Model: MV-PI300A Installation and User Guide For use in vehicles with 12V negative ground electrical systems only. Use of the MV-PI300A with a non 12V negative ground electrical system can result in failure of the unit and or a blown fuse. Specifications • • • • • • • • Safety Features Input Voltage Range: . . . . . . . . . . . . . . . . . . . . . 10-15V DC Input Full Load Current: . . . . . . . . . . . . . . . . . . . . . . . . 30A Standby Input Current: . . . . . . . . . . . . . . . . . . . . . . . <0.32A Output Voltage (AC): . . . . . . . . . . . . . . . . . . . . . 110V ± 5% Continuous Output Power: . . . . . . . . . . . . . . . . . . . . . 300W Dimension . . . . . . . . . . . (L) 155mm (W) 73mm (H) 73mm Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2lbs.(900g) Replacement Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35A • • • • Auto Operating Fan Overload Protection Output Short Circuit Protection Reverse Polarity Battery Protection Trouble Shooting When the Power Inverter Does Not Appear to be Functioning Properly, Check the Following Trouble Shooting Procedures. (b) Disconnect some of the appliances. (c) Check the power consumption of your AC appliance, make sure it is below 300W. 1) Poor Contact: clean contact parts thoroughly. 2) Receptacle Has No Power Output: (a) Check fuse, replace damaged fuse with same amperage. (b) Check receptacle wiring, repair if necessary. 3) Output Short, Heat Overload: Under heavy loads, the AC output will decrease. This is to protect the Unit from overheating, (a) turn off the unit until it cools down • • • • Warning Signals Low Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . BI BI BI Over Heating . . . . . . . . . . . . . . . . . . . . . . . . . . BI BI BI BI Over Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . BI BI BI BI BI Output Short . . . . . . . . . . . . . . . . . . . . . . . . BIBIBIBIBIBIBI Connection Mounting Caution! DO NOT reverse power input connection, it can cause severe damage to the power unit. Acceptable mounting positions Note: be sure to leave at least 1" around the unit for proper ventilation. Under-Counter Mount (-)GROUND (+)12V WARNING! Do Not Reverse Polarity Red Wire: Connect to Switched +12V Black Wire: Connect to Ground 1111 West Victoria Street Compton, CA 90220 Floor Mount MV-PI300AINS Rev. A 6-21-02 © 2002 Copyright Magnadyne Corporation
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement