INSTALLATION MANUAL
AIR CONDITIONER
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it
thoroughly.
TYPE : MULTI TYPE WALL MOUNTED
www.lg.com
P/NO : MFL63750401
Multi Type Air Conditioner Installation Manual
TABLE OF CONTENTS
Installation
Requirements
Safety Precautions............................3
Introduction........................................6
Symbols used in this manual..........6
Installation ..........................................7
Installation parts...............................7
Installation tools ...............................7
Installation map................................8
Selecting the best location .............8
Fixing installation plate ....................9
Drilling a hole in the wall .................9
Flaring work ...................................10
Connecting the piping ..................11
Connecting the cables ..................16
Required Parts
Required Tools
❏ Some pieces of type "A" screws
❏ Level gauge
❏ Connecting cable
❏ Screw driver
❏ Installation guide map
❏ Electric drill
❏ Pipes: Gas side
Liquid side
❏ Hole core drill(ø70mm)
❏ Insulation materials
❏ Additional drain pipe
(Outer diameter ..............15.5mm)
❏ Some pieces of type "B" screws
❏ Horizontal meter
❏ Flaring tool set
❏ Specified torque wrenches
1.8kg.m, 4.2kg.m, 5.5kg.m,
6.6kg.m
(different depending on model No.)
❏ Spanner ........................Half union
❏ A glass of water
❏ Hexagonal wrench(4mm)
❏ Gas-leak detector
❏ Vacuum pump
Checking the drainage..................17
❏ Gauge manifold
Test running ...................................18
❏ Owner's manual
❏ Thermometer
❏ Remote controller holder
2 Multi Type Air Conditioner
Safety Precautions
Safety Precautions
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
■ The meanings of the symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
■ Installation
Always perform grounding.
• Otherwise, it may cause
electrical shock.
Securely attach the
electrical cover to indoor
and pipe cover to outdoor
unit.
• If the electrical part cover to
indoor unit and pipe cover to
outdoor unit are not attached
securely, it could result in a
fire or electric shock due to
dust, water, etc.
Donʼt use a power cord, a
plug or a loose socket
which is damaged.
For installation of the product,
always contact the service
center or a professional
installation agency.
• Otherwise, it may cause a fire
or electrical shock.
• Otherwise, it may cause a fire,
electrical shock, explosion or
injury.
Always install a current
leakage breaker and a
dedicated switching board.
• No installation may cause a
fire and electrical shock.
Ensure that an installation frame of the
outdoor unit is not damaged due to use for
a long time.
• It may cause injury or an accident.
Do not keep or use
flammable gases or
combustibles near the air
conditioner.
• Otherwise, it may cause a fire
or the failure of product.
Do not disassemble or repair the product
randomly.
• It will cause a fire or electrical shock.
Installation Manual 3
ENGLISH
To prevent the injury of the user or other people and property damage, the following instructions
must be followed.
■ Be sure to read before installing the air conditioner.
■ Be sure to observe the cautions specified here as they include important items related to safety.
■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
Safety Precautions
Do not install the product at a place where
there is concern of falling down.
• Otherwise, it may result in personal injury.
Use caution when unpacking and installing.
• Sharp edges may cause injury.
Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge.
Do not compress air or Oxygen and Do not use Flammable gases.
Otherwise, it may cause fire or explosion.
• There is the risk of death, injury, fire or explosion.
n Operation
Do not share the outlet with
other appliances.
• It will cause an electric shock
or a fire due to heat
generation.
Take care so that the power
cord may not be pulled
during operation.
• Otherwise, it may cause a fire
or electrical shock.
Take the power plug out if
necessary, holding the head
of the plug and do not touch
it with wet hands.
• Otherwise, it may cause a fire
or electrical shock.
Do not allow water to run
into electrical parts.
Do not use the damaged
power cord.
• Otherwise, it may cause a fire
or electrical shock.
Unplug the unit if strange
sound, smell, or smoke
comes from it.
• Otherwise, it may cause
electrical shock or a fire.
Do not use the power cord
near the heating tools.
• Otherwise, it may cause a fire
and electrical shock.
Hold the plug by the head
when taking it out.
• Otherwise, it may cause the
• It may cause electric shock
failure of machine or electrical
and damage.
shock.
Do not step on the indoor/outdoor unit and
do not put anything on it.
• It may cause an injury through dropping of the
unit or falling down.
When the product is submerged into water,
always contact the service center.
• Otherwise, it may cause a fire or electrical
shock.
4 Multi Type Air Conditioner
Do not modify or extend the
power cord randomly.
