is critical not to
compromise the key. There are situations where you may want to keep the key, for example, to
save the user database off-line in order to later download it to the XSR. In order to encrypt the
user database, you need the same master key, indicating the key designation with the master key
specify command. Be aware that if the XSR is inoperable you may have to return to factory
defaults, which erases the master key forcing you to generate a new one.
Generate the master key:
XSR(config)#crypto key master generate
New key is 2173 4521 3764 2ff5
163b 4bdf fe92 dbc1
1232 ffe0 f8d9 3649
Configure Access Control Lists
ACL 101 configured below is strongly restrictive in denying all but IKE traffic (well-known UDP
port# 500) through the router. ACLs 190, 191, and 192 are crypto map filters configured to accept
any IPSec-encrypted traffic over site-to-site tunnels and pass that traffic to the three specified
networks only.
XSR(config)#access-list 101 permit udp any any eq 500
XSR(config)#access-list 101 permit udp esp any any
XSR Getting Started Guide
3-27
VPN Site-to-Site Sample Configuration
XSR(config)#access-list
XSR(config)#access-list
XSR(config)#access-list
XSR(config)#access-list
XSR(config)#access-list
101
101
190
191
192
permit udp ah any any
deny ip any any
permit ip any 112.16.72.0 0.0.0.255
permit ip any 112.16.76.0 0.0.0.255
permit ip any 112.16.80.0 0.0.0.255
Set Up IKE Phase I Security
The following proposal sets pre-shared authentication and MD5 hashing:
XSR(config)#crypto isakmp proposal acme
XSR(config-isakmp)#authentication pre-share
XSR(config-isakmp)#hash md5
Configure IKE Policy for Remote Peer
The following proposal specifies the XSR’s remote peer IP address as any peer matching its IKE
policy, sets NAT to automatically detect routers performing NAT between tunnel endpoints and
directs the XSR to switch on UDP encapsulation when found.
It also designates the peer as a gateway which will initiate the configuration mode in terms of IKE
negotiation:
XSR(config)#crypto isakmp peer 0.0.0.0 0.0.0.0
XSR(config-isakmp-peer)#proposal acme
XSR(config-isakmp-peer)#config-mode gateway
XSR(config-isakmp-peer)#nat-traversal automatic
Create a Transform Set
The following transform-set specifies the specified encryption/data integrity choices, 768-bit
Diffie-Hellman, and an SA lifetime expressed in kilobytes. The SA seconds lifetime value is disabled.
Some commands are abbreviated.
XSR(config)#crypto ipsec tra esp-3des-sha esp-3des esp-sha-hmac
XSR(cfg-crypto-tran)#set pfs group1
XSR(cfg-crypto-tran)#set sec lifetime kilobytes 100000
XSR(cfg-crypto-tran)#no set sec lifetime seconds
Configure Crypto Maps
The following IKE policy crypto maps are each linked to the earlier added transform-set with
matching ACLs and are set by default for the more stringent tunnel mode. Maps 91 and 92 match
the remote XSRs and map 90 correlates with the ANG. Crypto map statements render the
associated ACLs bi-directional.
XSR(config)#crypto map acme 92
XSR(config-crypto-m)#set transform-set esp-3des-sha
XSR(config-crypto-m)#match address 192
XSR(config-crypto-m)#set peer 112.16.244.5
3-28
Software Configuration
VPN Site-to-Site Sample Configuration
XSR(config)#crypto map acme 91
XSR(config-crypto-m)#set transform-set esp-3des-sha
XSR(config-crypto-m)#match address 191
XSR(config-crypto-m)#set peer 112.16.244.7
XSR(config)#crypto map acme 90
XSR(config-crypto-m)#set transform-set esp-3des-sha
XSR(config-crypto-m)#match address 190
XSR(config-crypto-m)#set peer 112.16.244.9
Configuring VPN at Interface Mode and Setting Up RIP
The following commands configure the LAN physical ports as follows: GigabitEthernet port 1 is
designated Internal LAN, with the specified IP address/subnet as the designated network.
GigabitEthernet port 2 is named VPN Cloud, assigned crypto map acme with associated ACLs, and
directed not to transmit or receive RIP updates. Also, RIP routing and four IP routes are
configured as well as a VPN interface for AAA service.
XSR(config)#interface gigabitethernet 1
XSR(config-if<F1>)#description “Internal LAN”
XSR(config-if<F1>)#no shutdown
XSR(config-if<F1>)#ip address 112.16.1.221/24
XSR(config)#interface gigabitethernet 2
XSR(config-if<F2>)#crypto map acme
XSR(config-if<F2>)#description “VPN Cloud”
XSR(config-if<F2>)#no shutdown
XSR(config-if<F2>)#ip access-group 101 in
XSR(config-if<F2>)#ip access-group 101 out
XSR(config-if<F2>)#ip address 112.16.244.10/24
XSR(config)#interface vpn 57 multi-point
XSR(config-int-vpn)#ip address 192.168.2.1 255.255.255.0
XSR(config)#router rip
XSR(config-router)#network 112.16.10.0
XSR(config-router)#passive-interface gigabitethernet 2
XSR(config-router)#no receive-interface gigabitethernet 2
XSR(config-router)#distribute-list 1 out vpn 1
XSR(config)#ip
XSR(config)#ip
XSR(config)#ip
XSR(config)#ip
route
route
route
route
0.0.0.0 0.0.0.0 112.16.244.9
112.16.72.0/24 112.16.244.9
112.16.76.0/24 112.16.244.7
112.16.80.0/24 112.16.244.5
XSR Getting Started Guide
3-29
VPN Sample Configuration with Network Extension Mode
Configuring Authentication (AAA)
Configure an AAA user and DEFAULT AAA group for remote users. When an ANG tunnels into
the XSR, it will be assigned dynamically to the IP pool AUTH. Be aware that groups must be
created before users can be added to them. Remember to create the same users and passwords on
the ANG. The IP address assigned to the AAA user is the remote gatewayIP address.
XSR(config)#ip local pool AUTH 192.168.2.0 255.255.255.0
XSR(config)#aaa user 112.16.244.9
XSR(aaa-user)#password dribble
XSR(aaa-user)#group DEFAULT
XSR(aaa-group)#pptp encrypt mppe auto
XSR(aaa-group)#ip pool AUTH
XSR(aaa-group)#policy vpn
VPN Sample Configuration with Network Extension Mode
The following sample topology is ideal for testing a VPN NEM tunnel connection on a LAN before
actually configuring a production network. If the configuration works properly, simply change
the GigabitEthernet settings to the Serial or T1 interface values of your choice.
The XSR below is configured as a VPN concentrator with Internet access allowed and Network
Extension Mode (NEM) tunnels set up. NEM is designed to open up network resources situated
behind the XSR. You configure NEM to provide routing for nodes connected to the trusted port of
the router so that locally and remotely connected devices can discover and communicate with
each other across an IKE/IPSec tunnel.
The XSR’s EZ-IPSec functionality is employed to automatically access default ESP transforms and
IPSec proposals.
Figure 3-6
VPN Topology with NEM, EZ-IPSec and Internet Access
GigabitEthernet 1: 172.16.10/24
GigabitEthernet 2: 26.26.26.10/24
Virtual IP Pool: 172.16.10.0/24
eth0: 10.11.11.1/24
eth1: 26.26.26.11/24
SECURI
TY
ROUTER
XSR-1
850
S
10/100BT
POWER
SYS
ACT
VPN
ETHERN
PORT ET
1
10/100BT
ACT
ETHERN
PORT ET
2 CONSOL
E
SECU
RITY
XSR
ROUT
ERS
-185
0
26.26.26.0/24
10/10
POW
ER
0BT
SYS
ACT
VPN
10/10
0BT
ACT
ETHE
RNET
PORT
1
ETHE
RNET
PORT
2
CON
SOLE
NIM
1
NIM
2
XSR
NIM
1
NIM
2
XSR
eth0: 10.12.12.1/24
eth1: 26.26.26.12/24
SECURI
TY
ROUTER
XSR-1
850
S
10/100BT
POWER
172.16.10.0
SYS
ACT
VPN
ETHERN
PORT ET
1
10/100BT
ACT
ETHERN
PORT ET
2 CONSOL
E
NIM
1
NIM
2
XSR
The following script configures the VPN topology shown in Figure 3-6.
If you have not already generated a master encryption key, you must do so now to configure the
VPN. A master key need only be generated once.
Caution: The master encryption key is stored in hardware, not Flash, and you cannot read the
key - only overwrite the old key by writing a new one. To ensure router security, it is critical not to
compromise the key. There are situations where you may want to keep the key, for example, to
save the user database off-line in order to later download it to the XSR. In order to encrypt the
user database, you need the same master key, indicating the key designation with the master key
specify command. Be aware that if the XSR is inoperable you may have to return to factory
defaults, which erases the master key forcing you to generate a new one.
3-30
Software Configuration
VPN Sample Configuration with Network Extension Mode
Generate the master key. Refer to the following sample key:
XSR(config)#crypto key master generate
New key is 2173 4521 3764 2ff5
163b 4bdf fe92 dbc1
1232 ffe0 f8d9 3649
Apply the following ACLs to the public interface of the XSR before creating the VPN
configuration. These ACLs are applied only to an XSR configured to terminate Network Extension
Mode (NEM) tunnels initiated from ANG-1100s. These ACLs allow all outbound IP traffic and
established inbound TCP traffic and employ well-known protocol numbers for IKE UDP (500) and
ICMP to and from the public interface (if preferred).
