1
Important
Electromagnetic Fields (EMF)
3
5
2 Introduction
Overview
Control panel
5
6
7
3 Cleaning and sterilising
8
4 Assembling the electric
breast pump
9
5 Using the electric breast pump 11
Before using the pump
11
To begin pumping
11
To pause pumping
14
Storing your breast milk
15
Feeding your baby with
expressed breast milk
16
Keeping your electric breast
pump sterile for travel
16
6 Using the manual breast
pump when needed
17
Assembling the manual
breast pump
17
Using the manual breast pump 18
7 Hints to help you succeed
2
English
19
8 When to express milk
Right times of the day to
express your milk
20
9 Storage
20
20
10 Compatibility
21
11 Ordering accessories
21
12 Recycling
22
13 Guarantee and service
22
14 Troubleshooting
23
1 Important
Read this user manual carefully
before using your Philips Avent
single electric breast pump, and
save the user manual for future
reference. You can also find this
user manual at Philips website:
www.philips.com/support.
Warning
• Always unplug from the power
socket immediately after use.
• Do not use the breast pump
while bathing.
• Do not place or store the breast
pump where it can fall or be
pulled into a bath or sink.
• Do not place or drop the pump
motor, silicone tube, and power
adapter into water or other
liquids.
• Do not reach for a product
that has fallen into water.
Unplug from the power socket
immediately.
• Children should be supervised
to ensure that they do not play
with the appliance. Place the
appliance where children or
pets is not reachable.
• Before each use, check the
breast pump, including the
power adapter for signs of
damage. Never operate the
breast pump if it has a damaged
plug, not working properly, has
been dropped or damaged, or
has been submerged in water.
• The power cord is irreplaceable.
Discard it if is damaged,
including the power adapter.
• Only use accessories
recommended by Philips Avent.
• Only use the power adapter
supplied with the product.
• Make sure the breast pump,
including the power adapter, is
not exposed to extreme heat or
placed in direct sunlight.
• Do not use the breast pump
outdoors.
• There are no user serviceable
parts inside the pump. Do not
attempt to open, service, or
repair the breast pump yourself.
• The parts of the pump which
come directly into contact with
milk are personal care items,
and should not be shared
between mothers.
• Do not attempt to remove the
pump body from the breast
while under vacuum. Switch
the breast pump off, and break
the seal between your breast
and the pump funnel with your
finger, then remove the pump
from your breast. You can also
pull off the silicone tube from
the motor or the cap to release
the vacuum.
• Never use while pregnant as
pumping can induce labor.
• Never use when sleepy or
drowsy.
• This appliances can be used by
persons with reduced physical,
sensory or mental capabilities
or lack of experience and
knowledge if they have
English
3
•
•
•
•
•
been given supervision or
instruction concerning use of
the appliance in a safe way and
if they understand the hazards
involved.
This appliance shall not be used
by children.
If expressing becomes
painful, stop and consult
your breastfeeding advisor or
healthcare professional.
Do not use the breast pump
in the presence of flammable
anaesthetic mixtures with air,
with oxygen, or with nitrous
oxide.
Although the breast pump
is compliant with applicable
EMC directives, it may still
be susceptible to excessive
emissions and/or may interfere
with more sensitive equipment.
Make sure not put any products
on the pump motor, like pillow,
blanket etc. Please make
sure pump motor work in well
ventilation and heat dissipation
condition.
Caution
• The product should not be left
unattended when plugged into
a power socket.
• Never drop or insert any foreign
object into any opening or the
silicone tube.
• Do not shorten the silicone
tube.
• Before you connect the breast
pump to the power, make sure
that the voltage of the product
corresponds to the local power
voltage.
4
English
• Wash, rinse, and sterilise the
appropriate pump parts before
each use.
• Do not use antibacterial,
abrasive cleaners, or detergents
when cleaning breast pump
parts.
• Never put the breast pump
motor in water or steriliser,
as you can cause permanent
damage to the pump.
• If the vacuum generated is
uncomfortable or cause pain,
switch off the breast pump,
break the seal between the
breast and the pump funnel
with your finger, and then
remove the pump from your
breast. You can also pull off the
silicone tube from the motor or
the cap to release the vacuum.
• Do not continue pumping for
more than five minutes at a time
if no result is achieved.
• Never use any accessories or
parts from other manufacturers
or that Philips Avent does not
specifically recommend. If
you use such accessories or
parts, your guarantee becomes
invalid.
• Do not use the breast pump if
the silicone diaphragm appears
to be damaged or broken.
Replace the silicone diaphragm.
See chapter “Guarantee and
service” for information on how
to obtain replacement parts.
• Never use feeding teats as
dummies, pacifiers, or soothers.
Make sure that the teething
baby does not bite the teat
too long. The continuous and
prolonged bite will damage
the teat. For hygiene reasons,
replace teats after three months
of use. Use only Philips Avent
teats and bottles together.
Batteries
This appliance can use both 1.5V
AA non-chargeable batteries and
rechargeable batteries.
For instructions on how to
replace the batteries, see chapter
“Assemble”.
• Rechargeable batteries are to
be removed from the appliance
before being charged.
• Different types of batteries or
new and used batteries are not
to be mixed.
• Batteries are to be inserted
with the correct polarity.
• Exhausted batteries are to be
removed from the appliance
and safely disposed of.
• If the appliance is to be stored
unused for a long period, the
batteries should be removed.
• The supply terminals are not to
be short-circuited.
Electromagnetic Fields
(EMF)
This Philips appliance complies
with all applicable standards and
regulations regarding exposure to
electromagnetic fields.
2 Introduction
Congratulations on your
purchase and welcome to Philips
Avent! To fully benefit from
the support that Philips Avent
offers, register your product at
www.philips.com/ welcome.
The Philips Avent breast pump
provides comfort, convenience for
effective expression. Rhythmic Wave
mimics the fast/shallow & slow/
deep way a baby suckles for faster
let down and continuous milk flow
with closer to natural sucking pacing.
It also has a soft massage cushion,
an intuitive design to make whole
expression more comfortable and
convenient. This breast pump has a
handle, and you can easily switch
from single EBP to manual usage
Doctors recommend that breast
milk is the best nutrition for babies
during the first year, combined with
solid food after the first six months,
Your milk is specially adapted to
your baby’s needs and contains
antibodies which help protect your
baby against infection and allergies.
Your single electric breast pump will
help you breast-feed longer. You
can express and store your milk so
that - whether you are out for a few
hours, taking a well deserved rest,
or back at work - your baby can still
enjoy the benefits of your breast
milk, even if you cannot be there to
give it yourself. As the pump is easy
to assemble, silent and discreet,
you can take it with you anywhere,
allowing you to express milk at your
own convenience and maintain
your milk supply.