• Otherwise, it may cause a fire
or electrical shock.
Keep the flames away.
• Otherwise, it may cause a fire.
Do not open the inlet of the
indoor/outdoor unit during
operation.
• Otherwise, it may cause
electrical shock and failure.
Never touch the metal parts
of the unit when removing
the filter.
• They are sharp and may
cause injury.
Do not place a heavy object on the power
cord.
• Otherwise, it may cause a fire or electrical
shock.
Take care so that children may not step on
the outdoor unit.
• Otherwise, children may be seriously injured
due to falling down.
Safety Precautions
Install the drain hose to ensure that drain
can be securely done.
Install the product so that the noise or hot
wind from the outdoor unit may not cause
any damage to the neighbors.
• Otherwise, it may cause water leakage.
• Otherwise, it may cause dispute with the
neighbors.
Always inspect gas leakage after the
installation and repair of product.
Keep level parallel while installing the
product.
• Otherwise, it may cause the failure of product.
• Otherwise, it may cause vibration or water
leakage.
■ Operation
Avoid excessive cooling and perform
ventilation sometimes.
Use a soft cloth to clean. Do not use wax,
thinner, or a strong detergent.
• Otherwise, it may do harm to your health.
• The appearance of the air conditioner may
deteriorate, change color, or develop surface
flaws.
Do not use the appliance for special
purposes such as preserving animals
vegetables, precision machine, or art articles.
• Otherwise, it may damage your properties.
Do not place obstacles around the flow inlet
or outlet.
• Otherwise, it may cause the failure of
appliance or an accident.
Installation Manual 5
ENGLISH
■ Installation
Introduction
Introduction
Symbols used in this Manual
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to
the air conditioner.
NOTICE
This symbol indicates special notes.
6 Multi Type Air Conditioner
Installation
Installation
ENGLISH
Read carefully, and then follow step by step.
Installation Parts
Type 1
Type 2
Installation plate
Installation plate
Type "B" screw
Type "B" screw
Type "A" screw (6 EA)
Type "A" screw (8 EA)
Remote control holder
Remote control holder
Installation Tools
Figure
Name
Figure
Name
Screw driver
Ohmmeter
Electric drill
Hexagonal wrench
Measuring tape, Knife
Ammeter
Hole core drill
Gas-leak detector
Spanner
Thermometer,
Horizontal meter
Torque wrench
Flaring tool set
Installation Manual 7
Installation
Installation Map
Installation plate
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealant)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.
Vinyl tape (Wide)
Saddle
• Apply after carrying out a
drainage test.
• To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
- The feature can be changed according to type of model.
NOTICE
You should purchase the installation parts.
Gas side piping
(Optional Parts)
Liquid side piping
(Optional Parts)
Additional drain pipe
Select the best Location
1. There should not be any heat or steam near
the unit.
2. Select a place where there are no obstacles
around the unit.
3. Make sure that condensation drainage can
be conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and
the left (or right) of the unit is more than
100mm. The unit should be installed as high
as possible on the wall, allowing a minimum
of 200mm from ceiling.
6. Use a metal detector to locate studs to
prevent unnecessary damage to the wall.
More than
100
More than 200
More than
100
More than 2300
(Unit : mm)
Install the indoor unit on the wall where the height from the floor is more than 2300mm.
8 Multi Type Air Conditioner
Installation
Fixing Installation Plate
1. Mount the installation plate on the wall
with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
ENGLISH
The wall you select should be strong and
solid enough to prevent vibration
Installation Plate
Chassis
Hook
Type “A”
<Type 1>
Installation Plate
Chassis
Hook
Type “A”
110mm
<Type 2>
110mm
2. Measure the wall and mark the centerline.
It is also important to use caution
concerning the location of the installation
plate-routing of the wiring to power outlets
is through the walls typically. Drilling the
hole through the wall for piping
connections must be done safely.
Installation plate
Ø65mm
90mm
Left rear piping
<Type 1>
Ø65mm
70mm
Right rear piping
Installation plate
Ø65mm
Ø65mm
133mm
100mm
Left rear piping
<Type 2>
Right rear piping
Drill a Hole in the Wall
WALL
Outdoor
5-7mm
Indoor
(3/16"~5/16")
• Drill the piping hole with a ø65mm hole core
drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the
outdoor side.
Installation Manual 9
Installation
Flaring Work
Main cause for gas leakage is due to defect of flaring work. Carry out correct flaring work in the
following procedure.
Cut the pipes and the cable.
1. Use the piping kit accessory or the pipes
purchased locally.
2. Measure the distance between the indoor and
the outdoor unit.
Copper
pipe
Slanted Uneven Rough
90
3. Cut the pipes a little longer than measured
distance.
4. Cut the cable 1.5m longer than the pipe length.
Burrs removal
Pipe
1. Completely remove all burrs from the cut cross
section of pipe/tube.
Reamer
2. While removing burrs put the end of the copper
tube/pipe in a downward direction while
removing burrs location is also changed in
order to avoid dropping burrs into the tubing.
Point down
Flare nut
Putting nut on
• Remove flare nuts attached to indoor and
outdoor unit, then put them on pipe/tube having
completed burr removal.
(not possible to put them on after finishing flare
work)
Copper tube
Flaring work
Outside diameter
mm
inch
Ø6.35
1/4
Ø9.52
3/8
Ø12.7
1/2
Ø15.88
5/8
Ø19.05
3/4
10 Multi Type Air Conditioner
A
mm
1.1~1.3
1.5~1.7
1.6~1.8
1.6~1.8
1.9~2.1
Bar
Handle
"A"
1. Firmly hold copper pipe in a bar with the
dimension shown in below table.
2. Carry out flaring work with the flaring tool.
Bar
Yoke
Cone
Copper pipe
Clamp handle
Red arrow mark
Installation
Check
1. Compare the flared work with the figure by.
Smooth all round
Inside is shiny without scratches
= Improper flaring =
Even length
all round
Inclined Surface Cracked Uneven
damaged
thickness
Connecting the Piping
Indoor
1. Prepare the indoor unit's piping and drain hose
for installation through the wall.
2. Remove the plastic tubing retainer(see the
illustration by) and pull the tubing and drain
hose away from chassis.
3. Replace only the plastic tubing holder 1, not
the holder 2 in the original position.
For right rear piping
1. Route the indoor tubing and the drain hose in
the direction of rear right.
2. Insert the connecting cable into the indoor unit
from the outdoor unit through the piping hole.
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy
connection later.
Drain hose
3. Tape the tubing, drain hose, and the
connecting cable. Be sure that the drain hose
is located at the lowest side of the bundle.
Locating at the uper side can cause drain
pan to overflow inside the unit.
If the drain hose is routed inside the room,
insulate the hose with an insulation material*
so that dripping from "sweating"(condensation)
will not damage furniture or floors.
*Foamed polyethylene or equivalent is
recommended.
Tape
Connecting
pipe
Drain hose
Connecting cable
Installation Manual 11
ENGLISH
2. If a flared section is defective, cut it off and
do flaring work again.
Installation
4. Indoor unit installation
Hook the indoor unit onto the upper portion of
the installation plate.(Engage the two hooks
of the rear top of the indoor unit with the
upper edge of the installation plate.) Ensure
that the hooks are properly seated on the
installation plate by moving it left and right.
Connecting
Drain hose
Press the lower left and right sides of the unit
against the installation plate until the hooks
engage into their slots(clicking sound).
Connecting the piping to the indoor unit and
drain hose to drain pipe.
Indoor unit tubing
Flare nut
1. Align the center of the pipes and sufficiently
tighten the flare nut by hand.
Open-end wrench (fixed)
Flare nut
2. Tighten the flare nut with a wrench.
Outside diameter
mm
inch
Ø6.35
1/4
Ø9.52
3/8
Ø12.7
1/2
Ø15.88
5/8
Torque
kgf.m
1.8~2.5
3.4~4.2
5.5~6.6
6.3~8.2
Pipes
Wrench
Connection pipe
Indoor unit tubing
Type "B" screw
Drain hose
Clamp
Boss
3. Mount the clamp on the boss with a type "B"
screw.(optional)
4. When extending the drain hose at the indoor
unit, install the drain pipe.
Drain pipe
Indoor unit drain hose
Adhesive
Wrap the insulation material around the
connecting portion.
1. Overlap the connection pipe insulation
material and the indoor unit pipe insulation
material. Bind them together with vinyl tape
so that there may be no gap.
2. Wrap the area which accommodates the rear
piping housing section with vinyl tape.
Vinyl tape(narrow)
Plastic bands Insulation material
Indoor unit pipe
Connection pipe
Wrap with vinyl tape
Vinyl tape (wide)
Connecting cable
Pipe
3. Bundle the piping and drain hose together by
wrapping them with vinyl tape sufficient
enough to cover where they fit into the rear
piping housing section.
Vinyl tape(narrow)
Wrap with vinyl tape
Pipe
Vinyl tape(wide)
Drain hose
12 Multi Type Air Conditioner
Installation
For left rear piping
1
2
Connecting
cable
2. Insert the piping, drain hose, and the
connecting cable into the piping hole.
3. Insert the connecting cable into the indoor unit.
• Don't connect the cable to the indoor unit.
• Make a small loop with the cable for easy
connection later.
Drain pipe
4. Tape the drain hose and the connecting
cables.
5. Indoor unit installation
• Hang the indoor unit from the hooks at the
top of the installation plate.
• Insert the spacer etc. between the indoor
unit and the installation plate and separate
the bottom of the indoor unit from the wall.
Indoor unit
Spacer
Installation plate
8cm
Connecting the piping to the indoor unit and
the drain hose to drain pipe.
1. Align the center of the pipes and sufficiently
tighten the flare nut by hand.
Indoor unit tubing
Flare nut
Pipes
2. Tighten the flare nut with a wrench.
Outside diameter
mm
inch
Ø6.35
1/4
Ø9.52
3/8
Ø12.7
1/2
Ø15.88
5/8
Torque
kgf.m
1.8~2.5
3.4~4.2
5.5~6.6
6.3~8.2
3. When extending the drain hose at the indoor
unit, install the drain pipe.
Open-end wrench (fixed)
Flare nut
Wrench
Connection pipe
Indoor unit tubing
Drain hose
Indoor unit drain hose
Adhesive
Vinyl tape (narrow)
Installation Manual 13
ENGLISH
1. Route the indoor tubing and the drain hose to
the required piping hole position.
Installation
Wrap the insulation material around the
connecting portion.
1. Overlap the connection pipe heat insulation
and the indoor unit pipe heat insulation
material. Bind them together with vinyl tape
so that there may be no gap.
2. Wrap the area which accommodates the rear
piping housing section with vinyl tape.
Plastic bands Insulation material
Indoor
unit piping
Connection
pipe
Vinyl tape
(wide)
Wrap with vinyl tape
Pipe
Vinyl tape(narrow)
Connecting cable
3. Bundle the piping and drain hose together by
wrapping them with cloth tape over the range
within which they fit into the rear piping
housing section.
Pipe
Drain hose
Vinyl tape(narrow)
Wrap with
vinyl tape(wide)
Reroute the pipings and the drain hose
across the back of the chassis.
Piping for
passage through
piping hole
Indoor unit installation
1. Remove the spacer.
2. Ensure that the hooks are properly seated on
the installation plate by moving it left and
right.
3. Press the lower left and right sides of the unit
against the installation plate until the hooks
engage into their slots(clicking sound).
14 Multi Type Air Conditioner
Connecting
Drain hose
Installation
Installation Information. For left piping. Follow the instruction below.
• Press on the upper side of clamp and unfold the tubing to downward slowly.
Bad case
• Following bending type from right to left may cause damage to the tubing.
Installation Manual 15
ENGLISH
Good case
Installation
Connecting the Cables
Indoor
Connect the cable to the indoor unit by connecting the wires to the terminals on the control board
individually according to the outdoor unit connection. (Ensure that the color of the wires of the
outdoor unit and the terminal No. are the same as those of the indoor unit.)
How to use the front panel
1. Front panel opening
Hold the two ends of the front panel at the
bottom and move it upward.
Front panel
2. Front panel closing
Move the link upward and close the front
panel.
3. Front panel removing
Raise the link up to hook hanger and remove front panel forward.
16 Multi Type Air Conditioner
Installation
Checking the Drainage
1. Pour a glass of water on the evaporator.
Connecting area
drain hose
2. Ensure the water flows through the drain
hose of the indoor unit without any leakage
and goes out the drain exit.
Leakage
checking
Drain pan
Drain
hose
Leakage
checking
Drain piping
1. The drain hose should point downward for
easy drain flow.
Downward slope
2. Do not make drain piping like the following.
Accumulated
drain water
Air
Do not raise
Water
leakage
Water
leakage
Waving
Tip of drain hose
dipped in water
Water
leakage
Less than
50mm gap
Ditch
Installation Manual 17
ENGLISH
To check the drainage.
Installation
Test Run
1. Check that all tubing and wiring are properly connected.
2. Check that the gas and liquid side service valves are fully open.
Prepare remote controller
1. Remove the battery cover by pulling it
according to the arrow direction.
2. Insert new batteries making sure that the (+)
and (–) of battery are installed correctly.
3. Reattach the cover by pushing it back into
position.
NOTICE
• Use 2 AAA(1.5volt) batteries. Do not use
rechargeable batteries.
• Remove the batteries from the remote controller
if the system is not used for a long time.