XSR(config)#access-list
XSR(config)#access-list
XSR(config)#access-list
XSR(config)#access-list
XSR(config)#access-list
1 deny 26.26.26.0 0.0.0.255
1 permit any
110 permit udp any any eq 500
110 permit icmp any host 26.26.26.10
110 deny ip any any
XSR(config)#access-list 111 permit udp any any eq 500
XSR(config)#access-list 111 permit icmp host 26.26.26.10 any
XSR(config)#access-list 111 deny ip any any
XSR(config)#interface gigabitethernet 2
XSR(config-if<F2>)#ip access-group 110 in
XSR(config-if<F2>)#ip access-group 111 out
Enable Network Address Translation:
XSR(config-if<F2>)#ip nat source assigned overload
Create the VPN virtual subnet:
XSR(config)#ip local pool virtual_subnet 10.10.10.0 255.255.255.248
Configure AAA authentication by assigning a virtual subnet to the DEFAULT AAA group,
associate it with DNS and WINs servers, and add two AAA users with passwords.
When a remote XSR tunnels into the local XSR, it will be assigned these DNS, WINS and PPTP
values and be assigned dynamically to the IP pool virtual_subnet. Be aware that users not added to
a specified group will automatically be assigned to the DEFAULT group and groups must be
created before users can be added to them. Remember to create the same users and passwords on
the remote XSRs.
XSR(ip-local-pool)#aaa group DEFAULT
XSR(aaa-group)#ip pool virtual_subnet
Configure DNS and WINS parameters:
XSR(aaa-group)#dns server primary 172.16.10.10
XSR(aaa-group)#dns server secondary 172.16.10.11
XSR(aaa-group)#wins server primary 172.16.10.10
XSR(aaa-group)#wins server secondary 172.16.10.11
XSR Getting Started Guide
3-31
VPN Sample Configuration with Network Extension Mode
Create user(s), specify an IP from virtual subnet, and assign a password:
XSR(config)#aaa user
XSR(config)#password
XSR(config)#aaa user
XSR(config)#password
nem-test
welcome
jeffb
welcome
Check to make sure the transforms and proposals were created properly:
XSR#show crypto ipsec transform-set
Name
PFS
-----*ez-esp-3des-sha-pfs
Modp768
*ez-esp-3des-sha-no-pfs
Disabled
*ez-esp-3des-md5-pfs
Modp768
*ez-esp-3des-md5-no-pfs
Disabled
*ez-esp-aes-sha-pfs
Modp768
*ez-esp-aes-sha-no-pfs
Disabled
*ez-esp-aes-md5-pfs
Modp768
*ez-esp-aes-md5-no-pfs
Disabled
ESP
--3DES
3DES
3DES
3DES
AES
AES
AES
AES
XSR#show crypto isakmp proposal
Name
Authentication
----------------*ez-ike-3des-sha-psk PreSharedKeys
*ez-ike-3des-md5-psk PreSharedKeys
*ez-ike-3des-sha-rsa RSASignature
*ez-ike-3des-md5-rsa RSASignature
ESP-AH
-----HMAC-SHA
HMAC-SHA
HMAC-MD5
HMAC-MD5
HMAC-SHA
HMAC-SHA
HMAC-MD5
HMAC-MD5
Encrypt
------3DES
3DES
3DES
3DES
AH IPCOMP
-- -----None
None
None
None
None
None
None
None
Integrity
--------HMAC-SHA
HMAC-MD5
HMAC-SHA
HMAC-MD5
Group
----Modp1024
Modp1024
Modp1024
Modp1024
None
None
None
None
None
None
None
None
Lifetime
-------28800
28800
28800
28800
Create the ISAKMP IKE global peer:
XSR#crypto isakmp peer 0.0.0.0 0.0.0.0
XSR#config-mode gateway
XSR#exchange-mode aggressive
XSR#proposal ez-ike-3des-sha-psk ez-ike-3des-md5-psk
Create the ACL for trusted subnet of the XSR and virtual subnet of XSR:
XSR(config)#access-list 101 permit ip any 10.11.11.0 0.0.0.255
XSR(config)#access-list 102 permit ip any 10.12.12.0 0.0.0.255
XSR(config)#access-list 103 permit ip any 10.10.10.0 0.0.0.255
Create crypto map statements for each ACL entry with the more protective tunnel mode set by
default. Match statements render the associated ACLs bi-directional:
XSR(config)#crypto map test 101
XSR(config)#set transform-set ez-esp-3des-sha-pfs
XSR(config)#match address 101
XSR(config)#crypto map test 102
XSR(config)#set transform-set ez-esp-3des-sha-pfs
XSR(config)#match address 102
XSR(config)#crypto map test 103
XSR(config)#set transform-set ez-esp-3des-sha-pfs
XSR(config)#match address 103
3-32
Software Configuration
XSR Rebooting Characteristics
Create the multi-point VPN virtual port required to terminate many clients:
XSR(config)#interface vpn1 multi-point
XSR(config)#description “VPN Virtual Interface Int0”
XSR(config)#ip address 10.10.10.1/24
XSR(config)#ip rip send version 2
XSR(config)#ip rip receive version 2
XSR(config)#ip multicast-redirect tunnel-endpoint
Enable RIP routing on all networks except the public interface:
XSR(config)#router rip
XSR(config)#network 172.16.10.0
XSR(config)#network 10.0.0.0
XSR(config)#passive-interface gigabitethernet2
XSR(config)#no receive-interface gigabitethernet2
XSR(config)#distribute-list 1 out vpn1
Finally, attach the crypto map statement to the public interface:
XSR(config)#interface gigabitethernet 2
XSR(config-if<F2>)#crypto map test
XSR(config-if<F2>)#end
XSR#copy running-config startup-config
XSR Rebooting Characteristics
When the XSR reboots, it conforms to the behavior described in this section. The output displayed
at the CLI describes router initialization.
Initialization Output
The XSR displays the following output when it initializes (cold reboot):
X-Pedition Security Router Bootrom
Copyright 2003 Enterasys Networks Inc.
HW Version: 9002914-04 REV0A Serial Number: 2914024201123206
CPU: Broadcom BCM1250 Rev 2
VxWorks version: VxWorks5.4.2
Bootrom version: 1.5
Creation date: Aug 26 2003, 13:23:16
Warm Start : from cli
Testing Bootrom Integrity << PASSED >>
auto-booting...
Verifying flash:xsr3000.fls file ...
Router S/W size=11989192 sum=0xedd1 compressed_size=4109639 entry=0x80020000
Diagnostics size=1459880 sum=0x8154 compressed_size=614417 entry=0x80020000
RouterCpu1 S/W size=1520104 sum=0x4a2c compressed_size=652528 entry=0x82020000
XSR Getting Started Guide
3-33
XSR Rebooting Characteristics
Testing S/W Integrity << PASSED >>
Loading Router S/W to address 0x80020000
Verifying uncompressed chksum ...
Starting from 0x80020000...
Attaching shared memory objects at 0xa0000600... done
Attaching interface lo0...done
Verifying flash:xsr3000.fls file ...
Router S/W size=11989192 sum=0xedd1 compressed_size=4109639 entry=0x80020000
Diagnostics size=1459880 sum=0x8154 compressed_size=614417 entry=0x80020000
RouterCpu1 S/W size=1520104 sum=0x4a2c compressed_size=652528 entry=0x82020000
Testing S/W Integrity << PASSED >>
Cpu1 software loaded at address 0x82020000, size is 0x001731e8
==cpu1:Running.
******************** REMOTE AUTO INSTALL STARTING *************************
Remote Auto Install Terminating - No Serial Cards Installed
login:
Reboot Triggers
Although there are two types of reboots of the XSR - warm or cold - reboots can be triggered in up
to eight different ways. Refer to the table below.
Table 1 Reboot Triggers
Cause
Boot Type
Power-up
Cold
CLI reload
Cold or Warm
SNMP reload
Cold or Warm
Watchdog Expiration
Warm
Software Crash
Warm
Repetitive Software Crash
Cold
ROM Monitor
Cold or Warm
Invalid SW text checksum
Warm
Power-Up Reboot
If you power cycle the XSR by flipping the switch on the back panel, the XSR will cold reboot. The
startup-config file stored in Flash becomes the running configuration.
3-34
Software Configuration
Bootrom Monitor Mode Commands
Reload Command from the CLI
You can reboot the XSR firmware by issuing the command reload <cold | warm>. You are then
prompted to confirm the command. Once the firmware is reloaded, the configuration is loaded
from the startup-config file.
Bootrom Monitor Commands bc and bw
Using Bootrom Monitor mode, you can activate warm or cold reboots by entering bw or bc,
respectively. Refer to “Bootrom Monitor Mode Commands” on page 3-35 for more data.
Watchdog Timer Expiration
When the internal watchdog timer expires, causing the XSR to fail, fault information is captured in
a report and a warm boot is initiated. But if more than three warm boots are detected within one
minute, a cold boot will be initiated.
System Crash
When system exceptions occur causing the XSR to fail, fault information is captured in a report
and a warm boot is initiated. But if more than three warm boots are detected within one minute, a
cold boot will be initiated.
Restart with Default Configuration Interrupt
When you press the Default button on the back panel, the XSR restarts using factory default
parameters, ignoring the startup-config file.
Power-up Error Conditions
After power-up, the XSR comes up automatically if:
•
The minimum hardware is functional: Processor, RAM and FLASH memory, and other
components.
•
Bootrom is valid.
•
The software image in Flash is valid.
Bootrom Monitor Mode Commands
Bootrom monitor mode offers special user access when the XSR lacks valid software or runs
abnormally. Enter the mode by pressing the key combination (CTRL-C) during the first five
seconds of initialization. After you access the mode, list command groups by typing h to show the
text below:
b
f
n
s
t
D
Boot
Files
Network
Status
Time and Date
For Development Only
XSR Getting Started Guide
3-35
Bootrom Monitor Mode Commands
All the commands in each group can be listed by entering the command group letter. The main
menu provides the following functions:
•
Reboot warm or cold
•
Update Bootrom
•
File system-related commands for the Flash ROM file system
•
Modify network parameters
•
Various status/show commands
• Version number
• Hardware information
• Display crash info
•
Display or change date and time on real-time clock if present
•
Commands for development use only
Caution: Upon accessing Bootrom monitor mode, if you do not provide the password (if
configured earlier with the bp command) when prompted or enter an incorrect password five
times, the XSR will delete your configuration and reinstitute factory default settings. This function
is similar to pressing the reset button on the XSR-1800 Series routers.
bc
This command initiates a cold reboot.
bw
This command initiates a warm reboot.
bp
This command changes the Bootrom password. The default password is blank. You are prompted
to enter a password by the following script:
XSR-3150:bp
Enter current password:
Enter new password: ******
Re-enter new password: ******
Password has changed.
bu
This command updates the bootrom from a local file. You are prompted to enter data by the
following script. When the “Proceed with erasing Bootrom in flash ...” statement appears,
enter y. Be sure not to interrupt the process or power down the XSR or it may be affected
adversely. After you have updated this file, you can delete it from Flash to conserve space for
other files.
XSR-3150: bu btXSR3000_1_2.fls
Verifying btXSR3000_1_2.fls file ...
3-36
Software Configuration
Bootrom Monitor Mode Commands
bootFirst size=28992 sum=0xc2e5 compressed_size=28992 entry=0x80020000
bootrom size=842656 sum=0xfa65 compressed_size=347728 entry=0x81e00000
OK
Proceed with erasing current Bootrom in flash and replace with btXSR3000_1_2.fls?
(y/n) y
First copy of Bootrom ...
Erasing 3 sectors at address=0xbfc20000
Programming 131072(0x20000) bytes at address 0xbfc20000
Programming 131072(0x20000) bytes at address 0xbfc40000
Programming 85600(0x14e60) bytes at address 0xbfc60000
Verifying Bootrom flash sectors
Locking 3 Bootrom flash sectors
Second copy of Bootrom ...
Erasing 3 sectors at address=0xbfca0000
Programming 131072(0x20000) bytes at address 0xbfca0000
Programming 131072(0x20000) bytes at address 0xbfcc0000
Programming 85600(0x14e60) bytes at address 0xbfce0000
Verifying Bootrom flash sectors
Locking 3 Bootrom flash sectors
*****
Bootrom update completed.
*****
bU
This command updates the bootrom through a network transfer to a local file. Be sure to enter the
U in uppercase. After you have updated this file, you can delete it from Flash to conserve space for
other files.
cd
This command changes the current directory in the file system to flash: or cflash:.
copy
This command copies a file using the syntax copy <source name> <destination name>. You
can copy files from flash: to cflash: and vice versa.
da
This command shows system date/time with the sample output below:
XSR-3020:da
Date: Thursday, 29-MAY-2003.
Time: 10:14:07
XSR Getting Started Guide
3-37
Bootrom Monitor Mode Commands
df
This command shows free disk space. Sample output is shown as follows:
XSR-3150:df
Free space on flash: is 3383296 bytes (0x33a000).
del
This command removes a file from flash: or cflash: memory.
dir
This command lists the contents of the current directory in long format. The command displays
the following sample output:
XSR-3150: dir
Listing Directory flash::
-rwxrwxrwx 1 0
0
-rwxrwxrwx 1 0
0
-rwxrwxrwx 1 0
0
-rwxrwxrwx 1 0
0
4678118
2228
1153
0
May 5 23:06 xsr3000.fls
May 29 09:57 persistent-data
May 29 09:51 startup-config
May 29 09:51 private-config
2895872(0x2c3000) bytes free on flash:
ds
This command sets the system date with the syntax yyyy mm dd w (1=Sunday). For example:
XSR-3020: ds 2003 6 1 3
dt
This command sets the system time using the syntax hh mm ss. E.g.:
XSR-3150: ds 11 59 59
ff
This command formats the Flash file system. We recommend that you first save any .dat,
.cert, .cfg, and your startup-config files to cflash: or a PC since any files in flash: will be
deleted. You are prompted to enter data by the following script:
XSR-3150: ff
You will lose all files in the “flash:” file system.
Are you sure you want to format the “flash:” file system? (y/n) y
Unlocking flash file sectors
Initializing DOS file system.
Formatting flashrom file system
...................................................... Done.
3-38
Software Configuration
Bootrom Monitor Mode Commands
Set working directory to flash:
Using default Bootrom password. The system is not secure!!!
Use “bp” to change password
ffc
This command formats the CompactFlash card.
ng
This command retrieves a file over the network using a remote IP address/file path.
np
This command modifies network parameters. You are prompted to enter data by the following
script. While most of the options are self-explanatory, three require further description.
•
When set to no, the Autoboot option places the prompt in Bootrom mode when you boot or
power up the XSR.
•
When set to yes, the default Quickboot action of delaying five seconds at startup for you to
optionally enter CTRL-C and acquire Bootrom mode is negated. You can still acquire Bootrom
mode, but you must immediately press CTRL-C upon seeing the X-Pedition Security Router
Bootrom header.
•
The default hostname (local target name), XSR-3000, cannot be changed. In the absence of a
user-supplied hostname via the hostname CLI command, this name will be used as the CLI
prompt and SNMP hostname in MIB-II.
XSR-3150: np
Enter ‘.’ = clear a field; ‘-’ = go to previous field;
^C = quit
Local IP address (192.168.1.1)
:
Gateway IP address ()
:
Remote Host IP address (192.168.1.10) :
Remote file path (c:\)
:
Use TFTP (no)
:
Ftp userid (anonymous)
:
Ftp password ()
:
Local target name (robo1)
:
Autoboot (yes)
:
Quick boot (no)
:
Permanently save the network parameters? (y/n)
ns
This command saves a file over the network using a remote IP address/file path.
XSR Getting Started Guide
3-39
Bootrom Monitor Mode Commands
remove
This command removes a file using the syntax remove <source name> <destination name>
rename
This command renames a file using the syntax rename <source name> <destination name>
sb
This command displays boot values. Sample output is shown as follows:
XSR-3150: sb
Current boot file is xsr3000.fls
Boot selector default is flashrom, compactFlash, network
Available Network boot devices: sbe0
sf
This command displays a fault report. Sample output is shown as follows. You can enter sf to
display output from both CPUs or sf 0 or sf 1 to display output from either CPU.
XSR-3150: sf
Software Revision: 6.0.0.0 without VPN; without Firewall
Creation Date:
Sep 7 2003, 16:07:42
Broadcom BCM1250 Rev 2 CPU0 up-time 0 hours 2 minutes 20 seconds
Crashed Task = PP, Task Status = 0, errno=0 initStage=0
Exception Vector Number=0x5, Address error exception, store
pc=
821014b0 sp=
85febb90 STATUS= 3400ff81
zero=
00000000 at=
08110000 v0=
11223344
v1=
a0=
3400ff81 a1=
00000000 a2=
3400ff81
a3=
t0=
00000000 t1=
3400ff80 t2=
3400ff81
t3=
t4=
00000001 t5=
0000009b t6=
0a0122d4
t7=
s0=
85febbe0 s1=
8219d3dc s2=
00000000
s3=
s4=
00000000 s5=
00000000 s6=
00000000
s7=
t8=
00000000 t9=
00080000 k0=
eeeeeeee
k1=
gp=
8219b1e0 sp=
85febb90 s8=
00000000
ra=
par1=
ffffffff par2=
85febaf8 par3=
ffffffff
par4=
cause=
80000014 cntxt=
ffffffff fpcsr=
d3800000
badva=
divLo=
00000000 divHi=
00000000 causeR= ffffffff
fpcsr=
BadVAddr=08112233
PP - Crashed Task Stack
0x85feb790
ffffffff
0x85feb7a0
00000000
0x85feb7b0
00000000
0x85feb7c0
ffffffff
0x85feb7d0
00000000
0x85feb7e0
ffffffff
3-40
Software Configuration
(sp=85febb90):
00000000 00000008
00000001 00000000
8214ab00 0000000a
85feb7c0 ffffffff
00000002 ffffffff
82154b50 00000000
ffffffff
00000001
82142ee0
bf3285a4
85feb7e0
00000017
00000000
85feb8f8
00000000
00000004
00000000
00000000
00000000
820e9178
820e9b10
08112233
820e9170
Bootrom Monitor Mode Commands
......
si
This command displays XSR 3000 Series inventory with this sample output:
XSR-3150: si
Hardware:
Motherboard Information:
XSR-3150 ID: 9002914-04 REV0A CPLD Rev 3
Serial Number: 2914024201123206
Processor: Broadcom BCM1250 Rev 2 at 600MHz
PowerSupply1, PowerSupply2
Fans 1 2 3 4 5 7 8 10
CPU Temperature Max: 80C Current: 35C
Router Temperature Max: 60C Current: 23C
RAM: 512MB without interleave
Memory Bus at 120MHz, CASL at 2.0
Bootrom Flash: 4MB
Filesystem Flash: 8MB
CompactFlash not present
Real Time Clock
I/O on Motherboard:
GigabitEthernet 1 2 3
Encryption Hardware: not present
Slot 0 card 1: Empty
Slot 0 card 2: Empty
System up for 9 days, 3 hours, 4 minutes 10 seconds.
sn
This command shows network values with the following sample output:
XSR-3150: sn
Local IP address
Gateway IP address
Remote IP address
Remote file path
Transfer Protocol
Local target name
Autoboot
Quick boot
:
:
:
:
:
:
:
:
192.168.1.12
192.168.1.1
192.168.1.2
c:/XSR3000
FTP
XSR1
enabled
no
Current GigabitEthernet 0 MAC address is: 00:01:f4:2b:3e:1b
Current GigabitEthernet 1 MAC address is: 00:01:f4:2b:3e:1c
Current GigabitEthernet 1 MAC address is: 00:01:f4:2b:3e:1d
XSR Getting Started Guide
3-41
Bootrom Monitor Mode Commands
sv
This command shows the bootrom version with sample output below:
XSR-3150: sv
X-Pedition Security Router Bootrom
Copyright 2003 Enterasys Networks Inc.
HW Version: 9002914-04 REV0A Serial Number: 3646031700233215
CPU: Broadcom BCM1250 Rev 2
VxWorks version: VxWorks5.4.2
Bootrom version: 1.0
Creation date: Apr 14 2003, 10:12:36
3-42
Software Configuration
A
Specifications
System Specifications
This appendix details XSR data about hardware functionality including:
•
Processor, system memory, chassis, power supply, interfaces
•
Required cabling, CompactFlash and other accessories
•
Pinout assignments for WAN and LAN interfaces
•
LED behavior
Refer to tables throughout this appendix for specific information.
Table A-1
Category
Processor
XSR Hardware Specifications
Parameters
Type
Broadcom 1250 with two CPU cores
Dual-core
Operating Speed
1700 Dhrystone MIPS @ 600 MHz
Hardware
accelerator
VPN
Encryption Module chip (310 Mbps) for 3DES encryption, message
digest (MD-5, SHA-1), and public key acceleration,
System
Memory
RAM
2, Micron 184-pin, SDRAM DIMM, 128 Mbyte memory modules at
133 MHz each (data rate of 256 Mbps)
Non-Volatile
8 Mbytes of Onboard Flash - no upgrade
Up to 1 Gbyte optional plug-in CompactFlash card. Type I and II CF
cards supported
Chassis
Form Factor
19-inch rack-mountable
Dimensions
1U (1-11/16 inches high by 17 inches wide by 21 inches deep)
Weight
20 pounds
Heat
Dissipation
Forced air cooling
Maximum heat release of a fully configured system is
443.3 BTU/hr
Environment
Operating temp.
0 - 40° C
Storage temp.
-40 - 70° C
Relative Humidity
5% - 90%, non-condensing
A-1
Cable, CompactFlash and Accessory Specifications
Table A-1
Category
XSR Hardware Specifications (continued)
Parameters
Power
Consumption
Typical values:
Motherboard: 75 watts (maximum)
Serial NIM card: 4 watts
T1/E1/ISDN-PRI NIM card: 3 watts
ISDN BRI-S/T NIM card: 1 watt
Internal Power
Supplies (2)
Type
Dual universal (110/220 VAC) load-sharing, redundant units
Input AC Voltage
& Frequency
100-125 Vac, 1.7A
200-240 Vac, 0.85A
50/60Hz
I/O Interfaces
Onboard (LAN)
2 10/100/1000BaseT Ethernet ports with RJ-45 copper connectors,
10/100/1000 or Mini-GBIC optical connector
RS-232 COM serial port with DB-9 connector
NIM (WAN) Slots
Dual or Quad synch/asynch Serial ports with DB-type connector also
supporting X.21, V.35, EIA-449, EIA-232/530 and combined V.35/
EIA-232/530 DTE interfaces with required adapter.
Single, dual, or quad T1/E1 RJ-48C port(s) with integral CSU/DSU.
Full-channel, fractional or unchannelized.
Single port T3/E3 un-channelized NIM with BNC connectors
I/O Interfaces
NIM (WAN) Slots
Dual or quad port BRI/PRI S/T NIM (RJ-45) or U NIM with RJ-45 or
RJ-49C connectors, respectively.
Dual or quad port BRI/PRI S/T NIM (RJ-45) or U NIM with RJ-45 or
RJ-49C connectors, respectively.
Single port Annex A/C or B ADSL NIM with RJ-11 connector.
Includes CompactFlash card.
Chassis LEDs
NIM (LAN or
WAN)
Single port 10/100Base-T Copper or 10/100Base-F Fiber-optic
Ethernet NIM with RJ-45 connector or MT-RJ multi-mode interface,
respectively.
14
Display port and system status, warn of Flash upgrade
Cable, CompactFlash and Accessory Specifications
Refer to the following table for specifications of cables, CompactFlash and accessories for the XSR.
This equipment can all be obtained separately from Enterasys Networks or through any computer
supply retailer.
Table A-2
A-2
XSR Cabling/Accessory Guide
Part Description
Connector
Part #
Function
6’ DB-9 null modem cable
DB-9, male
N/A from Enterasys
COM link to serial line
.58, 1, 2, 3, 5, or 10 meter 10/100BaseT
straight-through or cross-over cable
RJ-45
N/A from Enterasys
Ethernet link to hub/switch or
PC/uplink port
Cable, CompactFlash and Accessory Specifications
Table A-2
XSR Cabling/Accessory Guide (continued)
Part Description
Connector
Part #
Function
1000Base-SX Mini-GBIC with connector
1000Base-LX Mini-GBIC with connector
1000Base-SX Mini-GBIC with connector
Short-haul LC
Long-haul LC
Short-haul MTRJ
MGBIC-LC01
MGBIC-LC09
MGBIC-MT01
Ethernet link to 1000BaseT line
Ethernet link to 1000BaseT line
Ethernet link to 1000BaseT line
2-port synch/asynch card
4-port synch/asynch card
68-pin, male
SCSI III
NIM-SER-02
NIM-SER-04
Serial NIM cards
6’ DB-15, X.21 DTE, twisted-pair cable
NIM-X21-CAB-04
Serial link to high speed serial
line: 2 or 4 port
6’ DB-25, EIA-232/530 DTE twisted-pair cable
NIM-232-CAB-04
6’ DB-37, EIA-449 DTE, twisted-pair cable
NIM-449-CAB-04
6’ DB-V.35 DTE, twisted-pair cable
68-pin, male
SCSI III
Combined V.35/EIA-232/530 DTE, twisted-pair
cable
NIM-V35-CAB-04
Serial link to high speed serial
line: 2 or 4 port
NIM-DBU1-CAB-04
-Single unchannelized T1/E1 card
-Dual unchannelized T1/E1 card
-Quad unchannelized T1/E1 card
RJ48C
RJ48C
RJ48C
NIM-T1/E1-01
NIM-T1/E1-02
NIM-T1/E1-04
T1/E1 NIM card
-Single channelized T1/E1/ISDN-PRI card
-Dual channelized T1/E1/ISDN-PRI card
-Quad channelized T1/E1/ISDN-PRI card
RJ48C
RJ48C
RJ48C
NIM-CT1E1/PRI-01
NIM-CT1E1/PRI-02
NIM-CT1E1/PRI-04
Single channelized PRI card
Dual channelized PRI card
Quad channelized PRI card
Single unchannelized T3/E3 card
2 female BNCs
NIM-T3E3-01
Single unchannelized T3/E3
NIM
1-port ISDN BRI-S/T card
2-port ISDN BRI-S/T card
RJ-45
RJ-45
NIM-BRI-ST-01
NIM-BRI-ST-02
BRI-S/T NIM card
BRI-S/T NIM card
1-port ISDN BRI-U card
2-port ISDN BRI-U card
RJ49C
RJ49C
NIM-BRI-U-01
NIM-BRI-U-02
BRI-U NIM card
BRI-U NIM card
1-port Annex A/C ASDL card with
CompactFlash
1-port Annex B ASDL card with CompactFlash
RJ-11
RJ-11
NIM-ADSL-AC-01
NIM-ADSL-B-01
ADSL NIM card
ADSL NIM card
2-port T1/E1 D&I card
RJ-45
NIM-DIRELAY-02
T1/E1 D&I NIM card
1-port Copper Ethernet card
1-port Fiber-optic card
RJ-45
MT-RJ
NIM-ETHR-01
NIM-FIBR-01
Copper Ethernet NIM card
Fiber-optic Ethernet NIM card
100/120-ohm, straight-thru, twisted-pair cable
T1 or E1Port
N/A from Enterasys
-
75-ohm coaxial to 120-ohm adapter
2 female BNCs
& 1 RJ-48C port
9372192
G.703 Balun adapter for E1 line
Grounding shunt
P2 - P5
N/A from Enterasys
Insulator for E1 line
Auxiliary Flash RAM: 1.4”L x 1.6” W
-8, 16, 32 MByte card
Front panel slot
N/A from Enterasys
CompactFlash card for greater
software storage and flexibility
XSR-31/3250 Firewall and VPN firmware
-
XSR-3XXX-VPN-FW
Firewall and VPN code
XSR-31/3250 VPN firmware
-
XSR-3XXX-VPN
VPN code
XSR-31/3250 Firewall firmware
-
XSR-3XXX-FW
Firewall code
XSR Getting Started Guide A-3
Cable, CompactFlash and Accessory Specifications
COM (Console) Port
The XSR comes equipped with a COM serial port useful for initial configuration and management.
Using a serial (null modem) cable, you can attach the router’s DB-9 COM port to a data terminal
port and directly configure the XSR over the asynchronous connection. Then, open a
communications or Telnet session to communicate with the router. If you use communications
program, set the connection properties as follows:
•
Connect using: Direct to COMx (where x is an unused COM port)
•
Bits per second: 9600
•
Data bits: 8
•
Parity: None
•
Stop bits: 1
•
Flow control: none
Note: The XSR default login is admin with no password.
Refer to Figure A-1 for pinout assignments.
Figure A-1
COM Port Pinouts
Pin Signal
1
COM
Pin 1
Pin 6
A-4
Pin 5
Pin 9
Carrier Detect (CD)
2
Receive Data (RX)
3
Transmit Data (TX)
4
Data Term Ready (DTR)
5
Ground (GND)
6
Data Set Ready (DSR)
7
Request to Send (RTS)
8
Clear to Send (CTS)
9
Ring Indicator (RI)
Cable, CompactFlash and Accessory Specifications
GigabitEthernet Ports
The XSR comes equipped with three GigabitEthernet (LAN) ports that support full-duplex 10, 100,
or 1000 Mbps transmission. The ports conform to IEEE 802.3 standards with 8-pin modular RJ-45
connectors. Because these ports have internal MDI crossover capabilities which allow them to
detect which mode (DTE or DCE) the link partner is operating at, you can use any cable to attach
the XSR with a PC or uplink port as long as a fully populated cable (all four pairs) is connected to
take advantage of full gigabit bandwidth.
.When the GigabitEthernet 1 port is used, the Mini-GBIC port is unavailable, and vice versa.
Refer to Figure A-2 for pinout assignments.
Figure A-2
GigabitEthernet Port Pinouts
Eth 1
Pin Signal
Pin 8
Pin 1
Eth 2 & 3
Pin 1
Pin 8
1
TRDO+
2
TRDO-
3
TRD1+
4
TRD2+
5
TRD2-
6
TRD1-
7
TRD3+
8
TRD3-
Mini-GBIC Fiber, Copper Port
The XSR offers a 1000Base-T GigabitEthernet port that supports full or half-duplex 1000 Mbps
transmission. The 20-pin, Mini-GBIC socket accepts all SFP MSA compliant Mini-GBIC modules.
Be aware of the following conditions when using Fiber or Copper ports:
•
When the Mini-GBIC port is used, GigabitEthernet port 1 is disabled.
•
When GigabitEthernet port 1 is used, the Mini-GBIC port is disabled.
•
If both Fiber and Copper ports are plugged in, only Fiber is enabled.
•
On GigabitEthernet port 1, when the far end of the line is active, the Fiber port takes
precedence.
•
If the Fiber port is connected, speed must be set to auto to achieve 1000 Mbits.
•
If the fiber port is connected, speed and duplex must be set to auto on both ends of the line
otherwise the connection will be unpredictable.
Refer to the XSR CLI Reference Guide for more command details.
Cabling for the Mini-GBIC is supported using an MTRJ connector with a fiber link or the
appropriate connector with a copper link.
XSR Getting Started Guide A-5
Cable, CompactFlash and Accessory Specifications
Copper/Fiber-optic Ethernet NIMs
The single-port Copper or Fiber-optic Ethernet NIMs, shown in Figure A-3 and Figure A-4,
provide interfaces for half and full-duplex 10/100Base-T or fiber-optic 100Base-F transmission
over LAN or WAN networks, respectively. The Copper Ethernet NIM incorporates a standard 8pin modular RJ-45 connector and the Fiber-optic Ethernet NIM has an MT-RJ multi-mode
interface. Both NIMs conform to IEEE 802.3 and PCI 2.2 standards.
Copper Ethernet NIM
Figure A-4
NIMETHR01
LINK ACT
Figure A-3
Fiber-optic Ethernet NIM
LINK ACT
NIMFIBR01
Refer to Figure A-5 for Copper Ethernet NIM pinout assignments.
Figure A-5
Eth 1 (Copper)
Pin 8
Pin 1
Copper Ethernet NIM Port Pinouts
Pin
Copper
Signal
1
Tx Data +
2
Tx Data -
3
Rx Data +
4
Not Used
5
Not Used
6
Rx Data -
7
Not Used
8
Not Used
Regulatory/Safety Compliance
The Copper and Fiber-optic Ethernet NIMs comply with these requirements: IEE 802.3, UL 1950,
CSA No. 950, EN 60950, and IEC 950 (CB Scheme Report).
A-6
Cable, CompactFlash and Accessory Specifications
2/4-Port Serial NIM Card Port
The High Speed Serial NIM card, as shown in Figure A-6, provides a WAN interface supporting a
serial link to four different types of DTEs: DB-15, 25, 37, and V.35. This interface supports dual and
quad traffic up to 8 Mbps.
Figure A-6
High Speed Serial NIM Port
68-pin Serial
Pin 1
Pin 68
Refer to Figure A-7 through Figure A-11 for pinout assignments.
Figure A-7
J1
3
11
5
10
4
7
6
8
15
16
9
14
X.21 DTE Pin Assignments
X.21 DTE
J2
Receive0+
4
Receive0Transmt0+
11
Transmit0Control0+
9
2
3
Control0-
10
Indication0+
5
Indication0Timing0+
12
Timing0Signal GND
13
6
8
Signal GND
Shield GND
37
45
39
44
38
41
40
42
49
50
43
48
1
J3
Receive1+
4
Receive1Transmt1+
11
Transmit1Control1+
9
2
3
Control1-
10
Indication1+
5
Indication1Timing1+
12
Timing1Signal GND
13
6
8
Signal GND
Shield GND
19
Receive2+
Receive2J1:
27 68-pin male SCSI II type connector
Transmt2+
21 - J5: DB-15 type male connector
J2
Transmit226
C
t l2+
Receive2+
19
J1
- 68-pin male SCSI III type connector
Receive227
J2...J5 - DB-15 type male connector Transmt2+
21
Transmit226
Control2+
20
Control223
Indication2+
PORT 1
22
Indication224
Timing2+
31
Timing2Notes: 32
Signal GND
1
25
- Indicates Twisted Pair Signal GND
.
30
2. Shield GND is braid on braided cable
3. Shield GND is drain wire on foil shield cable
4. Braid or foil must enter and make contact
Receive3+
inside
53metal connector hood
5. All connectors
must be metal
61
6. Pins not shown are unused
55
60
54
57
56PORT 2
58
65
66
59
64
J4
4
11
2
9
3
10
5
12
6
13
8
Shield GND
1
J5
4
Receive3Transmt3+
11
2
9
Transmit3Control3+
3
10
Control3Indication3+
5
Indication3Timing3+
12
6
Timing3Signal GND
13
8
Signal GND
Shield GND
1
1
J4
4
11
2
9
XSR Getting Started Guide A-7
Cable, CompactFlash and Accessory Specifications
Figure A-8
J1
1
2
3
11
5
10
4
7
EIA-232/530 DTE Pin Assignments
J2
DSR0+
6
DSR0-
22
RxD0+
3
RxD0-
16
TxD0+
2
TxD0-
14
RTS0+
4
RTS0-
19
DTR0+
20
DTR06
8
12
13
15
16
9
14
CTS0TxC0+
36
37
45
39
44
38
41
42
46
47
49
50
43
48
7
Signal GND
1
J3
DSR1+
DSR1RxD1+
RxD1TxD1+
TxD1RTS1+
RTS1DTR1+
CTS1TxC1RxC1+
27
21
A-8
52
3
53
16
61
2
55
14
60
4
54
19
57
56
13
58
15
62
12
63
7
Signal GND
65
66
59
64
Shield GND
1
J4
6
22
3
16
2
2
14
4
19
20
23
5
CTS2-
13
TxC2 +
15
12
17
9
7
Shield GND
6
DSR3RxD3+
22
3
RxD3-
16
TxD3 +
2
TxD3-
14
RTS3+
4
RTS3Port 2
1
J5
DSR3+
19
DTR3+
20
DTR3-
5
9
Signal GND
TxD2+
51
17
RxC1-
RxD2-
6
22
23
TxC1+
3
16
CTS2+
28
Notes:
TxC21 29
- Ind icates Twisted Pair RxC2+
.
