Samsung | AR24MQFRBWKNFA | User manual | Samsung AR3000M Wall-mount AC with Fast Cooling, 24,000 BTU/h User manual

Samsung AR3000M Wall-mount AC with Fast Cooling, 24,000 BTU/h User manual
Air conditioner
User manual/Installation manual
ARMRFQ
•• Thank you for purchasing this Samsung air conditioner.
•• Before operating this unit, please read this user manual carefully and retain it for future reference.
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 1
2017-01-20 오전 11:28:24
Contents
Safety Information
5
Safety Information
5
At a Glance
13
Indoor Unit Overview
13
Remote Control Overview
14
Inserting batteries
Remote Control Operation
15
Operation modes
Controlling temperature
Controlling fan speed
Controlling air flow direction
Power Smart Features
17
Cooling Operation
17
Cool mode
Dehumidifying Operation
17
Dry mode
Quick Smart Features
18
Auto mode
Fan mode
Turbo function
Display lighting function
Energy-Saving Features
20
Energy-Saving Operation
20
Timed on/Timed off function
good’sleep function
Cleaning and Maintenance
22
Cleaning at a Glance
22
Troubleshooting
24
2 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 2
2017-01-20 오전 11:28:25
Installation
28
Safety Information on Installation
28
Preparation
30
Step 1.1 Choosing the installation location
Step 1.2 Checking and preparing accessories and tools
Step 1.3 Drilling a hole through the wall
Step 1.4 Taping the pipes, cables, and drain hose
Indoor Unit Installation
34
Step 2.1 Connecting the cables (assembly cable)
Step 2.2 Optional: Extending the power cable
Step 2.3 Installing and connecting the drain hose
Step 2.4 Optional: Extending the drain hose
Step 2.5 Optional: Changing the direction of the drain hose
Step 2.6 Installing and connecting the assembly pipes to the refrigerant pipes (assembly pipe)
Step 2.7 Shortening or extending the refrigerant pipes (assembly pipe)
Step 2.8 Fixing the installation plate
Outdoor Unit Installation
40
Step 3.1 Fixing the outdoor unit in place
Step 3.2 Connecting the cables and the refrigerant pipes
Step 3.3 Evacuating the air
Step 3.4 Adding refrigerant
Installation Inspection
43
Step 4.1 Performing the gas leak tests
Step 4.2 Performing final check and trial operation
English 3
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 3
2017-01-20 오전 11:28:25
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.
charger, headset, USB cable) should not be disposed of with other household waste at the end of their working
life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please
separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of
material resources.
Household users should contact either the retailer where they purchased this product, or their local government
office, for details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This
product and its electronic accessories should not be mixed with other commercial wastes for disposal.
Correct disposal of batteries in this product
This marking on the battery, manual or packaging indicates that the batteries in this product should not be
disposed of with other household waste at the end of their working life. Where marked, the chemical symbols Hg,
Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive
2006/66.
4 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 4
2017-01-20 오전 11:28:25
Safety Information
Safety Information
Safety Information
Before using your new air conditioner, please read this manual
thoroughly to ensure that you know how to safely and efficiently
operate the extensive features and functions of your new appliance.
Because the following operating instructions cover various models,
the characteristics of your air conditioner may differ slightly from
those described in this manual. If you have any questions, call your
nearest contact centre or find help and information online at www.
samsung.com.
WARNING
Hazards or unsafe practices that may result in severe personal
injury or death.
CAUTION
Hazards or unsafe practices that may result in minor personal
injury or property damage.
Follow directions.
Do NOT attempt.
M
ake sure the machine is grounded to prevent electric shock.
Cut off the power supply.
Do NOT disassemble.
FOR INSTALLATION
WARNING
Use a power cord with this product's power specifications
or higher and use the power cord for this appliance only. In
addition, do not use an extension cord.
• Extending the power cord may result in electric shock or fire.
• Do not use an electric transformer. This may result in electric
shock or fire.
English 5
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 5
2017-01-20 오전 11:28:25
Safety Information
Safety Information
• If the voltage/frequency/rated current condition is different,
it may cause fire.
The installation of this appliance must be performed by a
qualified technician or service company.
• Failing to do so may result in electric shock, fire, explosion,
problems with the product, or injury and may also void
warranty on the installed product.
Install an Isolation Switch next to the Air Conditioner (but
not on the panels of the Air Conditioner) and circuit breaker
dedicated to the air conditioner.
• Failing to do so may result in electric shock or fire.
Fix the outdoor unit firmly so that the electric part of the
outdoor unit is not exposed.
• Failing to do so may result in electric shock, fire, explosion,
or problems with the product.
Do not install this appliance near a heater, or inflammable material.
Do not install this appliance in a humid, oily or dusty location, in
a location exposed to direct sunlight and water (or rain). Do not
install this appliance in a location where gas may leak.
• This may result in electric shock or fire.
Never install the outdoor unit in a location such as on a high
external wall where it could fall.
• If the outdoor unit falls, it may result in injury, death or
property damage.
This appliance must be properly grounded. Do not ground the
appliance to a gas pipe, plastic water pipe, or telephone line.
• Failing to do so may result in electric shock, fire, and
explosion.
• Make sure to use a socket-outlet with ground.
6 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 6
2017-01-20 오전 11:28:25
Please cover the air conditioner with PE BAG after installation,
and remove it when you start to run air conditioner.
Install your appliance on a level and hard floor that can
support its weight.
• Failing to do so may result in abnormal vibrations, noise, or
problems with the product.
Safety Information
CAUTION
Install the drain hose properly so that water drains correctly.
• Failing to do so may result in water overflowing and
property damage. Avoid adding drain to waste pipes as
odours may arise in the future.
When installing the outdoor unit, make sure to connect the
drain hose so that draining is performed correctly.
• The water generated during heating by the outdoor unit may
overflow and result in property damage.
In particular, in winter, if a block of ice falls, it may result in
injury, death or property damage.
FOR POWER SUPPLY
WARNING
When the circuit breaker is damaged, contact your nearest
service centre.
Do not pull or excessively bend the power line. Do not twist
or tie the power line. Do not hook the power line over a metal
object, place a heavy object on the power line, insert the
power line between objects, or push the power line into the
space behind the appliance.
• This may result in electric shock or fire.
English 7
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 7
2017-01-20 오전 11:28:25
Safety Information
Safety Information
CAUTION
When not using the air conditioner for a long period of time or
during a thunder/lightning storm, cut the power at the circuit
breaker.
• Failing to do so may result in electric shock or fire.
FOR USING
WARNING
If the appliance is flooded, please contact your nearest service
centre.
• Failing to do so may result in electric shock or fire.
If the appliance generates a strange noise, a burning smell or
smoke, cut off the power supply immediately and contact the
nearest service centre.
• Failing to do so may result in electric shock or fire.
In the event of a gas leak (such as propane gas, LP gas, etc.),
ventilate immediately without touching the power line. Do not
touch the appliance or power line.
• Do not use a ventilating fan.
• A spark may result in an explosion or fire.
To reinstall the air conditioner, please contact your nearest
service centre.
• Failing to do so may result in problems with the product,
water leakage, electric shock, or fire.
• Delivery service for the product is not provided. If you
reinstall the product in another location, additional
construction expenses and an installation fee will be charged.
8 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 8
2017-01-20 오전 11:28:26
Do not touch the circuit breaker with wet hands.
• This may result in electric shock.
Safety Information
• Especially, when you wish to install the product in an
unusual location such as in an industrial area or near the
seaside where it is exposed to salt in the air, please contact
your nearest service centre.
Do not turn the air conditioner off with the circuit breaker
while it is operating.
• Turning the air conditioner off and then on again with the
circuit breaker may cause a spark and result in electric shock
or fire.
After unpacking the air conditioner, keep all packaging
materials well out of the reach of children, as packaging
materials can be dangerous to children.
• If a child places a bag over its head, it may result in
suffocation.
Do not touch the air flow blade with your hands or fingers
during heating.
• This may result in electric shock or burns.
Do not insert your fingers or foreign substances into the air
inlet/outlet of the air conditioner.
• Take special care that children do not injure themselves by
inserting their fingers into the product.
Do not strike or pull the air conditioner with excessive force.
• This may result in fire, injury, or problems with the product.
Do not place an object near the outdoor unit that allows
children to climb onto the machine.
• This may result in children seriously injuring themselves.
English 9
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 9
2017-01-20 오전 11:28:26
Safety Information
Safety Information
Do not use this air conditioner for long periods of time in badly
ventilated locations or near infirm people.
• Since this may be dangerous due to a lack of oxygen, open a
window at least once an hour.
If any foreign substance such as water has entered the
appliance, cut off the power supply and contact the nearest
service centre.
• Failing to do so may result in electric shock or fire.
Do not attempt to repair, disassemble, or modify the appliance
yourself.
• Do not use any fuse (such as cooper, steel wire, etc.) other
than the standard fuse.
• Failing to do so may result in electric shock, fire, problems
with the product, or injury.
CAUTION
Do not place objects or devices under the indoor unit.
• Water dripping from the indoor unit may result in fire or
property damage.
Check that the installation frame of the outdoor unit is not
broken at least once a year.
• Failing to do so may result in injury, death or property
damage.
Max current is measured according to IEC standard for safety
and current is measured according to ISO standard for energy
efficiency.
Do not stand on top of the appliance or place objects (such as
laundry, lighted candles, lighted cigarettes, dishes, chemicals,
metal objects, etc.) on the appliance.
10 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 10
2017-01-20 오전 11:28:26
Do not operate the appliance with wet hands.
• This may result in electric shock.
Do not spray volatile material such as insecticide onto the
surface of the appliance.
• As well as being harmful to humans, it may also result in
electric shock, fire or problems with the product.
Safety Information
• This may result in electric shock, fire, problems with the
product, or injury.
Do not drink the water from the air conditioner.
• The water may be harmful to humans.
Do not apply a strong impact to the remote control and do not
disassemble the remote control.
Do not touch the pipes connected with the product.
• This may result in burns or injury.
Do not use this air conditioner to preserve precision
equipment, food, animals, plants or cosmetics, or for any other
unusual purposes.
• This may result in property damage.
Avoid directly exposing humans, animals or plants to the air
flow from the air conditioner for long periods of time.
• This may result in harm to humans, animals or plants.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, without supervision
or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
English 11
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 11
2017-01-20 오전 11:28:26
Safety Information
Safety Information
FOR CLEANING
WARNING
Do not clean the appliance by spraying water directly onto it.
Do not use benzene, thinner or alcohol to clean the appliance.
• This may result in discolouration, deformation, damage,
electric shock or fire.
Before cleaning or performing maintenance, cut off the power
supply and wait until the fan stops.
• Failing to do so may result in electric shock or fire.
CAUTION
Take care when cleaning the surface of the heat exchanger of
the outdoor unit since it has sharp edges.
• This should be done by a qualified technician. Please contact
your installer or service centre.
Do not clean the inside of the air conditioner by yourself.
• For cleaning inside the appliance, contact your nearest
service centre.
• When cleaning the filter, refer to the descriptions in the
‘Cleaning at a Glance’ section.
• Failing to do so may result in damage, electric shock or fire.
12 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 12
2017-01-20 오전 11:28:26
At a Glance
Indoor Unit Overview
The actual product may differ slightly from the image depicted below.
At a Glance
01 Air intake
04 Air flow blade (left and right)
02 Air filter
05 Display
03 Air flow blade (up and down)
06 Room temperature sensor
07 Remote control receiver
English 13
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 13
2017-01-20 오전 11:28:28
Remote Control Overview
01 Operation mode indicator
02 Set temperature indicator/Timer option
indicator
Heat
03 good'sleep indicator
04 Options indicator
05 Transmit indicator
06 Low battery indicator
At a Glance
07 Fan speed indicator
08 Settings indicator
09 Power button
10 Temperature button
11 Options button
12 Timer button
13 Direction button / Selection button
14 Vertical air swing button
15 Mode button
16 Fan speed button
17 Direct button
18 Settings button
19 SET button
NOTE
Inserting batteries
• The descriptions in this manual are primarily
made based on the remote control buttons.
• Although Heat / Clean are displayed on
the remote control display. they are not
available on this model.
two 1.5V AAA type batteries
14 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 14
2017-01-20 오전 11:28:29
Remote Control Operation
You can use the air conditioner easily by selecting a mode and then by controlling the
temperature, fan speed, and air direction.
Operation modes
You can change the current mode between Auto, Cool, Dry and
Fan by pressing the
button.
Controlling temperature
Mode
Temperature control
Auto/Cool
Adjust by 1 °C between 17 °C and 30 °C.
Dry
Adjust by 1 °C between 17 °C and 30 °C.
Fan
You cannot control the temperature.
At a Glance
You can control the temperature in each mode as follows:
NOTE
You can use the Cool and Dry modes in the following
conditions:
Mode
Cool
Dry
Indoor temperature
17 °C to 32 °C
10 °C to 32 °C
Outdoor temperature
18 °C to 43 °C
11 °C to 43 °C
Indoor humidity
80% or less
relative humidity
_
• If the air conditioner operates in a high humidity
environment in the Cool mode for an extended period of
time, condensation may occur.
English 15
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 15
2017-01-20 오전 11:28:29
Remote control Operation
Controlling fan speed
You can select the following fan speeds in each mode:
Mode
Available fan speeds
Auto/Dry
(Auto)
Cool/Fan
(Auto),
(Low),
(Med),
(High)
At a Glance
Controlling air flow direction
Keep the vertical air flow in a constant direction by stopping
the movements of the vertical air flow blade.
In operation ►
NOTE
• If you adjust the vertical air blade manually. It may not
close completely when you turn off the air conditioner.
Horizontal air flow (manual)
Keep the horizontal air flow in a constant direction by
changing the directions of the horizontal air flow blades
manually.
Deflector rod
CAUTION
• To prevent personal injury, make sure
that you change the directions of the
horizontal air flow blades after stopping
the movements of the vertical air flow
blade.
16 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 16
2017-01-20 오전 11:28:30
Power Smart Features
Cooling Operation
The smart and powerful cooling functions of the Samsung air conditioner keep an enclosed space
cool and comfortable.
Cool mode
Use the Cool mode to stay cool in hot weather.
►
► Select Cool.
NOTE
• For comfort, keep the temperature difference between the
indoor and outdoor air within 5 °C in the Cool mode.
• After selecting the Cool mode, select a function,
temperature, and fan speed that you want to apply.
Dehumidifying Operation
The dehumidifying function of the Samsung air conditioner keeps an enclosed space dry and
comfortable.
Power Smart Features
–– To cool your room quickly, select a low temperature and
a strong fan speed.
–– To save energy, select a high temperature and a weak
fan speed.
Dry mode
Use the Dry mode in rainy or humid weather.
►
► Select Dry.
NOTE
• The lower the set temperature is, the greater the
dehumidifying capacity is. When the current humidity
seems to be high, adjust the set temperature to a low
temperature.
• You cannot use the Dry mode for heating. The Dry mode is
designed to produce a cooling side-effect.
English 17
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 17
2017-01-20 오전 11:28:30
Quick Smart Features
There is a variety of extra functionality provided by the Samsung air conditioner.
Auto mode
Use the Auto mode when you want the air conditioner to
automatically control the operation. The air conditioner will
provide the most comfortable atmosphere that it can.
►
► Select Auto.
NOTE
• When the indoor temperature seems to be higher or
lower than the set point, the air conditioner automatically
produces cool air to cool down the indoor temperature.
Power Smart Features
Fan mode
Use the Fan mode to run the air conditioner like a common
fan. The air conditioner provides a natural breeze.
►
► Select Fan.
NOTE
• If the air conditioner will not be used for an extended
period of time, dry the air conditioner by running it in the
Fan mode for 3 or 4 hours.
• The outdoor unit is designed not to operate in the Fan
mode to prevent cold air from entering through the unit.
This is a normal operation and not a fault with the air
conditioner.
18 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 18
2017-01-20 오전 11:28:31
Turbo function
Use the Turbo function to quickly cool your room. This
function is the most powerful cooling function provided by
the air conditioner. You can select this function in the Cool
modes.
In the Cool mode ►
►
►
Select Turbo. ►
NOTE
• You can change the air flow direction.
• You can change the set temperature and the fan speed.
Display lighting function
Use the Display lighting function to turn on or off the lighting
of the indoor unit display.
►
Power Smart Features
• If you select the Turbo function while such functions as
good'sleep is running these functions are cancelled.
► Select Display. ►
NOTE
• The Display lighting function does not operate when the
indoor unit is turned off.
• If you change the current mode or funtion when the
Display lighting function is on, the Display lighting
function turns on.
English 19
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 19
2017-01-20 오전 11:28:31
Energy-Saving Features
Energy-Saving Operation
Timed on/Timed off function
Use the Timed on/Timed off to turn on or off the air
conditioner after the time that you set.
(Select On or Off among On, Off, and
.) ►
(Set the on/off time.) ►
• Press the
(Timer) button to change the current
function between On, Off, and
(good’sleep).
NOTE
• You can set a time between 0.5 and 24 hours. Set the time
interval to 0.0 to cancel the Timed on/off function.
• After starting the Timed on function, you can change the
mode and the set temperature. You cannot change the set
temperature while the Fan mode is running.
Energy-Saving Features
• You cannot set the same time for both of the Timed on
and Timed off functions.
Combining Timed on and Timed off
When
the air
conditioner
is off
Example) Timed on: 3 hours, Timed off: 5 hours
The air conditioner turns on after 3 hours from
the moment you start Timed on/off, remains
on for 2 hours, then turns off automatically.
Example) Timed on: 3 hours, Timed off: 1 hour
When
The air conditioner turns off after 1 hour from
the air
the moment you start Timed on/off, then turns
conditioner
on after 2 hours from the moment it is turned
is on
off.
20 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 20
2017-01-20 오전 11:28:32
good’sleep function
Use the good'sleep function to get a good sleep at night and
to save energy. You can select this function in the Cool mode.
In the Cool mode
►
(Select
among ►
On, Off, and
.)
(Set the
►
operation time.)
• Press the
(Timer) button to change the current
function between On, Off, and
(good’sleep).
NOTE
• You can adjust the set temperature by 1 °C between 17 °C
and 30 °C.
• The recommended and optimal set temperatures in the
good’sleep function are as follows:
Recommended set
temperature
Optimal set
temperature
Cool
25 °C to 27 °C
26 °C
• You can set the operation time to between 0.5 and
24 hours. Set the operation time to 0.0 to cancel the
good'sleep function.
• The default operation time for the good'sleep function
in the Cool mode is 7 hours. The air conditioner stops
automatically when the operation time expires.
Energy-Saving Features
Mode
• When the Timed on, Timed off, and good'sleep functions
are overlapped, the air conditioner operates its timer with
only the function that you have started most recently.
English 21
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 21
2017-01-20 오전 11:28:32
Cleaning and Maintenance
Cleaning at a Glance
Cleaning the indoor unit exterior and outdoor unit heat exterior
Tepid damp cloth
Soft brush
Before cleaning, be sure to turn off the equipment
and disconnect the power plug.
•
•
•
Cleaning and Maintenance
•
Spray water to clean the dust.
CAUTION
Do not clean the display by using alkaline detergent.
Do not use sulphuric acid, hydrochloric acid, or organic solvents
(such as thinner, kerosene, and acetone) to clean the surfaces. Do
not put any stickers on it as this can damage the surface of the
air conditioner.
When you clean and inspect the heat exchanger on the outdoor
unit, contact the local service centre for help.
Make sure to prevent any injury from sharp edges of the surface
when handling the heat exchanger.
22 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 22
2017-01-20 오전 11:28:32
Cleaning the filter
Vacuum cleaner
Soft brush
30 minutes
Mild detergent
CAUTION
• Do not scrub the air filter with a brush or other cleaning utensil.
This may damage the filter.
• Do not expose the air filter to direct sunlight when drying it.
NOTE
• Clean the air filter every 2 weeks. Cleaning term may vary depending on the usage and
environmental conditions.
Cleaning and Maintenance
• If the air filter dries in a humid area, it may produce offensive odours. Clean it again and dry
it in a well-ventilated area.
English 23
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 23
2017-01-20 오전 11:28:33
Troubleshooting
If the air conditioner operates abnormally, refer to the following
chart to save time and unnecessary expenses.
Problem
Solution
• Check the power status, then operate the air
conditioner again.
• Switch on the circuit breaker, plug in the
power cord, then operate the air conditioner
The air
again.
conditioner does
not work at all.
• Make sure that the isolator is turned on.
• Check whether the Timed off function is
running. Operate the air conditioner again by
pressing the Power button.
• Check whether the Fan or Fast mode is
running. In these modes, the air conditioner
I cannot change
controls the set temperature automatically,
the temperature.
and you cannot change the set temperature.
Cleaning and Maintenance
• Check whether the set temperature is
higher in the Cool mode than the current
temperature. Press the Temperature button
on the remote control to change the set
temperature.
Cool air does not
• Check whether the air filter is blocked with
come out of the
dirt. If the air filter is blocked, the cooling
air conditioner.
performance may decrease. Remove dirt
regularly.
• Check whether the outdoor unit is covered
or installed near obstacles. Remove the
coverings and obstacles.
24 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 24
2017-01-20 오전 11:28:33
Problem
Solution
• Check whether doors or windows are open.
This may cause poor cooling performance.
Close the doors and windows.
• Check whether the air conditioner is turned
on immediately after the cooling operation
Cool air does not
stops. In this case, only the fan runs to
come out of the
protect the outdoor unit compressor.
air conditioner.
• Check whether the pipe length is too long.
When the pipe length exceeds the maximum
pipe length, the cooling performance may
decrease.
• Check whether the good'sleep function is
running. While this function is running, you
cannot control the air flow direction.
I cannot change
the fan speed.
• When the Auto, Dry, or Turbo mode
is running or the good'sleep function
is running in the Cool mode, the air
conditioner controls the fan speed
automatically and you cannot change the
fan speed.
Cleaning and Maintenance
I cannot change
the air flow
direction.
English 25
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 25
2017-01-20 오전 11:28:33
Troubleshooting
Problem
Solution
Cleaning and Maintenance
The remote
control does not
work.
• Replace the batteries in the remote control
with new ones.
• Make sure that nothing is blocking the
remote control sensor.
• Check whether there are strong lighting
apparatus near the air conditioner. Strong
light which comes from fluorescent bulbs or
neon signs may interrupt the electric waves.
The Timed on/
off function
does not work.
• Check whether you pressed the SET button
on the remote control after setting the time.
The indicator
blinks
continuously.
• Press the Power button to turn off the air
conditioner or disconnect the power plug.
If the indicator is still blinking, contact the
service centre.
Odours
permeate in the
room during
operation.
• Check whether the air conditioner is
running in a smoky area. Ventilate the
room or operate the air conditioner in the
Fan mode for 3 to 4 hours. (There are no
components used in the air conditioner that
emit a strong odour.)
• Check whether the drains are clean. Clean
them regularly.
An error is
indicated.
• If the indoor unit indicator blinks, contact
the nearest service centre. Be sure to pass
the error code to the service centre.
26 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 26
2017-01-20 오전 11:28:33
Problem
Solution
Noise is
generated.
• When refrigerant flow changes, noise may
be generated, depending on the status
of the air conditioner. This is a normal
operation.
Water drops
from the pipe
connections of
the outdoor unit.
• Condensation may develop when the
ambient temperature changes excessively.
This is a normal operation.
Cleaning and Maintenance
English 27
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 27
2017-01-20 오전 11:28:33
Installation
Safety Information on Installation
Carefully follow the precautions listed below because
they are essential to guarantee the safety of both the air
conditioner and the workers.
•
The unit contains moving parts, which should always
be kept out of the reach of children.
•
•
Always disconnect the air conditioner from the power
supply before servicing it or accessing its internal
components.
Do not attempt to repair, move, alter or reinstall the
unit. If performed by unauthorised personnel, these
operations may cause electric shocks or fires.
•
•
Verify that installation and testing operations are
performed by qualified personnel.
Do not place containers with liquids or other objects
on the unit.
•
•
Verify that the air conditioner is not installed in an
easily accessible area.
All the materials used for the manufacture and
packaging of the air conditioner are recyclable.
•
The packing material and exhaust batteries of the
remote control (optional) must be disposed of in
accordance with current laws.
•
The air conditioner contains a refrigerant that has
to be disposed of as special waste. At the end of its
life cycle, the air conditioner must be disposed of in
authorised centres or returned to the retailer so that it
can be disposed of correctly and safely.
General information
•
Carefully read the content of this manual before
installing the air conditioner and store the manual in
a safe place in order to be able to use it as reference
after installation.
•
For maximum safety, installers should always carefully
read the following warnings.
•
Store the operation and installation manual in a safe
location and remember to hand it over to the new
owner if the air conditioner is sold or transferred.
•
•
This manual explains how to install an indoor unit
with a split system with two SAMSUNG units. The use
of other types of units with different control systems
may damage the units and invalidate the warranty.
The manufacturer shall not be responsible for damages
arising from the use of non compliant units.
The manufacturer shall not be responsible for damage
originating from unauthorised changes or the improper
connection of electric and requirements set forth in the
“Operating limits” table, included in the manual, shall
immediately invalidate the warranty.
Installation of the unit
•
IMPORTANT: When installing the unit, always
remember to connect first the refrigerant tubes, then
the electrical lines. Always disassemble the electric
lines before the refrigerant tubes.
•
Upon receipt, inspect the product to verify that it has
not been damaged during transport. If the product
appears damaged, DO NOT INSTALL it and immediately
report the damage to the carrier or retailer (if the
installer or the authorised technician has collected the
material from the retailer.)
•
After completing the installation, always carry out a
functional test and provide the instructions on how to
operate the air conditioner to the user.
Installation
•
The air conditioner should be used only for the
applications for which it has been designed: the indoor
unit is not suitable to be installed in areas used for
laundry.
•
Do not use the air conditioner in environments with
hazardous substances or close to equipment that
release free flames to avoid the occurrence of fires,
explosions or injuries.
•
Do not use the units if damaged. If problems occur,
switch the unit off and disconnect it from the power
supply.
•
•
In order to help prevent electric shocks, fires or
injuries, always stop the unit, disable the protection
switch and contact SAMSUNG’s technical support if
the unit produces smoke, if the power cable is hot or
damaged or if the unit is very noisy.
•
Always remember to inspect the unit, electric
connections, refrigerant tubes and protections
regularly. These operations should be performed by
qualified personnel only.
Our units must be installed in compliance with the
spaces indicated in the installation manual to ensure
either accessibility from both sides or ability to
perform routine maintenance and repairs. The units’
components must be accessible and that can be
disassembled in conditions of complete safety either
for people or things. For this reason, where it is not
observed as indicated into the Installation Manual, the
cost necessary to reach and repair the unit (in safety,
as required by current regulations in force) with slings,
trucks, scaffolding or any other means of elevation
won’t be considered in-warranty and will be charged
to end user.
28 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 28
2017-01-20 오전 11:28:33
•
When installing the outdoor unit at the seaside, make
sure that it is not directly exposed to sea breeze. If
you cannot find an adequate place free from direct
sea breeze, construct a protection wall or a protective
fence.
–– Install the outdoor unit in a place (such as near
buildings etc.) where it can be protected from sea
breeze. Failure to do so may cause a damage to the
outdoor unit.
•
Always make sure that the power supply is compliant
with current safety standards. Always install the air
conditioner in compliance with current local safety
standards.
•
Always verify that a suitable grounding connection is
available.
•
Verify that the voltage and frequency of the power
supply comply with the specifications and that the
installed power is sufficient to ensure the operation of
any other domestic appliance connected to the same
electric lines.
•
Always verify that the cut-off and protection switches
are suitably dimensioned.
Sea breeze
Sea breeze
Outdoor unit
Sea
Power supply line, fuse, or circuit
breaker
Sea
Outdoor unit
•
If you cannot avoid installing the outdoor unit at the
seaside, construct a protection wall around to block the
sea breeze.
•
Verify that the air conditioner is connected to the
power supply in accordance with the instructions
provided in the wiring diagram included in the manual.
•
Construct a protection wall with a solid material such
as concrete to block the sea breeze. Make sure that the
height and the width of the wall are 1.5 times larger
than the size of the outdoor unit. Also, secure a space
larger than 600 mm between the protection wall and
the outdoor unit for exhausted air to ventilate.
•
Always verify that electric connections (cable entry,
section of leads, protections…) are compliant with
the electric specifications and with the instructions
provided in the wiring scheme. Always verify that all
connections comply with the standards applicable to
the installation of air conditioners.
•
Be sure not to perform power cable modification,
extension wiring, and multiple wire connection.
Sea breeze
Sea
Protection wall
Outdoor unit
Outdoor unit
Protection wall
•
Install the unit in a place where water can drain
smoothly.
•
If you have any difficulty finding installation location
as prescribed above, contact your manufacturer for
details.
•
Be sure to clean the sea water and the dust on the heat
exchanger of the outdoor unit and apply a corrosion
inhibitor on it. (At least once in a year.)
–– It may cause electric shock or fire due to poor
connection, poor insulation, or current limit
override.
–– When extension wiring is required due to power
line damage, refer to "Step 2.2 Optional: Extending
the power cable" in the installation manual.
Installation
English 29
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 29
2017-01-20 오전 11:28:33
Preparation
Step 1.1 Choosing the installation
location
Overview of installation location requirements
CAUTION
•
Comply with the length and height limits described in
the figure above.
Minimum clearances for the outdoor unit
Wall
100 mm or more
125 mm
or more
125 mm
or more
Minimum clearance in mm
300
Drain hose hole
You can select the direction of
draining (left or right).
600
Maximum pipe height: 15 m
Maximum pipe length: 30 m
Air flow direction
Make at least one round to
reduce noise and vibration.
Top view
Side view
When installing 1 outdoor unit
(6 cases)
(Unit: mm)
1500
300
The actual units may look different from
the images depicted here.
(Unit : m)
Pipe height
Maximum
8
18
3
25
10
24
3
25
10
2000
Outdoor
Unit
Outer wall
Installation
Indoor
Unit
Cut insulation to have
rainwater drained
CAUTION
Make a U-trap (A) on the
pipe (which is connected to
the indoor unit) at outer wall
and cut the bottom part of
the insulation (about 10 mm)
to prevent rainwater from
getting inside through the
insulation.
500
150
300
1500
20
600
300
Maximum
3
1500
Minimum
09/12
300
Model
Pipe length
30 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 30
2017-01-20 오전 11:28:34
Step 1.2 Checking and preparing
accessories and tools
When installing more than 1 outdoor unit
(5 cases)
(Unit: mm)
Accessories
600
3000
3000
200
600
Installation plate (1)
09/12
Installation plate (1)
18
installation plate (1)
24
Remote control (1)
Remote control battery (2)
User Manual and
Installation Manual (1)
300
1500
600
Accessories in the indoor unit package
1500
300
1500
600
500
500
300
600
600
300
300
CAUTION
•
If the outdoor unit is installed with any insufficient
clearance, it may generate sound and affect the whole
product.
•
Be sure to install the outdoor unit in a level place
where its vibration does not affect the whole product.
Installation
English 31
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 31
2017-01-20 오전 11:28:37
Preparation
Optional accessories
Insulated assembly pipe,
Ø 6.35 mm (1)
Insulated assembly pipe,
Ø 12.70 mm (1)
18
Drain Hose, 2 m long (1)
NOTE
Insulated assembly pipe,
Ø 9.52 mm (1)
09/12
Insulated assembly pipe,
Ø 15.88 mm (1)
24
•
A flare nut is attached to the end of each pipe of an
evaporator or a service port. Use flare nuts when
connecting the pipes.
•
Wire assembly cables are optional. If they are not
supplied, use standard cables.
•
The drain plug and the rubber legs are included only
when the air conditioner is supplied without assembly
pipes.
•
If these accessories are supplied, they are in the
accessory package or outdoor unit package.
Foam Insulation(1)
Tools
Pipe clamp A (3)
Pipe clamp B (3)
General tools
•
Vinyl tape (2)
Putty 100 g (1)
M4 x 25 tapped screw (6)
PE T3 foam tube insulation (1)
Drain plug (1)
Cement nail (6)
Vacuum pump
(Backward flowing
prevention)
•
Manifold gauge
•
Stud finder
•
Torque wrench
•
Pipe cutter
•
Reamer
•
Pipe bender
•
Spirit level
•
Screwdriver
•
Spanner
•
Drill
•
L-wrench
•
Measuring tape
Tools for test operation
Accessories in the outdoor unit package
3-wire
Assembly Cable(1)
09/12/18
4-wire
Assembly Cable(1)
24
•
Thermometer
•
Resistance meter
•
Electroscope
Step 1.3 Drilling a hole through the
wall
Rubber Leg(4)
Installation
Before fixing the installation plate to a wall and then fixing
the indoor unit to the installation plate, a window frame,
or a gypsum board, you must determine the position of a
hole (with 65 mm inner diameter) through which the pipe
bundle (consisting of power and communication cables,
refrigerant pipes, and drain hose) will pass and then drill
that hole.
1
Determine the position of a 65 mm hole in
consideration of the possible directions of the pipe
bundle and the minimum distances between the hole
and the installation plate.
32 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 32
2017-01-20 오전 11:28:38
2
Drill the hole.
CAUTION
Right
Left
Rear right or left
•
Be sure to drill only one hole.
•
Make sure that the hole slants downwards so that the
drain hose slants downwards to drain water well.
Wall
Bottom right
<Possible directions of the pipe bundle>
Indoor unit
CAUTION
•
Drain hose
<The hole slants downwards>
If changing the pipe direction from left to right, do not
drastically bent it but slowly turn it in the opposite
direction as shown. Otherwise, the pipe may be
damaged in the process.
Step 1.4 Taping the pipes, cables, and
drain hose
1
Wrap foam insulation on parts without insulation on
the ends of the refrigerant pipes, as shown in the
figure. This wrapping minimises condensation problem.
Insulation
Refrigerant pipes
2
<Minimum distances between the hole and
the installation plate>
Wind the refrigerant pipes, power cable,
communication cable and drain hose with vinyl tape to
make a pipe bundle.
Installation plate
Refrigerant pipes
(assembly pipe)
Vinyl tape
(Unit : mm)
A
B
C
D
Power and communication cables
(assembly cable)
18/24
52
144
69
50
Drain hose
18
49
51
77
49
24
52
51
79
52
Installation
Model
09/12/18 Pipe bundle hole : Ø 65mm
24 Pipe bundle hole : Ø 90mm
English 33
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 33
2017-01-20 오전 11:28:40
Indoor Unit Installation
Step 2.1 Connecting the cables
(assembly cable)
NOTE
•
Each wire is labelled with the corresponding terminal
number.
•
Use shield cable (Category 5; less than 50pF/m) for
noisy environmental site.
•
Power supply cords of parts of appliances for outdoor
use shall not be lighter than polychloroprene sheathed
flexible cord. (Code designation IEC: 60245 IEC 66/
CENELEC: H07RN-F, IEC: 60227 IEC 53/CENELEC:
H05VV-F)
•
Power & Communication cable shall not exceed 30m.
•
For the terminal block wiring, use a wire with a
ring terminal socket only. Regular wires without a
ring terminal socket may become a hazard due to
overheating of the electrical contact during installation.
•
If you need to extend the pipe, be sure to extend the
cable too. The maximum length of each of the cable
and pipe used should not exceed 20(09/12) and
25(18/24) metres.
•
Do not connect two or more different cables to extend
the length. This connection may cause fire.
•
Each circular terminal must match the size of its
corresponding screw in the terminal block.
•
After connecting the cables, make sure that terminal
numbers on the indoor and outdoor units match.
•
Ensure that power and communication cables are
separated, they must not be in the same cable.
•
Connect the wires firmly so that wires cannot be pulled
out easily. (If they are loose, it could cause burn-out of
the wires.)
Control box
Before
connecting
Correct
Upside down
Damaged
CAUTION
Non-circular
After
connecting
Correct
(Front view)
Correct
(Side view)
Upside down
Non-fitted
<Circular terminal>
09/12/18
24
WARNING
Fasten the screws for the wire holders.
Model
09/12
18
24
Power cable
(Outdoor unit)
3G X 1.5 mm²,
H05VV-F
3G X 2.5 mm²,
H05VV-F
3G X 2.5 mm²,
H05VV-F
Outdoor-to-indoor 3G X 1.5 mm²,
power cable
H07RN-F
3G X 2.5 mm²,
H07RN-F
4G X 2.5 mm²,
H07RN-F
Type GL
25A
Installation
•
When performing electrical and earthing works,
be sure to comply with the 'technical standards of
electrical installations' and the 'wiring regulations' in
the local regulations.
•
Tighten the terminal block screw to 1.2-1.8 N•m (1218 kgf•cm).
34 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 34
2017-01-20 오전 11:28:41
Step 2.2 Optional: Extending the power cable
1
•
The compression dimension should be 8.0.
Prepare the following tools.
Tools
Spec
Compression
dimension
Shape
Crimping pliers
MH-14
Connection sleeve
(mm)
20xØ7.0 (HxOD)
Insulation tape
Width 18 mm
Contraction tube
(mm)
50xØ8.0 (LxOD)
•
After compressing it, pull both sides of the wire to
make sure it is firmly pressed.
Method 1
2
Method 2
Compress it 4 times
Compress it 4 times
5 mm
5 mm
As shown in the figure, peel off the shields from the
rubber and wire of the power cable.
•
Peel off 20 mm of cable shields from the
preinstalled tube.
5
CAUTION
•
For information about the power cable specifications for
indoor and outdoor units, refer to the installation manual.
•
After peeling off cable wires from the pre-installed tube,
insert a contraction tube.
Wrap it with the insulation tape twice or more and
position your contraction tube in the middle of the
insulation tape.
Three or more layers of insulation are required.
Method 1
Method 2
Insulation tape
Insulation tape
Power cable
40 mm
20
20
20
60
6
Apply heat to the contraction tube to contract it.
120
180
35 mm
Contraction tube
(Unit: mm)
Pre-installed tube for the power cable
(Unit: mm)
20
3
Connection sleeve
Insulation tape
Method 2
Connection sleeve
Using a crimping tool, compress the two points and
flip it over and compress another two points in the
same location.
After tube contraction work is completed, wrap it with
the insulation tape to finish.
CAUTION
•
Make sure that the connection parts are not exposed
to outside.
•
Be sure to use insulation tape and a contraction tube
made of approved reinforced insulating materials that
have the same level of withstand voltage with the
power cable. (Comply with the local regulations on
extensions.)
Installation
Method 1
4
7
Insert both sides of core wire of the power cable into
the connection sleeve.
• Method 1: Push the core wire into the sleeve from
both sides.
• Method 2: Twist the wire cores together and push
it into the sleeve.
English 35
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 35
2017-01-20 오전 11:28:42
Indoor Unit Installation
WARNING
•
CAUTION
In case of extending the
electric wire, please DO NOT
use a round-shaped pressing
socket.
–– Incomplete wire
connections can cause electric shock or a fire.
Step 2.3 Installing and connecting the
drain hose
1
Install the drain hose.
•
Make sure that the indoor unit is in upright position
when you pour water to check for leakage. Make sure
that the water does not overflow onto the electrical
part.
•
If the diameter of the connection hose is smaller than
the product's drain hose, water leakage may occur.
•
Inadequate installation may cause water leakage.
•
If the drain hose is routed inside the room, insulate the
hose so that dripping condensation does not damage
the furniture or floors.
•
Do not box in or cover the drain hose connection.
Drain hose connection must be easily accessible and
serviceable.
Step 2.4 Optional: Extending the drain
hose
Drain hose
Assembly pipe
Connection hose
Drain hose (A)
Extension drain hose (B)
Wall
40~45mm
Indoor unit
Drain hose
Slant downwards
(A)
Slant upwards
(B)
Dipped in water
Drain hose
Extension drain hose
5 cm
less
Bent
2
Too small
clearance
Ditch
Too small
clearance
20 mm or more
Foam insulation
Installation
Pour water into the drain pan. Check whether the hose
is well drained.
Vinyl tape
36 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 36
2017-01-20 오전 11:28:43
Step 2.5 Optional: Changing the
direction of the drain hose
Drain pan outlet
Rubber cap
Pour water in the direction of arrow.
There are 2 refrigerant pipes of different diameters:
•
The smaller one is for the liquid refrigerant
•
The larger one is for the gas refrigerant
A short liquid refrigerant pipe and a short gas refrigerant
pipe are already fitted to the air conditioner. The
connection procedure for the refrigerant pipes varies
according to the exit position of each pipe when facing
the wall:
Left(A)
Right(B)
Underside(C)
<Front view>
1
Cut out the appropriate knock-out piece (A, B, C) on
the rear of the indoor unit unless you connect the pipe
directly from the rear.
2
Smooth the cut edges.
3
Remove the protection caps of the pipes and connect
the assembly pipe to each pipe. Tighten the nuts first
with your hands, and then with a torque wrench,
applying the following torque:
Direction of the drained water
Outer diameter (mm)
Torque (N•m)
Torque (kgf•cm)
ø 6.35
14 to 18
140 to 180
ø 9.52
34 to 42
350 to 430
ø 12.70
49 to 61
500 to 620
ø 15.88
68 to 82
690 to 830
<Side view>
CAUTION
•
NOTE
Make sure that the indoor unit is in upright position
when you pour water to check for leakage. Make sure
that the water does not overflow onto the electrical
part.
Connect indoor and outdoor units with field-supplied
copper pipes by means of flare connections. Use insulated
seamless refrigeration grade pipe only, (Cu DHP type
according to ISO1337), degreased and deoxidized, suitable
for operating pressures of at least 4200 kPa and for burst
pressure of at least 20700 kPa. Under no circumstances
must sanitary type copper pipe be used.
If you want to shorten or extend the pipes, see
Step 2.7 Shortening or extending the refrigerant
pipes (assembly pipe) on page 38.
4
Cut off the remaining foam insulation.
5
If necessary, bend the pipe to fit along the bottom
of the indoor unit. Then pull it out through the
appropriate hole.
6
•
The pipe should not project from the rear of the
indoor unit.
•
The bending radius should be 100 mm or more.
Pass the pipe through the hole in the wall.
Installation
Step 2.6 Installing and connecting
the assembly pipes to the refrigerant
pipes (assembly pipe)
•
English 37
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 37
2017-01-20 오전 11:28:44
Indoor Unit Installation
NOTE
•
Flare nut
The pipe will be insulated and fixed permanently into
position after finishing the installation and the gas leak
test. For further details. see Step 4.1 Performing the
gas leak tests on page 43.
Indoor outlet pipe
(Unit: mm)
CAUTION
•
•
Connecting pipe
Outer diameter (mm) Torque (N•m)
Tighten the flare nut with a torque wrench according
to specified method. If the flare nut is over-tightened,
the flare may break and cause refrigerant gas leakage.
Do not box in or cover the pipe connection. All
refrigerant pipe connection must be easily accessible
and serviceable.
Step 2.7 Shortening or extending the
refrigerant pipes (assembly pipe)
Pipe cutter
Torque (kgf•cm)
ø 6.35
14 to 18
140 to 180
ø 9.52
34 to 42
350 to 430
ø 12.70
49 to 61
500 to 620
ø 15.88
68 to 82
690 to 830
CAUTION
•
If you need a pipe longer than specified in piping
codes and standards, you must add refrigerant to the
pipe. Otherwise, the indoor unit may freeze.
•
While removing burrs, put the pipe face down to make
sure that the burrs do not get in to the pipe.
Pipe
Liquid service port
<High pressure>
Oblique
90°
Rough
D
Gas service port
<Low pressure>
Burr
90°±2°
A
45°±2°
L
R 0.4 to 0.8
Pipe
Correct
Flare
D
Installation
(Unit: mm)
Outer diameter (D)
Depth (A)
Flare dimension (L)
ø 6.35
1.3
8.7 to 9.1
ø 9.52
1.8
12.8 to 13.2
ø 12.70
2.0
16.2 to 16.6
ø 15.88
2.2
19.3 to 19.7
Inclined
Cracked
Uneven
thickness
Damaged
surface
<Flare nut>
38 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 38
2017-01-20 오전 11:28:44
NOTE
•
Excessive torque may cause gas leakage. When
extending the pipe with welding or brazing, ensure
that nitrogen is used during the welding or brazing
process. The joint must be accessible and serviceable.
•
Tighten the flare nut at the specified torque. If the flare
nut is over-tightened, it may break to cause leakage of
refrigerant gas.
CAUTION
(Unit : mm)
Step 2.8 Fixing the installation plate
Model
A
B
C
D
09/12
52
144
69
50
18
49
51
77
49
24
52
51
79
52
09/12/18 Pipe bundle hole: Ø 65 mm
You can install the indoor unit on a wall, window frame, or
gypsum board.
24 Pipe bundle hole: Ø 90 mm
WARNING
•
Make sure that the wall, window frame, or gypsum
board can withstand the weight of the indoor unit. If
you install the indoor unit in a place where it is not
strong enough to withstand the unit's weight, the unit
could fall and cause injury.
NOTE
•
If you mount the plate to a concrete wall using plastic
anchors, make sure that gaps between the wall and the
plate, created by projected anchor, is less than 20 mm.
When fixing the indoor unit on a window frame
When fixing the indoor unit on a wall
1
Fix the installation plate to the wall giving attention to the
weight of the indoor unit.
Determine the positions of the wooden uprights to be
attached to the window frame.
2
Attach the wooden uprights to the window frame
giving attention to the weight of the indoor unit.
3
Attach the installation plate to the wooden upright
using tapping screws.
Plastic anchor
When fixing the indoor unit on a gypsum board
20 mm Wall
1
Use stud finder to find out locations of the studs.
2
Fix the plate hanger on two studs.
CAUTION
If you fix the indoor unit on a gypsum board, use
only specified anchor bolts on reference positions.
Otherwise, the gypsum surrounding the joints may
crumble over time and cause the screws to be
loosened and stripped. This may lead to physical injury
or equipment damage.
•
Search for other spots if there are less than two studs,
or the distance between the studs are different from
the plate hanger.
•
Fix the installation plate without inclining to one side.
Installation
•
English 39
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 39
2017-01-20 오전 11:28:46
Outdoor Unit Installation
Step 3.1 Fixing the outdoor unit in
place
Optional: Fixing the outdoor unit to a wall with
a rack
Soft rubber designed to cut off vibration from
rack to wall (not supplied with product)
Y
X
Rubber leg
(Unit : mm)
Model
X
Y
90
700
275
12/18
770
300
24
845
363
1
Place the outdoor unit as directed on the top of the
unit to let the discharged air out properly.
2
Fix the outdoor unit in level to an appropriate support
using anchor bolts.
Soft rubber designed to cut off residual vibration
from outdoor unit to rack (not supplied with product)
NOTE
•
Make sure that the wall can support the weights of the
rack and the outdoor unit.
•
Install the rack close to the column as much as
possible.
NOTE
•
Secure the rubber legs to help prevent the generation
of noise and vibration.
•
If the outdoor unit is exposed to strong winds, install
shield plates around the outdoor unit so that the fan
can operate correctly.
Step 3.2 Connecting the cables and
the refrigerant pipes
09/12/18
To indoor unit
24
To indoor unit
Installation
CAUTION
•
Be sure to fix the power cables and communication
cable with a cable clamp.
40 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 40
2017-01-20 오전 11:28:47
CAUTION
•
Control box
Remove the screw for the
control box cover
1
When installing, make sure there is no leakage. When
recovering the refrigerant, ground the compressor first
before removing the connection pipe. If the refrigerant
pipe is not properly connected and the compressor
works with the stop valve open, the pipe inhales the
air and it makes the pressure inside of the refrigerant
cycle abnormally high. It may cause explosion and
injury.
Leave the system in the standby mode.
WARNING
Remove the gas and liquid
service port caps
•
For connecting the
refrigerant pipes
2
Gas service port
<Low pressure>
Liquid service port
<High pressure>
Connect the gas and liquid
refrigerant pipes
Do not turn on the system! This is necessary for
better vacuum operation (full OPEN position of
Electronic Expansion Valve).
Connect the charging hose of the low pressure side
of manifold gauge to a gas service port as seen in the
picture.
3
15 minutes
Valve
4
Vacuum
Pump
Step 3.3 Evacuating the air
The outdoor unit is loaded with sufficient R-410A
refrigerant. Do not vent R-410A into atmosphere: it is a
fluorinated greenhouse gas, covered by Kyoto Protocol,
with a Global Warming Potential (GWP) = 2088. You
should evacuate the air in the indoor unit and in the
pipe. If air remains in the refrigerant pipes, it affects the
compressor. It may cause reduction of cooling capacity and
malfunction. Use a vacuum pump.
(Backward flowing prevention)
Liquid service port <Low pressure>
5
Installation
Liquid service port <High pressure>
English 41
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 41
2017-01-20 오전 11:28:48
Outdoor Unit Installation
3
Open the valve of the low pressure side of manifold
gauge anticlockwise.
4
Evacuate the air in the connected pipes using the
vacuum pump for about 15 minutes.
5
R-410A is a mixed type of refrigerant. It is necessary for
recharging under conditions of liquid. When recharging
refrigerant from the refrigerant cylinder to the equipment,
take the following instructions:
Before recharging, check whether the cylinder has
a siphon or not. There are two ways to recharge the
refrigerant:
•
Make sure that pressure gauge shows -0.1 MPa
(-76 cmHg, 5 torr) after about 10 minutes. This
procedure is very important to avoid a gas leak.
•
Close the valve of the low pressure side of
manifold gauge clockwise.
•
Turn off the vacuum pump.
•
Check for 2 minutes if there is any pressure
change.
•
Remove the hose of the low pressure side of
manifold gauge.
Charge the refrigerant
standing the cylinder upright.
Charge the refrigerant turning
the cylinder upside down.
Set a valve cork of liquid and gas service port to the
open position.
<Cylinder with siphon>
<Cylinder without siphon>
Step 3.4 Adding refrigerant
If you use a pipe longer than the length specified in
the piping codes and standards, you must add 15g
(for09/12/18) and 30g (for24) of refrigerant
R-410A for each extra metre. If you use a pipe shorter that
the length specified in the piping codes and standards, the
evacuating time is normal. Refer to the Service Manual for
further details.
Siphon
NOTE
•
If R-410A refrigerant is charged with gas, the
composition of the charged refrigerant changes and
the characteristics of the equipment vary.
•
During the measuring operation of refrigerant quantity
added, use electronic scales. If cylinder doesn't have
siphon, upset it.
CAUTION
•
The remaining air in the Refrigeration cycle, which
contains moisture, may cause malfunction of the
compressor.
•
Always contact the service centre or a professional
installation agency for product installation.
Installation
42 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 42
2017-01-20 오전 11:28:48
Installation Inspection
Step 4.1 Performing the gas leak tests
1
Before inspecting the leakage, use a torque wrench
to close the cap for the stop valve. (Comply with a
tightening torque for each size of the diameter, and
tighten the cap firmly to prevent any leakage.)
Test parts for the
indoor unit
Tightening torque for body
cap (Refer to the table)
Spindle
Step 4.2 Performing final check and
trial operation
Charging core
1
R-22: Thread of the screw - 7/16-2OUNF
R-410A: Thread of the screw -1/2-2OUNF
Tightening torque for charging port cap (Refer to the table)
Outer diameter
(mm)
Tightening torque
Body cap
(N•m)
Charging port cap (N•m)
Check the following:
•
Strength of the installation site
•
Tightness of pipe connection to detect gas leak
•
Electric wiring connection
•
Heat-resistant insulation of the pipe
•
Drainage
•
Grounding conductor connection
•
Correct operation (Take the following steps.)
ø 6.35
20 to 25
ø 9.52
20 to 25
ø 12.70
25 to 30
ø 15.88
30 to 35
•
The indicator on the indoor unit lights up.
Over ø 19.05
35 to 40
•
The airflow blade opens and the fan gears up for
operation.
2
10 to 12
Press the
(Power) button on the remote control to
check the following:
( 1 N•m = 10 kgf•cm )
3
2
Insert inert gas into the pipes connected to indoor and
outdoor units.
3
Test leakage on the connection parts of the indoor and
outdoor units with soap lather or liquid.
•
In Cool mode, use the Temperature button to set
the set temperature to 16 °C.
•
Check whether, approximately 3 to 5 minutes
later, the outdoor unit starts, and a cool air blows
out.
•
After 12 minutes of stationary condition, check
the indoor unit air treatment.
4
Press the
(Air swing) button to check whether the
airflow blades work properly.
5
Press the
(Power) button to stop the trial operation.
Pumping down refrigerant
Pump-down is an operation intended to collect all the
system refrigerant in the outdoor unit. This operation must
be carried out before disconnecting the refrigerant tubing
in order to avoid refrigerant loss to the atmosphere.
Installation
Test parts for the
indoor unit
Press the
(Mode) button to select Cool mode. Then
take the following sub-steps:
English 43
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 43
2017-01-20 오전 11:28:49
WARNING
After installing the product, be sure to perform leak
tests on the piping connections.After pumping down
refrigerant to inspect or relocate the outdoor unit, be
sure to stop the compressor and then remove the
connected pipes.
‐ Do not operate the compressor while a valve is
open due to refrigerant leakage from a pipe or an
unconnected or incorrectly connected pipe. Failure
to do so may cause air to flow into the compressor
and too a high pressure to develop inside the
refrigerant circuit, leading to an explosion or
product malfunction.
Memo
Installation
English 45
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 45
2017-01-20 오전 11:28:50
A
U
QUESTIONS OR COMMENTS?
COUNTRY
CALL
SOUTH AFRICA
0860 SAMSUNG (726 7864)
BOTSWANA
8007260000
NAMIBIA
08 197 267 864
ZAMBIA
0211 350370
MAURITIUS
800 2550
REUNION
0262 50 88 80
ANGOLA
940 271 635
MOZAMBIQUE
847267864 / 827267864
NIGERIA
0800-726-7864
Ghana
0800-100077
Cote D’lvoire
8000 0077
SENEGAL
800-00-0077
CAMEROON
67095-0077
KENYA
0800 545 545
UGANDA
0800 300 300
TANZANIA
0800 780 089
RWANDA
9999
BURUNDI
200
DRC
499999
SUDAN
1969
OR VISIT US ONLINE AT
AR
••
••
www.samsung.com/support
www.samsung.com/africa_en/support
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 32
www.samsung.com/africa_fr/support
www.samsung.com/support
2017-01-20 오전 11:28:24
Was this manual useful for you? yes no
Thank you for your participation!