English
5
Overview
f e
d c b
a
v
u
t
s
r
g
h
i
j
k
l
m
n
a Silicone tube
b Cap
c Silicone diaphragm (x2)
(one for back up)
d Pump body
e Massage Cushion
f Pump cover
g Valve (x2) (one for back up)
h Dormal cap
i Screw ring
j Teat (0m+)
k Sealing disc
6
English
p
o
q
l Breast pad
m Bottle (125ml)
n Travel cover
o
p
q
r
s
t
u
v
Pump motor
Sling
Travel bag
Power adapter
Stem
Manual silicone diaphragm
Handle
Manual breast pump upper cover
Control panel
s

t
u
v
~
}
|
w
{
x
z
y
s Timer counting indicator
z Level up button
t Stimulation indicator
{ Pause/play button
u Level 2 indicator
| Level 4 indicator
v Level 1 indicator
} Level 3 indicator
w Mode selection button (selecting ~ Expression indicator
the stimulation and expression
mode)
x Level down button
 Battery indicator
y Power button
Note
•• The battery indicator flashes only when in low battery. We recomend you
to change the battery as soon as possible.
English
7
3 Cleaning and
sterilising
Before you use your breast pump
for the first time and for every time,
you must disassemble, wash, and
sterilise all the breast pump parts
that come into contact with your
breast milk. (see c, d, e, f, g,
m, s, t in Overview chapter)
Before you use the bottle and its
parts for the first time and for every
time,you must also disassemble,
wash and sterilise. (see h, i, j,
k in Overview chapter)
Caution
•• Never wash or sterilise the pump
motor, the silicone tube, the cap,
and the power adapter. These
components do not come into
contact with your breast milk.
You can wipe those parts clean
with a soft cloth.
You can also use the dishwasher
(top rack only) or hand wash in
warm, soapy water, and then rinse
thoroughly. We recommend you
to sterilise all the parts contacting
with breast milk in our Philips Avent
steam steriliser, or by boiling for
5 minutes.
8
English
Caution
•• Take care when cleaning
the valve and the silicone
diaphragm. If it gets damaged,
your breast pump will not
function properly.
•• To clean the valve, rub it gently
between your fingers in warm
soapy water. Do not insert
objects as this may cause
damage.
4 Assembling the
electric breast
pump
2
Put the bottle onto the pump
body and turn it anticlockwise
to fix it. Do not over-tighten
when assembling the bottle to
the pump body.
3
Insert the Massage Cushion
into the pump funnel and press
the rim to ensure a perfect seal.
4
Put the silicone diaphragm onto
the pump body and press the
rim to make sure a perfect seal.
To assemble the pump, follow the
steps below.
Note
•• Make sure that you clean and
sterilise the pump as instructed
in this user manual.
•• Make sure that you assemble
the pump correctly as instructed
in this user manual.
•• To avoid leakage, remove the
residue around the rim before
assembling. Put the bottle onto
the pump body, and do not
over-tighten.
•• Wash your hand thoroughly
before you take sterilised
components.
1
Insert the valve into the pump
body from underneath.
Tip
•• You may find it easier to
assemble while it is wet.
English
9
5
Firmly push the cap onto the
silicone diaphragm, so that it
sites securely on top of the
silicone diaphragm.
6
Connect the silicone tube to the
cap and the motor firmly.
7
Connect the power adapter
to the pump motor, and then
insert the power plug to the
power socket.
Note
•• Only use the adapter provided
with this product. Do not use
other adapter.
10
English
Tip
•• For battery operation, open
the rear cover of the motor unit
in the direction indicated by
the marks. Insert four new 1.5V
AA alkaline batteries into the
battery housing.Reattach the
rear cover to the motor unit.
We recommend you to use
rechargeable batteries for long
time use.
Note
•• If you have inserted batteries in
the battery housing of the pump
motor and plug in the adapter,
the breast pump will run from
the main power supply. The
batteries cannot be charged in
the unit.
5 Using the
electric breast
pump
To begin pumping
1
Press the assembled pump
bodies against your breasts.
Make sure that your nipples are
centered, so that the massage
cushion creates an airtight seal.
Make sure that no air escapes;
otherwise there is no suction.
2
Press the power button (
switch on your pump.
Before using the pump
•• Wash your hands thoroughly, and
make sure your breasts are clean.
Gently squeeze a little milk from
each nipple to make sure that milk
ducts are not blocked.
•• Make sure you follow the steps
in “Cleaning and sterilising” and
“Assembling” chapters to clean,
sterilise, and assemble the breast
pump.
•• Relax in a comfortable chair,
leaning slightly forward (use
cushions to support your back).
Make sure that you have a glass
of water nearby.
) to
»»The display panel lights up
for 1 second. The breast
pump automatically starts up
in stimulation level 1 mode
in the first time usage, and
the stimulation indicator
lights up. The appliance
has the memory function
to remember the levels for
your both stimulation and
expression in your latest
usage.
»»You begin to feel the suction
on your breast.
English
11
Note
4
Once your milk starts flowing,
you can press the mode
selection button ( ) to switch
to the expression mode.
5
After switching to the
expression mode, you can
choose your desired expression
level by pressing the level up
( ) and level down ( )
buttons. You can press the
level up button to deeper
the suction. Press the level
down button to lower the
suction.There are altogether
4 expression levels.
•• The timer starts when the
appliance is power on. The timer
indicator displays 01 after the
appliance has been power on
for 1 minute. The unit is minute.
•• The timer will show total breast
pumping time, pause time does
not count in.
•• If the timer displays over
99 minutes (when it comes to
100 minutes), the machine will
shut down automatically.
3
You can choose your desired
stimulation level to stimulate
milk by pressing the level up
( ) and level down ( )
buttons. You can press the
level up button to deeper
the suction. Press the level
down button to lower the
suction.There are altogether 4
stimulation levels.
»»The expression indicator
lights up instead of the
stimulation indicator.
12
English
Note
Note
•• Do not worry if your milk does
•• You do not need to use all
not flow immediately. Relax and
continue pumping. The first few
times you use the breast pump,
you may need to use a higher
expression mode to get your
milk flowing.
•• Stimulation and expression
levels match to the number of
the flowers lighting up. That is,
1 flower lighting up means level 1,
and 2 flowers lighting up means
level 2.
•• When needed, you can also
use stimulation mode to do
expression.
stimulation/expression levels,
only use the levels that are
comfortable for you.
•• Place the pump motor on a
stable and flat surface, or hang
up steadily with the included
sling, to avoid any accidental
drops when in use. If not, this
may pull the pump body off
from the breast and cause injury.
•• If you regularly express more
than 125ml per session on
each breast, you can use a
260ml/9fl oz Philips Avent
bottle to prevent overfilling and
spillage.
•• If there is no operation on
this appliance (such as pause,
change stimulation level
and expression level) for
30 minutes (including in pause),
the appliance will shut down
automatically.
6
During expression, you can
switch between the stimulation
mode and expression mode
by pressing the mode
selection button ( ) for better
expression.
7
When you have finished
expressing, press the power
button ( ) to switch off the
breast pump and carefully
remove the pump body from
your breast.
