SPECTRORADIOMETER CS-2000/CS-2000A Instruction Manual Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as a result of incorrect use of the instrument. Denotes a sentence regarding a safety warning or note. Read the sentence carefully to ensure safe and correct use. Denotes a prohibited operation. The operation must never been performed. Denotes an instruction. The instruction must be strictly adhered to. Denotes an instruction. Disconnect the AC adapter from the AC outlet. Denotes a prohibited operation. Never disassemble the instrument. Notes on This Manual Copying or reproduction of all or any part of the contents of this manual without KONICA MINOLTA's permission is strictly prohibited. The contents of this manual are subject to change without prior notice. Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. However, should you have any questions or find any errors, please contact the nearest KONICA MINOLTA-authorized service facility. KONICA MINOLTA will not accept any responsibility for consequences arising from the use of the instrument. Safety Precautions To ensure correct use of this instrument, read the following points carefully and adhere to them. After you have read this manual, keep it in a safe place where it can be referred to anytime a question arises. Warning (Failure to adhere to the following points may result in death or serious injury.) Do not use this instrument in places where flammable or combustible gases (gasoline etc.) are present. Doing so may cause fire. Always use the AC adapter and power cord supplied as a standard accessory or optional (AC-A312), and connect it to indoor AC outlet of rated voltage and frequency (100 - 120 V or 200 - 240 V , 50/60Hz). Failure to follow either of these may result in damage to unit, fire or electric shock. If this instrument is not used for a long time, disconnect AC adapter from AC outlet. Accumulated dirt or water on prongs of AC adapter plug may cause fire and should be removed. Do not forcibly pull any part on power cord when unplugging since this may cause fire or electric shock. Gently disconnect by holding plug. Also, do not handle power cord with wet hands. Doing so may cause electric shock. Do not forcibly bend, twist or pull power cord. Also, do not place heavy object on power cord, or damage or modify one. Any of these may cause fire or electric shock due to damage to power cord. Do not disassemble or modify this instrument or AC adapter. Doing so may cause fire or electric shock. Do not spill liquid on this instrument or drop metal into this instrument. Should either of these happen, switch power off, unplug AC adapter immediately and contact the nearest KONICA MINOLTA authorized service facility. Should this instrument or AC adapter be damaged or smoke or odd smell be generated, do not keep using such instrument or AC adapter without correction. Doing so may cause fire. In such situations, switch power off immediately, unplug AC adapter and contact the nearest KONICA MINOLTA authorized service facility. Do not look at sun or intense light through finder of this instrument. This may lose your sight. Caution (Failure to adhere to following points may result in injury or damage to this instrument or other property.) Use this instrument near AC outlet for easy plugging or unplugging in using AC adapter. Do not place this instrument on unstable or sloping surface which may drop or overturn it. Dropping or overturning may injure someone around. Take care not to drop this instrument when carrying it. Do not move while looking inside finder since this would fall or injure user. Take special care in handling the ND filter or closeup lens included in the optional accessories. Breakage of the ND filter or closeup lens may injure someone around. Introduction This instrument is a high-accuracy spectroradiometer designed to measure luminance and chromaticity up to super-low luminance regions. Carefully read this manual before using one. Packaging material Be sure to save all packaging materials (corrugated cardboard boxes, pads and plastic bags) supplied with the purchase. This is delicate measurement instrument. Use packaging materials supplied in purchasing in case this instrument needs to be transferred for such purpose as maintenance in KONICA MINOLTA's factories. These packaging materials are useful for minimizing shock or vibration to this instrument in such situation. Should any of these packaging materials be lost or broken, please contact the nearest KONICA MINOLTA authorized service facility. Note on Use Operating Environment The standard AC adapter (AC-A312) of this instrument is designed specifically for use indoors. Do not use it outdoors. Do not disassemble this instrument for being composed of delicate electronic components. Use this instrument at rated voltage of 100 V - 120 V or 200 V - 240 V (50/60Hz). Connect AC power cord to AC outlet with rated voltage and frequency. Connected voltage should not be outside the range of ±10% of nominal. This instrument is classified into a Pollution Degree 2 as instrument used in mainly in manufacturing plant, laboratory, warehouse or equivalents. Use this instrument in metal dust free and non condensing potential environment. This instrument is categorized into Installation Category II as equipment connected to commercially available power source. Connect PC for controlling this instrument to the outlet with protective grounding. Failure to follow this may result in electric shock due to short circuit. Take care not to enter foreign substance like water or metal in this instrument. Operating in such state cause serious danger. Do not use this instrument under direct sunlight or near heater. The internal temperature of this instrument to becomes much higher than ambient temperature which may break this instrument. Also, use this instrument in a well-ventilated place. To ensure proper heat dissipation, keep the ventilation holes free from obstructions. Avoid rapid change in ambient temperature which may form dew condensation. Avoid using this instrument in extremely dusty or humid place. Use the CS-2000 at ambient temperature between 5 and 35ºC and relative humidity 80% or less (at 35ºC) with no condensation. Use the CS-2000A at ambient temperature between 5 and 30ºC and relative humidity 80% or less (at 30ºC) with no condensation. Operating this instrument outside specified temperature and humidity range may not satisfy its original performance. This Instrument Do not subject this instrument to strong impact or vibration. Do not forcibly pull, bend, or apply strong force to power cord for attached AC adapter or USB cable. This may result in snapping. Connect this unit to power source with minimal noise. Do not measure a high-luminance light source (including sunlight) beyond the measurement range. The failure to observe this warning could result in damage to the optical system. Should breakage or abnormality be found during operation, switch power off immediately and unplug. Then refer to “Error Check” on page 82. Should this instrument break down, do not try to disassemble and repair it by yourself. Please contact the nearest KONICA MINOLTA authorized service facility. Warm this instrument up for 20 minutes at least after switching power on when the object luminance is 2 cd/m2 or lower (measuring angle 1º). Objective lens, ND filter and Closeup lens (Optional Accessories) Make sure that surfaces of objective lens, ND filter or closeup lens are clear. Correct measurement may not be performed if there is dirt, dust, hand soil or part left unclean. Do not touch surface of objective lens, ND filter or closeup lens with hand. Do not change ambient temperature rapidly under high humidity. This may mist objective lens, ND filter or closeup lens, resulting in incorrect measurement. Note on Storage Body Do not store this instrument under direct sunlight or near heater. The internal temperature of this instrument becomes much higher than ambient temperature which may break this instrument. Store this instrument at ambient temperature between 0 and 35ºC and relative humidity 80% or less (at 30ºC) with no condensation. Storage under high temperature and humidity may deteriorate performance of this instrument. For added safety, we recommend storage with such drying agent at room temperature. Take care not to form condensation. Avoid rapid change in ambient temperature when transferring body for storage. Put the body in a packaging box supplied when purchased or the storage case (CSA30) in the optional accessories to store in safe place. Objective lens For storage, cover the objective lens with standard accessory lens cap. Cleaning Body If this unit becomes dirty, wipe with dry and soft cloth. Do not use organic solvent like benzine or thinner and other chemical agent for cleaning. Should none of these methods be helpful, please contact the nearest KONICA MINOLTA authorized service facility. Objective lens Should it be gotten dirt or dust, wipe off with dry and soft cloth or lens cleaning paper. Do not use organic solvent like benzine or thinner and other chemical agent for cleaning. Should none of these methods be helpful, please contact the nearest KONICA MINOLTA authorized service facility. Notes on Transfer Use packaging material supplied when purchased to minimize vibration or shock generated during transfer. Put all material including unit and accessories in original packaging material when returning this instrument for service. Maintenance Periodical checkup is recommended annually to maintain measurement accuracy of instrument. For details on checkup, please contact the nearest KONICA MINOLTA authorized service facility. Disposal Method Make sure that the CS-2000/CS-2000A, its accessories and the packing materials are either disposed of or recycled correctly in accordance with local laws and regulations. Contents Safety Precautions… ………………… 1 Installation Introduction……………………………… 3 Installing… ……………………………… 20 Note on Use… …………………………… 3 Connecting AC Adapter… …………… 21 Operating Environment… ……………………… 3 Connection Method……………………… 22 This Instrument… ……………………………… 4 Power Switch ON( | )/OFF(O)………… 23 Objective lens, ND filter and Closeup lens (Optional Accessories)… ……………………… 4 Turning power switch ON… …………… 23 Note on Storage… ……………………… 4 Turning power switch OFF……………… 23 Body… …………………………………………… 4 Objective lens… ………………………………… 4 Setting Cleaning… ………………………………… 5 Setting of Synchronization…………… 26 Body… …………………………………………… 5 Selecting Measurement Time………… 29 Objective lens… ………………………………… 5 Notes on Transfer………………………… 5 Setting Observer… …………………… 35 Maintenance… …………………………… 5 Disposal Method… ……………………… 5 Selecting Display Format… ………… 37 Standard Accessories………………… 8 Selecting Color Space………………… 39 Optional Accessories… ……………… 9 Selecting Absolute Value (ABS)/ Difference (DIFF) Display… ………… 41 System Configuration… ……………… 11 When Using Closeup Lens…………… 43 Names and Functions of Parts… …… 12 Names of Each Part……………………… 12 When Using ND Filter… ……………… 45 Functions of Each Part… ……………… 13 Calibration… …………………………… 47 Key Panel… ……………………………… 14 Calibration Channel……………………… 47 Main Functions of Each Key…………… 14 Backlight ON/OFF During Diopter Adjustment……………………… 15 Measurement… ………………………… 49 LCD Screen… …………………………… 16 MEAS (Measurement value) screen… …… 16 MENU screen… ……………………………… 17 Measurement Measurement… ………………………… 52 Saving the Measurement Value……… 55 Deleting the Memory Data… ………… 58 Registering Target Color……………… 61 Target color… …………………………… 61 Selecting Target Color………………… 65 Deleting Target Color… ……………… 67 Communication Connecting to PC… …………………… 72 Remote Mode…………………………… 73 Explanation Measurement Principle… …………… 76 Sensor Section… …………………………… 76 Dark Measurement… ………………… 76 LvTΔuv… ………………………………… 77 Dominant wavelength/Excitation purity…… 78 Measurement of Object Color… …… 79 Necessary Setting for Object Color Measurement…… 79 White Calibration……………………………… 79 Measurement of Object……………………… 79 Dimensions……………………………… 80 Error Message… ……………………… 81 Error Check……………………………… 82 Setting Initialization… ………………… 85 Switching Luminance Unit… ………… 86 Main Specifications… ………………… 87 Standard Accessories Lens Cap CS-A31 Attached to objective lens for protecting it when not using this instrument. USB Cable (2 m) CS-A32 Used for communication between this instrument and PC. AC Adapter AC-A312 Supplies power from AC outlet. Input:100 - 120 V or 200 - 240 V 0.75 - 0.42 A 50/60 Hz Output:12 V 3A Data Management Software CS-S10w Professional Software to control this instrument from PC for various data management. The protect key is attached. Screw for focus ring lock CS-A38 Locks the focus adjustment ring of the CS2000/CS-2000A so that it does not move unintentionally and change the focus. · Do not use any screw except for the attached screw. Should it be lost or damaged, purchase a new CS-A38. · When storing the CS-2000/CS-2000A in the Storage Case (optional accessory), remove the screw. · When storing the CS-2000/CS-2000A in the packing box for transfer, remove the screw. Optional Accessories Calibration Certificate ND Eyepiece Filter CS-A1 Reduces glare during observation through the finder when a high-luminance object is measured. Be sure to place this filter in front of the finder when measuring highluminance objects. ND Filter (1/10) CS-A33 ND Filter (1/100) CS-A34 Placed in front of objective lens for measurement of high luminance object. Calibration Certificate (for ND filter) Calibration certificates can be attached to the ND filters (1/10) CS-A33 and (1/100) CSA34. Closeup Lens CS-A35 Placed in front of objective lens for measurement of small object. Adapter for CCD camera CS-A36 Placed between the finder and the body when a C-mount industrial camera is used. White Calibration Plate CS-A5 (without data) White Calibration Plate CS-A5 (with data) White Calibration Plate CS-A5 (with data and calibration certificate) Used for measurement of object colors. Three types (named, not-named, named with calibration certificate) are prepared. Tripod CS-A3 Pan Head CS-A4 Used when installing this instrument. Storage Case CS-A30 Used to house the instrument and accessories or to carry them by hand. Never use this as a transport case. 10 System Configuration Standard Accessories Optional Accessories Screw for Lens Cap focus ring lock CS-2000 Main Unit Calibration Certificate CS-A38 ND Eyepiece Filter CS-A1 ND Filter (1/10) CS-A33 (1/100) CS-A34 Calibration Certificate (for ND filter) AC Adapter AC-A312 Adapter for CCD camera CS-A36 Closeup Lens CS-A35 USB Cable (2 m) CS-A32 White Calibration Plate CS-A5 (w/o data) CS-A5 (w/ data) CS-A5 (w/ data and calibration certificate) Pan Head CS-A4 Tripod CS-A3 Storage Case CS-A30 11 PC (on the market) Data Management Software CS-S10w Professional Names and Functions of Parts Names of Each Part (7) Focus distance scale Handle (6) Focus adjustment ring (1) Power switch (2) AC adapter input terminal (5) Objective lens (14) Screw holes for fixing (8) LCD screen (10) Measurement button (3) USB connector (9) Key panel (15) Vertically synchronized signal input terminal (12) Diopter adjustment ring (4) Measuring angle selector Inside finder (13) Aperture (11) Finder 12 Functions of Each Part (1) Power switch Switches this instrument on/off. ( | ) for ON; (O) for OFF.……(p.23) (2) AC adapter input terminal Connects the attached AC adapter.… ……………………… (p.21) (3) USB connector Connects the USB cable when connecting to PC.… ……… (p.72) (4) Measuring angle selector Selects measurement angle among 1º, 0.2º and 0.1º.…………(p.52) (5) Objective lens Directed to object for measurement.… ………………………(p.53) (6)Focus adjustment ring Adjusts focus of objective lens before measurement.………(p.53) (7) Focus distance scale Helps adjusting focus.… ………………………………………(p.53) (8) LCD Screen Displays various screens like measurement and menu.… … (p.16) (9) Key Panel Offers several keys for operation of this instrument.… …… (p.14) (10)Measurement button For measurement.………………………………………………(p.53) (11) Finder Used to observe object for measurement.… ………… (p.15, 53) (12) Diopter adjustment ring Adjusts diopter.… ………………………………………… (p.15, 53) (13)Aperture Indicates measuring area.… …………………………………(p.53) Size of black circle will change depending on measuring angle. 1º Aperture 0.2º Aperture 0.1º Aperture (14) Screw holes for fixing Used to fix this instrument with tripod or jig.… …………… (p.20) (15) Vertically synchronized signal input terminal Connects the cable to input the vertically synchronized signal or the external sync measurement.… ……………… (p.26) 13 Key Panel (1) (4) (2) (5) (3) (6 ) (7) Main Functions of Each Key (1) MENU key The MENU screen appears if this key pressed when the measurement value screen appears. (p.17) (2) DISPLAY key Selects whether chromaticity is displayed in absolute value (ABS) or difference (DIFF) if this key pressed when the measurement value screen appears. (p.41) (3) COLOR MODE key Color space modes are switched in turn as follows, by pressing the key when the measurement value screen appears: Lvxy Lvu’v’ LvTΔuv XYZ Dominant wavelength/Excitation purity Spectral graph Lvxy. (p.39) (4) ESC key If this key is pressed when the MENU screen is displayed, the settings are canceled and the measurement value screen appears again. If pressed during numerical input or when making each setting, the settings are canceled. If pressed during continuous measurement, the measurement ends. (5) BACKLIGHT key Selects backlight ON/OFF on LCD screen. (p.49) (6) MEMORY key Measured data is stored in memory by pressing this key when the measurement value screen appears. (p.55) (7) keys Memory data, target color channels, calibration channels, etc., are changed by pressing the key when the screen for display of various data appears. The cursor position is moved up and down, or the values and set items are changed, by pressing the key during numerical input or when making each setting. keys The cursor position moves right and left by pressing the key for numerical input or when making each setting. ENTER key Press the key to fix the contents selected in 14 . Diopter Adjustment Rotate the diopter adjustment ring for adjustment of diopter. Diopter adjustment ring Adjust so that A or B on aperture or black circle indicating measuring area looks clear when observing object through finder. Adjustment would be easy starting with 1º aperture where object near aperture looks blur. A Make sure to adjust diopter before measurement. Diopter should be adjusted for the eyesight of the person who will be taking measurement. If diopter is not adjusted before focus measurement, correct measurement value may not be expected. This is because the focus is actually off even if you think it is correctly in focus. In addition, if diopter is not correctly adjusted, you may see the aperture moving depending on viewing angle. B *Y ou sometimes see small black dots or stripes in internal finder. It gives no effect on measuring performance. 15 LCD Screen MEAS (Measurement value) screen “SNGL” is displayed for the values obtained during single measurement, while “CONT” is displayed for the values obtained during continuous measurement. (p.53) MEAS Lv SNGL Calibration channel (p.47) Target color channel (p.61, 65, 67) UC00 T01 80. 00 x 0 . 0000 y 0 . 0000 Measurement result is displayed in the currently selected color space. (Lvxy, Lvu’v’, LvTΔuv, XYZ, Dominant wavelength/Excitation purity, Spectral graph) (p.39) Display format can be changed. (p.37) cd m2 Obs SPD SYNC L E N ND 10˚ M-N N o n C-U 100 BL on Setting status in this instrument is displayed. <Obs> <SPD> <SYNC> Currently selected observer angle is displayed. (2°,10°) (p.35) Currently selected measuring time is displayed. (Nrm, Fst, M-N, M-F, Mnl) (p.29) “Int” is displayed when the internal sync measurement mode is set. “Ext” is displayed when the external sync measurement mode. “Non” is displayed when the sync measurement mode is not set. (p.26) 16 MENU screen The MENU screen appears if MENU key is pressed when the measurement value screen is displayed. MEAS Used to set measurement time or synchronizing method. (p.26, 29) MEMORY Used to read or delete the measurement memory data. (p.56, 58) MENU MEAS TARGET MEMORY Used to register, select or delete the target color. (p.61, 65, 67) TARGET OPTION OPTION SETUP Used to set the closeup lens, ND filter or calibration channel. (p.43, 45, 47) SETUP Used to set the observer, backlight or display format. (p.35, 49, 37) <LENS> <ND> <BL> “C-U” is displayed, if the closeup lens is attached. If not, “Std” is displayed (p.43). The current ND filter type is displayed. (Non, 10, 100) (p.45) “On” is displayed, if the backlight is set to be turned on during the measurement. “Off” is displayed, if the backlight is set to be turned off during that time. (p.49) 17 18 Installation 19 Installation Installing Use screw holes for fixing at the bottom of this instrument if utilized with the tripod or jig. 2-type holes are available. Tripod screw hole:To set on the tripod. Use a tripod screw with top diameter of 3/8 inches and depth of 10.5 mm. [Note] The tripod screw holes correspond with the 3/8-inch screws of a large camera tripod. 1/4-inch screws cannot be used for fixing this instrument. ISO screw hole:To set on the jig. Use ISO screws with top diameter of 5 mm and depth of 6.5 mm. Measurement distance reference ISO screw Tripod screw Optical axis 70 170 190.4 For other detailed dimensions, see p.80. 20 ISO screw The AC adapter supplied with this instrument is used for the corresponding power source. Warning (Failure to adhere to the following points may result in death or serious injury.) Always use the AC adapter and power cord supplied as a standard accessory or optional accessory (AC-A312), and connect it to indoor AC outlet of rated voltage and frequency (100 - 120 V or 200 - 240 V , 50/60Hz). Failure to follow either of these may result in damage to unit, fire or electric shock. If this instrument is not used for a long time, disconnect AC adapter from AC outlet. Accumulated dirt or water on prongs of AC adapter plug may cause fire and should be removed before use. Do not forcibly pull any part on power cord when unplugging since this may cause fire or electric shock. Gently disconnect by holding plug. Also, do not handle power cord with wet hands. Doing so may cause electric shock. Do not forcibly bend, twist or pull power cord. Also, do not place heavy object on power cord, or damage or modify one. Any of these may cause fire or electric shock due to damage to power cord. Do not disassemble or modify this instrument or AC adapter. Doing so may cause fire or electric shock. Should this instrument or AC adapter be damaged or smoke or odd smell be generated, do not keep using such instrument or AC adapter without correction. Doing so may cause fire. In such situations, switch power off immediately, unplug AC adapter and contact the nearest KONICA MINOLTA authorized service facility. Caution (Failure to adhere to following points may result in injury or damage to this instrument or other property.) Use this instrument near AC outlet for easy plugging or unplugging in using AC adapter. 21 Installation Connecting AC Adapter Installation Connection Method 1. 2. 3. Make sure that power switch is OFF (slided to [O] side). Connect the AC adapter plug to the AC adapter input terminal of the body. Plug the AC adapter to outlet (100 - 120 VAC 50 Hz/60 Hz). Insert the AC adapter plug all the way seated in AC outlet. 22 or 200 - 240 VAC , The warm-up time needed is a minimum of 20 minutes in order to measure the objects with excellent accuracy under the conditions described below. Warm up this instrument for 20 or more minutes when the power source is turned off even for a short period, and turned on again. (1) The object is a low-luminance light source, using 2856 K (standard light source A) as a guide: 2 cd/m2 or lower (1° Aperture) 50 cd/m2 or lower (0.2° Aperture) 200 cd/m2 or lower (0.1° Aperture) (2) Outside room temperature and normal humidity ranges Turning power switch ON 1. Slide power switch to ON ( | ) side. The measurement screen appears 5 seconds after the initial screen on the LCD. T he model type (CS-2000 or CS2000A), body version and product serial numbers are displayed on the initial screen. The model type can be also confirmed on the nameplate. Turning power switch OFF 2. Slide power switch to OFF (O side) after measurement. 23 Installation Power Switch ON( | )/OFF(O) 24 Setting 25 Setting Setting of Synchronization The synchronized measurement refers to measurement mode where measurement is made in the same timing as periodical light source pulse frequency, such as vertically synchronized frequency for the display device. [INT SYNC] The internal sync measurement mode is used to measure the display equipment without the input of vertically synchronized signals to the body, or to measure flicker light from a light source such as a fluorescent light. Input the frequency of vertically synchronized signals for the display equipment, or the commercial frequency (50 or 60 Hz) for flicker light from a light source such as a luminescent light. The optimal integration time is automatically set based on the input value and the brightness of the object. For this reason, enter the correct frequency value to two places of decimals. However, if the vertically synchronized frequency of the display equipment is not clear, accurate measurement will not be possible with an inaccurate frequency setting. In this case it is recommended to select [NO SYNC] mode without sync measurement (at 60 Hz of frequency), but to select [MULTI-NORMAL] mode or [MULTI-FAST] mode for the measurement time (refer to p. 29). [EXT SYNC] The external sync measurement mode is used to measure the display equipment after the line input of a vertically synchronized signal through the input terminal for vertically synchronized signals to the body. The optimal integration time is set automatically, based on the frequency of vertically synchronized signals and the brightness of the object.Input CMOS (5V) Level of the input signals. * Range of synchronized frequencies * Factory default setting : NO SYNC Operation Procedure : 20.00 to 200.00 Hz 6, 7 1 2, 3, 4, 5 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv 35. 93 x 0 . 3968 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n MENU MEAS MEMORY TARGET OPTION SETUP 26 UC00 T01 Press either or key to select [MEAS] and then press ENTER key. The MENU – MEAS screen appears. MENU MEAS SPEED NORMAL SYNC NO SYNC The current set contents are displayed in the SYNC item. 3. Press either or key to select [SYNC] and then press ENTER key. The MENU - MEAS - SYNC MODE (sync method selection) screen appears. 4. Press either or INT SYNC setting: Select [INT SYNC] and press ENTER key. Press either value. SYNC INT SYNC EXT SYNC MENU MEAS SYNC MODE NO The MENU - MEAS - SYNC MODE – INT SYNC screen appears. This screen is used for the input of an internal synchronized frequency. 4-a-2. NO key to select the sync method. 4-a-1. MENU MEAS SYNC MODE or SYNC INT SYNC EXT SYNC MENU MEAS SYNC MODE I N T SYNC 060.00 Hz key to set a key for larger number. key for smaller number. The range of the internal synchronized frequency is from 20 Hz to 200 Hz. 4-a-3. Press either the cursor. or key to move MENU MEAS SYNC MODE I N T SYNC 050.00 27 Hz Setting 2. Setting 4-a-4. 4-a-5. Repeat the same procedures 4-a2. and -3. as necessary. Press ENTER key. After the setting is entered, the MENU MEAS - SYNC MODE screen appears again on the LCD. 5. Press ENTER key. When the synchronizing method is set, the MENU - MEAS screen appears again on the LCD. By pressing ESC key, after the setting is canceled the MENU - MEAS screen appears again on the LCD. The setting of the synchronizing method is saved even after the power switch is turned off (O). 6. Press ENTER key. The MENU screen appears again on the LCD. 7. Press ESC key. MEAS The MEAS screen appears again on the LCD. Lv SNGL UC00 T01 35. 93 x 0 . 3968 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m I n t S t d N o n o n 28 Selecting Measurement Time Select measurement time according to the purpose. Five modes are available for measurement time. Examples of measurement subjects Operation explanation Feature Cautions In this mode, integration time*1 is adjusted between 0.005s and 120s according to the brightness of the measurement subject. This mode emphasizes performance when measuring low luminances. Improved accuracy and repeatability for luminances below approx. 4 cd/m2 (measurement angle: 1°) When measuring low luminances, since the total measurement time can be as long as 4 minutes, if the brightness of the measurement subject changes, the measurement results will be the average luminance. In addition, be careful to not move the instrument during measurement. When measuring periodic light sources, MULTI INTEG-NORMAL mode or MULTI INTEG-FAST mode may be more suitable, for example, when the synchronization frequency is unknown. Constant light sources (halogen lamps, etc.) Shorter measuring times for luminances below approx. 4 cd/m2 (measurement angle: 1°) When higher accuracy and repeatability are required at low luminances, the NORMAL mode should be used if necessary. Same as above FAST In this mode, integration time is adjusted between 0.005s and 16s according to the brightness of the measurement subject. This mode emphasizes measurement time when measuring low luminances. MULTI INTEGNORMAL In this mode, several cycles of the integration time for NORMAL mode are taken and averaged. Under luminance conditions which require an integration time longer than the set luminance, the integration time will be the same as for normal measurement. This mode can be used when the synchronization time for measurement is unknown or when the synchronization time is known but the frequency is unstable. In such case, the sync mode should be set to NO SYNC. Measurements which do Even for high luminances, not depend on the the set integration time (1s or synchronization longer) will be used. frequency of the measurement subject can be taken. Improved accuracy and repeatability for luminances below approx. 4 cd/m2 (measurement angle: 1°) Periodic light sources (whose synchronization frequency is unknown or unstable) MULTI INTEGFAST In this mode, several cycles of the integration time for FAST mode are taken and averaged. Under luminance conditions which require an integration time longer than the set luminance, the integration time will be the same as for FAST measurement. This mode can be used when the synchronization time for measurement is unknown or when the synchronization time is known but the frequency is unstable. In such case, the sync mode should be set to NO SYNC. Measurements which do Even for high luminances, not depend on the the set integration time (1s or synchronization longer) will be used frequency of the measurement subject can be taken. Shorter measuring times for luminances below approx. 4 cd/m2 (measurement angle: 1°) Periodic light sources (whose synchronization frequency is unknown or unstable) MANUAL This mode can be used when you want to set a fixed integration time for measurements. Integration time: 0.005s to 120s The desired fixed integration Be careful that the “OVER” error All light sources time can be set. message does not occur and that the measurement accuracy is not reduced. NORMAL Periodic light sources (whose are stable and whose synchronization frequency is known) *1 Time for sensor to measure light indicating “exposure time”. On the other hand, measurement time shows time for integration × 2 +Time to open/close shutter + Time for calculation), indicating time needed for actual measurement. * Factory default setting : MULTI INTEG-NORMAL, IN-ND : AUTO 29 Setting Measurement time mode Operation Procedure 6, 7 1 Setting 2, 3, 4, 5 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv UC00 T01 cd m2 35. 85 x 0 . 3964 y 0 . 4059 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n MENU MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [MEAS] and then press ENTER key. The MENU – MEAS screen appears. MENU MEAS SPEED SYNC NORMAL NO SYNC The current set contents are displayed in the SPEED item. 3. Press either or key to select [SPEED] and then press ENTER key. The MENU - MEAS - SPEED MODE (measurement speed setting) screen appears. MENU MEAS S P E E D MODE NORMAL FAST MULTI- N O R M A L MULTI- F A S T MANUAL 30 4. Press either or key to select measurement speed. MENU MEAS S P E E D MODE NORMAL FAST MULTI- F A S T MANUAL 4-a-1.NORMAL or FAST setting: Select [NORMAL] or [FAST] and press ENTER key. The MENU - MEAS - SPEED MODE - INND screen appears. MENU MEAS S P E E D MODE IN ND AUTO OFF ON This screen is used to determine whether the ND filter built into the body is used or not. 4-a-2. Press either or key to select [AUTO], [OFF] or [ON]. Select [ON] when the error message “OVER” appears. 4-a-3. When measuring objects having a wide range of luminance under the adjusted measurement conditions (ex. γ measurement), set IN-ND to [OFF] or [ON]. For [OFF] or [ON] selection, select [OFF] when the upper limit luminance is 100cd/ m2 or less, and [ON] when it is 100cd/m2 or more as a guide. Press ENTER key. After the setting is entered, the MENU - MEAS - SPEED MODE screen appears again on the LCD. MENU MEAS S P E E D MODE IN ND AUTO OFF ON MENU MEAS S P E E D MODE NORMAL FAST MULTI- N O R M A L MULTI- F A S T MANUAL 4-b-1. MULTI-NORMAL or MULTI-FAST setting: Select [MULTI-NORMAL] or [MULTIFAST] and press ENTER key. The MENU - MEAS - SPEED MODE MULTI INTEG screen appears. This screen is used for input of the integration time in the MULTI INTEG-NORMAL mode or MULTI INTEG-FAST mode. 31 MENU MEAS S P E E D MODE MULTI INTEG INTEG TIME 01 IN-ND AUTO Setting MULTI- N O R M A L 4-b-2. Press either value. or key to set a INTEG key for larger number. Setting The setting range of integration time is from 1 to 16 s. Press ENTER key. The cursor moves to the IN-ND item. This screen is used to determine whether the ND filter built into the body is used or not. 4-b-4. Press either or key to select [AUTO], [OFF] or [ON]. Select [ON] when the error message “OVER” appears. 4-b-5. TIME 10 key for smaller number. 4-b-3. MENU MEAS S P E E D MODE MULTI INTEG When measuring objects having a wide range of luminance under the adjusted measurement conditions (ex. γ measurement), set IN-ND to [OFF] or [ON]. For [OFF] or [ON] selection, select [OFF] when the upper limit luminance is 100cd/ m2 or less, and [ON] when it is 100cd/m2 or more as a guide. IN-ND AUTO MENU MEAS S P E E D MODE MULTI INTEG INTEG TIME 10 IN-ND AUTO MENU MEAS S P E E D MODE MULTI INTEG INTEG TIME 10 IN-ND ON MENU MEAS S P E E D MODE Press ENTER key. After the setting is entered, the MENU MEAS - SPEED MODE screen appears again on the LCD. NORMAL FAST MULTI- N O R M A L MULTI- F A S T MANUAL 4-c-1. MANUAL setting: Select [MANUAL] and press ENTER key. The MENU - MEAS – SPEED MODE MANUAL screen appears. This screen is used for input of the integration time in the manual mode. MENU MEAS S P E E D MODE NORMAL FAST MULTI- N O R M A L MULTI- F A S T MANUAL MENU MEAS S P E E D MODE MANUAL INTEG TIME 000033.333 I N- N D 32 ms OFF Press either value. or key to set a key for larger number. INTEG key for smaller number. 000033.330 The setting range of integration time is from 5 to 120,000 ms. 4-c-3. 4-c-4. MENU MEAS S P E E D MODE MANUAL Press either the cursor. or TIME I N- N D key to move Repeat the same procedures 4-a2. and -3. as necessary. MENU MEAS S P E E D MODE MANUAL INTEG TIME 000500.000 I N- N D 4-c-5. Press ENTER key. The cursor moves to the IN-ND item. This screen is used to determine whether the ND filter built into the body is used or not. 4-c-6. Press either or [ON] or [OFF]. key to select Select [ON] when the error message “OVER” appears. 4-c-7. ms OFF Setting 4-c-2. Press ENTER key. When the setting is entered, the MENU MEAS - SPEED MODE screen appears again on the LCD. MENU MEAS S P E E D MODE MANUAL INTEG TIME 000500.000 I N- N D ms OFF MENU MEAS S P E E D MODE MANUAL INTEG TIME 000500.000 I N- N D ms ON MENU MEAS S P E E D MODE NORMAL FAST M U L T I - NORMAL M U L T I - FAST MANUAL 33 ms OFF 5. Press ENTER key. When the measurement time is set, the MENU MEAS screen appears again on the LCD. Setting By pressing ESC key, after the setting is canceled the MENU - MEAS screen appears again on the LCD. Measurement time setting is saved even after switching OFF (O). 6. Press ESC key. The MENU screen appears again on the LCD. 7. Press ESC key. MEAS The MEAS screen appears again on the LCD. Lv SNGL UC00 T01 35. 85 x 0 . 3964 y 0 . 4059 cd m2 Obs SPD SYNC L E N ND BL 2˚ Mnl N o n S t d N o n o n 34 Setting Observer Color matching function for chromaticity calculation is selectable between 2°OBS and 10°OBS. * Observer setting : 2°OBS, 10°OBS * Factory default setting : 2°OBS Operation Procedure Setting 8, 9 1 2, 3, 4, 5, 6, 7 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv UC00 T01 35. 85 x 0 . 3964 y 0 . 4059 cd m2 Obs SPD SYNC L E N ND BL 2˚ Mnl N o n S t d N o n o n MENU MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [SETUP] and then press ENTER key. The MENU – SETUP screen appears. The current set contents are displayed in the [OBSERVER] item. 3. Press either or key to select [OBSERVER] and then press ENTER key. The MENU - SETUP – OBSERVER (Observer selection) screen appears. 35 MENU SETUP OBSERVER 2° B A C K L I G H T @ MEAS ON DATA FORM MENU SETUP OBSERVER 2° O B S 10 ° O B S F 4. Press either or OBS] or [10º OBS]. key to select [2º MENU SETUP OBSERVER 2° O B S Setting 10 ° O B S 5. Press ENTER key. MENU SETUP OBSERVER The confirmation screen appears. [CANCEL] is selected. CHANGE OK 6. Press [OK]. key to move the cursor to CANCEL MENU SETUP OBSERVER CHANGE OK 7. CANCEL Press ENTER key. When the observer angle is set, the MENU MEAS screen appears again on the LCD. By pressing ESC key, after the setting is canceled the MENU - SETUP screen appears again on the LCD. Observer setting is saved even after switching OFF (O). 8. Press ESC key. The MENU screen appears again on the LCD. 9. MEAS Press ESC key. The MEAS screen appears again on the LCD. When observer angle is set to 10°, Lv display changes to Y display. Lv SNGL UC00 T01 35. 85 x 0 . 3964 y 0 . 4059 cd m2 Obs SPD SYNC L E N ND BL 10˚ Mnl N o n S t d N o n o n 36 Selecting Display Format The formats of indicating the luminance and excitation values X, Y and Z can be selected as either normal indication to display the values to four places of decimals, or as index number indication. If the measurement values on the LCD are unreadable, use the index number indication. * Display format setting : Normal, Index * When the number of displayed digits is six (luminance and X/Y/Z are 100000 or more) in the normal indication, “******.*****” will be displayed. In this case, the value will be displayed if you set to the index number indication. Operation Procedure 6, 7 1 2, 3, 4, 5 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv UC00 T01 35. 85 x 0 . 3964 y 0 . 4059 cd m2 Obs SPD SYNC L E N ND BL 2˚ Mnl N o n S t d N o n o n MENU MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [SETUP] and then press ENTER key. The MENU – SETUP screen appears. The current set contents are displayed in the [DATA FORM] item. 3. Press either or key to select [DATA FORM] and then press ENTER key. The MENU - SETUP - DATA FORM (Display format selection) screen appears. 37 MENU SETUP OBSERVER 2° B A C K L I G H T @ MEAS ON DATA FORM MENU SETUP DATA F O R M **** . **** * . ****E +* F Setting * Factory default setting : ****.**** [F] Setting 4. 5. 6. 7. Press either or key to select [****.**** [F]] or [*.****E+* [E]]. MENU SETUP DATA F O R M **** . **** * . ****E +* Press ENTER key. MENU SETUP When the display format is set, the MENU SETUP screen appears again on the LCD. By pressing ESC key, after the setting is canceled the MENU - SETUP screen appears again on the LCD. Display format setting is saved even after switching OFF (O). OBSERVER 2° B A C K L I G H T @ MEAS ON DATA FORM E Press ESC key. The MENU screen appears again on the LCD. Press ESC key. MEAS The MEAS screen appears again on the LCD. SNGL UC00 T01 Lv 3. 5846E+1 x 0. 3964 y 0. 4059 cd m2 Obs SPD SYNC L E N ND BL 2˚ Mnl N o n S t d N o n o n 38 Selecting Color Space See below table for available color space. * Factory default setting :Lvxy Lvxy *1 LCD Screen (When Normal is selected for display format) (When Index is selected for display format) MEAS Lv SNGL UC00 T01 34 . 22 x 0 . 3958 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Lv u’v’ *1 MEAS Lv SNGL UC00 T01 34 . 22 u’ 0 . 2236 v’ 0 . 5161 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Lv T ∆uv MEAS Lv T duv SNGL UC00 T01 34 . 22 cd m2 3829K MEAS SNGL UC00 T01 UC00 T01 3 . 4221E+1 x 0 . 3958 y 0 . 4060 MEAS SNGL UC00 T01 Lv 3 . 4221E+1 u’ 0 . 2236 v’ 0 . 5161 MEAS SNGL UC00 T01 Lv 3 . 4221E+1 T 3829K MEAS SNGL UC00 T01 Y 34 . 22 Y 3 . 4221E+1 Z 16 . 71 Z 1 . 6709E+1 Displays and outputs in luminance Lv and u’v’ chromaticity diagram (CIE 1976 UCS chromaticity diagram) coordinates u’, v’. Displays and outputs in luminance Lv, correlated color temperature T and color difference from blackbody locus ∆uv. Displays and outputs in tristimulus values X, Y, Z. Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n UC00 T01 +576 . 220nm Pe cd m2 +0. 009 3 . 3365E+1 λd Displays and outputs in luminance Lv and chromaticity coordinates x,y. Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n X SNGL cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n 33 . 36 MEAS cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n X Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Dominant wavelength/ Excitation purity *2 SNGL Lv duv +0. 009 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n XYZ MEAS Display Description 0 . 407% Displays and outputs in dominant wavelength λd and excitation purity Pe. Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Spectral graph MEAS SNGL UC00 T01 380nm 380 780 1 . 3118E- 5 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n 39 Displays or outputs spectral radiance Le (λ) in the spectral waveform Setting Color Space Setting *1 Y is displayed instead of Lv when observer angle is 10°. *2 For non-spectral colors, the complementary wavelength will be displayed. The display indication will remain λd. *If the calculated value does not establish a proper combination with the value in the color space mode, “_ _ _ _ _ _ _ _” will be displayed. Operation Procedure 1 2 1. 2. When the MENU or MEMORY screen is displayed, press ESC key to switch to the MEAS screen. MEAS Lv SNGL UC00 T01 34 . 22 x 0 . 3958 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Press COLOR MODE key to display the desired color space. Measurement screen switches in order of Lvxy Lvu’v’ LvT∆uv XYZ λd/Pe Spectral graph Lvxy while COLOR MODE key is pressed. It switches in order of Yxy Yu’v’ XYZ λd/ Pe Spectral graph Yxy when observer angle is 10°. Color space setting is saved even after switching OFF (O). 40 MEAS Lv SNGL UC00 T01 34 . 22 u’ 0 . 2236 v’ 0 . 5161 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Selecting Absolute Value (ABS)/Difference (DIFF) Display Whether chromaticity value is shown in absolute (ABS) or difference (DIFF) is selectable. See below table for each case. * Factory default setting: Absolute value (ABS) Absolute value (ABS) Lv, x , y MEAS Lv SNGL UC00 T01 34 . 22 x 0 . 3958 y 0 . 4060 cd m2 Lv, u’, v’ MEAS Lv SNGL UC00 T01 34 . 22 MEAS Lv x y cd m2 UC00 T01 + 0 . 1188 100 . 35% - 0 . 0000 - 0 . 0001 cd 2 m cd 2 m Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Lv, u’, v’ %Lv, ∆Lv, ∆u’, ∆v’ MEAS u’ 0 . 2236 Lv u’ v’ v’ 0 . 5161 Lv %Lv u’ v’ Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n SNGL 34 . 34 0 . 3958 0 . 4059 Lv %Lv x. y. Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Lv u’v’ *1 Difference (DIFF) Lv, x, y ∆Lv, %LV, ∆x, ∆y SNGL UC00 T01 34 . 34 0 . 2236 0 . 5160 + 0 . 1188 100 . 35% + 0 . 0000 - 0 . 0000 cd 2 m cd 2 m Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Lv T ∆uv Lv, T, duv MEAS Lv SNGL UC00 T01 34 . 22 T cd m2 3829K duv +0. 009 Lv, T, duv ∆Lv, %Lv, ∆T MEAS SNGL UC00 T01 Lv T duv 34 . 34 3830K + 0 . 009 cd 2 m Lv %Lv T + 0 . 1188 100 . 35% OK cd 2 m Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n XYZ X, Y, Z MEAS SNGL UC00 T01 X 33 . 36 Y 34 . 22 Z 16 . 71 X, Y, Z ∆X, ∆Y, ∆Z %X, %Y, %Z MEAS X Y Z Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n SNGL UC00 T01 33 . 49 34 . 34 16 . 78 + 0 . 1204 + 0 . 1188 + 0 . 07479 100 . 36% 100 . 35% 100 . 45% X Y Z X% Y% Z% Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Dominant wavelength λ d, Pe MEAS λd Pe SNGL UC00 T01 +576 . 220nm λd Pe ∆λd, ∆Pe *2 MEAS λd Fe 0 . 407% λd Pe SNGL UC00 T01 + 576 . 220 nm 0 . 406 0 . 0 0 0 nm - 0 . 000% Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n 41 Setting Color Space Lvxy *1 Color Space Spectral graph Absolute value (ABS) Difference (DIFF) Le (λ) spectral waveform Measurement value and Le (λ) Wavelength at the cursor position spectral waveform of target color and Le (λ) in the wavelength Wavelength of the cursor position MEAS SNGL UC00 T01 and Le (λ) of the measurement value in the wavelength Setting MEAS SNGL UC00 T01 380nm 380 780 1 . 3118E- 5 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n 380nm 380 780 +1 . 8 7 0 4 E - 7 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n *1 Y is displayed instead of Lv when observer angle is 10°. *2Even if either the measured value, target color, or both are the complementary wavelength, the difference between the two values will be displayed. The display indication will remain ∆λd. *If the calculated value or the registered target color does not establish a proper combination with the value in the color space mode, “_ _ _ _ _ _ _ _” will be displayed. Operation Procedure 1 2 1. 2. When the MENU or MEMORY screen is displayed, press ESC key to switch to the MEAS screen. MEAS Lv SNGL UC00 T01 34 . 22 x 0 . 3958 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Press DISPLAY key to show absolute value (ABS) or color difference (DIFF) to select. MEAS Lv x y Measurement value switches between that for absolute value (ABS) and difference (DIFF) while DISPLAY key is pressed. The setting of absolute value (ABS) and difference (DIFF) is saved even after switching OFF (O). 42 Lv %Lv x. y. SNGL UC00 T01 34 . 34 0 . 3958 0 . 4059 + 0 . 1188 100 . 35% - 0 . 0000 - 0 . 0001 cd 2 m cd 2 m Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o n Use the closeup lens in the optional accessories to measure a fine surface. For the attachment of the closeup lens, refer to the instruction manual for the closeup lens. If the closeup lens is attached, the measurement value must be compensated for the lens transmittance. This compensation coefficient is attached to the closeup lens. Use the data management software CS-S10w Professional supplied with the CS-2000 as standard to set the coefficient in this instrument. After that, when the closeup lens is selected as lens type, the measurement value compensated with the compensation coefficient can be obtained. See instruction manual of CS-S10w for details. The wrong setting of lens type leads to inaccurate measurement. Do not use the closeup lens with the ND filter. It leads to inaccurate measurement. * Lens type : STANDARD, CLOSE-UP * Factory default setting : STANDARD Operation Procedure 6, 7 1 2, 3, 4, 5 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv UC00 T01 35. 93 x 0 . 3968 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m I n t S t d N o n o n MENU MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [OPTION] and then press ENTER key. The MENU – OPTION screen appears. The current set contents are displayed in the [LENS] item. 43 MENU OPTION USER. CAL NON LENS STD ND-F I L T E R NON Setting When Using Closeup Lens 3. Press either or key to select [LENS] and then press ENTER key. MENU OPTION LENS STANDARD Setting The MENU - SETUP – LENS (Lens type selection) screen appears. 4. Press either [CLOSE-UP]. or CLOSE- UP key to select MENU OPTION LENS STANDARD When you removed the closeup lens, select [STANDARD]. 5. CLOSE- UP Press ENTER key. MENU OPTION When the lens type is set, the MENU - OPTION screen appears again on the LCD. USER. CAL By pressing ESC key, after the setting is canceled the MENU - OPTION screen appears again on the LCD. ND-F I L T E R NON C- UP LENS NON Lens type setting is saved even after switching OFF (O). 6. Press ESC key. The MENU screen appears again on the LCD. 7. Press ESC key. MEAS The MEAS screen appears again on the LCD. Lv SNGL UC00 T01 35. 93 x 0 . 3968 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m I n t C- U N o n o n 44 Use the ND filter in the optional accessories when measuring a high-luminance object. If the ND filter is attached, the measurement value must be compensated for the filter transmittance. This compensation coefficient is attached to the ND filter. Use the data management software CS-S10w Professional supplied with the CS-2000 as standard to set the coefficient in this instrument. After that, when the ND filter is selected, the measurement value compensated with the compensation coefficient can be obtained. See instruction manual of CS-S10w for details. The wrong setting of ND filter leads to inaccurate measurement. Do not use the ND filter with the closeup lens. It leads to inaccurate measurement. Note that an extra ND filter is built into this instrument. There are three setting options for use or non-use of this built-in ND filter: [AUTO] for switching automatically depending on the luminance of the object, [OFF] for constant non-use, and [ON] for constant use (See p.31 to p.33). * ND-FILTER : NONE, ND10, ND100 * Factory default setting : NONE Operation Procedure 6, 7 1 2, 3, 4, 5 1. Press MENU key when the MEAS screen is displayed. Lv The MENU screen appears. x 0 . 3968 y 0 . 4060 When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL UC00 T01 35. 93 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m I n t S t d N o n o n MENU MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [OPTION] and then press ENTER key. The MENU – OPTION screen appears. The current set contents are displayed in the [ND-FILTER] item. 45 MENU OPTION USER. CAL NON LENS STD ND-F I L T E R NON Setting When Using ND Filter Setting 3. Press either or key to select [ND-FILTER] and then press ENTER key. MENU OPTION N D- F I L T E R NONE The MENU - SETUP – ND-FILTER (ND filter selection) screen appears. 4. 5. Press either or key to select [NONE], [ND 10] or [ND 100]. ND 10 ND 100 MENU OPTION N D- F I L T E R NONE ND 10 ND 100 Press ENTER key. MENU OPTION When the ND filter is set, the MENU - OPTION screen appears again on the LCD. USER. CAL NON LENS STD By pressing ESC key, after the setting is canceled the MENU - OPTION screen appears again on the LCD. ND-F I L T E R 10 ND filter setting is saved even after switching OFF (O). 6. Press ESC key. The MENU screen appears again on the LCD. 7. Press ESC key. MEAS The MEAS screen appears again on the LCD. Lv SNGL UC00 T01 35. 93 x 0 . 3968 y 0 . 4060 Obs SPD SYNC L E N ND 2˚ Nr m I n t S t d 1 0 46 cd m2 BL on Calibration This instrument includes 11 calibration channels from Ch00 to Ch10. Ch00 is for measurement based upon KONICA MINOLTA’s calibration standard. Its calibration correction coefficient has been set and is unchangeable. The following contents can be set to Ch01 to Ch10 respectively using data management software CS-S10w Professional supplied with the CS-2000 as standard. See instruction manual of CS-S10w for details. Correction coefficient of user calibration Correction coefficient ID They are commonly used among each color space of Lvxy, Lvu’v’, LvT∆uv, XYZ, dominant wavelength/excitation purity and spectral graph in one channel. Calibration channels can be changed using the following procedure. Operation Procedure 6, 7 1 2, 3, 4, 5 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv UC00 T01 35. 93 x 0 . 3968 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND 2˚ Nr m N o n S t d 1 0 BL on MENU MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [OPTION] and then press ENTER key. The MENU – OPTION screen appears. The current set contents are displayed in the [USER.CAL] item. 47 MENU OPTION USER. CAL NON LENS STD ND-F I L T E R 10 Setting Calibration Channel 3. Press either or key to select [USER.CAL] and then press ENTER key. MENU OPTION USER. CAL CAL Setting The MENU - SETUP – USER.CAL (Calibration channel selection) screen appears. 4. The calibration channel number and compensation coefficient ID (with a maximum of 10 letters) are displayed. In case of Ch00, “NON” is displayed. See instruction manual of CS-S10w for details. Press either channel. or key to select the MENU OPTION USER. CAL CAL key for larger number. NO, 03 key for smaller number. 5. NO, NON The calibration channel numbers can be selected among NON, and 01 to 10. Press ENTER key. MENU OPTION When the calibration channel is set, the MENU OPTION screen appears again on the LCD. USER. CAL 03 LENS STD ND-F I L T E R If the calibration channel without compensation coefficient setting is selected, the setting will not be possible. 10 By pressing ESC key, after the setting is canceled the MENU - OPTION screen appears again on the LCD. 6. Press ESC key. The MENU screen appears again on the LCD. 7. Press ESC key. MEAS The MEAS screen appears again on the LCD. Lv SNGL UC03 T01 35. 93 x 0 . 3968 y 0 . 4060 Obs SPD SYNC L E N ND 2˚ Nr m N o n S t d 1 0 48 cd m2 BL on Backlight ON/OFF During Measurement The LCD backlight can be selectively turned on or off during measurement. If the backlight is turned off, LCD backlight reflection on the surrounding area affecting the measurement value during measurement can be avoided. If pressing the BACKLIGHT key to turn off the backlight, while the MEAS screen is displayed, the backlight is forcibly turned off independently of the following setting. Operation Procedure Setting * Factory default setting : ON 6, 7 1 2, 3, 4, 5 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv UC00 T01 35. 93 x 0 . 3968 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND 2˚ Nr m N o n S t d 1 0 BL on MENU MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [SETUP] and then press ENTER key. MENU SETUP OBSERVER 2° The MENU – SETUP screen appears. B A C K L I G H T @ MEAS ON The current set contents are displayed in the [BACKLIGHT@MEAS] item. DATA 49 FORM F Setting 3. Press either or key to select [BACKLIGHT@MEAS] and then press ENTER key. MENU SETUP BACKL I G H T @MEAS OFF ON The MENU - SETUP - BACKLIGHT@MEAS (Turning ON/OFF backlight during measurement) screen appears on the LCD. 4. 5. Press either or [ON] or [OFF]. key to select Press ENTER key. MENU SETUP When the setting is made to turn the backlight on or off during measurement, the MENU SETUP screen appears again on the LCD. OBSERVER 2° B A C K L I G H T @ MEAS OFF DATA FORM F By pressing ESC key, after the setting is canceled the MENU - SETUP screen appears again on the LCD. Setting of backlight ON/OFF during measurement is saved even after switching OFF (O). 6. Press ENTER key. The MENU screen appears again on the LCD. 7. Press ESC key. MEAS The MEAS screen appears again on the LCD. Lv SNGL UC00 T01 35. 93 x 0 . 3968 y 0 . 4060 Obs SPD SYNC L E N ND 2˚ Nr m N o n S t d 1 0 50 cd m2 BL off Measurement 51 Measurement Operation Procedure 5 6 1, 4 Measurement 2 3 1. Decide whether you use closeup lens (optional accessory) or not according to measuring object size and distance. See the table below for details on measuring distance and measuring area. If you set the closeup lens, lens type setting is required in this instrument. (See p.43) Measuring distance and measuring area Minimum measurement diameter ø (Measuring angle) Without closeup lens With closeup lens 2. 1° 0.2° 0.1° Maximum measurement diameter ø 1° 0.2° 0.1° (Unit: mm) Minimum measurement area Maximum measurement area Measuring area Measuring area when the measuring when the measuring distance is 500 mm ø distance is 1,000 mm ø 1° 1° 1° 0.2° 0.1° 5.00 1.00 0.50 350 1.00 0.20 0.10 1.39 0.28 0.14 55.0 0.2° 0.1° 0.2° 0.1° 1° 0.2° 0.1° 7.78 1.56 0.78 16.66 3.33 1.67 70.9 − − − − − − *Measurement distance is the distance from the front edge of the metal lens barrel or closeup lens ring. Rotate the measuring angle selector according to size of object and measurement distance, and set the aperture to 1°, 0.2°, or 0.1°. Do not operate the measuring angle selector during measurement. If measuring angle is switched during measurement, you may fail to perform measurement or to obtain correct measurement value. To rotate the measuring angle selector, move to a position where you can confirm the click. If you stop the selector in a halfway position, measurement may not be performed or wrong measurement values may be obtained. 52 1° 0.2° 0.1° 3. Rotate the diopter adjustment ring for adjustment of diopter. Make sure that aperture (black circle indicating measurement area) looks clear when observing object through finder. (See p.15) 4. Rotate the focus adjustment ring for objective lens for that purpose. 5. 6. When the MENU or MEMORY screen is displayed, press ESC key to switch to the MEAS screen. The MEAS (Measurement value) screen appears. Press the measurement button. When the measurement time is long, the measurement progress bar is displayed on the LCD until measurement is complete. If the measurement time is set to options other than [MANUAL], the measurement time will be determined after the approximate luminance is checked inside the measurement device. For this reason, it may take several seconds until the measurement time appears. The displayed time shows approximately how long it will take from the point of time display to the end of measurement. If the measurement time determined from the approximate luminance is short, the remaining time will not be displayed. Measurement Make sure that object around aperture looks clear when observing object through finder. Only measuring area for measuring object must be placed in aperture. If extra area, which is not measuring object, is included in aperture, you cannot perform correct measurement. MEAS SNGL Lv UC00 T01 36. 20 x 0 . 3968 y 0 . 4056 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f Display during measurement (Single measurement/when measurement time is long) MEAS SNGL UC00 T01 MEASURING 177s ESC : STOP Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f (Single measurement/when measurement time is short) MEAS Lv SNGL UC00 T01 36. 20 x 0 . 3968 y 0 . 4056 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f 53 When the measuring button is pressed and held for two or more seconds, continuous measurement is conducted. When the measurement time is long, the measurement progress bar appears with the latest measurement value. The displayed time shows the remaining time, same as for the single measurement. Measurement When the measurement time is short, the measurement progress bar does not appear, but the measurement value is sequentially updated and displayed. When ESC key is pressed during continuous measurement, measurement is stopped. In this case, the measurement that is ongoing when ESC key is pressed will be canceled, and the last obtained measurement value will be displayed. If ESC key is pressed in the middle of the first measurement, the measurement value will not be displayed. When ENTER key is pressed while the measurement value is displayed, the measurement properties are displayed so that the measurement conditions can be confirmed. When the measuring button or a random key is pressed, the MEAS screen appears again. 54 Display during measurementt (Continuous measurement/when measurement time is long) MEAS CONT UC00 T01 MEASURING 17s ESC Lv x y : STOP 13 . 17 0 . 3966 0 . 3905 cd 2 m Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f (Continuous measurement/when measurement time is short) MEAS Lv CONT UC00 T01 36. 20 x 0 . 3968 y 0 . 4056 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f PROPERTIES MEASURE ANGLE 1. 0 ˚ SPEED NORMAL SYNC NO SYNC LENS STANDARD FILTER NONE I N- N D OFF I NT G 6 6 . 6 6 7ms Saving the Measurement Value This instrument can save 100 measurement values with designated numbers from 00 to 99. Operation Procedure 2, 3 1. When the MEAS screen is displayed, press MEMORY key to switch to the MEMORY screen. The MEMORY (Memory data) screen appears. The memory data number oo is displayd. 2. 36 . 20 0 . 3968 0 . 4056 MEMORY Lv x y 00 34 . 22 0 . 3958 0 . 4060 cd cd 2 m 2 m Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f Press either or key to select the number of memory data. key for larger number. MEMORY MEAS Lv x y 36 . 20 0 . 3968 0 . 4056 MEMORY key for smaller number. 3. MEMORY MEAS Lv x y Lv x y 02 cd cd 2 m 2 m Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f Press ENTER key. MEMORY MEAS Each measurement value is saved with the selected number. If ESC key is pressed, saving is canceled and the MEAS screen appears on the LCD. Lv x y 36 . 20 0 . 3968 0 . 4056 MEMORY Lv x y 02 36 . 20 0 . 3968 0 . 4056 cd cd 2 m 2 m Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f 55 Measurement 1 Use the following procedure to display the memory data properties (measurement conditions): Operation Procedure 5, 6 1 Measurement 2, 3, 4 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv UC00 T01 35. 93 x 0 . 3968 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f MENU MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [MEMORY] and then press ENTER key. MENU MEMORY DELETE PROPERTIES The MENU – MEMORY screen appears. 3. Press either or key to select [PROPERTIES] and then press ENTER key. The MENU – MEMORY – PROPERTIES (Memory data measurement condition confirmation) screen appears. The memory data number 00 is displayed. 56 MENU MEMORY PROPERTIES MEMORY ANGLE SPEED SYNC LENS FILTER I N- N D I NT G 00 1. 0 ˚ NORMAL NO SYNC STANDARD NONE OFF 6 6 . 6 6 7ms 4. To display the memory data for another number, press either or key to change the memory data number. The properties of the selected memory data are displayed, and the measurement conditions can be confirmed. MENU MEMORY PROPERTIES MEMORY ANGLE SPEED SYNC LENS FILTER I N- N D I NT G 02 1. 0 ˚ NORMAL NO SYNC STANDARD NONE OFF 6 6 . 6 6 7ms key for larger number. If kept pressed, the value continuously changes. 5. Press ESC key. The MENU – MEMORY screen appears again on the LCD. 6. Press ESC key. The MEAS screen appears again on the LCD. 57 Measurement key for smaller number. If kept pressed, the value continuously changes. Deleting the Memory Data Stored measurement values can be deleted in the following procedure. Operation Procedure 5, 6, 7 1 Measurement 2, 3, 4, 5 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv UC00 T01 35. 93 x 0 . 3968 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f MENU MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [MEMORY] and then press ENTER key. MENU MEMORY DELETE PROPERTIES The MENU – MEMORY screen appears. 3. Press either or key to select [DELETE] and then press ENTER key. The MENU – MEMORY – DELETE (Memory data deletion) screen appears. The memory data number 00 is displayed. 58 MENU MEMORY MEM, D E L E T E MEM , DATA Lv x y NO , 0 0 34 . 22 0 . 3958 0 . 4060 4. Press either or key to select the number of memory data you want to delete. key for larger number. If kept pressed, the value continuously changes. [ALL] is displayed after No.99. MENU MEMORY MEM, D E L E T E MEM , DATA Lv x y NO , 0 2 36 . 20 0 . 3968 0 . 4056 key for smaller number. If kept pressed, the value continuously changes. [ALL] is displayed after No.00. 5-a-1. Deletion of saved data, one by one: Select the number of the memory data to be deleted, and press ENTER key. MENU MEMORY MEM, D E L E T E MEM , DATA NO , 0 2 Lv x y The saved measurement value disappears. By pressing ESC key, the deletion of the memory data is canceled and the MENU MEMORY screen appears again on the LCD. 5-a-2. 5-a-3. Repeat the steps 4 through 5-a-1. as necessary. Press ESC key. The MENU – MEMORY screen appears again on the LCD. 5-b-1. Collective deletion of all memory data: Select [ALL] and press ENTER key. The confirmation screen for deletion of all memory data is displayed. 59 MENU MEMORY MEM, D E L E T E MEM , DATA Lv x y NO , A L L 36 . 20 0 . 3968 0 . 4056 Measurement The deleted memory data can not be recovered. Confirm the number before deleting the memory data. 5-b-2. Press key to select [OK] and then press ENTER key. All memory data are deleted, and the MENU MEMORY screen appears again on the LCD. By selecting [CANCEL] and pressing ESC key, or pressing ENTER key, the deletion of all memory data is canceled and the MENU MEMORY screen appears again on the LCD. 6. Press ESC key. Measurement The MENU – MEMORY screen appears again on the LCD. 7. Press ESC key. The MEAS screen appears again on the LCD. 60 MENU MEMORY MEM, D E L E T E DELETE DELETE ALL DATA OK ? CANCEL Registering Target Color Target color The target color serves as reference for measurement of deviation of measured color from reference. Target colors can be registered up to 20 from Ch 01 to Ch 20 completely within this instrument. To register the target color: To change the previously set target color, select another target color. User calibration correction coefficient will not be influenced despite of target color change. The target color is commonly used among each color space of Lvxy, Lvu’v’, LvTΔuv, XYZ, dominant wavelength/excitation purity and spectral graph. Operation Procedure 10, 11 1 2, 3, 4, 5, 6, 7, 8, 9 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv 35. 93 x 0 . 3968 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f MENU MEAS MEMORY TARGET OPTION SETUP 61 UC00 T01 Measurement (1) Register the measurement value (2) Select from the memory data (3) Enter the numerical value 2. 3. Press either or key to select [TARGET] and then press ENTER key. MENU TARGET SELECT SET The MENU – TARGET screen appears. DELETE Press either or key to select [SET] and then press ENTER key. MENU TARGET TARGET SET TARGET Ch 01 The MENU – TARGET – SET screen appears. Measurement Lv x y 4. Change target color channels by pressing or key, and select the channel used to register a target color. key for larger number. If kept pressed, the number continuously increases. key for smaller number. If kept pressed, the number continuously decreases. Once a target color is registered, the status before registration cannot be restored. If the target colors are changed by overwriting, confirm the channel number before making the change. 5. Press ENTER key. The screen used for input of the target color ID appears on the LCD. MENU TARGET TARGET SET TARGET Ch 04 Lv x y 6. Enter the target color ID. When the key is pressed, the characters change among 0 to 9, a to z, A to Z, and space. key is pressed, the characters When the change among space, Z to A, z to a, and 9 to 0. key is pressed, the cursor moves to When the right by one position. key is pressed, the cursor moves to When the left by one position. 62 MENU TARGET TARGET SET TARGET Ch 04 sample Lv x y 7. 8. Press ENTER key. The screen used to select a target color appears on the LCD. By pressing ESC key, the input of the target color is canceled and the MENU - TARGET screen appears again on the LCD. MENU TARGET TARGET SET TARGET Ch 04 sample < SOURCE > MES Lv x y 36 . 20 0 . 3968 0 . 4056 Press either or key to select data to be a target color. When the key is pressed, values are changed among, M00 to M99, EDT, and MES. If kept pressed, the value continuously changes. 9-a-1. Selection of a measurement value as a target color: Select [MES] and press ENTER key. When the target color is registered, the MENU - TARGET screen appears again on the LCD. 9-b-1. Measurement key is pressed, values are When the changed among MES, EDT, and M00 to M99. If kept pressed, the value continuously changes. MENU TARGET TARGET SET TARGET Ch 04 sample < SOURCE > MES Lv x y 36 . 20 0 . 3968 0 . 4056 By pressing ESC key, the registration of the target color is canceled and the MENU TARGET screen appears again on the LCD. Selection of a memory data as a target color: Select from [M00~M99] and press ENTER key. When the target color is registered, the MENU - TARGET screen appears again on the LCD. MENU TARGET TARGET SET TARGET Ch 04 sample < SOURCE > M00 Lv x y 35 . 93 0 . 3968 0 . 4060 By pressing ESC key, the registration of the target color is canceled and the MENU TARGET screen appears again on the LCD. 9-c-1. Manual input of a target color: Select [EDT] and press ENTER key. MENU TARGET TARGET SET TARGET Ch 04 sample < SOURCE > EDT The screen used to input a target color with a numerical value appears on the LCD. Lv x y 63 0 . 0000E + 0 0 . 0000 0 . 0000 9-c-2. Enter the target color. key for larger number. If kept pressed, the value continuously increases. key for smaller number. If kept pressed, the value continuously becomes small. key is pressed, the cursor moves When to the right by one position. Measurement key is pressed, the cursor moves When to the left by one position. 9-c-3. Press ENTER key. When the target color is registered, the MENU - TARGET screen appears again on the LCD. When observer angle is 10°, Y is displayed instead of Lv and registered as Y10. If the entered value does not establish a proper combination with the value in the color space mode, the cursor will move to the first digit on the first line. Enter another value again. By pressing ESC key, the registration of the target color is canceled and the MENU TARGET screen appears again on the LCD. 10. Press ESC key. The MENU screen appears again on the LCD. 11. Press ESC key. The MEAS screen appears again on the LCD. 64 MENU TARGET TARGET SET TARGET Ch 04 sample < SOURCE > EDT Lv x y 0 . 6200E + 1 0 . 3968 0 . 4000 Selecting Target Color Select a target color for color-difference measurement from the channels Ch01 to Ch20. The new set color is also applied to the measurement value displayed on the current MEAS screen. Operation Procedure 6, 7 1 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv UC00 T01 36 . 20 x 0 . 3968 y 0 . 4056 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f MENU MEAS MEMORY TARGET OPTION SETUP 2. 3. Press either or key to select [TARGET] and then press ENTER key. MENU TARGET SELECT SET The MENU – TARGET screen appears. DELETE Press either or key to select [SELECT] and then press ENTER key. MENU TARGET TARGET S E L E C T TARGET Ch01 The MENU – TARGET – SELECT screen appears. Lv x y 65 Measurement 2, 3, 4, 5 4. Press either or key to switch the target color channel. MENU TARGET TARGET S E L E C T TARGET Ch04 sample key for larger number. If kept pressed, the number continuously increases. key for smaller number. If kept pressed, the number continuously decreases. 5. Lv x y 36 . 20 0 . 3968 0 . 4056 Press ENTER key. Measurement When the target color is set, the MENU TARGET screen appears again on the LCD. By pressing ESC key, the selection of the target color is canceled and the MENU TARGET screen appears again on the LCD. 6. Press ESC key. The MENU screen appears again on the LCD. 7. MEAS Press ESC key. The MEAS screen appears again on the LCD. Lv SNGL UC00 T04 36 . 20 x 0 . 3968 y 0 . 4056 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f 66 Deleting Target Color The registered target color can be deleted in the following procedure. Operation Procedure 6, 7 1 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL Lv UC00 T01 35. 93 x 0 . 3968 y 0 . 4060 cd m2 Obs SPD SYNC L E N ND BL 2˚ Nr m N o n S t d N o n o f f MENU MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [TARGET] and then press ENTER key. The MENU – TARGET screen appears. 3. Press either or key to select [DELETE] and then press ENTER key. The MENU – TARGET – DELETE (Target color deletion) screen appears. 67 MENU TARGET SELECT SET DELETE MENU TARGET TARGET D E L E T E TARGET Ch01 Lv x y Measurement 2, 3, 4, 5 4. Press either or key and select the number to delete the desirable memory data or [ALL]. Press ENTER key. Measurement key for larger number. If kept pressed, the value continuously changes. [ALL] is displayed after Ch 20. key for smaller number. If kept pressed, the value continuously changes. [ALL] is displayed after Ch 00. The confirmation screen to delete the target color appears. 5.-a-1. Deletion of target colors one by one: Press key to select [OK] and then press ENTER key. The display of the registered target color disappears. By selecting [CANCEL] and pressing ENTER key, or pressing ESC key, the deletion of the target color is canceled and the MENU - TARGET screen appears again on the LCD. 5.-a-2. To delete another target color continuously, repeat the steps 4 through 5-a-1. as necessary. 5.-a-3. Press ESC key. The MENU – TARGET screen appears again on the LCD. 68 MENU TARGET TARGET D E L E T E TARGET Ch04 sample Lv x y 36 . 20 0 . 3968 0 . 4056 MENU TARGET TARGET D E L E T E TARGET Ch 0 4 TARGET D E L E T E TARGET OK Ch , 04 CANCEL 5.-b-1. Collective deletion of all target colors: key to select [OK] and then press ENTER key. MENU TARGET TARGET D E L E T E TARGET Ch A L L TARGET D E L E T E TARGET OK Ch , ALL CANCEL By selecting [CANCEL] and pressing ENTER key, or pressing ESC key, the deletion of the target color is canceled and the MENU - TARGET screen appears again on the LCD. By pressing ESC key, the selection of the target color is canceled and the MENU TARGET screen appears again on the LCD. 6. Press ESC key. The MEAS screen appears again on the LCD. 7. Press ESC key. The MEAS screen appears again on the LCD. 69 Measurement When all target colors are deleted, the MENU - TARGET screen appears again on the LCD. 70 Communication 71 Connecting to PC This instrument can be used together with PC for mutual communication. Use the USB cable (2m) CS-A32 supplied as standard accessory for this purpose. The USB cable is allowed to plug/unplug while power is on, but it is recommended to switch power off in this case. Operation Procedure 1. 2. Switch power OFF (O). Connect the USB cable to the USB connector of this instrument. Make sure that USB cable is all seated to the USB connector. 3. Communication Communication interface in this instrument conforms to USB1.1. Hold the USB cable plug in unplugging. Do not pull the cord. Plug the USB cable to fit the connector entry point. To connect this instrument to PC, install the corresponding USB driver software. It is attached to the data management software CS-S10w Professional in the standard accessories. See installation guide of CS-S10w Professional for details on installing the USB driver software to PC. 72 Remote Mode Remote mode refers to sending command from PC to this instrument with both connected. If this instrument is controlled with PC, “REMOTE MODE” appears on the LCD. While this message is displayed, key operation of this instrument is not acceptable except for following cases. If the measurement button is pressed, measurement starts to forward the data to PC. (in case that measurement button is in valid mode by transferring command from PC to this instrument. Use data management software below.) When ESC key is pressed, the remote mode is canceled. To control this instrument with PC, use the data management software CS-S10w Professional in the standard accessories. See instruction manual of CS-S10w Professional for details on the specifications and usage. http://konicaminolta.com/instruments/download/software/index.html (The above URL is subject to change without notice.) (If the target page will not appear, please search the site by keywords, CS-2000 and download.) ESC Key Measurement button LCD screen 73 Communication If you want to use an independent program on PC to control this instrument, download Communication Specifications from KONICA MINOLTA’s website at URL below for your reference 74 Explanation 75 Measurement Principle Light energy passes through the objective lens. The lights from the measurement area pass through the hole in the center of the aperture mirror to the optical fiber, while the remaining light is guided to the finder optics by the aperture mirror. As a result, the part equivalent to the measurement area looks like a black circle when observed through the finder. The light entering the optic fiber is reflected repeatedly so that it is mixed and becomes virtually uniform. It then passes through the collimator lens to the plane diffraction grating. After being dispersed by the grating, the light is focused by the condenser lens according to wavelength. An array sensor is located at this focus point. The amount of detected energy for each wavelength is then converted to a digital value by an A/D converter, based on which the spectral radiant luminance and chromaticity are calculated by the processing section of the CS-2000. Sensor Section The sensor section has a photo diode array consisting of 512 elements. The array is always kept at constant temperature using a Peltier cooler, irrespective of the ambient temperature. This can reduce dark current and improve S/N ratio, thus enabling measurement of low luminance. Objective lens Array sensor Condenser lens Aperture mirror Collimator lens Shutter Optical fiber Explanation Plane diffraction grating Dark Measurement Each measurement consists of “light measurement” and “dark measurement”. “Light measurement” is performed with light from the object irradiating the sensor, while “dark measurement” is performed with no light from the object irradiating the sensor, so that detector dark current is measured. When measurement starts, first “light measurement” is performed. When “light measurement” is complete, the shutter will close automatically, then “dark measurement” starts immediately. “Dark measurement” is performed with the same integration time used for “light measurement”. The final measured data is obtained by subtracting the measured data obtained in “dark measurement” from the one obtained in “light measurement”. This method eliminates influences of dark current of the array sensor, resulting in improved measurement accuracy. 76 LvTΔuv Following factors can be acquired as measurement value with LvTΔuv as color space of this instrument. Lv : Luminance T :Correlated color temperature Δuv :Color difference from blackbody locus While Lvs stands for luminance, T and Δuv for color in LvTΔuv. <Relation between correlated color temperature T and color difference from blackbody locus Δuv> Color temperature refers to the temperature of black body (perfect radiator) which has equal chromaticity coordinates to certain light. However, color temperature only represents colors on blackbody locus. Correlated color temperature, slightly wider interpretation of color temperature, is very useful to eliminate such problem. Here, correlated color temperature covers those which are slightly outside the range of that of blackbody locus. If a certain color positions on isotemperature line, the intersection point of isotemperature line and blackbody locus is indicated as correlated color temperature for the color. Isotemperature line means line on chromaticity coordinates which is a set of colors visually close to color temperature on blackbody locus. However, since all colors on a color-matching temperature line are represented with equal correlated color temperature, it is not possible to describe color only with correlated color temperature. To solve that, Δuv, deviation of correlated color temperature T from blackbody locus, is to apply for that purpose. If Δuv exists above blackbody locus, it is represented with “+”, and below, with “-”. v Blackbody locus 0.35 2300K 0K 300 Δuv Explanation Correlated temperature T 00 50 K 0.30 130 00K 0.20 0.25 Correlated temperature T and Δuv 77 0.30 u Dominant wavelength/Excitation purity In the x, y chromaticity diagram shown below, the curve VScSR is the spectrum locus, and point N is the white point. Colors located in the region enclosed by the spectrum locus and the straight lines VN and NR are referred to as spectral colors; colors located in the triangle NVR with the white point N at the apex and the pure purple line VR as the base are referred to as nonspectral colors. <Dominant wavelength and excitation purity (spectral colors)> When the chromaticity point obtained by the measurement is C, the wavelength corresponding to the intersection point S of the extension of NC with the spectrum locus (curve VScSR) is referred to as the dominant wavelength and indicated by the symbol λd. The ratio of the lengths of the straight lines NC and NS is referred to as the excitation purity of color excitation C and indicated by the symbol pe. <Complementary wavelength (non-spectral colors)> When the chromaticity point obtained by measurement is C', the extension of NC' toward C' does not intersect with the spectrum locus but only the pure-purple lines. In this case the wavelength corresponding to the intersection point Sc of the extension of NC' toward N with the spectrum locus is referred to as the complementary wavelength and indicated by the symbol λc. When the intersection point of the extension of the line NC' with the line VR (pure-purple locus) is designated by S', the ratio of the lengths of NC' to NS' is referred to as excitation purity and indicated by the symbol p'v. The following equations are formulated, if each point is designated as the following coordinates: (xn, yn): chromaticity coordinate of point N; (xc, yc): chromaticity coordinate of point C; (x λ , yλ): chromaticity coordinate of point S, (xc', yc): chromaticity coordinate of point C', and (xp, yp): chromaticity coordinate of point: Explanation Excitation purity (spectral colors) xc – xn yc – yn pe = – = – x – xn y – yn y Spectrum locus Sc 0.8 Excitation purity (non-spectral colors) xc'– xn yc' – yn p e' = – = – 0.6 x p – xn y p – yn 550 nm S 500 nm C 0.4 600 nm White point R 780 nm 0.2 0 N C' S' Pure purple line V 380 nm 0.2 0.4 0.6 x Dominant wavelength on chromaticity diagram 78 Measurement of Object Color Use of the data management software CS-S10w Professional in the standard accessories enables simple measurement of the color of the object. Measured data is evaluated based on luminance which has been stored as light source data in CS-S10w. See instruction manual of CS-S10w for details. Set while calibration plate (optional accessory) and object on the same position with the same angle from this instrument. Uniform illumination and measurement conditions of white calibration plate and those of object. If not, measurement data may vary, causing incorrect data. Keep illumination light source as stable as possible with fixed voltage power source during measurement. Measurement Procedure Necessary Setting for Object Color Measurement 1. Set one or more tungsten lumps or equivalent as illumination source toward white calibration plate as in the right illustration. Set this instrument vertical to white calibration plate. 2. White Calibration Plate Illumination Light Source 45° Keep the angle between illumination light source and white calibration plate at 45°. Start up this instrument, PC, and software CS-S10w. 45° Illumination Light Source 3. 4. Set the document type to “object color” with CS-S10w. Conduct white calibration with CS-S10w. Measurement of Object 5. 6. Set object on the same position and at the same angle as white calibration plate. Conduct measurement with CS-S10w. See instruction manual of data management software CS-S10w for details. 79 Explanation White Calibration Dimensions 158 129 9 51 253 120.5 200 Filter screw diameter ø52 79 67.4 50 47 (Unit: mm) 300 58.5 392 Measurement Mounting screw M5 Mounting screw M5 distance reference Depth 6.5mm Depth 6.5mm 229.5 ø15 Positioning pin hole 1 ø5mm Depth 4 mm 70 170 90 6 Optical axis 5 Explanation 95.7 Positioning pin hole 2 Depth 4mm Tripod screw (3/8 inches screw) Depth 10.5 mm 190.4 80 Error Message Error message appears on the LCD when this instrument does not operate normally. Below table shows type of error message, its description and corrective action respectively. 1 2 3 4 MEMORY ERROR OVER SYNC ERROR Cause (Description) Corrective action Data stored in ROM is damaged. • Turn on the power switch again. • If the symptoms are not remedied, Luminance of measuring object is higher than the available range. • Use the ND filter and re-measure. • Decrease the measuring area and re-measure. • If the symptoms are not remedied, please contact the nearest KONICA MINOLTA authorized service facility. Flicker of measuring object is high. • Set the flicker cycle in INT SYNC mode, or input the flicker signal in EXT SYNC mode. Input signal in EXT SYNC mode is not at CMOS level. • Input a signal with 3.5 to 5.0 V at high level; 0.0 to 1.5 V at low level. Input signal in EXT SYNC mode exceeds 200 Hz. • Set the frequency value divided by an integer in INT SYNC mode and re-measure. Input signal in EXT SYNC mode is less than 20 Hz. • Set the integral multiple value of the input signal cycle in INT SYNC mode and re-measure using the MULTI INTEG-NORMAL mode or MULTI INTEG-FAST mode. • Set the integral multiple value of the input signal cycle in INT SYNC mode and remeasure using the MANUAL mode. please contact the nearest KONICA MINOLTA authorized service facility. Measurement was VIEWING-ANGLE SELECTOR ERROR performed when the • Switch the measuring angle selector and re-measure. Or, do not operate the measuring angle selector during measurement. • If the symptoms are not remedied, please contact the nearest KONICA MINOLTA authorized service facility. 5 TEMPERATURE ERROR The ambient temperature for the measurement device is too high, and an internal temperature of the sensor becomes abnormal. • Decrease the ambient temperature to enable cooling to within the specified temperature. 6 FAN ERROR The cooling fan stops, or the cooling device has an error. • Decrease the ambient temperature to enable cooling to within the specified temperature. • Turn off the power switch once, turn it on again after a while. • If the symptoms are not remedied, the fan must be repaired. Please contact the nearest KONICA MINOLTA authorized service facility. measuring angle selector was in the wrong position, or its position was changed during measurement. 81 Explanation Error Message Error Check Should any errors be found in this instrument, try the corrective actions shown in the following table. If this does not help, it’s possible the instrument is broken. Please contact the nearest KONICA MINOLTA authorized service facility with the error number and version of your instrument. To confirm the instrument version, see p.23. Error Symptom No. 1 No display on the LCD after power is turned on. Item to Check Corrective Action Has the AC adapter been properly Connect the AC adapter. plugged into the AC outlet? 21 Has the AC adapter been connected to this instrument? 21 Connect the AC adapter. Has a wrong AC adapter Be sure to use the AC adapter and been connected? power cord supplied as a standard or optional accessory (AC-A312). Is AC power source Use within ±10% of the nominal within rated scale? voltage. 2 Nothing is visible through the finder. Reference Page Is the lens cap still attached Remove the lens cap. to the objective lens? 21 21 8 Is the ND filter attached to the objective lens? 3 Explanation 4 5 6 7 Use the ND filter when the luminance of that being 9, 45 measured is too high. Is the ND eyepiece filter Use the ND eyepiece filter when attached to the finder? luminance of that being 9, 45 measured is too high. Nothing is displayed on Is the backlight set to Press BACKLIGHT key to turn 14, 49 the LCD. OFF? ON the backlight. Does not accept key operation. Has the backlight been set to OFF during measurement? Has the remote mode been set? In the menu operation, set the backlight to ON during measurement 49 Press ESC key to cancel the remote mode. 73 Have you pressed a Press the correct key. disabled key? Measurement unavailable Has a screen other than Conduct measurement when the even if the measurement MENU been displayed? MEAS screen is displayed. button is pressed. The entered value for A 1-digit difference may be target color is different found due to calculation error. from the one that will be displayed after setting. Measurement values Is there data? Conduct measurement. do not appear. Has the color space Color temperature is displayed mode become color as "_ _ _" if it is far from the temperature? blackbody locus. Change the display using the other color space mode and check. Did you interrupt Conduct measurement again. measurement? 82 — 53 61 52 39 52 Item to Check Is the measuring object stable? Is the measuring object of low luminance? Is the measurement sync frequency appropriate when measuring the display? 9 Measurement values appear incorrectly. Have the ambient temperature and /or humidity changed rapidly? Did you start measurement immediately after startup? Is the objective lens clean? User calibration may not be performed correctly. Is the calibration channel correct? Has the closeup lens been attached? Has the ND filter been attached? 10 Has the object been focused? Is the measuring object The measurement stops halfway and does of high luminance? not finish in the set measurement time. 83 Corrective Action Reference Page Conduct measurement with the — measuring object stable. Repeatability of x, y worsens if the measuring object of low luminance is measured. It especially worsens when the measurement angle is 0.2º or 52, 30 0.1º. It also worsens when the measurement time is short. Make the measurement time longer. Set the appropriate measurement sync frequency. Use MULTI INTEG-NORMAL 26, 30 mode or MULTI INTEG-FAST mode. Measure in EXT SYNC mode. Conduct measurement under an environment free from rapid 3 changes in ambient temperature and humidity. Allow the instrument to warm up for 20 minutes or more when the 23 power switch is turned on. Wipe off the lens with a dry, soft 52 cloth or lens cleaning paper. Check the values without user calibration (i.e. set the calibration 47 channel to 00 (NON) and check). Select the calibration channel according to the light source of 47 luminance and chroma close to the object. Select the lens type setting according to the attached 43, 52 closeup lens. Select the ND filter setting according to the attached ND 45 filter. Adjust the focus after adjusting 13, 15 the diopter. 52 When measuring an object of high luminance, the sensor may be saturated by exceeding the 45 upper limit of the current measurement setting. Use the ND filter. Explanation Error Symptom No. 8 Measurement values are inconsistent. Error Symptom No. 11 Actual measurement time is different from the displayed measurement time. 12 13 Measurement value on the LCD disappears. Item to Check The displayed measurement time is the remaining time. The actual measurement time may be different from the displayed time depending on the mode setting of measurement time. Has the power source Connect to a stable power been supplied securely? source and insert the AC adapter plug securely. Did you interrupt the When starting continuous measurement? measurement, press the measurement button securely. Do not press ESC key. Has the USB cable Connect this instrument and the been connected PC securely. securely? Has the USB cable Replace the USB cable. been disconnected? During USB communication: Cannot download data output from this instrument on the PC. Cannot enter commands or data from Has remote mode been the PC to this canceled? instrument. Has the program been prepared correctly? Same error message appears repeatedly. Check the appropriate corrective action for the error message. Explanation 14 Corrective Action 84 Send the connection command from the PC to this instrument and switch to remote mode. Use the data management software CS-S10w in the standard accessories. Refer to communication specifications and check the program. Use the data management software CS-S10w in the standard accessories. If the symptoms are not remedied, please contact the nearest KONICA MINOLTA authorized service facility. Reference Page 30 21 54 72 — 73 — — Setting Initialization Preset measurement conditions can be initialized to the factory default settings according to the following procedure. Factory default settings are shown below. * Synchronizing method : NO SYNC * Measurement time :M ULTI INTEG, 1s, IN-ND: AUTO * Observer : 2°OBS * Display format : ****.**** [F] * Color space mode : Lvxy * Absolute value (ABS)/ Difference (DIFF) display : Absolute value (ABS) * Lens type : STANDARD * ND filter type : NONE * Backlight during measurement : ON Operation Procedure 1, 2 1 When the power switch is OFF (O), turn it to ON ( I ) while pressing key and key MEMORY key, simultaneously. The INITIALIZE SETTINGS (confirmation of setting initialization) screen appears approx. 5 seconds after the initial screen on the LCD. key and Continue pressing MEMORY key, key until the INITIALIZE SETTINGS screen appears. 2. INITIALIZE RESET ALL SETTINGS ? OK CANCEL INITIALIZE Press key to select [OK] and then press ENTER key. The preset measurement conditions are initialized and the MEAS screen appears on the LCD. 85 SETTINGS SETTINGS RESET ALL SETTINGS ? OK CANCEL Explanation 1. Switching Luminance Unit You can select [cd/m2] or [ fL ] as the luminance unit. Operation Procedure 1 1, 2 1. When the power switch is OFF (O), turn it to ON ( I ) while pressing key MENU key and simultaneously. The Luminance Unit (switching luminance unit) screen appears approx. 5 seconds after the initial screen on the LCD. key until Continue pressing MENU key and the Luminance Unit screen appears. Explanation 2. Press either or key to select the luminance unit and then press ENTER key. The setting is entered and the MEAS screen appears on the LCD. 86 Luminance fL cd 2 m Unit Main Specifications Model CS-2000 Wavelength range 380 to 780 nm Wavelength resolution 0.9 nm/pixel Display wavelength bandwidth 1.0 nm Wavelength precision ±0.3 nm (median wavelength: 435.8 nm, 546.1 nm, 643.8 nm Hg-Cd lamp) Spectral bandwidth 5 nm or less (half bandwidth) Measuring angle (selectable) 1° 0.2° 0.1° Measurement luminance range (Standard light source A) 0.003 to 5,000 cd/m2 0.075 to 125,000 cd/m2 0.3 to 500,000 cd/m2 Minimum measuring area ø5 mm (ø1 mm when using closeup lens) ø1 mm ø0.2 mm when using closeup lens) ø0.5 mm ø0.1 mm when using closeup lens) Minimum measuring distance 350 mm (55 mm when using closeup lens) Minimum luminance display 0.00002 cd/m2 Minimum spectral radiance display 1.0×10-9 W/sr, m2, nm Accuracy: Luminance (Standard light source A)*1 ±2% Accuracy: Chromaticity (Standard light source A)*1 x,y x,y x y Repeatability: Luminance (2 σ ) 0.4% (0.003 to 0.05 cd/m2) 0.3% (0.05 to 0.1 cd/m2) 0.15% (0.1 to 5,000 cd/m2) 0.4% (0.075 to 1.25 cd/m2) 0.3% (1.25 to 2.5 cd/m2) 0.15% (2.5 to 125,000 cd/m2) 0.4% (0.3 to 5 cd/m2) 0.3% (5 to 10 cd/m2) 0.15% (10 to 500,000 cd/m2) Repeatability: Chromaticity (2 σ) 0.002 0.001 0.0006 0.0004 0.002 0.001 0.0006 0.0004 0.002 0.001 0.0006 0.0004 Polarization error 1°: 2% or less (400 to 780 nm); 0.1° and 0.2°: 3% or less (400 to 780 nm) Integration time Fast: 0.005 to 16 sec.; Normal: 0.005 to 120 sec. Measurement time 2 sec. min. (Manual mode) to 243 sec. max. (Normal mode) Color space mode Lv x y, Lvu'v', LvT ∆uv, XYZ, dominant wavelength, spectral graph Interface USB 1.1 Operating temperature/ humidity range 5 to 35°C, relative humidity 80% or less with no condensation Storage temperature/ humidity range 0 to 35°C, relative humidity 80% or less with no condensation Size Main unit: 158 (W) × 200 (H) x 300 (D) mm; Lens: ø70 x 95 mm Weight 6.2 kg (0.003 to 0.005 cd/m2) (0.005 to 0.1 cd/m2) (0.1 to 0.2 cd/m2) (0.2 to 5,000 cd/m2) x,y x,y x y : ±0.003 (0.075 to 0.125 cd/m2) : ±0.002 (0.125 to 1.25 cd/m2) : ±0.0015(1.25 cd/m2 or more) : ±0.001 (0.075 to 0.125 cd/m2) (0.125 to 2.5 cd/m2) (2.5 to 5 cd/m2) (5 to 125,000 cd/m2) x,y x,y x y : ±0.003 (0.3 to 0.5 cd/m2) : ±0.002 (0.5 to 5 cd/m2) : ±0.0015(5 cd/m2 or more) : ±0.001 (0.3 to 0.5 cd/m2) (0.5 to 10 cd/m2) (10 to 20 cd/m2) (20 to 500,000 cd/m2) *1: Average of 10 measurements in Normal mode at a temperature of 23±2°C and a relative humidity of 65% or less. 87 Explanation : ±0.003 (0.003 to 0.005 cd/m2) : ±0.002 (0.005 to 0.05 cd/m2) : ±0.0015 (0.05 cd/m2 or more) : ±0.001 Model CS-2000A Wavelength range 380 to 780 nm Wavelength resolution 0.9 nm/pixel Display wavelength bandwidth Wavelength precision 1.0 nm ±0.3 nm (median wavelength: 435.8 nm, 546.1 nm, 643.8 nm Hg-Cd lamp) Spectral bandwidth 5 nm or less (half bandwidth) Measuring angle (selectable) 1° 0.2° 0.1° Measurement luminance range (Standard light source A) 0.0005 to 5,000 cd/m2 0.0125 to 125,000 cd/m2 0.05 to 500,000 cd/m2 Minimum measuring area ø5 mm (ø1 mm when using closeup lens) ø1 mm ø0.2 mm when using closeup lens) ø0.5 mm ø0.1 mm when using closeup lens) Minimum measuring distance 350 mm (55 mm when using closeup lens) Minimum luminance display 0.00002 cd/m2 Minimum spectral radiance display 1.0×10-9 W/sr, m2, nm Accuracy: Luminance (Standard light source A)*1 ±2% Accuracy: Chromaticity (Standard light source A)*1 x,y : ± 0.002 (0.001 to 0.05 cd/m2) x : ± 0.0015 (0.05 cd/m2 or more) y : ± 0.001 (0.05 cd/m2 or more) x,y : ± 0.002 (0.025 to 1.25 cd/m2) x : ± 0.0015 (1.25 cd/m2 or more) y : ± 0.001 (1.25 cd/m2 or more) x,y : ± 0.002 (0.1 to 5 cd/m2) x : ± 0.0015 (5 cd/m2 or more) y : ± 0.001 (5 cd/m2 or more) Repeatability: Luminance (2 σ ) 1.5 % 0.7 % 0.25 % 0.15 % 1.5 % 0.7 % 0.25 % 0.15 % 1.5 % 0.7 % 0.25 % 0.15 % Repeatability: Chromaticity (2 σ) x : 0.003 y : 0.0035 (0.001 to 0.003 cd/m2) x : 0.001 y : 0.0015 (0.003 to 0.1 cd/m2) x, y : 0.0006 (0.1 to 0.2 cd/m2) x, y : 0.0004 (0.2 to 5,000 cd/m2) Polarization error 1°: 2% or less (400 to 780 nm); 0.1° and 0.2°: 3% or less (400 to 780 nm) Integration time Fast: 0.005 to 16 sec.; Normal: 0.005 to 120 sec. Measurement time Approx. 247 sec. max. Color space mode Lv x y, Lvu'v', LvT∆uv, XYZ, dominant wavelength, spectral graph Interface USB 1.1 Operating temperature/ humidity range 5 to 30°C, relative humidity 80% or less with no condensation Storage temperature/ humidity range 0 to 35°C, relative humidity 80% or less with no condensation Size Main unit: 158 (W) × 200 (H) x 300 (D) mm; Lens: ø70 x 95 mm Weight 6.2 kg (0.0005 to 0.001 cd/m2) (0.001 to 0.003 cd/m2) (0.003 to 0.05 cd/m2 (0.05 to 5,000 cd/m2) (0.0125 to 0.025 cd/m2) (0.025 to 0.075 cd/m2 (0.075 to 1.25 cd/m2) (1.25 to 125,000 cd/m2) x : 0.003 y : 0.0035 (0.025 to 0.075 cd/m2) x : 0.001 y : 0.0015 (0.075 to 2.5 cd/m2) x, y : 0.0006 (2.5 to 5 cd/m2) x, y : 0.0004 (5 to 125,000 cd/m2) (0.05 to 0.1 cd/m2) (0.1 to 0.3 cd/m2) (0.3 to 5 cd/m2 (5 to 500,000 cd/m2) x : 0.003 y : 0.0035 (0.1 to 0.3 cd/m2) x : 0.001 y : 0.0015 (0.3 to 10 cd/m2) x, y : 0.0006 (10 to 20 cd/m2) x, y : 0.0004 (20 to 500,000 cd/m2) *1: Average of 10 measurements in Normal mode at a temperature of 23±2°C and a relative humidity of 65% or less. 88 9222-A0E3-13 ©2007-2012 KONICA MINOLTA OPTICS, INC. BCEEEE Printed in Japan
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project