MODELS: BR/BG/BH Series Type: Ceiling Concealed Duct - High Static ESPAÑOL INSTALLATION MANUAL ITALIANO System Heat Pump Indoor Unit ENGLISH LG FRANÇAIS DEUTSCH IMPORTANT • Please read this installation manual completely before installing the product. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. • Please retain this installation manual for future reference after reading it thoroughly. Ceiling Concealed Duct - High Static Type Indoor Unit Installation Manual TABLE OF CONTENTS Installation Requirements Required Parts Required Tools Features ...................................3 Safety Precautions .................4 Installation ❏ Four type "A" screws ❏ Connecting cable Selection the best location ....7 Ceiling opening dimension and hanging bolt location ......8 Indoor Unit Installation...........9 ❏ Flaring tool set ❏ Specified torque wrenches (different depending on model No.) ❏ Spanner .......Half union Wiring Connection .................9 ❏ A glass of water ❏ Screw driver Checking the Drainage........10 ❏ Hexagonal wrench ❏ Gas-leak detector ❏ Vacuum pump ❏ Gauge manifold Installation of Remote controller.....................................13 Two Thermistor system.......14 How to Set E.S.P? ................15 2 ❏ Pipes: Gas side Liquid side (Refer to Product Data) ❏ Insulation materials ❏ Additional drain pipe ❏ Level gauge ❏ Screw driver ❏ Electric drill ❏ Hole core drill Indoor Unit ❏ Owner's manual ❏ Thermometer Feature ENGLISH Features Air outlet vents Air filters Air intake vents Remote Controller Installation Manual 3 Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Be sure to read before installing the air conditioner. ■ Be sure to observe the cautions specified here as they include important items related to safety. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only. ■ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. ■ Installation Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit. For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Always ground the product. • There is risk of fire or electric shock. • Do not disassemble or repair the product. There is risk of fire or electric shock. • There is risk of fire or electric shock. Install the panel and the cover of control box securely. Always install a dedicated circuit and breaker. Use the correctly rated breaker or fuse. • There is risk of fire or electric shock. • Improper wiring or installation may cause fire or electric shock. • There is risk of fire or electric shock. 4 Indoor Unit Safety Precautions Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. Be cautious when unpacking and installing the product. • There is risk of fire or electric shock. • Moisture may condense and wet or damage furniture. • Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator. For installation, always contact the dealer or an Authorized Service Center. Do not install the product on a defective installation stand. Be sure the installation area does not deteriorate with age. • There is risk of fire, electric shock, explosion, or injury. • It may cause injury, accident, or damage to the product. • If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury. ■ Operation Do not store or use flammable gas or combustibles near the product. • There is risk of fire or failure of product. Gasolin Installation Manual 5 ENGLISH Do not modify or extend the power cable. Safety Precautions ■ Installation Always check for gas (refrigerant) leakage after installation or repair of product. Install the drain hose to ensure that water is drained away properly. Keep level even when installing the product. • Low refrigerant levels may cause failure of product. • A bad connection may cause water leakage. • To avoid vibration or water leakage. 90˚ Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. Use two or more people to lift and transport the product. Do not install the product where it will be exposed to sea wind (salt spray) directly. • It may cause a problem for your neighbors. • Avoid personal injury. • It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation. 6 Indoor Unit Installation Installation ENGLISH Read completely, then follow step by step. Selection of the best location Install the air conditioner in the location that satisfies the following conditions. • The place shall easily bear a load exceeding four times the indoor unit’s weight. • The place shall be able to inspect the unit as the figure. • The place where the unit shall be leveled. • The place shall allow easy water drainage.(Suitable dimension “H” is necessary to get a slope to drain as figure.) • The place shall easily connect with the outdoor unit. • The place where the unit is not affected by an electrical noise. • The place where air circulation in the room will be good . • There should not be any heat source or steam near the unit. Top view (unit: mm) Inspection hole (600X600) 600 1000 Control box 600 Front Front view H CAUTION : In case that the unit is installed near the sea, the installation parts may be corroded by salt, The installation parts (and the unit) should be taken appropriate anti-corrosion measures. Installation Manual 7 Installation Ceiling dimension and hanging bolt location ■ Installation of Unit Install the unit above the ceiling correctly. A B CASE 1 POSITION OF SUSPENSION BOLT C E • Apply a joint-canvas between the unit and duct to absorb unnecessary vibration. Capacity (kBtu/h) (G) B C 932 882 D E F (G) H 355 45.5 450 30 87 750 28/36/42k 1232 1182 355 45.5 450 30 87 830 48k 1287 1230 477 30 120 1004 I 18/24k A F D (Unit:mm) Dimension 57 590 H CASE 2 Drainage hole • Install the unit leaning to a drainage hole side as a figure for easy water drainage. POSITION OF CONSOLE BOLT • A place where the unit will be leveled and that can support the weight of the unit. • A place where the unit can withstand its vibration. • A place where service can be easily performed. M10 Nut X4 (Local M10 SP. washer X 4 supply) M10 washer X4 X4 (Local M10 SP. washer X 4 supply) M10 Nut X4 M10 washer NOTICE • Throughly study the following installation locations: 1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of the heat exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc. In these cases, take the following actions: • Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily steam which should not flow into the suction of the air conditioner. • Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam. 2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc. 3. Avoid places where inflammable gas is generated, flows in, is stored or vented. 4. Avoid places where sulfurous acid gas or corrosive gas is generated. 5. Avoid places near high frequency generators. 8 Indoor Unit Installation Indoor Unit Installation • Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling. • Mount the suspension bolts to the set anchor firmly. • Secure the installation plates onto the suspension bolts (adjust level roughly) using nuts, washers and spring washers. Old building New building 1 Set anchor 2 Plate washer 3 Spring washer 4 Nut CAUTION : Tighten the nut and bolt to prevent unit falling. 5 Suspension bolts Wiring Connection Connect the wires to the terminals on the control board individually according to the outdoor unit connection. • Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively. Indoor Outdoor unit unit Terminal Block Indoor 1(L) 2(N) 3 4 A B E F Central controller C Main outdoor unit D Vcc GND INDOOR POWER INPUT WARNING : Make sure that the screws of the terminal are free from looseness. Clamping of cables 1) Arrange 2 power cables on the control panel. 2) First, fasten the steel clamp with a screw to the inner boss of control panel. 3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the 0.75mm2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel. Installation Manual 9 ENGLISH • Select and mark the position for fixing bolts. • Drill the hole for set anchor on the face of ceiling. Installation INSULATION, OTHERS THERMAL INSULATION Insulate the joint and tubes completely. All thermal insulation must comply with local requirement. INDOOR UNIT Union for liquid pipe Refrigerant pipe and thermal insulator(Local supply) Hose crip for thermal insulator (Local supply) Thermal insulator for refrigerant pipe (Local supply) Union for gas pipe Checking the Drainage 1. Remove the Air Filter. 2. Check the drainage. • Spray one or two glasses of water upon the evaporator. • Ensure that water flows drain hose of indoor unit without any leakage. 10 Indoor Unit Thermal insulator for refrigerant pipe (Local supply) Thermal insulator for piping(Local supply) Overlap with thermal insulator for piping. Hose crip for thermal insulator(Local supply) Make sure that there is no clearance here. Installation CAUTION Front of view • The unit must be horizontal or declined to the drain hose connected when finished installation. 1~3mm Ceiling Drain Pump unuse Drainage hole CAUTION FOR GRADIENT OF UNIT AND DRAIN PIPING • Alway lay the drain with downward inclination (1/50 to 1/100). Prevent any upward flow or reverse flow in any part. • 5mm or thicker formed thermal insulator shall always be provided for the drain pipe. Drain Pump use Drainage hole Lay the drain hose with a downware inclination so water will drain out. Thermal insulator (Local supply) Drainage pipe (Local supply) Unit Make sure to be closed. Drainage hole • Upward routing not allowed INCORRECT Applied U-Trap Dimension CORRECT • Install the P-Trap (or U-Trap) to prevent a water leakage caused by the blocking of intake air filter. A ≥ 70mm B ≥ 2C C ≥ 2 x SP SP = External Pressure (mmAq) Ex) External Pressure = 10mmAq A ≥ 70mm B ≥ 40mm C ≥ 20mm B C U-Trap A Installation Manual 11 ENGLISH 1. Install declination of the indoor unit is very important for the drain of the duct type air conditioner. 2. Minimum thickness of the insulation for the connecting pipe shall be 5mm. Installation CAUTION: After the confirmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power specialized for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control box cover. 2) Provide a circuit breaker switch between power source and the unit. 3) The screws which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of the wires.) 4) Specification of power source 5) Confirm that electrical capacity is sufficient. 6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate. 7) Confirm that the cable thickness is as specified in the power sources specification. (Particularly note the relation between cable length and thickness.) 8) Never fail to equip a leakage breaker where it is wet or moist. 9) The following troubles would be caused by voltage drop-down. • Vibration of a magnetic switch, damage on the contact point, fuse breaking, disturbance by the normal function of an overload protection device. • Proper starting power is not given to the compressor. HAND OVER Teach the customer the operation and maintenance procedures, using the operation manual. (air filter cleaning, temperature control, etc.) 12 Indoor Unit Installation Installation of Remote Controller Installation of the remote controller • Select places that are not splashed with water. • Select controller position after receiving customer approval. • The room temperature sensor is built in the indoor unit. • This remote controller equipped with liquid crystal display. If this position is higher or lower, display is difficult to see.(The standard height is 1.2 ~1.5m high) Routing of the remote controller cord • Keep the remote controller cord away from the refrigerant piping and the drain piping. • To protect the remote controller cord from electrical noise, place the cord at least 5cm away from other power cables. (audio equipment. television set, etc.) • If the remote controller cord is secured to the wall, provide a trap at the top of the cord to prevent water droplets from running. WIRED REMOTE CONTROL INSTALLATION DISASSEMBLING • Separate the under plate from Remote controller box. Front case Th el ow er pa • Attach insulator to under plate. rt Lever carefully the box open using a screw driver, etc. Remote control box body • Fix the under plate on the wall • Fix the cord clamps on the wall by ø 3 tapping screws (accessory). • Fix the remote controller cord. Face of wall Cord clamp (accessory) Under plate Screw (accessory) Remote control ELECTRICAL WIRING (Main board) CN REMO Wire and make sure that teminal numbers are matched on unit side and remote control side. The maximum length of the cord is 100m. If the length of the cord exceeds 50m, 2 use a wire size greater than 0.5mm . Installation Manual 13 ENGLISH • Although the room temperature sensor is in the indoor unit, the remote controller should be installed in such places away from direct sunlight and high humidity. Two Thermistor system Two Thermistor system • Open the rear cover of Remote Controller to set up the mode. • Selectable options are three as follows. - Remo: Sensing the room Temperature. Slide Switch1 Room Temp. Sensing Remo. Indoor Unit 2 TH(Remo.+Indoor) - Indoor Unit: Sensing the intake air into indoor Unit. - 2 TH: Sensing the lower temperature of the two thermistors. • To set up the mode, adjust the slide switch to desired mode position on installing. 14 Indoor Unit Slide Switch2 Single Group CAUTION • On installing, don't impact to the PCB and LCD display. • Don't remove the protection sheet. • Use the specified screw. • On installing, turn off the main power. How to Set E.S.P? How to Set E.S.P? ENGLISH Procedure of RPM change: Ex) External Static pressure is 4mmAq for Model Name "ABNH12G1FAB/ABNH24G1FAB" • To protect the unit, compressor is designed to be off during E.S.P. setting. the "On/Off" button. 1 Push The unit will start. AUTO SWING OPERATION SET TEMP FAN SPEED Room Temp AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1 2 3 4 Time Timer Operation unit On Off Set no. Time 01 2 03 SUB FUNCTION HI MED LO Program set 05 07 09 11 13 15 17 19 21 23 Push the "Timer" and "Wind" button simultaneously for more then 3 seconds. Timer AUTO SWING OPERATION SET TEMP FAN SPEED Room Temp AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1 2 3 4 Time Timer Operation unit On Off Set no. Time 01 03 SUB FUNCTION HI MED LO Program set 05 07 09 11 13 15 17 19 21 23 the "Up" of "Down" button for E.S.P adjustment. 3 Push And, adjust the number which you want.(In this example, the number is "190". Refer to the table 1 on the next page.) AUTO SWING OPERATION SET TEMP Room Temp FAN SPEED AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1 2 3 4 Time Timer Operation unit On Off Set no. Time 01 NOTICE 03 SUB FUNCTION HI MED LO Program set 05 07 09 11 13 15 17 19 21 23 The range of selection is from 1~254. Since, the display is two Digit only. If the range selection is above 100 then the third digit will appear in the screen as shown. the fan speed mode by pressing the fan speed button. 4 Shift And then, Adjust numbers of next steps by repeating the stage 3. (In this example, the numbers are "220" and "235" respectly) 5 Push the "Timer" and "Wind" button simultaneously for more than 3 seconds. Then, Wind Data is memorized by the EEPROM of the main PCB. AUTO SWING OPERATION SET TEMP Room Temp AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1 2 3 4 Time Timer Operation unit 03 SUB FUNCTION HI MED LO Timer On Off Set no. Time 01 FAN SPEED Program set 05 07 09 11 13 15 17 19 21 23 Installation Manual 15 How to Set E.S.P? [Table.1] Static Pressure(mmAq) 2 3 Model Name Step(Hi/Med/Lo) 18k 21k 24k 28k 36k 38k 42k 48k NOTICE 16 6 8 10 14 Setting Value 15.3CMM 106 - 130 - - - 13.6CMM 100 - 125 - - - 10.3CMM 90 - 110 - - - 17.7CMM 115 - 140 - - - 14.5CMM 103 - 128 - - - 12.2CMM 95 - 120 - - - 19.0CMM 120 - 145 - - - 16.4CMM 110 - 135 - - - 14.5CMM 103 - 128 - - - 25.3CMM - 113 - 127 - - 21.8CMM - 105 - 120 - - 17.6CMM - 97 - 113 - - 29.6CMM - 120 - 140 - - 25.3CMM - 113 - 127 - - 21.8CMM - 105 - 120 - - 29.6CMM - 123 - 143 - - 26.3CMM - 115 - 131 - - 23.6CMM - 109 - 124 - - 32.0CMM - 130 - 148 - - 28.4CMM - 120 - 140 - - 23.6CMM - 115 - 132 - - 45CMM - - - - 112 122 40CMM - - - - 108 118 33MM - - - - 104 114 1. Be sure to set the value refering table 1. Unexpected set value will cause mal-function. 2. Table 1 is based at 220-240V. According to the fluctuation of voltage, air flow rate varies. Indoor Unit P/No.: 3828A20873B Printed in Korea After reading this manual, keep it in a place easily accessible to the user for future reference.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project