English
13
Tip
Caution
•• After switching off the breast
•• Do not continue pumping
for more than 5 minutes at a
time if you do not succeed
in expressing any milk. Try to
express at another time during
the day.
•• If the process becomes very
uncomfortable or painful, stop
using the pump and consult
your breastfeeding advisor.
•• Never tilt the breast pump
when the milk has reached the
maximum line on the bottle.
Replace with a new bottle
before re-pumping to avoid
spillage.
•• After expression, please take
off the bottle from pump body
immediately, then store the
bottle with sealing disc.
pump, break the seal between
the breast and the pump funnel
with your finger, and then
remove the pump from your
breast.
8
Disconnect the the power plug
to the power socket, and then
disconnect the power adapter
from the pump motor.
Tip
•• In order to protect the appliance,
please always shut down the
appliance by pressing the power
button instead of plugging off.
9
14
Unscrew the bottles from the
pump bodies ready for feeding/
storage. Clean the other used
parts of the breast pump
according to the instructions
in chapter ‘Cleaning and
sterilising’.
English
To pause pumping
This breast pump has a pause
function, and you can press the
pause button ( ) to pause pumping
if at any time the suction becomes
uncomfortable, there is a need to
change the bottle, reposition the
pump on the breast, or a short rest.
1
When the breast pump is in
a particular stimulation or
expression mode, press pause
button ( ) will pause the
pumping.
»»The timer indicator, level
indicator, and stimulation/
expression indicator will flash
to remind you of the pausing
status.
Note
•• Only store breast milk collected
with a sterile pump.
1
2
After you have expressed your
milk, unscrew the pump bodies
from the Philips Avent bottles.
Store expressed milk in cleaned
and sterilised Philips Avent
bottles fitted with sealing
discs. Put them in the fridge or
freezer immediately
•• You can store expressed
Note
•• When the breast pump is
in pause, level down/level
up button and stimulation/
expression switch mode button
will lose their functions. Only
pausing button and power
button still work.
2
breast milk in the refrigerator
for up to 48 hours (not in the
door) or in the freezer for up
to 3 months.
•• Label the bottles with date
and time.
•• Use up the older milk first.
Press the pause button ( )
again to continue the pumping
with the stimulation or
expression mode selected
before pausing
Storing your breast milk
Caution
•• Never refreeze breast milk.
•• Do not mix fresh breast milk to
already frozen milk.
•• Always discard any left over milk
at the end of a feed.
Philips Avent Natural Bottle
provides:
•• Natural latch on. The wide breast
shaped teat makes it easy for
your baby to combine breast and
bottle feeding.
•• Unique comfort petals. Petals
inside the teat increase softness
and flexibility without teat
collapse.
English
15
•• Advanced anti-colic valve.
Innovative twin valve design
reduces colic and discomfort by
venting air into the bottle and not
baby's tummy.
Feeding your baby with
expressed breast milk
•• If you use Philips Avent bottle
to store breast milk, make sure
to remove the sealing disc and
assemble the Philips Avent teat
for feeding.
Caution
•• Remember! Always check milk
or food temperature before
feeding.
•• Never heat breast milk in
a microwave as this may
destroy valuable nutrients and
antibodies. In addition, the
uneven heating may cause hot
spots in the liquid which could
cause burns to the throat.
•• Never immerse a frozen bottle
in boiling water to avoid crack or
split.
Keeping your electric
breast pump sterile for
travel
•• Place the frozen breast milk in the
refrigerator to defrost overnight.
In case of an emergency, you
can defrost the milk in a bowl of
hot water. Use up the defrosted
breast milk within 24 hours after
defrosting.
About heating up the breast milk:
•• Heat the bottle with in a bowl of
hot water, or using Philips Avent
bottle and baby food warmer to
safely heat up the milk.
16
English
After sterilzing all parts, please refer
to steps in "Assembling the electric
breast pump" to assemble the valve,
Massage Cushion, diaphragm and
diaphragm cap on the pump body,
then put on the pump cover and
screw on the travel cover, which
can keep your breast pump sterile
for travel.
6 Using the
manual breast
pump when
needed
3
Place the assembled manual
silicone diaphragm with stem
into the pump body.Make sure
it fits securely around the rim
by pressing down with your
fingers to ensure a perfect seal.
(This is easier if assembled
whilst wet).
4
Place the forked end of the
handle under the silicone
diaphragm and stem and push
down gently on the handle until
it clicks into place.
5
Click the pump cover onto the
pump body.
This single electric breast pump also
provide the manual breast pump
parts for you to use manual breast
pump when needed. You can follow
the below instructions to assembly
and use.
Assembling the manual
breast pump
1
2
Follow steps 1-3 in "Assembling
the electric breast pump".
Put the stem into the manual
silicone disphragm.
English
17
Using the manual breast
pump
1
Press the funnel and Massage
Cushion of the pump firmly
against your breast, making
sure that no air can escape
– otherwise there will be no
suction.
3
4
Begin by pumping 5-6 times
rapidly to initiate. Then, hold
the handle down for 2-3
seconds, and allow it to return
to its resting place. These 2-3
second cycles imitate your
baby’s natural suckling pattern
and allow the milk to flow
between strokes.
Milk should begin to flow after
the first few strokes. Don’t
worry if your milk does not
flow immediately. Relax and
continue pumping.
Note
•• For detailed information about
2
As you gently push down on
the pump handle, you will feel
the suction on your breast.
You don’t need to depress
the handle fully to create a
vacuum – only as much as is
comfortable. Your milk will
soon start flowing, even though
you may not use all the suction
the pump can generate.
18
English
warning, see it in chapter 5
"Using the electric breast pump".
7 Hints to help
you succeed
The single electric breast pump is
easy to use. Take some practice,
and you will soon get used to
expressing milk.
•• Choose a time when you are not
rushed nor interrupted easily.
•• Having your baby or a photograph
of your baby nearby can help
encourage your milk to flow.
•• Before expressing milk, place a
warm towel onto your breast, and
lightly massage for a few minutes.
This encourages milk flow, and
ease the pain of your breast.
•• Warmth and relaxation can
encourage milk flow. Try
expressing after a warm bath or
shower.
•• Try expressing from one breast
while your baby is feeding from
the other, or continue expressing
just after a feed.
•• Repositioning the pump on the
breast from time to time can help
stimulate your milk flow.
1
Open the package and take out
the breast pad.
2
Remove the sticker and put
breast pad in the bra as picture
showed, sticked it on bra to
avoid movement.
Tip
•• Practice with your pump to find
the best pumping techniques
for you. If the process becomes
painful, stop and consult your
breast-feeding advisor.
•• We recommand you to use the
breast pad to keep your bra
clean.
English
19
8 When to express
milk
If possible, wait until your milk
supply and breast-feeding schedule
are well established, unless told
otherwise by your doctor or breastfeeding advisor.
The exceptions are:
•• If you are expressing milk for your
baby to be given in hospital.
•• If your breasts are engorged
(painful or swollen). You can
express a small amount of milk
before or between feeds to ease
the pain, and to help your baby
latch on more easily.
•• If you have sore or cracked nipples
and you may wish to express your
milk until they are healed.
•• If you are separated from your
baby and wish to continue
to breast-feed when you are
reunited. You should express your
milk regularly to stimulate your
milk supply.
Right times of the day to
express your milk
•• Early in the morning when you
breasts are full, just before or after
your baby’s first feed.
•• After a feed, if your baby has not
emptied both breasts.
•• Between feeds or in a break if you
have returned to work.
20
English
9 Storage
•• Keep the breast pump out of
direct sunlight as prolonged
exposure may cause
discolouration.
•• Store the breast pump and its
accessories in a safe and dry
place.
10 Compatibility
The Philips Avent electric breast
pump is compatible with Philips
Avent bottles in our range. When
you use other Philips Avent bottles,
use the same type of teat that was
supplied with that bottle. For details
on how to assemble the teat and
general cleaning instructions, refer
to the user manual on our website,
www.philips.com/support.
11 Ordering
accessories
To purchase accessories for this
appliance, please visit our online
shop at www.shop.philips.com/
service. If the online shop is not
available in your country, go to
your Philips dealer or a Philips
service centre. If you have any
difficulties obtaining accessories
for your appliance, please contact
the Philips Consumer Care Centre
in your country. You find its contact
details in the worldwide guarantee
leaflet.
English
21
12 Recycling
Do not throw away the product with
the normal household waste at the
end of its life, but hand it in at an
official collection point for recycling.
By doing this, you help to preserve
the environment.
Follow your country's rules for the
separate collection of electrical
and electronic products. Correct
disposal helps prevent negative
consequences for the environment
and human health.
22
English
13 Guarantee and
service
Philips guarantees its products
under correct usage for a period of
two year after the date of purchase.
If any defect due to faulty materials
and workmanship occurs within
this two year guarantee period,
Philips will repair or replace the
product at its expense. For repair or
replacement, make sure to provide
convincing proof, for instance by
means of a receipt, that the day
onwhich service is claimed is within
the guarantee period.
The guarantee only covers the
breast pump motor and power
adapter. It does not cover nonelectrical parts, accessories and
consumable parts. The guarantee
does not cover shipping and
handling fees, and on-site services
fees either. If you need service
or information, or if you have a
problem, please contact the Philips
Avent Consumer Care center.
Website: http://www.philips.com/
support
14 Troubleshooting
This chapter summarises the most common problems you could encounter
with the appliance. If you are unable to solve the problem with the
information below, contact the Consumer Care Centre in your country or visit
us online at www.philips.com/support.
Problem
Solution
Lack of suction.
•
•
•
•
No milk being
expressed.
•
•
•
Pain in the
breast area when
expressing.
•
•
Milk is drawn
up the Massage
Cushion.
•
•
Check that all components are assembled correctly
and that the valve is in positioned correctly.
Make sure that the cap, the diaphragm, and the
Massage Cushion are fitted securely to the pump
body and a perfect seal is created.
The air pressure in your region is too low, this may
affect the suction.
Make sure the silicone tube is firmly connected to
the cap and the motor, without twisting.
Make sure the pump is assembled correctly, and
the suction is created.
Relax and try again; as expression may improve
with practice.
Refer to the “Hints to help you succeed” section.
You may be pumping too hard. You do not need to
use all the suction that the pump can generate but
the comfortable levels. Press the level down button
to lower down the suction intensity.
Consult your health professional/ breast feeding
advisor.
Remove and refit the Massage Cushion. Make sure
that it is installed correctly and firmly.
Try leaning lightly forward.
English
23
Problem
Solution
Cracking/
Discoloring
•
•
•
Avoid contact antibacterial or abrasive detergents/
cleaners. Combinations of detergents, cleaning
products, sterilisation solution, softened water, and
temperature fluctuations may cause the plastic to
crack. If any crack is found, stop using the pump
immediately. Contact Philips Avent Consumer Care
center for spare components.
Food coloring can discolor components, but this
will not affect your usage.
Keep all the components away from the source
of heat or direct sunlight as it can discolor
components.
Components are
broken or lost.
•
Contact Philips Avent Consumer Care center for
spare components. See back cover for contact
details.
Pump does not
response.
•
Make sure the pump is correctly assembled and
press the power button to switch on.
Make sure the cables between the pump and the
power socket are correctly connected.
•
Pump motor
display flashes
3 seconds, then
shuts down
automatically.
•
•
•
The silicone tube
is too loose when
it is plugged into
machine or cap.
24
English
•
When using the power adapter to supply power,
make sure you are using the one Philips provided.
Then make sure it is connected properly, then
switch the pump on again.
If you use batteries to supply power, press the
power button to switch off. Replace with new
batteries and switch the pump on again.
After checking the 2 scenarios above, if the
problem persists, contact the Consumer Care
center for help.
Change the new back up silicone tube connector.
目录
1
重要信息
电磁场(EMF)
2 产品简介
概述
控制面板
26
27
28
29
30
3 清洁和消毒
31
4 组装电动吸乳器
31
5 使用电动吸乳器
使用吸乳器之前
开始吸乳
暂停吸乳
母乳储存
用吸出的母乳哺喂宝宝
外出旅行途中保持电动吸乳器
处于消毒状态
33
33
33
36
36
37
6 使用手动吸乳器
组装手动吸乳器
使用手动吸乳器
38
38
39
7 成功吸乳的提示
40
11 订购配件
42
12 回收
43
13 保修与服务
44
14 故障种类和处理方法
45
38
8 吸乳的合适时间
一天中合适的吸乳时间
41
41
9 存储
41
10 兼容性
42
简体中文
25
1 重要信息
使用飞利浦新安怡单边电动吸乳器之
前,请仔细阅读本用户手册,并妥善保
管以供日后参考。您也可以在飞利浦网
站上找到本用户手册 :
www.philips.com/support
警告
• 请务必在使用后立即从电源插座拔
下插头。
• 请勿在沐浴时使用吸乳器。
• 请勿将吸乳器放置或存储在可能掉
落浴缸或水槽的地方。
• 请勿将吸乳器主机、硅橡胶管组件、
电源适配器放入或掉入水中或其它
液体中。
• 如果产品掉入水中,请勿触碰,请先
立即从电源插座拔下插头。
• 请照看好儿童,确保他们不玩耍本
产品,并将其放在儿童或宠物接触
不到的地方。
• 每次使用前先检查吸乳器(包括电
源适配器)是否存在明显破损。如果
吸乳器的电源适配器已损坏、不能
正常工作、曾被跌落或损坏,或浸入
水中,请勿使用吸乳器。
• 电源软线不能更换,如果软线损坏,
此器具(电源适配器)应废弃。
• 请使用飞利浦新安怡推荐的配件。
• 请使用本产品随附的电源适配器。
• 确保不要将吸乳器(包括电源适配
器)暴露在高温下,也不要置于阳光
直射处。
• 不建议在户外使用。
26
简体中文
• 吸乳器主机内没有用户可维修部
件。请勿尝试自行打开或修理吸乳
器主机。
• 与母乳直接接触的吸乳器部件是个
人护理物品,妈妈们不可共用。
• 吸乳器仍有吸力时,请勿尝试从乳
房上直接取下吸乳器。关闭吸乳器,
可以用手指打开乳房和吸乳器主体
之间的密封,然后从乳房上取下吸
乳器。也可以从吸乳器主机或硅橡
胶隔膜盖拔下硅橡胶管。
• 怀孕期间请勿使用吸乳器,因为吸
乳可能会导致流产。
• 请勿在您昏昏欲睡或困倦时使用吸
乳器。
• 本产品不打算由有肢体、感官或精
神能力缺陷或缺少使用经验和知识
的人(包括儿童)使用,除非有负责
他们安全的人对他们进行与本产品
使用有关的监督或指导。
• 若出现问题或疼痛,请咨询您的母
乳喂养专家或医生。
• 在易燃易爆空气中或麻醉性气体与
空气,氧气或氮氧化物混合的场合
下,请勿使用本产品。
• 尽管本吸乳器符合适用的EMC指
令,但是仍可能受到过量排放的影
响,以及/或干扰更敏感的设备。
• 使用时请勿在吸乳器主机上覆盖任
何物品,比如被子,枕头之类。使用
时,请保证吸乳器主机良好的通风
散热条件。
注意
• 将电源适配器插头插入电源插座
后,必须有人看管。
• 请勿将任何异物插入或塞入吸气口
或硅橡胶管中。
• 不建议缩短硅橡胶管。
• 将吸乳器连接至电源前,请确保
当地的电源电压符合电源适配器
要求。
• 每次使用之前,请将必要的部件进
行清洁和消毒。
• 清洁吸乳器部件时,请勿使用抗菌
剂或带腐蚀性的清洁剂或去污剂。
• 请勿将吸乳器主机组件或电源适配
器放入水中或消毒锅中,否则可能
导致吸乳器永久损坏。
• 如果产生的吸力令您感到不适或导
致疼痛,请关闭产品,并用手指打开
乳房和吸乳器主体之间的密封,从
乳房上取下吸乳器。也可以从吸乳
器主机或硅橡胶隔膜盖拔下硅橡胶
管。
• 如果没有吸出乳汁,请勿持续吸乳
超过 5 分钟。
• 请勿使用其他制造商生产的或未经
飞利浦新安怡特别推荐的配件或部
件。如果您使用了此类配件或部件,
则本产品的保修将会失效。
• 如果硅橡胶隔膜出现破损,请勿使
用吸乳器。立即更换备用硅橡胶隔
膜。请参阅《保修与服务》章节,了
解如何订购替换部件的信息。
• 请勿将奶嘴用作安抚奶嘴。避免长
牙期的宝宝长时间持续扯咬奶嘴,
以防损坏奶嘴。出于卫生考虑,建议
每3个月更换一次奶嘴;请使用飞利
浦新安怡匹配的奶瓶和奶嘴。
电池
本产品可使用普通碱性电池和充电
电池。
有关如何更换电池的说明,请参阅
“使用准备”一章。
• 充电电池充电前,应把充电电池从
吸乳器产品中取出。
• 不得将不同类型电池及新旧电池
混用。
• 应以正确极性装入电池。
• 应从产品中取出废电池,并安全
处理。
• 如果要长期存放产品而不使用,
则应将电池取出。
• 应避免电池弹簧正负极短路。
电磁场(EMF)
本飞利浦产品符合所有有关暴露于电磁
场的适用标准和法规。
简体中文
27
2 产品简介
欢迎购买并使用飞利浦新安怡产品!为了您能充分享受飞利浦新安怡提供的支持,
请在 www.philips.com/welcome 上注册您的产品。
飞利浦新安怡单边电动吸乳器为您提供舒适放松和高效泌乳的吸乳体验。飞利浦自
然韵律科技深度模拟宝宝的自然吸吮节奏,从快而浅到慢而深,帮助妈妈更舒适地
泌乳和吸乳 , 另外自然韵律科技带来均匀的吸放节奏如同宝宝吸吮的节奏 , 在短时间
内有效吸出乳汁。特有柔软的花瓣按摩垫轻柔按摩乳房刺激泌乳,更舒适放松,直
观的智能数码显示设计具有自动记忆和暂停功能,LED 背光设计适用夜间吸乳 , 易
操作。随附手柄,可以自由转换成手动吸乳器,满足您不同的吸乳需求。
医师推荐,母乳是一岁以下婴儿最好的营养食物,宝宝出生 6 个月后,可继续母乳
喂养并逐渐添加一些辅食。母乳特别适合宝宝的需要,其中含有的抗体可保护宝宝
不受感染和过敏。单边电动吸乳器可帮助您延长母乳喂养时间。您可以吸乳并储存
起来,无论您需要外出数小时、享受充分的休息或是回到工作岗位,宝宝都可以享
用您的乳汁,即使您无法亲自哺乳,宝宝都可以享用您的乳汁。由于吸乳器易于组装、
低噪音,所以您可以随身携带,在方便的时候吸乳,为宝宝提供乳汁。
28
简体中文
概述
f e
d c b
a
v
u
t
s
r
g
h
i
j
k
l
m
n
a 硅橡胶管组件
b 硅橡胶隔膜盖
o
p
q
l 防溢乳垫
m 奶瓶(125 毫升)
c 硅橡胶隔膜(x2)(另一配件备用) n 旅行封盖
d 吸乳器主体
o 吸乳器主机
e 花瓣按摩软垫
p 挂绳
f 吸乳器封盖
g 鸭嘴阀(x2)(另一配件备用)
q 储奶包
r 电源适配器
h 奶瓶盖
i 螺旋盖
s 拉杆
t 手动吸乳器硅橡胶隔膜
j 奶嘴(0 个月以上,一孔)
k 密封垫
u 手柄
v 手动吸乳器上盖
简体中文
29
控制面板
s

t
u
v
~
}
|
w
{
x
z
y
s 计时指示器
t 刺激模式指示灯
z 升档按钮
{ 暂停 / 工作按钮
u 第 2 档指示灯
v 第 1 档指示灯
| 第 4 档指示灯
} 第 3 档指示灯
w 模式选择按钮(选择刺激和吸乳模式) ~ 吸乳指示灯
x 降档按钮
 电池电量不足指示灯
y 电源按钮
注意
•• 仅当电池电量不足时,电池电量不足指示灯才会闪烁。建议您尽快更换电池。
30
简体中文
3 清洁和消毒
首次使用吸乳器以及每次使用之前,
您必须拆卸与母乳接触的所有吸乳器部
件,然后进行清洁和消毒。(请参阅
“概述”一章中的 c、d、e、f、g、
m、n、s、t)
首次及每次使用奶瓶及其配件之前,均
必须进行拆卸、清洗和消毒。(请参阅
“概述”一章中的 h、i、j、k)
4 组装电动吸乳器
要组装吸乳器,请按照以下步骤操作。
注意
•• 确保您按照本用户手册中的说明进
行清洁和消毒。
•• 确保您按照本用户手册中的说明正
确组装吸乳器。
•• 为避免泄漏,请在组装前清除吸乳
器边缘的残留物。将奶瓶安装至吸
乳器主体,不要拧得过紧。
•• 在拿取消毒过的组件之前,请彻底
洗净双手。
警告
•• 请勿对吸乳器主机、硅橡胶管组
件、硅橡胶隔膜盖和电源适配器进
行清洗或消毒。这些组件不接触母
乳。您可以用软布将这些部件擦拭
干净。
1
将鸭嘴阀插入主体的底部。
2
将奶瓶组装在主体上,轻轻沿逆时
针方向旋转,请勿过紧。
您也可以使用洗碗机(仅上搁架)或将
清洁剂加入温水中用手清洗必要部件,
然后彻底冲洗干净。建议您使用飞利浦
新安怡蒸汽消毒锅或在沸水中煮 5 分
钟,对所有与母乳接触的部件进行消毒。
警告
•• 清洁鸭嘴阀和硅橡胶隔膜的时候务
必小心。如果受损,吸乳器将无法
正常工作。
•• 要清洁鸭嘴阀,请轻轻揉搓。
请勿插入任何物件,否则可能会
造成损坏。
简体中文
31
3
将花瓣按摩软垫放入吸乳器主体的
喇叭口,并按压边缘以确保软垫与
喇叭口完全贴合,没有缝隙。
6
将硅橡胶管连接硅橡胶隔膜盖接口
和吸乳器主机接口,确保无松动泄
漏。
4
将硅橡胶隔膜放入吸乳器主体,用
手指按压,使边缘牢牢扣紧,确保
完全密封。
7
将电源适配器连接至吸乳器主机,
然后将电源插头插入电源插座。
提示
•• 您可能会发现吸乳器主体在湿的时
候更容易组装。
5
将硅橡胶隔膜盖按压在硅橡胶隔膜
上,确保与隔膜完全契合到位。
32
简体中文
注意
•• 仅使用本产品随附的适配器。请勿
使用其他适配器。
提示
5 使用电动吸乳器
•• 如需电池供电,请按底部标记所示
方向打开吸乳器主机底部电池盒盖,
然后按照标识的电池方向,将 4 节
新的碱性 1.5 伏 AA 电池装入电池
盒中。再重新装上电池盒盖。如您
要长期使用电池供电,建议您使用
充电电池。
使用吸乳器之前
•
彻底洗净双手并确保乳房清洁。从
每个乳头轻轻地挤出一点乳汁以确
保输乳管畅通。
•
确保按照“清洁和消毒”及“组
装”一章中的以下步骤对吸乳器进
行清洁、消毒和组装。
•
身体放松,坐在舒适的椅子上,
身体稍微前倾(使用靠垫支撑背
部)。在身边放一杯水。
开始吸乳
1
将吸乳器的喇叭口与花瓣按摩软垫
紧贴在乳房上,不能留有缝隙并确
保您的乳头居中,否则吸乳器将没
有吸力。
2
按电源按钮(
注意
•• 如果您在吸乳器主机的电池盒中
插入电池并且又正确连接了电源适
配器,那么吸乳器仅使用主电源运
行。另外,电池无法在吸乳器中进
行充电。
)启动吸乳器。
简体中文
33
»»屏幕会亮起 1 秒。在首次使用
时,吸乳器将以第一档刺激模
式自动启动,并且刺激模式指
示灯亮起。本产品具有记忆功
能,在您下次使用时会自动进
入您最后一次使用的刺激模式/
吸乳模式的档位。
4
乳汁开始流出后,您可以按模式选
择按钮( )切换至吸乳模式。
5
切换至吸乳模式后,您可以按升档
( )和降档( )按钮选择令您
舒适的吸力。按升档按钮逐渐增强
吸力;按降档按钮逐渐降低吸力。
吸乳模式共有四档。
»»您的乳房开始感觉到吸力。
注意
•• 产品通电后,计时器就会开始启动。
产品通电 1 分钟后,计时器指示器
会显示 01。单位为分钟。
•• 计时器将显示吸乳总时间,暂停时
间不计入。
•• 如果计时器显示时间超过 99 分钟
(达到 100 分钟时),则机器将自动
关闭。
3
34
您可以按升档( )和降档( )
按钮选择所需的刺激档位以促进泌
乳。您可以按升档按钮增大吸力。
按降档按钮则可以减小吸力。刺激
档位共有 4 档。
简体中文
»»吸乳模式指示灯(转换成吸乳
模式时)会亮起。
注意
注意
•• 如果乳汁没有立即流出,请不要着
急。放松身心,然后继续吸乳。前
几次使用吸乳器时,您可能需要使
用较强吸力才可使乳汁流出。
•• 刺激和吸乳档位与亮起的花朵数相
当。即,1 朵花亮起表示 1 档,2 朵
花亮起表示 2 档。
•• 如有需要,您也可以使用刺激模式
进行吸乳。
6
吸乳时,您可以按模式选择按钮
( )在刺激模式和吸乳模式之间
切换,以获得更佳吸乳效果。
•• 您无需使用所有刺激 / 吸乳档位,
仅使用您感觉舒适的档位。
•• 将吸乳器主机放在稳固平坦的表面
上,或用随附的挂绳稳定悬挂,以
免使用时意外跌落。如果没有这么
做,则可能导致吸乳器主体从乳房
脱出并造成伤害。
•• 如果您每次在每个乳房上的吸乳量
经常超过 125 毫升,为防止溢漏,
您可以使用 260 毫升 /9 安士飞利
浦新安怡奶瓶。
•• 使用中,如果未对本产品按钮进行
任何操作(如暂停,档位调节,模
式转换)达 30 分钟(包括处于暂
停状态),则产品将自动关机。
7
完成吸乳后,按电源按钮( )关
闭吸乳器,然后从乳房上小心地取
下吸乳器主体。
提示
•• 关闭吸乳器后,用手指打开乳房和
吸乳器主体之间的密封,然后从乳
房上取下吸乳器。
8
从电源插座上拔出插头,然后断开
电源适配器与吸乳器主机的连接。
简体中文
35
»»计时器指示灯,档位指示灯和
刺激模式指示灯/吸乳模式指示
灯会闪烁,对暂停的状态进行
提示。
提示
•• 为保护产品,请始终通过按电源按
钮(而非通过拔下插头)关闭产品。
9
从吸乳器主体上拧下用于哺喂/储
存的奶瓶。按照“清洁和消毒”一
章中的说明,清洁其他用过的吸乳
器部件。
警告
•• 如果未顺利吸出乳汁,请勿一次持
续吸乳超过 5 分钟。请尝试在当天
的其他时间吸乳。
•• 如果您在吸乳时感觉很不舒服或疼
痛,请停止使用吸乳器并咨询母乳
喂养专家。
•• 当母乳达到奶瓶上的最大标示时,
请勿倾斜吸乳器。重新吸乳前,请
使用新的奶瓶以避免溢漏。
•• 吸乳结束后,请立即从吸乳器主体
上取下奶瓶,将奶瓶用密封盖储存。
暂停吸乳
注意
•• 当吸乳器处于暂停状态时,升降档
调节按钮和档位选择按钮都将无法
操作。只有暂停按钮和电源按钮还
能正常运作。
2
再次按暂停按钮( )后,系统恢
复运行暂停前的工作模式。
母乳储存
警告
本吸乳器具有暂停功能,如果您在吸乳
时感觉不适、需要更换奶瓶、变换吸乳
器在乳房上的位置或短暂休息,则可以
随时按暂停按钮( )暂停吸乳。
•• 请勿反复冷冻母乳。
1
•• 务必丢弃哺喂后剩下的母乳。
当吸乳器处于特定刺激或吸乳模式
时,按暂停按钮( )可暂停吸
乳。
•• 不要将新鲜的母乳混入已冷冻的
母乳。
注意
•• 只能储存使用经过消毒的吸乳器收
集的乳汁。
36
简体中文
1
吸乳后,从吸乳器主体上拧下
奶瓶。
2
吸出的乳汁可以盛放在清洁并消毒
过的配有密封垫的奶瓶中,立即置
于冰箱里冷藏或冷冻。
•• 吸出的乳汁可以在冰箱中冷藏
48 个小时(并非冰箱门内侧),
或在冷冻室中冷冻 3 个月。
•• 给奶瓶贴上清晰标注吸乳日期
与时间的标签。
•• 应先使用先吸出的乳汁。
飞利浦新安怡宽口径自然 PP 奶瓶
提供 :
•
•
•
自然仿生的吸允方式。贴近母乳胸
型的奶嘴有利于宝宝以原生自然的
方式进行吸吮,母乳和奶瓶的交互
喂养可轻易实现。
特有的花瓣纹设计,吸吮更舒适。
奶嘴内的花瓣可增加柔软度和灵活
性,不会导致奶嘴扁塌。
先进的双阀门防胀气系统。创新式
双阀门设计可通过将空气排到奶瓶
中而非宝宝的肚子里,来减少胀气
和不适感。
用吸出的母乳哺喂宝宝
•
如果使用飞利浦新安怡奶瓶存储母
乳,则要确保先取下密封垫,然后
再装上消毒过的飞利浦新安怡奶嘴
进行哺喂。
•
将冷冻的母乳置于冰箱内一个晚上
以进行解冻。在紧急情况下,您可
以用一碗热水解冻母乳。母乳解冻
后,需在 24 小时内用完。
关于母乳加热 :
•
将奶瓶竖立在一碗热水中加热,或
用飞利浦新安怡奶瓶和婴儿食物加
热器安全迅速地加热母乳。
警告
•• 牢记!哺喂宝宝之前,请务必检查
母乳或食物的温度。
•• 请勿用微波炉加热母乳,因为这可
能会破坏重要的营养成分和抗体。
此外,加热不均匀可能会导致液体
局部过热,因而可能会导致烫伤。
•• 请勿将乳汁储存瓶杯浸入沸水中加
热,以免其破裂或裂开。
简体中文
37
外出旅行途中保持电动吸乳
器处于消毒状态
对各组件消毒后,请参照“组装”一章
中步骤,在吸乳器主体上安装鸭嘴阀,
花瓣按摩软垫,硅橡胶隔膜和硅橡胶隔
膜盖,然后盖上吸乳器上盖并旋上旅行
封盖,以保持外出途中吸乳器处于消毒
状态。
38
简体中文
6 使用手动吸乳器
如有需要,这款单边电动吸乳器也可以
用做手动吸乳器,您可以按照下面的指
示,组装和使用手动吸乳器。
组装手动吸乳器
1
按照“组装电动吸乳器”章节中的
步骤1-3进行组装。
2
将拉杆组装到手动吸乳器硅橡胶隔
膜上并确保安装到位。
3
将手动吸乳器硅橡胶隔膜放入吸乳
器主体,用手指按压,使边缘牢牢
扣紧,确保完全密封(湿润状态下
更易组装)。
4
将手柄前端的小叉口与手动吸乳器
硅橡胶隔膜的拉杆相扣,轻轻按压
手柄直至发出咯嗒一声完全契合到
位。
5
将吸乳器上盖装在吸乳器主体上。
使用手动吸乳器
6
将吸乳器的喇叭口与花瓣按摩软垫
紧贴在乳房上,不能留有缝隙并确
保您的乳头居中,否则吸乳器将没
有吸力。
7
轻按吸乳器手柄,就会感觉到吸
力。您不需完全按下手柄使之达到
真空状态,达到舒适程度即可。不
一定要用最大的吸力,乳汁不久就
将开始流出。
8
迅速抽吸5到6次,以产生乳汁,然
后按住手柄2到3秒,使之回到静止
状态。这2到3秒的循环是模仿婴儿
的自然吸吮模式,使乳汁能够在每
次抽动时流出。
9
乳汁应能在数次连续抽动之后开始
流出,不用担心乳汁是否能够立即
流出,放松并继续吸乳。
注意
•• 相关警告信息,
请参照章节 5 中“使
用电动吸乳器”中的警告信息。
简体中文
39
7 成功吸乳的提示
单边电动吸乳器简单易用。稍加练习,
您很快就能熟练地吸出乳汁。
•
选择您不太忙或不易被打扰的时
段。
•
让宝宝在身旁或将宝宝的照片放在
身边有助于促进母乳流出。
•
吸乳之前,将温热毛巾放在乳房
上,轻轻按摩几分钟。这可以促进
乳汁分泌并缓解乳房胀痛。
•
温暖与放松的状态可促进乳汁流
出。可尝试在温暖的沐浴或淋浴后
吸乳。
•
宝宝吸吮一只乳房的时候,可尝试
对另一只乳房吸乳,或在喂养之后
继续吸乳。
•
不时地变换吸乳器在乳房上的位置
有助于刺激乳汁分泌。
提示
•• 练习使用吸乳器,找到最适合您的
吸乳技巧。如果在使用过程中感到
疼痛,请停止使用并咨询母乳喂养
专家。
•• 建议您使用防溢乳垫以保持内衣
干净。
1
打开包装,取出防溢乳垫。
40
简体中文
2
撕开粘贴纸,如图将防溢乳垫放入
胸衣内,粘在顶部或底部,防止
滑位。
8 吸乳的合适时间
9 存储
除非医生或母乳喂养专家另有建议,最
好在您的哺乳时间有规律之后使用吸乳
器吸乳。例外情况包括 :
•
将吸乳器远离阳光直射,阳光暴晒
可能造成变色。
•
将吸乳器及其配件存放在安全干燥
的地方。
•
吸出乳汁为在医院的宝宝提供
母乳;
•
乳胀(疼痛或胀痛),您可以在喂
哺前或喂哺间隔间吸出少量乳汁以
减轻疼痛,帮助婴儿更轻松地吮吸
母乳;
•
在乳头酸痛或龟裂时,您希望能继
续母乳喂养,可以在恢复前使用吸
乳器将乳汁吸出;
•
暂时跟宝宝分开了,但希望宝宝回
到身边的时候能继续喂食,您应定
期吸乳,刺激乳汁分泌。
一天中合适的吸乳时间
•
清晨乳房涨满,在给宝宝第一次喂
哺之前或之后;
•
喂哺之后,如果宝宝没有吃完妈妈
的乳汁;
•
喂哺间隔期间,或工作休息期间。
简体中文
41
10 兼容性
飞利浦新安怡电动吸乳器兼容飞利浦
新安怡系列奶瓶。使用其他飞利浦新
安怡奶瓶时,请使用奶瓶配套的同类
型奶嘴。有关如何组装奶嘴和常规
清洁说明的详情,请参阅我们网站
(www.philips.com/support)上的用
户手册。
42
简体中文
11 订购配件
要购买本产品的配件,请访问我们的
网上商城 :www.shop.philips.com/
service。如果您的国家 / 地区没有网
上商城,请联系您的飞利浦经销商或飞
利浦服务中心。如果您购买产品的配件
有困难,请联系您所在国家 / 地区的飞
利浦客户服务中心。可在全球保修卡中
找到联系人详情。
12 回收
弃置产品时,请不要将它与一般生活垃圾一同丢弃,应将其交给官方指定的回收中心。
这样做有利于环保。
请遵循您所在国家 / 地区的电器及电子产品分类回收规定。 正确弃置产品有助于避
免对环境和人类健康造成负面影响。
飞利浦新安怡单边电动吸乳器食品接触材料信息
产品型号:SCF301
请根据说明书要求正常使用本产品。
本产品食品接触用材料及部件符合GB 4806.1-2016以及相应食品安全国家标准要
求,具体信息如下:
材质
用途
执行标准
备注
吸乳器主体、奶瓶、螺旋盖、
PP
GB 4806.7-2016
塑料
奶瓶盖、拉杆
TPE
GB 4806.7-2016
密封垫
硅橡胶隔膜、手动吸乳器硅橡胶
GB 4806.11-2016
硅橡胶
隔膜、鸭嘴阀、花瓣按摩软垫
GB 4806.2-2015
奶嘴
产品中有害物质的名称及含量
有害物质
部件名称
铅
(Pb)
电源适配器
X
O
O
O
O
O
电机内部组件
X
O
O
O
O
O
汞
镉
六价铬
多溴联苯
(Hg) (Cd) (Cr(VI)) (PBB)
多溴二苯醚
(PBDE)
本表格依据 SJ/T 11364 的规定编制。
O :表示该有害物质在该部件所有均质材料中的含量均在 GB/T 26572 规定的限量
要求以下。
X :表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572 规定
的限量要求。
* 该表格中所显示的 " 有害物质 " 在产品正常使用情况下不会对人身和环境产生任
何伤害。
* 该表格中所显示的 " 有害物质 " 及其存在的部件向消费者和回收处理从业者提供
相关物质的存在信息,有助于产品废弃时的妥善处理。
简体中文
43
13 保修与服务
自购买之日起,飞利浦为产品提供两年保修。如果在这两年保修期内由于材料缺陷和
工艺暇疵引起故障,飞利浦将负责修理或更换价格相同的产品。维修和更换产品时,
请出示有效凭证(例如收据)以确保产品仍在保修期内。
保修范围仅限于吸乳器主机和电源适配器。保修范围不含非电子部件、配件及损耗件。
保修范围不含运费、手续费和上门服务费。如果您需要服务或信息,或有任何问题,
请联系飞利浦新安怡客户服务中心。网站 :www.philips.com/support
44
简体中文
14 故障种类和处理方法
本章归纳了您在使用产品时最常遇到的问题。如果根据以下信息无法解决问题,
请联系您所在国家 / 地区的客户服务中心或在线访问我们的网站 :
www.philips.com/support。
问题
解决方法
吸力不足
•
检查所有组件是否正确组装,以及鸭嘴阀是否放置
正确。
•
确保硅橡胶隔膜、硅橡胶隔膜盖和花瓣按摩软垫都已稳
固地安装到吸乳器主体上,并确保完全密封。
•
如果您所居住的地区气压过低,可能影响吸乳器吸力。
•
确保硅橡胶管与硅橡胶隔膜盖和马达良好连接,无打结
扭曲。
•
确保正确组装和使用吸乳器。
•
放松身心,然后重试;吸乳技术可经过练习得到提高。
•
请参阅《成功吸乳的提示》部分。
无法吸出乳汁
吸乳时乳房部位疼痛 •
•
乳汁从花瓣按摩软垫 •
渗出
吸乳力度可能过大。您不需要使用吸乳器能够产生的最
大吸力,而应选择仍令您舒适的吸力。按降档按钮会减
小吸乳强度。
请咨询专业医务人士/母乳喂养专家。
拆卸并重装花瓣按摩软垫,确保紧密契合,并沿喇叭口
深处推压到位。
•
尝试稍微前倾。
•
避免接触抗菌或磨蚀性清洁剂/洗涤液。清洁剂、清洁
产品、消毒溶液、软化水和温度波动等综合因素可能导
致塑料破裂。如果发现破裂,请立即停止使用。请联系
飞利浦新安怡客户服务中心以购买备用组件。
•
食物的色素可能使组件变色,但不影响使用。
•
使所有组件远离热源或阳光直射。
组件损坏或丢失
•
请联系飞利浦新安怡客户服务中心以购买备用组件。有
关详细联系信息,请参见封底联系信息。
吸乳器没有反应
•
确保正确组装并按电源开关键启动吸乳器。
•
确保电源适配器连接正确。
开裂 / 褪色
简体中文
45
问题
解决方法
吸乳器显示面板闪 3
下并自动关机
•
使用电源设配器供电时,请首先确认使用的是飞利浦配
备的电源适配器。然后请确认是否连接正确,并重新
启动。
•
如果正使用电池供电,请按电源开关键关闭吸乳器,并
更换新电池,重新启动。
•
如果确认了上述两种状况后,此情况仍然出现,请联系
飞利浦客户服务中心寻求帮助。
硅橡胶管接头插入机 •
器或硅橡胶隔膜盖时
太松
46
简体中文
换上附送的新的硅橡胶管接头。
产品
:飞利浦新安怡单边电动吸乳器
型号
:SCF301
额定电压
:220V~
额定频率
:50Hz
额定电流
:130mA
生产日期
:请见产品本体
产地
:中国上海
飞利浦(中国)投资有限公司
上海市静安区灵石路718号A1幢
全国顾客服务热线:4008 800 008
本产品根据国标GB4706.1-2005制造
出版日期:2019-04-22
© 2019 Koninklijke Philips N.V.
保留所有权利
3000 038 30721
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertising