MPS Multi Air Conditioner Owner’s Manual
TABLE OF CONTENTS
Safety Precautions .........................3
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Prior to Operation ..........................8
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Introduction ....................................9
Date Purchased
Staple your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
Operating Instructions.................10
READ THIS MANUAL
Maintenance and Service ............24
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
• Contact the authorized service technician for
repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by
authorized personnel only using only genuine
replacement parts.
• Installation work must be performed in
accordance with the National Electric Code by
qualified and authorized personnel only.
2 MPS Multi Air Conditioner
Safety Precautions
Always install an air leakage
breaker and a dedicated
switching board.
• No installation may cause a fire
and electrical shock.
Do not keep or use
flammable gases or
combustibles near the air
conditioner.
• Otherwise, it may cause a fire
or the failure of product.
Ensure that an installation
frame of the outdoor unit is
not damaged due to use for
a long time.
• It may cause injury or an
accident.
x
Wa Thinner
Do not disassemble or
repair the product
randomly.
• It will cause a fire or electrical
shock.
Do not install the product at
a place that ther is concern
of falling down.
• Otherwise, it may result in
personal injury.
Use caution when
unpacking and installing.
• Sharp edges may cause injury.
@ Operation
Do not share the outlet with
other appliances.
Do not use the damaged
power cord.
• It will cause an electric shock or
a fire due to heat generation.
• Otherwise, it may cause a fire
or electrical shock.
Take care so that the power
cord may not be pulled
during operation.
Unplug the unit if strange
sounds, smell, or smoke
comes from it.
• Otherwise, it may cause a fire
or electrical shock.
4 MPS Multi Air Conditioner
• Otherwise, it may cause
electrical shock or a fire.
Do not modify or extend the
power cord randomly.
• Otherwise, it may cause a fire
or electrical shock.
Keep the flames away.
• Otherwise, it may cause a fire.
Safety Precautions
Take the power plug out if
necessary, holding the head
of the plug and do not touch
it with wet hands.
Do not use the power cord
near the heating tools.
• Otherwise, it may cause a fire
and electrical shock.
Do not allow water to run
into electrical parts.
Hold the plug by the head
when taking it out.
• Otherwise, it may cause the
failure of machine or electrical
shock.
• It may cause electric shock and
damage.
Ventilate the room well
when using this appliance
together with a stove, etc.
When cleaning the unit, first
make sure the power and
breaker are turned off.
• An oxygen shortage may occur.
• Otherwise, it may cause
electrical shock.
• Otherwise, it may electrical
shock and failure.
Never touch the metal parts
of the unit when removing
the filter.
• They are sharp and may cause
injury.
Turn off the main power
switch when not using the
product for a long time.
• Otherwise, it may cause the
failure of product or a fire.
Do not step on the indoor/outdoor unit and
do not put anything on it.
Do not place a heavy object on the power
cord.
• It may cause an injury through dropping of the unit
or falling down.
• Otherwise, it may cause a fire or electrical shock.
Owner's Manual 5
ENGLISH
• Otherwise, it may cause a fire
or electrical shock.
Do not open the suction
inlet of the indoor/outdoor
unit during operation.
Safety Precautions
When the product is submerged into water,
always contact the service center.
Take care so that children may not step on
the outdoor unit.
• Otherwise, it may cause a fire or electrical shock.
• Otherwise, children may be seriously injured due
to falling down.
@ Installation
Install the drain hose to ensure that drain
can be securely done.
• Otherwise, it may cause water leakage.
Always inspect gas leakage after the
installation and repair of product.
• Otherwise, it may cause the failure of product.
6 MPS Multi Air Conditioner
Install the product so that the noise or hot
wind from the outdoor unit may not cause
any damage to the neighbors.
• Otherwise, it may cause dispute with the
neighbors.
Keep level parallel in installing the product.
• Otherwise, it may cause vibration or water
leakage.
Safety Precautions
■ Operation
• Otherwise, it may do harm to
your health.
Use a soft cloth to clean. Do
not use wax, thinner, or a
strong detergent.
• The appearance of the air
conditioner may deteriorate,
change color, or develop
surface flaws.
When gas leaks, open the
window for ventilation
before operating the unit.
• Otherwise, it may cause
explosion, and a fire.
x
Wa Thinner
Do not use an appliance for
special purposes such as
preserving animals
vegetables, precision
machine, or art articles.
• Otherwise, it may damage your
properties.
Do not place obstacles
around the flow inlet or
outlet.
• Otherwise, it may cause the
failure of appliance or an
accident.
Do not insert the hands or bars through the
air inlet or outlet during operation.
• Otherwise, it may cause personal injury.
Always insert the filter
securely. Clean it every two
weeks.
• Operation without the filter will
cause failure.
Do not drink water coming out of the air
conditioner.
• Otherwise, it may cause stomachache.
Owner's Manual 7
ENGLISH
Avoid excessive cooling
and perform ventilation
sometimes.
Prior to Operation
Prior to Operation
Preparing for Operation
1. Contact an installation specialist for installation.
2. Plug in the power plug properly.
3. Use a dedicated circuit.
4. Do not use an extension cord.
5. Do not start/stop operation by plugging/unplugging the power cord.
6. If the cord/plug is damaged, replace it with only an authorized replacement part.
Usage
1. Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose
occupants, pets, or plants to direct airflow for a long time.
2. Due to the possibility of oxygen deficiency, ventilate the room when using the appliance together with
stoves or other heating devices.
3. Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices,
food, pets, plants, or art objects). Such use may damage your properties.
Cleaning and Maintenance
1. Do not touch the metal parts of the unit when removing the filter. Injury can occur.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a
very high speed during operation. There is a possibility of injury if the unit’s power is triggered while
cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
8 MPS Multi Air Conditioner
Air inlet
Air filter
Air inlet
Air filter
Air discharge
Air discharge
Front panel
Front panel
Signal receiver
ON/OFF button
Signal receiver
ON/OFF button
!IR )NTAKE 6ENTS
#ONNECTING
WIRING
0IPING
$RAIN (OSE
!IR /UTLET 6ENTS
"ASE 0LATE
10 MPS Multi Air Conditioner
Safety Precautions
Safety Precautions
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
@ The meanings of the symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
@ Installation
Always perform grounding.
• Otherwise, it may cause electrical shock.
For installation of the product, always
contact the service center or a professional
installation agency.
• Otherwise, it may cause a fire, electrical shock,
explosion or injury.
Don’t use a power cord, a plug or a loose
socket which is damaged.
• Otherwise, it may cause a fire or electrical shock.
Securely attach the electrical part cover to
the indoor unit and the service panel to the
outdoor unit.
• If the electrical part cover of the indoor unit and
the service panel of the outdoor unit are not
attached securely, it could result in a fire or
electric shock due to dust, water, etc.
Owner's Manual 3
%.' ,)3(
To prevent the injury of the user or other people and property damage, the following instructions must be
followed.
@ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified
by the following indications.
Operating Instructions
11
Operating Instructions
Cooling operation
1
Press the Start/Stop button.
The unit will respond with
a beep.
2
Open the door of the remote controller. To select Cooling
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
Cooling
3
ON
Auto
Healthy
Dehumidification
Heating
(Heat pump model only)
Close the door of the remote controller. Set the temperature
lower than the room temperature. The temperature can be
set within a range of 18°C~30°C at intervals of 1°C.
To raise the temperature
To lower the temperature
4
Set the fan speed again with the door
of the remote controller still closed.
You can select the fan speed in four
steps-low, medium, high and CHAOS.
Each time the button is pressed, the
fan speed mode is shifted.
Natural wind by the CHAOS logic
* For fresher feeling, press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind
blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
12 MPS Multi Air Conditioner
Operating Instructions
Auto operation (Cooling model only)
Press the Start/Stop button.
The unit will respond with
a beep.
2
Open the door of the remote controller. To select Auto
Operation, press the operation mode selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
Cooling
ON
ENGLISH
1
3
Auto
Healthy
Dehumidification
Heating
(Heat pump model only)
The temperature and fan speed are automatically set by the
electronic controls based on the actual room temperature. If
you want to change the set temperature, press the Room
Temperature Setting buttons. The cooler or warmer you feel,
the more times (up to two times) you should press the button.
The set temperature will be changed automatically.
To raise the temperature
To lower the temperature
During Auto Operation
You cannot control the indoor fan speed. It has already been set by the Fuzzy rule.
If the system is not operating as desired, manually switch to another mode. The system will not
automatically switch from the cooling mode to the heating mode, or from heating mode to cooling
mode, it must be done by manually resetting.
During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and
down automatically. If you want to stop auto-swing, press the chaos swing button again.
Owner's Manual 13
Operating Instructions
Auto changeover operation(Heat pump model only)
1
Press the Start/Stop button.
The unit will respond with
a beep.
2
Open the door of the remote controller. To select Auto Changeover
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is shifted in the
direction of the arrow.
Cooling
3
Auto
changeover
Healthy
Dehumidification
Heating
(Heat pump model only)
Close the door of the remote controller. Set the temperature
lower than the room temperature. The temperature can be
set within a range of 18°C~30°C at intervals of 1°C.
To raise the temperature
ON
To lower the temperature
4
Set the fan speed again with the door
of the remote controller still closed.
You can select the fan speed in four
steps-low, medium, high and CHAOS.
Each time the button is pressed, the
fan speed mode is shifted.
During Auto changeover Operation
The air conditioner changes the operation mode automatically to keep indoor temperature. When room
temperature vary over ±2°C with respect to setting temperature, air conditioner keeps the room
temperature within ±2°C with respect to setting temperature by auto changeover mode.
14 MPS Multi Air Conditioner
Operating Instructions
Healthy dehumidification operation
Press the Start/Stop button.
The unit will respond with
a beep.
2
Open the door of the remote controller. To select Healthy
Dehumidification Operation, press the Operation Mode
Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
Cooling
3
ON
ENGLISH
1
Auto
Healthy
Heating
Dehumidification (Heat pump model only)
Set the fan speed again with the door
of the remote controller still closed.
You can select the fan speed in four
steps-low, medium, high, or CHAOS.
Each time the button is pressed, the
fan speed mode is shifted.
Natural wind by the CHAOS logic
For fresher feeling, press the Indoor Fan Speed Selector and set
to CHAOS mode. In this mode, the wind blows like a natural
breeze by automatically changing fan speed according to the
CHAOS logic.
During Healthy Dehumidification Operation
If you select the dehumidification mode on the operation selection button, the A/C starts to run the
dehumidification function. It automatically sets the room temp. and airflow volume to the best condition
for dehumidification, based on the sensed current room temp.
In this case, however, the setting temp. is not displayed on the remote controller and you are not able to
control the room temp. either.
During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status, so that the room condition is kept
healthy and comfortable even in the very humid season.
Owner's Manual 15
Operating Instructions
Heating operation (Heat pump model only)
1
Press the Start/Stop button.
The unit will respond with
a beep.
2
Open the door of the remote controller. To select Heating
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
Cooling
3
ON
Auto
Healthy
Heating
Dehumidification (Heat pump model only)
Close the door of the remote controller.
Set the temperature higher than the room temperature.
The temperature can be set within a range of 16°C~30°C at
intervals of 1°C.
To raise the temperature
To lower the temperature
4
Set the fan speed again with the door of the
remote controller still closed. You can
select the fan speed in four steps–low,
medium, high and CHAOS. Each time the
button is pressed, the fan speed mode is
shifted.
Natural wind by the CHAOS logic
? For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the
wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
16 MPS Multi Air Conditioner
Operating Instructions
Jet cool operation
ENGLISH
1
Press the Start/Stop button.
The unit will respond with
a beep.
2
Press the Jet Cool button to operate
the speed cooling mode and the unit
will operate at super high fan speed
on cooling mode for 30 minutes.
3
To cancel the Jet Cool mode, press the Jet Cool button, the
fan speed button or the room temperature setting button
again and the unit will operate at high fan speed on cooling
mode.
or
or
NOTICE
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely
high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to
cool the room temp. quickly in a hot summer.
In heat pump mode or neuro fuzzy mode, however, the JET COOL function is not available.
In order to return to the normal cooling mode from the JET COOL mode, just press the operation
mode selection button, airflow volume selection, temp. setting button or the JET COOL button
again.
Owner's Manual 17
Operating Instructions
NEO PLASMA purification operation(Optional)
1
Press the Start/Stop button.
The unit will respond with a
beep.
2
Open the door of the remote
controller. Press the NEO PLASMA
button.
Operation will start when the button
is pressed and stop when the button
is pressed again.
3
Set the fan speed again with the door of the remote
controller closed. You can select the fan speed in four
steps-low, medium, high or CHAOS.
Each time the button is pressed, the fan
speed mode is shifted.
? Air purifying operation (NEO PLASMA) can be
with cooling, Heating or any other operations.
NEO PLASMA Air Purifying Operation only
If you press the only NEO PLASMA button,
only NEO PLASMA purification function
operates.
Then, fan speed is low. You can select the fan
speed in four steps-low, medium, high or
CHAOS.
Each time the button (
) is pressed, the fan
speed mode is shifted.
18 MPS Multi Air Conditioner
Operating Instructions
2nd F operation
ENGLISH
1
Press the Start/Stop button.
The unit will respond with
a beep.
2
Open the door of the remote control and press the 2nd
Function button to operate functions printed in blue unter
buttons.
(Check the indication of 2nd function on the display of the
remote controller.)
These buttons can set the timer as follows:
ON
OFF
SET
CANCEL
ON
OFF
SET
AUTO CLEAN
3
2nd function disappears in a short time automatically or when
the button is pressed again.
For more details, refer to functions next pages.
Owner's Manual 19
Operating Instructions
Additional Features
Sleep mode
1. Press the Sleep Mode Auto button to set the time you want the unit to stop automatically.
2. The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The
sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode
Button while aiming at air conditioner.
3. Make sure the Sleep Mode Auto LED lights up.
To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star
(
) disappears from the operation display.
NOTICE
The Sleep Mode will be operated at slow fan speed (cooling) or medium fan speed (heat pump
only) for a comfortable sleep.
In cooling mode or healthy dehumidification mode:
The temperature will automatically rise by 1°C over the next 30 minutes and by 2°C in 1 hour for a comfortable
sleep.
Setting the time
1. Time can be set only when you press the Reset button. Having replacing the batteries,
you should press the reset buttons to reset the time. Press the Start/Stop button.
2. Press 2nd F button and check if 2nd F icon is on.
3. Press the Time Setting buttons until the desired time is set.
CANCEL
4. Press the Timer SET button.
SET
NOTICE
Check the indicator for A.M. and P.M.
Delay start/Pre-set stop
1. Make sure the time is set correctly on the display of the remote controller.
2. Press 2nd F button.
3. Press the ON/OFF Timer buttons to turn Timer on or off.
ON
OFF
4. Press the Time Setting buttons until the desired time is set.
CANCEL
5. To set the selected time, press the Timer setting button aiming the remote controller at the
signal receptor.
To cancel the timer setting
Check if 2nd F icon is off.
Press the Timer Cancel button aiming the remote controller at the signal receptor.
(The timer lamp on the air conditioner and the display will go out.)
NOTICE
Select one of the following four types of operation.
Delay OFF Timer
Delay ON Timer
20 MPS Multi Air Conditioner
SET
CANCEL
SET
with the unit running
Delay OFF and ON Timer Delay ON and OFF Timer
Operating Instructions
Vertical Airflow Direction Control
1. Press the Start/Stop button to start the unit.
2. Press Chaos Swing button and the louvers will
swing up and down. Press the Chaos Swing
button again to set the vertical louver at the
desired airflow direction.
NOTICE
If you press the CHAOS swing button, the
horizontal airflow direction is changed
automatically based on the CHAOS algorithm to
distribute the air in the room evenly and at the
same time to make the human body feel most
comfortable, as if enjoying a natural breeze.
Always use the remote control to adjust the
up/down airflow direction. Manually moving the
vertical airflow direction louver by hand, could
damage the air conditioner.
When the unit is shut off, the up/down airflow
direction louver will close the air outlet vent of the
system.
Horizontal Airflow Direction Control (Optional)
The left/right(Horizontal Airflow) can be adjusted by using the remote control.
Press the Start/Stop button to start the unit.
Open the door on the remote control. Press the Airflow Direction Start/Stop
button and the louvers will swing left and right. Press the Horizontal Airflow
Direction Control Button again to set the horizontal louver at the desired airflow
direction.
Air circulation mode
Circulates the room air without cooling or heating.
1. Press the Start/Stop button. the unit will respond with a beep.
2. Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control.
Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS
and back to low again.
CHAOS Air
NOTICE
Fan speed is on low.
Fan speed is on medium.
Fan speed is on high.
CHAOS Air economizes power consumption and prevents overcooling. The fan speed is
automatically changed from high to low or vice versa, depending on the ambient temperature.
Owner's Manual 21
ENGLISH
The up/down airflow (Vertical Airflow) can be
adjusted by using the remote control.
Operating Instructions
Auto clean (Optional)
AUTO CLEAN
1. Whenever you press the Auto Clean button, Auto Clean Function will be
reserved and cancelled.
2. Auto Clean function works before and after cooling or dehumidification mode.
For details, refer to the below points.
3. When the unit is started after the reservation of Auto Clean ,the Cool Start
function operates and indoor Fan is started after 20 seconds.
4. When you press Start/Stop button to turn off the unit after the you have reserved
Auto Clean function, the air-conditioner circulates the indoor air in the Auto
Clean mode with no more Cooling or Dehumidification operation. For Cooling
only model, it lasts for 30 minutes for Heat pump model, for 16 minutes.
5. If you press the auto clean button again during the product operation , Auto
Clean function will be cancelled.
NOTICE
? During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy
Dehumidification Operation can be removed.
? During Auto Clean function, only Start/Stop button, Plasma button and Auto Clean button are available.
Display Luminosity (Optional)
• The Display Luminosity can be adjusted by using the remote control.
Press the start/stop button to start the unit. Open the door on the remote control, press the 2ndF button
and, press display luminosity button. Display will be dark. Press the button again to set bright display.
22 MPS Multi Air Conditioner
Operating Instructions
Forced operation
% . ' ,) 3 (
Operation procedures when the remote control can't be used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.
Power
button
Cooling Model
Operating mode
Cooling
Indoor FAN Speed
Setting Temperature
High
22°C
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed for
about 3 seconds.
If you want to stop the operation, re-press the button.
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the value
when the fan speed is set to high, and the capacity will be lower
at low or medium fan speed.
High fan speed is recommended when you wish to cool the room
quickly.
(IGH
3PEED
Owner's Manual 23
Maintenance and Service
Maintenance and Service
Indoor Unit
WARNING: Turn the system off before cleaning.
To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
NOTICE
Supply power must be disconnected before cleaning the indoor unit.
1. Open the upside of Front Panel
Front panel
2. Put up the Front panel.
The hook of panel comes off.
3. Come down the panel and then remove the air filter.
4. Clean it with a soft brush and the vacuum cleaner.
If it is very dirty, wash it with water.
5. Reinstall the air filter dried at the shade and then close
the panel.
Air filters
Never use any of the followings:
• Water hotter than 40°C
Could cause deformation and/or discoloration.
• Volatile substances
Could damage the surfaces of the air conditioner.
24 MPS Multi Air Conditioner
P owd
er
G asoli ne
2EAR
!IR )NTAKE 3IDE
6ENTS
2EAR
0IPING
$RAIN (OSE
!IR )NTAKE
6ENTS
!IR /UTLET
6ENTS
3IDE
0IPING
$RAIN (OSE
!IR /UTLET
6ENTS
Front panel
Maintenance and Service
Common Problems and Solutions
Before calling for service
If you have problems with your air conditioner, read the following information and try to solve
the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer.
Air conditioner does not operate
1. Ensure that the air conditioner is plugged into a proper outlet.
2. Check the fuse or circuit breaker.
3. Check whether the voltage is unusually high or low.
Air does not feel cold enough on the cooling setting
1. Ensure that the temperature settings are correct.
2. Check to see if the air filter is clogged with dust. If so, replace the filter.
3. Ensure that the air flow from the outside is not obstructed and that there is a clearance of
over 20" between the back of the air conditioner and the wall or fence behind it.
4. Close all doors and windows and check for any source of heat in the room.
Before calling for service, please review the following list of common problems and
solutions.
The air conditioner is operating normally when:
• You hear a pinging noise. This is caused by water being picked up by the fan on rainy days
or in highly humid conditions. This feature is designed to help remove moisture in the air
and improve cooling efficiency.
• You hear the thermostat click. This is caused by the compressor cycle starting and
stopping.
• You see water dripping from the rear of the unit. Water may be collected in the base pan in
highly humid conditions or on rainy days. This water overflows and drips from the rear of
the unit.
• You hear the fan running while the compressor is silent. This is a normal operational
feature.
26 MPS Multi Air Conditioner
Maintenance and Service
Troubleshooting
The air conditioner may be operating abnormally when:
Air
conditioner
does not start
Air
conditioner
does not cool
as it should
Air
conditioner
freezing up
Possible Causes
What To Do
The air conditioner is
unplugged.
• Make sure the air conditioner plug is
pushed completely into the outlet.
The fuse is blown/circuit
breaker is tripped.
• Check the house fuse/circuit breaker
box and replace the fuse or reset the
breaker.
Power failure.
• If power failure occurs, turn the mode
control to Off.
When power is restored, wait 3
minutes to restart the air conditioner
to prevent tripping of the compressor
overload.
Airflow is restricted.
• Make sure there are no curtains,
blinds, or furniture blocking the front of
the air conditioner.
The thermostat may not be
set high enough.
• Turn the knob to a higher number.
The highest setting provides
maximum cooling.
The air filter is dirty.
• Clean the filter at least every 2 weeks.
See the care and Maintenance
section.
The room may have been
hot.
• When the air conditioner is first turned
on, you need to allow time for the
room to cool down.
Cold air is escaping.
• Check for open furnace floor registers
and cold air returns.
Cooling coils have iced up.
• See Air Conditioner Freezing Up
below.
Ice blocks the air flow and
stops the air conditioner from
cooling the room.
• Set the mode control at High Fan or
High Cool with thermostat at 1 or 2.
* You can refer to the Energy Star program in detail at www.energystar.gov.
Owner's Manual 27
ENGLISH
Problem

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement