Magnadyne Car Stereo System MV-PI300A User manual

Magnadyne Car Stereo System MV-PI300A User manual
Model: MV-PI300A
Installation and User Guide
For use in vehicles with 12V negative ground electrical systems only. Use of the MV-PI300A with a non 12V negative ground
electrical system can result in failure of the unit and or a blown fuse.
Specifications
•
•
•
•
•
•
•
•
Safety Features
Input Voltage Range: . . . . . . . . . . . . . . . . . . . . . 10-15V DC
Input Full Load Current: . . . . . . . . . . . . . . . . . . . . . . . . 30A
Standby Input Current: . . . . . . . . . . . . . . . . . . . . . . . <0.32A
Output Voltage (AC): . . . . . . . . . . . . . . . . . . . . . 110V ± 5%
Continuous Output Power: . . . . . . . . . . . . . . . . . . . . . 300W
Dimension . . . . . . . . . . . (L) 155mm (W) 73mm (H) 73mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2lbs.(900g)
Replacement Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35A
•
•
•
•
Auto Operating Fan
Overload Protection
Output Short Circuit Protection
Reverse Polarity Battery Protection
Trouble Shooting
When the Power Inverter Does Not Appear to be Functioning Properly, Check the Following Trouble Shooting Procedures.
(b) Disconnect some of the appliances. (c) Check the
power consumption of your AC appliance, make sure it is
below 300W.
1) Poor Contact: clean contact parts thoroughly.
2) Receptacle Has No Power Output: (a) Check fuse, replace
damaged fuse with same amperage. (b) Check receptacle
wiring, repair if necessary.
3) Output Short, Heat Overload: Under heavy loads, the AC
output will decrease. This is to protect the Unit from
overheating, (a) turn off the unit until it cools down
•
•
•
•
Warning Signals
Low Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . BI BI BI
Over Heating . . . . . . . . . . . . . . . . . . . . . . . . . . BI BI BI BI
Over Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . BI BI BI BI BI
Output Short . . . . . . . . . . . . . . . . . . . . . . . . BIBIBIBIBIBIBI
Connection
Mounting
Caution! DO NOT reverse power input connection, it can
cause severe damage to the power unit.
Acceptable mounting positions
Note: be sure to leave at least 1" around the unit for proper
ventilation.
Under-Counter
Mount
(-)GROUND
(+)12V
WARNING! Do Not Reverse Polarity
Red Wire: Connect to
Switched +12V
Black Wire: Connect
to Ground
1111 West Victoria Street
Compton, CA 90220
Floor Mount
MV-PI300AINS
Rev. A 6-21-02
© 2002 Copyright Magnadyne Corporation