31
2 . Shie ld GND is braid on braid ed cab RxC2le
32 ld GND is drain wire on foil shield cab
3 . Shie
Signa l GND
25 or foil must enter and make contact
4 . Braid
Signa l GND
inside
30 metal co nn ecto r hood
5 . All connectors must be metal
6 . Pins not sho wn are unuse d
20
CTS1+
DSR2+
24
9
Signal GND
J1: 68-pin male SCSI IIDSR2type connector
18
RxD2+
J219 - J5: DB-25 type male
connector
17
13
17
RxC0-
DTR140
22
12
Shield GND
35
5
15
TxC0RxC0+
6
22
DTR2-
23
CTS0+
J4
DSR2+
J1 17 - 68-pin male SCSI III type con ne cto
DSR218 - DB-25 type male connector
J2...J5
RxD2+
19
RxD227
TxD2 +
21
TxD226
RTS2+
20
Port 1
RTS223
DTR2+
23
CTS3+
5
CTS3-
13
TxC3 +
15
TxC3-
12
RxC3+
17
RxC3-
9
Signa l GND
7
Signa l GND
Shield GND
1
Cable, CompactFlash and Accessory Specifications
Figure A-9
J1
1
2
3
11
5
10
4
7
EIA-449 DTE Pin Assignments
J2
ON0+
11
ON0-
29
RD0+
6
RD0-
24
SD0+
4
SD0-
22
RS0+
7
RS0TR0+
25
12
TR06
8
12
13
15
16
9
14
CS0ST0+
ST0RT0+
36
37
45
39
44
38
41
42
46
47
49
50
43
48
18
26
11
ON1-
29
RD1SD1+
SD1RS1+
RS1TR1+
20
31
32
No tes:
1
25- Ind icates Twiste d Pair
.
30 is braid on braid ed cable
2. Shield GND
3. Shield GND is drain wire o n foil shield cab
4. Braid or foil must enter and make con tact
insid e meta l co nn ecto r h ood
5. All conne ctors must be me tal
51
6. Pin s not shown
are u nu se d
52
6
53
24
61
CS1ST1+
ST1RT1+
RT1SG1
SC1
RC1
ON2+
7
25
12
30
9
27
5
ST2RT2+
23
8
RT2-
26
SG2
19
SC2
37
RC2
20
Shield GND
11
ON3-
29
RD3+
6
RD3-
24
SD3+
7
54
25
57
RS3TR3+
9
Port 2
56
CS3+
27
58
4
SD3-
22
RS3+
7
25
12
TR3-
5
62
23
63
8
65
26
66
19
59
37
64
1
J5
ON3+
60
1
4
22
ST2+
55
20
6
24
CS2-
4
30
29
CS2+
22
12
CS1+
SD2-
29
1
RD1+
RS2+
28
J3
J1: 68-pin male SCSIRD2+
II type connector
19
RD227
J2 - J5: DB-37 type male
connector
SD2+
21
5
23
20
ON1+
ON2-
24
37
RC0
Shield GND
17
27
19
SC0
TR140
22
26
SG0
Shield GND
35
9
8
RT0-
11
TR2-
30
CS0+
J4
ON2+
17 male SCSI III type con ne ctor
J1
- 68-pin
ON218 type ma le con nector
J2...J5 - DB-37
RD2+
19
RD227
SD2+
21
SD226
RS2+
20
RS223
TR2+
Port 1
30
9
CS3-
27
ST3+
5
ST3-
23
RT3+
8
RT3-
26
SG3
19
SC3
37
RC3
20
Shield GND
1
J4
11
29
6
24
4
22
7
XSR Getting Started Guide A-9
Cable, CompactFlash and Accessory Specifications
Figure A-10
J1
1
2
3
11
5
10
4
7
PORT 3
(EIA-232/530)
6
8
12
13
15
16
9
14
35
37
45
39
44
38
40
46
47
49
50
43
48
Combined V.35/EIA-232/530 DTE Pin Assignments
J2
DSR3+
DSR3RxD3+
RxD3TxD3+
TxD3RTS3+
RTS3DTR3+
DTR3CTS3+
CTS3TxC3+
TxC3RxC3+
RxC3Signal GND
Signal GND
6
22
3
16
2
14
4
19
20
23
5
13
15
12
17
9
7
Shield GND
PORT 2
(V.35)
E
R
T
P
S
C
H
D
Y
AA
V
X
B
Shield GND
J1: 68-pin male SCSI III-type connector
J3, J5: V.35-type male connector
J2. J4: DB-25-type male connector
Pins not shown are unused.
A-10
22
24
28
29
31
32
25
30
1
J3
DSR2
RD2+
RD2SD2+
SD2RTS2
DTR2
CTS2
SCT2+
SCT2SCR2+
SCR2Signal GND
Signal GND
17
18
19
27
21
26
20
23
A
PORT 1
(EIA-232/530)
51
53
61
55
60
54
56
62
63
65
66
59
64
J4
DSR1+
DSR1RxD1+
RxD1TxD1+
TxD1RTS1+
RTS1DTR1+
DTR1CTS1+
CTS1TxC1+
TxC1RxC1+
RxC1Signal GND
Signal GND
6
22
3
16
2
14
4
19
20
23
5
13
15
12
17
9
7
Shield GND
PORT 0
(V.35)
1
J5
DSR0
RD0+
RD0SD0+
SD0RTS0
DTR0
CTS0
SCT0+
SCT0SCR0+
SCR0Signal GND
Signal GND
E
R
T
P
S
C
H
D
Y
AA
V
X
B
Shield GND
A
Cable, CompactFlash and Accessory Specifications
Figure A-11
J1
1
3
11
5
10
4
6
12
13
15
16
9
14
V.35 DTE Pin Assignments
J2
DSR0
E
RD0+
R
RD0 -
T
P
SD0+
SD0 RTS0
S
C
DTR0
H
CTS0
D
22
Y
28
AA
29
SCT0+
SCT0SCR0+
V
SCR0Signa l GND
X
B
Signa l GND
Shield GND
35
37
45
39
44
38
40
46
47
49
50
43
48
A
J3
DSR1
E
RD1+
R
RD1 -
T
SD1+
P
SD1 -
S
RTS1
C
DTR1
H
CTS1
56
SCT1-
Y
62
SCR1+
AA
63
V
65
X
66
B
59
SCR1Signa l GND
Signa l GND
64
Shield GND
17
DSR2
J1:
68-pin male SCSI IIRD2+
type connector
19
RD2 27 - J5: V.35 type male connector
J2
SD2+
21
26
SD2 RTS2
A
E
R
T
P
S
C
H
CTS2
D
SCT2+
Y
SCT2-
SCR2+
31
No te s:
SCR21
32
- Ind icates Twiste d Pair
.
Signal GND
25ld GND is b raid on bra ided cable
2. Shie
Signal GND
3. Shie
30ld GND is d rain wire on fo il shield ca b
4. Braid o r fo il must en te r and make contact
insid e meta l co nnecto r hood
5. All co nnecto rs must be metal
DSR3
51 not shown are unu se d
6. Pins
RD3+
53
RD3 61
SD3+
55
SD360
RTS3
54
DTR3
D
SCT1+
J4
DSR2
17
J1
- 68 -p in male SCSI III type conne
cto
RD2+
19
J2...J5 - V.35 type ma le conne ctor
RD2 27
SD2+
21
SD226
RTS2
20
Port 1
DTR2
AA
V
X
B
Shield GND
E
R
T
P
S
C
H
CTS3
Port 2
A
J5
D
SCT3+
Y
SCT3-
AA
SCR3+
V
SCR3-
X
Signal GND
B
Signal GND
Shield GND
A
J4
E
R
T
P
S
XSR Getting Started Guide A-11
Cable, CompactFlash and Accessory Specifications
T1/E1/ISDN PRI NIM Card Ports
The T1/E1/ISDN PRI NIM, as shown in Figure A-12, comes equipped with either 1, 2 or 4
Ethernet (WAN) ports that support fractional T1/E1 transmission in full-channel, fractional or
unchannelized format with 8-pin modular RJ-48C connectors and include a built-in DSU/CSU.
Cables required for these ports must be 100-ohm, straight-through, twisted-pair for T1 lines and a
120-ohm version for E1 lines. Refer to Figure A-13 for pinout assignments.
Note: If you are using the TI/EI/ISDN PRI NIM in Singapore or Australia, the cables required for
these ports must not employ individual shields for each pair.
Figure A-12
4-Port T1/E1/ISDN PRI NIM Card (RJ-48C ports shown)
Figure A-13
T1/E1/ISDN PRI
Pin 1
Pin 8
T1/E1 NIM Port Pinouts
Pin Signal
1
Receive Ring
2
Receive Tip
3
Chassis GND (optional)
4
Transmit Ring
5
Transmit Tip
6
Chassis GND (optional)
7
no connection
8
no connection
Regulatory/Safety Compliance
The T1/E1 ISDN PRI NIM complies with these regulatory requirements: PCI Local Bus
Specification Rev 2.1, IEEE P1386 Draft 2.4, IEEE P1386.1 Draft 2.4, ANSI T1.403, ITU-T G.703,
G.704, G.706, G.736, G.775, G.823, I.431, Q.703, AT&T TR62411 and TR54016, ETSI ETS 300233, and
IEEE 1149.1.
The NIM also complies with the following safety requirements: CS03, FCC Class B, TBR12-14, GR1089, ITU K17-K20, IEC 61000-4-2, IEC 61000-4-5, UL 1950, IEC 950, and EN 60950.
A-12
Cable, CompactFlash and Accessory Specifications
Balun for E1 or PRI NIM Cards
Some overseas electrical systems require that you use a balun and grounding shunt when utilizing
an E1 or PRI NIM card on the XSR. A balun is an adapter employed to connect a 75-ohm coaxial
cable pair (2 BNC connectors) to a 120-ohm twisted pair cable (RJ-48C connector).
The balun and its connectors are shown in Figure A-14. The grounding shunt is also required to
insulate (ground) unused pins of the RJ-48C connector.
To install the balun, attach the 75-ohm coaxial cables to the BNC connectors and a 120-ohm E1/
PRI cable to the RJ-48C port (see below for details).
Figure A-14
Balun for E1 or PRI Connection
J12 Transmit BNC
male connector
75-ohm connection
to your network
RX
MCn
60 lu
LN
l 4 Ba
B
de 03
Xt
OA
MoG.7
Ou
1-C
TX
In
NI
E
M-
J2 Receive BNC
male connector
75-ohm connection
to your network
120-ohm
connection to XSR
XSR Getting Started Guide A-13
Cable, CompactFlash and Accessory Specifications
Grounding Shunt for E1 NIM Cards
If you connect a balun to a 75-ohm line, you will also need to attach a grounding shunt (or
terminal strip) to any NIM pins whose RJ-48C connectors utilize the balun. The XSR requires that
you use a shunt (shown in Figure A-15), or terminal strip to ground pins 3 and 6 of the RJ-48C
interface, which are not needed to complete the connection.
Figure A-15
Sample Grounding Shunt
Caution: The cable connecting the E1/PRI NIM to the balun requires two more wires to extend
the chassis ground to the balun. Cables of this type are often provided by your supplier who can
customize them to your needs.
Refer to “Hardware Installation” on page 2-1 for directions on accessing the E1 card on the XSR.
Installing Shunt/Terminal Strip
To install the shunt or terminal strip, attach two dual-pin units vertically to each four-pin jumper
(P2, P3, P4, or P5) corresponding to the RJ-48C port using a balun, as shown in Figure A-16. Any
other RJ-48C ports on the NIM card connected to 120-ohm lines do not require shunts.
Figure A-16
A-14
Installing a Grounding Shunt on the E1 NIM Card
Cable, CompactFlash and Accessory Specifications
T3/E3 NIM Card
The T3/E3 full and sub-rate NIM, as shown in Figure A-17, is equipped with 1 Ethernet (WAN)
port that supports fractional T3/E3 transmission in un-channelized or clear channel mode with
BNC connectors. User data are encapsulated in HDLC packets before being sent to the line.
Figure A-17
Tx
1-Port T3/E3 NIM Card
ALARM
LOS
Rx
ENABLE LOF
id
Cables required for this NIM must be 75-ohm, DS3 Type 734 or 735 coaxial. DS3 cables support a
length up to 450 in length. E3 cabling supports a cable ble length up to 900 feet.
Un-channelized mode consists of the entire T3/E3 payload in one data path, but with T3/E3 framing
bits still in place. Only one HDLC channel is used. Throughput of the un-channelized link can be
limited by using only a portion of the entire payload. Various sub-rates are available to provide
compatibility with major DSU equipment suppliers. Scrambling may also be enabled as required
for DSU compatibility. Larscom zero suppression is supported.
Clear channel mode presents the board merely as the line driver for a link carrying HDLC packets
where even framing bits are used for data transfer. The T3/E3 framer operates in bypass mode
which is selected by a CLI command and renders the NIM a line driver. Both sides of the link must
have the same setting to operate correctly in this mode.
For more details on software configuration, refer to the XSR User’s Guide.
Regulatory/Safety Compliance
The T3/E3 NIM complies with the following regulatory requirements.
E3: FCC Class B, ITU-T G.703, G.704, G823 and TBR24 for world wide approval, National
Standards testing as required, and BABT Compliance United Kingdom directive 607114.
T3: FCC Class B, GR-499-CORE is the Bellcore test procedure that can be used for design
validation, JATE Green Book for Japan.
XSR Getting Started Guide A-15
Cable, CompactFlash and Accessory Specifications
1/2-Port BRI-S/T ISDB NIM Card Ports
The XSR provides a serial NIM card for 1 or 2 WAN interfaces over an ISDN-S/T BRI line, as
shown in Figure A-18. The Port 0 and 1 LEDs shine when the lines are active and ready to receive
traffic. See Figure A-19 for pinout assignments.
Figure A-18
ISDN BRI-S/T NIM Card (RJ-45 ports shown)
Port 0 Activation LED
Port 1 Activation LED
Figure A-19
ISDN BRI-S/T NIM Pinouts
BRI-S/T
Pin 1
Pin Signal
Pin 8
1
Unused
2
Unused
3
Transmit (+)
4
Receive (+)
5
Receive (-)
6
Transmit (-)
7
Unused
8
Unused
Termination Shunt for the ISDN BRI-S/T NIM Card
ISDN BRI-S/T terminal equipment devices may be connected at random points of the cable in
point-to-point or point-to-multipoint configurations. Line termination resistors must be provided
at both ends of the transmit/receive lines only.
The XSR’s BRI NIM card provides an option to terminate receive as well as transmit lines using
100 Ohm resistors. Shunts are required to shorten the appropriate contacts of the terminal headers
(P1, P2). Refer to “Installing Shunt/Terminal Strip” on page -17 for directions.
Figure A-20 below shows per port respective termination header locations and the orientation of
the receive and transmit pairs.
Caution: The cable connecting the BRI NIM to the balun requires two additional wires to extend
the chassis ground to the balun. Cables of this type are often provided by your supplier who can
customize them for your needs.
Refer to Chapter 2 for directions on accessing the BRI card on the XSR.
A-16
Cable, CompactFlash and Accessory Specifications
Installing Shunt/Terminal Strip
To install the shunt or terminal strip, attach two dual-pin units vertically to P1 and P2 four-pin
jumpers corresponding to the RJ-45 port using a balun, as shown in Figure A-20. Any other RJ-45
ports on the NIM card connected to 120-ohm lines do not require shunts.
Figure A-20
Installing a Termination Shunt on BRI-S/T NIM Card
F14
F15
F16
F17
R eceive P air Term ination
T2
T1
P1
P2
Transm it Pair Term ination
F4
F6 J2
F7
F8
P ort 1
CR2
CR1
Port 0
F5
R133
F3
R132
Port 0
F1 F2J1
P ort 1
XSR Getting Started Guide A-17
Cable, CompactFlash and Accessory Specifications
1/2-Port BRI-U NIM Card Ports
The XSR provides a serial NIM card for 1 or 2 WAN interfaces over an ISDN BRI-U line, as shown
in Figure A-21. Port 0 and 1 LEDs shine when the lines are active and ready to receive traffic.
Figure A-21
ISDN BRI-U NIM Card (RJ-49C ports shown)
Port 0 Activation LED
Port 1 Activation LED
Refer to Figure A-22 for pinout assignments.
Figure A-22
Pin Signal
BRI-U
Pin 1
ISDN BRI-U NIM Pinouts
Pin 8
1
Unused
2
Unused
3
Unused
4
Signal (Tip)
5
Signal (Ring)
6
Unused
7
Unused
8
Unused
Regulatory/Safety Compliance
The ISDN BRI-U NIM complies with the following regulatory requirements: PCI Local Bus
Specification Rev 2.2, IEEE P1386 Draft Rev 2.4, IEEE P1386.1 Draft Rev 2.4, ANSI T1.601-1999,
and IEEE 1149.1.
The NIM also complies with the following safety requirements: FCC Part 68, CS03, FCC Class B,
UL 1950, IEC 950, and EN 60950.
A-18
Cable, CompactFlash and Accessory Specifications
1-Port ADSL NIM Card Port
The XSR’s Asymmetric Digital Subscriber Line (ADSL) NIM card, as shown in Figure A-23,
provides 1 WAN port on an ADSL over POTS (Annex A/C) or ISDN (Annex B) line with a 6-pin
RJ-11 connector. The ADSL NIM supports both G.dmt and G.lite standards. ADSL NIMs are
shipped with a CompactFlash card containing DSP firmware. This driver software copies the
Flash file into host memory where it provides on-demand use by the DSP.
Figure A-23
ADSL NIM Card
LED 2
LED 1
Note: The XSR supports only one ADSL card type at a time, so multiply-installed card types must be
similar.
The LEDs behave as follows: LED 1 - Status - When OFF, the line is down; when ON; the line has
ended “training” or synchronization with the remote DSLAM device and is operational; when
Flashing, the line is in training mode; LED 2 - Data - When flashing, traffic is active.
Refer to Figure A-24 for pinout assignments.
Figure A-24
ADSL NIM Pinouts
Pin Signal
ADSL
Pin 1
Pin 6
1
Unused
2
Unused
3
Signal (Tip)
4
Signal (Ring)
5
Unused
6
Unused
Regulatory/Safety Compliance
The ADSL NIM complies with the following regulatory requirements: EN 55022, EN 55024, FCC
Part 68, CS03, TIA/EIA-IS-968, T1.413, ITU G.992.1, ITU G.992.2, ITU G.991.2, ITU G.994.1,
Deutsche Telecom U-R2 specifications and ANSI Standard T1.413-1998 (issue 2) specifying full
rate ADSL.
The ADSL NIM also complies with the following safety requirements: UL 1950, CSA No. 950, EN
60950, and IEC 950 (CB Scheme Report).
XSR Getting Started Guide A-19
Cable, CompactFlash and Accessory Specifications
T1/E1 Drop & Insert (D&I) NIM
The XSR’s 2-port T1/E1 D&I NIM card, as shown in Figure A-25, is designed as an intermediary
between the Central Office T1/E1 line and a PBX. It de-couples Channel Associated Signaling
(CAS) and Voice DS0 timeslots and redirects them to a PBX, and conversely, reintegrates Voice DS0
timeslots from the PBX with the T1/E1 data stream. Both ports are functionally equivalent.
Figure A-25
T1/E1 D&I NIM Card
The T1/E1 D&I NIM provides long- and short-haul capabilities and Drop and Insert functionality
via a fully configurable Time Division Multiplexed (TDM) switch. It can be configured for data
only, or voice/data applications. In Data-Only mode, both ports pass data, whereas in Voice/Data
mode, one port passes a voice/data stream, while the other passes only voice.
The T1/E1 D&I NIM maintains high reliability of voice traffic by using a bypass relay to ensure
continued service even if a power failure occurs or the NIM enters an abnormal state. In such an
event, the two ports are connected, bypassing the NIM, thus allowing uninterrupted bidirectional
voice transmission. To ensure service, remember to configure voice timeslots on both sides of the
connection in the same manner. That is, if timeslots 3-5 are configued for voice on the NIM, the
same DS0s should be configured for voice at the Central Office. Refer to the XSR User’s Guide for
instructions.
Refer to Figure A-26 for pinout assignments.
Figure A-26
T1/E1 D&I NIM Pinouts
Pin Signal
T1/E1 D&I
Pin 8
Pin 1
1
Unused
2
Unused
3
Unused
4
Signal (Tip)
5
Signal (Ring)
6
Unused
7
Unused
8
Unused
Regulatory/Safety Compliance
The T1/E1 D&I NIM complies with the following regulatory requirements: PCI Local Bus
Specification Rev 2.1, IEEE P1386 Draft 2.4, IEEE P1386.1 Draft 2.4, ANSI T1.403, ITU-T G.703,
G.704, G.706, G.736, G.775, G.823, I.431, Q.703, AT&T TR62411, TR54016, ETSI ETS 300233, and
IEEE 1149.1.
The T1/E1 D&I NIM also complies with the following safety requirements: FCC Part 68, CS03,
FCC Class B, TBR12, 13, 14, GR-1089, ITU K17-K20, IEC 61000-4-2, IEC 61000-4-5, UL1950, IEC 950,
and EN 60950.
A-20
Cable, CompactFlash and Accessory Specifications
CompactFlash Memory Card
The optional plug-in CompactFlash (CF) memory card, shown in Figure A-27, comprises a single
chip controller and flash memory modules in a matchbook-sized package with a 50-pin, PCMCIA
connector consisting of two rows of 25 female contacts each.
The PCMCIA male interface supports both Type I and Type II CF cards. Note that the CF release
mechanism pops out when you install the card. For installation instructions, refer to the Hardware
Installation chapter.
Figure A-27
CompactFlash Memory Card
Pin 1
Pin 50
LED Behavior
The 14 LEDs on the XSR front panel display system and port status as described in Table A-3. The
six system LEDs are illustrated to the left and the eight GigabitEthernet LEDs to the right in
Figure A-28. Note that Link and TX (transmit) green LEDs are provided for the GBIC (optical) port
while each GigabitEthernet port has one green and one amber LED.
Figure A-28
NIM1
NIM2
Link
SYS
XSR LEDs
1000
10/100/1000
10/100/1000
VPN
PWR
TX
COM
Table A-3
GBIC
ETH1
ETH2
ETH3
LED Description
LED
State
Function
NIM 1, NIM 2
ON
T1/E1, ISDN or HSSI card is present and powerup diagnostics test passed
OFF
NIM slot empty or power-up diagnostics test failed
ON
XSR is operational
OFF
Faulty hardware or Bootprom
Blinking
Flash update is in progress (software image
downloading), warning you not to power down the
XSR. Powering down now can leave the branch
router without valid software.
ON
XSR is powered up and Bootrom initialized
OFF
XSR is powered down
SYS(tem Status)
PWR
XSR Getting Started Guide A-21
Cable, CompactFlash and Accessory Specifications
Table A-3
LED
State
Function
VPN
ON
VPN tunnel is up
OFF
No VPN tunnel connected
Blinking
Port is transmitting or receiving data
OFF
Port is idle
Amber only ON
10Base-T link is auto-detected
Green only ON
100Base-T link is auto-detected
Both ON
1000Base-T link is auto-detected
Blinking
Port is transmitting or receiving data
OFF
Link is down
Both OFF
Port is configured as copper
Link LED ON
Fiber link up
TX LED
Blinking
Activity on fiber port
BRI NIM Port 0/1
Connected to
switch
BRI link is activated and ready for traffic.
This LED is located on the NIM card.
ADSL NIM 1
Blinking
Line is in training mode (syncing with DSLAM)
ON
Training mode complete, line is operational
OFF
Line is down
ADSL NIM 2
Blinking
Traffic activity in sync with data traffic
T3/E3 NIM:
•LOS (Loss of Signal)
•LOF (Loss of Frame)
•Alarm
•Enable
Red ON
Red ON
Amber ON
Green ON
XSR cannot latch onto the frequency
Both sides of link cannot synchronize frames
Error condition detected
Link is up and running
Copper Ethernet NIM
Link ON
Link OFF
Activity Blinking
100Base-T link is link is auto-detected
10Base-T link is link is auto-detected
Port is transmitting or receiving data
Fiber-optic Ethernet NIM
Link ON
Activity ON
100Base-F link is link is auto-detected
Port is transmitting or receiving data
COM(munication)
Ethernet Port 1, 2, 3
Fiber/Copper GBIC
(Ethernet) Port
A-22
LED Description (continued)
Index
B
Balun
description A-13
Balun adapter A-3
BRI S/T card
part numbers A-3
BRI S/Tpin assignments A-16
BRI U card
part numbers A-3
BRI-U pin assignments A-18, A-19,
A-20
Broadcom 1250 processor 1-2
C
cable/accessory guide A-2
cabling part numbers A-2
Canadian notices iii
channelized card specifications A-3
chassis
dimensions 1-2
specifications A-1
COM
port configuration A-4
port pinouts A-4
serial interface 1-3
session login A-4
session properties 3-3, A-4
session setup 3-3
CompactFlash
installation A-21
part numbers A-3
supported sizes A-1
using Monitor Mode command A-21
conditions causing reboots 3-34
configuration reset to factory
defaults 3-36
configuring RIP or OSPF 3-15
D
Dual-core processor
operating speed A-1
E
Enterasys
FTP site xvii
RMA number xvii
technical support tips xvii
environmental specifications A-1
Ethernet
cabling A-2
external power supply 1-2
F
fans 1-4
FastEthernet connectors 1-3
Frame Relay configuration 3-15
FTP
Enterasys Web site xvii
login xvii
password xvii
G
GBIC 1-3
GigaBitEthernet
port description A-5
GigabitEthernet 1-3
port pinouts A-5
Grounding shunt
description A-14
specifications A-3
H
hardware accelerator 1-3
Heat Dissipation A-1
High Speed Serial NIM port
pinouts A-7
how to configure the COM (console)
port A-4
how to get help xvii
I
initializing the XSR software 3-1
L
LAN port configuration 3-8
LEDs 1-4
behavior at startup 3-1
description A-21
M
Message logging
configuring logs and severity
levels 3-17
N
network
connector pin assignments A-5,
A-12, A-15
NIM cards 1-3, A-3
specifications A-2
Notices
Canadian iii
General ii, iii
null modem cable A-2, A-4
O
Onboard Flash
size 1-3, A-1
P
pin assignments
BRI S/T A-16
BRI-U A-18
COM serial port A-4
Ethernet (WAN) A-12, A-15
GigabitEthernet A-5
Pinouts
232/530 pinouts A-8
449 pinouts A-9
BRI S/T assignments A-16
BRI-U assignments A-18, A-19,
A-20
COM port A-7
GigabitEthernet port A-5
T1/E1 pinouts A-12
V.35 pinouts A-11
X.21 pinouts A-7
power
connecting the internal power supply
cord 2-12
specifications A-2
powering on the XSR 2-12
power-up diagnostics 3-2
power-up error conditions 3-35
PRI card
part numbers A-3
Processor
type A-1
R
RJ-45
connector pin assignments A-5,
A-12, A-15
S
sample configuration 3-20
SDRAM memory 1-3
SDRAM size A-1
serial link cabling A-3
SNMP
configuring a community string and
traps 3-16
system memory A-1
T
T1/E1 connectors A-12, A-15
U
UL notices iii
unchannelized card specifications A-3
W
WAN port
configuration 3-8
description A-12, A-15
Web access 3-18
X
X-Pedition Security Router
how to configure the XSR-1805
name and user data 3-7
XSR
232/530 pinouts A-8
449 pinouts A-9
COM port pinouts A-4
CompactFlash size A-1
Index-1
features 1-1
GigabitEthernet port pinouts A-5
hardware features 1-2
hardware specifications A-1
how to attach the Ethernet serial
cable 2-10
how to attach the internal power
supply cord 2-12
how to attach the serial Console
cable 2-7
how to attach the WAN cables 2-7
how to configure Frame Relay 3-15
how to configure IP routing 3-14
how to configure the COM port A-4
how to enable Web access 3-18
how to install a CompactFlash
card 2-5
how to install NIM cards 2-2
how to install the hardware 2-1
how to rack mount the XSR 2-2
how to set LAN ports 3-8
how to set up message logging 3-17
how to set up SNMP 3-16
how to set up the backup line 3-16
how to set WAN ports 3-8
initial login 3-3
installation overview 1-11
LED initialization sequence 3-1
Onboard RAM size A-1
opening a COM (console)
session 3-3
processor specs A-1
rebooting characteristics 3-33
sample configuration 3-20
SDRAM size A-1
software configuration overview 3-1
software features 1-4
system memory A-1
T1/E1 pinouts A-12
V.35 pinouts A-11
verifying your shipment 2-1
X.21 pinouts A-7
Index-2