GE | DDC4500TWH | Installation instructions | GE DDC4500TWH Installation Instructions

GE DDC4500TWH Installation Instructions
INSTALLATION
INSTRUCTIONS
COMMERCIAL
STACKED
GAS DRYERS
10
WARNING RISK OF FIRE
‡7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOOLQVWDOODWLRQLQVWUXFWLRQV
‡&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
‡,QVWDOO WKH FORWKHV GU\HU DFFRUGLQJ WR WKHVH LQVWUXFWLRQV DQG LQ DFFRUGDQFH ZLWK ORFDO FRGHV ,Q WKH DEVHQFH RI ORFDO FRGHV
LQVWDOODWLRQPXVWFRPSO\ZLWK1DWLRQDO)XHO*DV&RGH$16,=1)3$RUWKH&DQDGLDQ1DWXUDO*DVDQG3URSDQH,QVWDOODWLRQ&RGH
&6$%
‡California Safe Drinking Water and Toxic Enforcement Act
7KLVDFWUHTXLUHVWKHJRYHUQRURI&DOLIRUQLDWRSXEOLVKDOLVWRIVXEVWDQFHVNQRZQWRWKHVWDWHWRFDXVHFDQFHUELUWKGHIHFWV
RU RWKHU UHSURGXFWLYH KDUP DQG UHTXLUHV EXVLQHVVHV WR ZDUQ FXVWRPHUV RI SRWHQWLDO H[SRVXUH WR VXFK VXEVWDQFHV *DV
DSSOLDQFHVFDQFDXVHPLQRUH[SRVXUHWRIRXURIWKHVHVXEVWDQFHVQDPHO\EHQ]HQHFDUERQPRQR[LGHIRUPDOGHK\GHDQGVRRW
FDXVHGSULPDULO\E\WKHLQFRPSOHWHFRPEXVWLRQRIQDWXUDOJDVRU/3IXHOV3URSHUO\DGMXVWHGGU\HUVZLOOPLQLPL]HLQFRPSOHWH
FRPEXVWLRQ([SRVXUHWRWKHVHVXEVWDQFHVFDQEHPLQLPL]HGIXUWKHUE\SURSHUO\YHQWLQJWKHGU\HUWRWKHRXWGRRUV
‡7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
‡8VHRQO\µULJLGPHWDOGXFWLQJIRUH[KDXVWLQJWKHFORWKHVGU\HUWRWKHRXWGRRUV
‡'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,IÀH[LEOHPHWDO VHPLULJLGRUIRLOW\SH GXFWLVLQVWDOOHG
LWPXVWEH8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFHZLWKWKHVHLQVWUXFWLRQVDQGORFDOFRGHV)OH[LEOHYHQWLQJPDWHULDOVDUH
NQRZQWRFROODSVHEHHDVLO\FUXVKHGDQGWUDSOLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
‡'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOGEHH[SRVHGWRZDWHUDQGRUZHDWKHU
‡6DYHWKHVHLQVWUXFWLRQV ,QVWDOOHUV%HVXUHWROHDYHWKHVHLQVWUXFWLRQVZLWKWKHFXVWRPHU BEFORE YOU BEGIN
Read these instructions completely and carefully
‡ IMPORTANT-6DYHWKHVHLQVWUXFWLRQVIRUORFDOLQVSHFWRU·VXVH
‡ IMPORTANT-2EVHUYHDOOJRYHUQLQJFRGHVDQGRUGLQDQFHV
‡ Note to Installer -%HVXUHWROHDYHWKHVHLQVWUXFWLRQVZLWKWKHFXVWRPHU
‡ Note to Customer -.HHSWKHVHLQVWUXFWLRQVZLWK\RXU2ZQHU·V0DQXDOIRUIXWXUH
UHIHUHQFH
‡ %HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRUGLVFDUGHGUHPRYHWKHGU\HUGRRU
‡ ,QVSHFWWKHGU\HUH[KDXVWRXWOHWDQGVWUDLJKWHQWKHRXWOHWZDOOVLIWKH\DUHEHQW
‡ 6HUYLFHLQIRUPDWLRQDQGWKHZLULQJGLDJUDPDUHORFDWHGLQWKHFRQWUROFRQVROH
‡ 'RQRWDOORZFKLOGUHQRQRULQWKHDSSOLDQFH&ORVHVXSHUYLVLRQRIFKLOGUHQLV
QHFHVVDU\ZKHQWKHDSSOLDQFHLVXVHGQHDUFKLOGUHQ
‡ ,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLVDERYHƒ)IRUVDWLVIDFWRU\RSHUDWLRQ
RIWKHGU\HUFRQWUROV\VWHP
‡ 3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRWFRYHUHGXQGHUWKH:DUUDQW\
WARNING
)RU\RXUVDIHW\WKHLQIRUPDWLRQ
LQWKLVPDQXDOPXVWEHIROORZHGWRPLQLPL]HWKHULVN
RI¿UHRUH[SORVLRQRUWRSUHYHQWSURSHUW\GDPDJH
SHUVRQDOLQMXU\RUGHDWK
-'RQRWVWRUHRUXVHJDVROLQHRURWKHUÀDPPDEOHYDSRUV
DQGOLTXLGVLQWKHYLFLQLW\RIWKLVRUDQ\RWKHUDSSOLDQFH
-WHAT TO DO IF YOU SMELL GAS
‡'RQRWOLJKWDQ\DSSOLDQFH
‡'RQRWWRXFKDQ\HOHFWULFDOVZLWFKGRQRWXVHDQ\SKRQH
LQ\RXUEXLOGLQJ
‡&OHDUWKHURRPEXLOGLQJRUDUHDRIDOORFFXSDQWV
‡,PPHGLDWHO\FDOO\RXUJDVVXSSOLHUIURPDQHLJKERU·V
SKRQH)ROORZWKHJDVVXSSOLHU·VLQVWUXFWLRQV
‡,I\RXFDQQRWUHDFK\RXUJDVVXSSOLHUFDOOWKHILUH
GHSDUWPHQW
-,QVWDOODWLRQDQGVHUYLFHPXVWEHSHUIRUPHGE\DTXDOL¿HG
LQVWDOOHUVHUYLFHDJHQF\RUWKHJDVVXSSOLHU
Printed in Canada
Tools and Materials You
Will Need
†
6OLSMRLQWSOLHUVµSLSHZUHQFKDQG
µDGMXVWDEOHZUHQFKHV [ †
6FUHZGULYHUV VORWWHGRUSKLOOLSVKHDG †
&KDLQV [ †
µ[µVWXGV
†
:DOOKRRNV
†
µGLDPHWHUULJLGPHWDOGXFWGXFW
FODPSVHOERZVDQGH[KDXVWKRRG
†
)OH[LEOHJDVFRQQHFWRU
†
3LSHFRPSRXQG
†
6RDSVROXWLRQIRUOHDNGHWHFWLRQ
†
%DVLFVDIHW\SURWHFWLRQVXFKDVVDIHW\
JRJJOHVJORYHVDQGDUPSURWHFWLRQDUH
UHFRPPHQGHG
7KH$16,=VWDQGDUGUHTXLUHVWKHIROORZLQJVDIHW\
FDXWLRQVEHSRVWHGDQGGLVSOD\HGLQDSURPLQHQW
ORFDWLRQ
D,QVWUXFWLRQVWREHIROORZHGLQWKHHYHQWWKHXVHUVPHOOV
JDV7KHLQIRUPDWLRQWREHSRVWHGVKDOOEHREWDLQHGE\
FRQVXOWLQJZLWKWKHORFDOJDVVXSSOLHU
E7KLVQRWH
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE
IN THE COMMONWEALTH OF MASSACHUSETTS
‡This product must be installed by a licensed plumber or
Jas ¿tter
‡When using ball-type gas shut-off valves, they shall be
the T-handle type
‡A flexible gas connector, when used, most not exceed 3
feet
234D1582P010 31-16677 03-12 GE
Installation Instructions
Minimum Clearance Other Than Alcove or Closet Installation
0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU&RQVLGHUDWLRQ
mustEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRURSHUDWLRQDQGVHUYLFH
Preparing the Installation Site and Unpacking the Dryer
3UHSDUHWKHDUHDDQGH[KDXVWIRULQVWDOODWLRQRIQHZGU\HU
&KHFNWREHVXUHWKHH[LVWLQJH[WHUQDOH[KDXVWLVFOHDQDQGPHHWVDWWDFKHGLQVWDOODWLRQVSHFL¿FDWLRQV
8VLQJWKHIRXUVKLSSLQJFDUWRQFRUQHUSRVWVDVSDGGLQJ WZRRQHDFKVLGH FDUHIXOO\OD\WKHGU\HURQLWVOHIWVLGHDQG
UHPRYHIRDPVKLSSLQJSDG
5HWXUQWKHGU\HUWRDQXSULJKWSRVLWLRQ
0RYHWKHGU\HUWRWKHGHVLUHGORFDWLRQ
CAUTION:
STEP 1
FOR PERSONAL SAFETY, STACKED
UNITS MUST BE FASTENED SECURELY TO WALL
7+('5<(50867127%(,167$//('256725(',1
$1$5($:+(5(,7:,//%((;326('72:$7(5$1'
25:($7+(53/($6(3529,'($'(48$7(63$&()25
23(5$7,1*$1'6(59,&,1*
'U\HUVLQVWDOOHGLQJDUDJHV LIDOORZHGE\ORFDOFRGHV PXVW
EHHOHYDWHGLQFKHV FP DERYHWKHÀRRU
WARNING
Personal Injury Hazard
Because of its weight and size, more than one person
is reTuired to lift, tilt or move the washerdryer Failure
to do so may result in personal injury
STEP 1
$WWDFKWZRFKDLQVXVLQJ3KLOOLSVKHDGVFUHZVWRHDFKHQGRI
XSSHUXQLWFDELQHW
STEP 2
/RFDWHWZRZDOOVWXGVEHKLQGGHVLUHGRSHUDWLQJORFDWLRQRI
VWDFNHGXQLWV
127()RUZDOOVWXGVQRWDSSURSULDWHO\VSDFHGVHHVHFWLRQ
IRU$OWHUQDWH0HWKRGIRU,QVWDOODWLRQRI:DOO+RRNV
STEP 3
6FUHZWZRZDOOKRRNVLQWRWZRZDOOVWXGV VDPHKHLJKWDV
FKDLQFRQQHFWLRQVRQFDELQHWRIXSSHUXQLW %RWKFKDLQV
VKRXOGSXOOVWUDLJKWEDFNWRZDOOVWXGVRUDQJOHRXWZDUG
1(,7+(5FKDLQVKRXOGDQJOHLQZDUG
127(7KH¿QDOFRQVWUXFWLRQPXVWZLWKVWDQGDSXOORI
OEV
STEP 4
&RQQHFWERWKGU\HUVWRJDVVXSSO\
6HH*$6&211(&7,21,1)250$7,21RIWKLV
LQVWUXFWLRQ
STEP 5
&RQQHFWERWKGU\HUVWRSRZHUVXSSO\ 6HH(/(&75,&$/
&211(&7,21,1)250$7,21VHFWLRQRIWKLVLQVWUXFWLRQ
STEP 6
&RQQHFWERWKGU\HUVWRH[WHUQDOH[KDXVW 6HH(;+$867
,1)250$7,21VHFWLRQRIWKLVLQVWUXFWLRQ
STEP 7
+RRNERWKFKDLQVIURPXSSHUXQLWWRDSSURSULDWHZDOOKRRNV
WDNLQJXSDQ\VODFN
STEP 8
$GMXVWDOOOHYHOOLQJOHJV'U\HUPXVWEHOHYHOOHGDQGUHVW
¿UPO\RQDOOOHYHOOLQJOHJV
STEP 2
STEP 3
STEP 8
Installation Instructions
Alternate Method for Installation of Wall Hooks
STEP 1
,IZDOOVWXGVDUHQRWFRUUHFWO\VSDFHGRUFHQWHUHGEHKLQGXSSHUXQLWLW
PD\EHQHFHVVDU\WRDWWDFKDKRUL]RQWDOµ[µERDUGWRWKHH[LVWLQJZDOO
STEP 2
$WWDFKZDOOKRRNVLQDSSUR[LPDWHSRVLWLRQRIWZRFKDLQVRIXSSHUXQLWVR
HDFKFKDLQSXOOVVWUDLJKWEDFNWRZDOO
127(,IZDOOLVFRQFUHWHRUEORFNGULOOKROHVDQGXVHDSSURSULDWHZDOO
DQFKRUV7KH¿QDOFRQVWUXFWLRQPXVWZLWKVWDQGDSXOORIOEV
1 PREPARING FOR INSTALLATION OF
2 GAS REQUIREMENTS
NEW DRYER
WARNING
TIP: Install your dryer before installing your washer
This will allow better access when installing dryer exhaust
‡ ,QVWDOODWLRQPXVWFRQIRUPWRORFDOFRGHVDQG
RUGLQDQFHVRULQWKHLUDEVHQFHWKH1$7,21$/)8(/*$6
&2'($16,=
‡ 7KLVJDVGU\HULVHTXLSSHGZLWKD9DOYH %XUQHU
$VVHPEO\IRUXVHRQO\ZLWKQDWXUDOJDV8VLQJFRQYHUVLRQ
NLW:(;\RXUORFDOVHUYLFHRUJDQL]DWLRQFDQ
FRQYHUWWKLVGU\HUIRUXVHZLWKSURSDQH /3 JDV$//
&219(56,2160867%(0$'(%<3523(5/<75$,1('
$1'48$/,),('3(56211(/$1',1$&&25'$1&(:,7+
/2&$/&2'(6$1'25',1$1&(5(48,5(0(176
‡ 7KHGU\HUPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\
SLSLQJV\VWHPGXULQJDQ\SUHVVXUHWHVWLQJRIWKDWV\V
WHPDWDWHVWSUHVVXUHLQH[FHVVRI36, .3D ‡ 7KHGU\HUPXVWEHLVRODWHGIURPWKHJDVVXSSO\SLSLQJ
V\VWHPE\FORVLQJWKHHTXLSPHQWVKXWRȺYDOYHGXULQJ
DQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\SLSLQJRIWHVW
SUHVVXUHHTXDOWRRUOHVVWKDQ36, .3D DISCONNECTING GAS
TURN GAS
SHUT-OFF
VALVE TO THE
OFF POSITION.
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD DUCTING MATERIAL.
REPLACE WITH NEW CSA(AGA)
APPROVED FLEXIBLE GAS LINE
CONNECTOR AND UL APPROVED
TRANSITION DUCT.
WARNING - NEVER REUSE
OLD FLE;IBLE CONNECTORS
7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNV
DQGSHUVRQDOLQMXU\$OZD\VXVHQHZÀH[LEOH
FRQQHFWRUVZKHQLQVWDOOLQJJDVDSSOLDQFHV
DRYER GAS SUPPLY CONNECTION
REMOVING LINT FROM WALL EXHAUST
OPENING
2"
‡ 5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO
WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW
WALL
INTERNAL DUCT
OPENING
3/8" NPT MALE THREAD GAS SUPPLY
2-5/8"
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
CHECK THAT EXHAUSE
HOOD DAMPER OPENS
AND CLOSES FREELY.
GAS SUPPLY
‡ $LQ1DWLRQDO3LSH7DSHUWKUHDGSOXJJHGWDSSLQJ
DFFHVVLEOHIRUWHVWJDXJHFRQQHFWLRQPXVWEHLQVWDOOHG
LPPHGLDWHO\XSVWUHDPRIWKHJDVVXSSO\FRQQHFWLRQWR
WKHGU\HU&RQWDFW\RXUORFDOJDVXWLOLW\VKRXOG\RXKDYH
TXHVWLRQVRQWKHLQVWDOODWLRQRIWKHSOXJJHGWDSSLQJ
‡ 6XSSO\OLQHLVWREHLQULJLGSLSHDQGHTXLSSHGZLWK
DQDFFHVVLEOHVKXWRȺZLWKLQIWRIDQGLQWKHVDPH
URRPZLWKWKHGU\HU
‡ 8VHSLSHWKUHDGVHDOHUFRPSRXQGDSSURSULDWHIRU
QDWXUDORU/3JDVRUXVH7HÀRQWDSH
‡ <RXPXVWXVHZLWKWKLVGU\HUDÀH[LEOHPHWDOFRQQHFWRU
OLVWHGFRQQHFWRU$16,=&6$ 7KHOHQJWKRI
WKHFRQQHFWVKDOOQRWH[FHHGIW
‡ &RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\
‡ 2SHQVKXWRȺYDOYH
‡ 7,/77+('5<(56,'(:$<6$1'5(029(7+()2$0
6+,33,1*3$'6%<38//,1*$77+(6,'(6$1'
%5($.,1*7+(0$:$<)5207+('5<(5/(*6%(685(
725(029($//2)7+()2$03,(&(6$5281'7+(
/(*6
Installation Instructions
3 RECONNECTING GAS
Listed connector ANSI Z21.24 / CSA 6.10
NPT
FLARE
APPLY PIPE COMPOUND
TO ALL MALE THREADS.
ADAPTER
1/8" NPT PIPE
PLUG FOR
CHECKING GAS
INLET PRESSURE
NEW METAL
FLEXIBLE GAS
LINE CONNECTOR
ADAPTER
3/8" NPT
SHUT-OFF
VALVE
ELBOW
PIPE SIZE
AT LEAST 1/2"
ITEMS NOT SUPPLIED
127(7KHFRQQHFWRUDQG¿WWLQJVDUHGHVLJQHGIRUXVH
RQO\RQWKHRULJLQDOLQVWDOODWLRQDQGDUHQRWWREHUHXVHG
IRUDQRWKHUDSSOLDQFHRUDWDQRWKHUORFDWLRQ.HHSÀDUH
HQGRIDGDSWRUIUHHRIJUHDVHRLODQGWKUHDGVHDODQW
CAUTION
: 8VHDGDSWRUVDVVKRZQ&RQQHFWRU
QXWVPXVWQRWEHFRQQHFWHGGLUHFWO\WRSLSHWKUHDGV
7LJKWHQDOOFRQQHFWLRQVXVLQJWZRDGMXVWDEOH
ZUHQFKHV Do not over torque gas connections!
4 LEAK TEST
WARNING - NEVER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS
APPLY PIPE COMPOUND
TO THE ADAPTER AND
DRYER GAS INLET.
OPEN
GAS VALVE.
Tighten the flexible
gas line using two
adjustable wrenches.
&KHFNDOOFRQQHFWLRQVIRUOHDNVZLWKVRDS\VROXWLRQRU
HTXLYDOHQW$SSO\VRDSVROXWLRQLeak test solution must
not contain ammonia which could cause damage to the
brass ¿ttings,IOHDNVDUHIRXQGFORVHYDOYHUHWLJKWHQWKH
MRLQWDQGUHSHDWWKHVRDSWHVW
Installation Instructions
6 EXHAUST CONNECTION
5 EXHAUST INFORMATION
WARNING - BEFORE PERFORMING
THIS EXHAUST INSTALLATION, BE SURE TO
DISCONNECT THE DRYER FROM ITS ELECTRICAL
SUPPLY PROTECT YOUR HANDS AND ARMS
FROM SHARP EDGES WHEN WORKING INSIDE
THE CABINET BE SURE TO WEAR GLOVES
WARNING - TO REDUCE THE RISK
OF FIRE OR PERSONAL INJURY:
‡7KLVFORWKHVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
‡8VHRQO\µULJLGPHWDOGXFWLQJIRUKRPHH[KDXVWGXFW
‡8VHRQO\µULJLGPHWDORU8/OLVWHGÀH[LEOHPHWDO VHPL
ULJLGRUIRLOW\SH GXFWWRFRQQHFWWKHGU\HUWRWKHKRPH
H[KDXVWGXFW,WPXVWEHLQVWDOOHGLQDFFRUGDQFHZLWK
WKHVHLQVWUXFWLRQVDQGORFDOFRGHV
‡'RQRWWHUPLQDWHH[KDXVWLQDFKLPQH\DZDOODFHLOLQJ
JDV YHQW FUDZO VSDFH DWWLF XQGHU DQ HQFORVHG ÀRRU
RU LQ DQ\ RWKHU FRQFHDOHG VSDFH RI D EXLOGLQJ 7KH
DFFXPXODWHGOLQWFRXOGFUHDWHDSRWHQWLDO¿UHKD]DUG
‡1HYHUWHUPLQDWHWKHH[KDXVWLQWRDFRPPRQGXFWZLWK
DNLWFKHQH[KDXVWV\VWHP$FRPELQDWLRQRIJUHDVHDQG
OLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG
‡'R QRW XVH GXFW ORQJHU WKDQ VSHFL¿HG LQ WKH H[KDXVW
OHQJWKWDEOH/RQJHUGXFWVFDQDFFXPXODWHOLQWFUHDWLQJ
DSRWHQWLDO¿UHKD]DUG
‡1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
ZLOO FDXVH OLQW WR DFFXPXODWH FUHDWLQJ D SRWHQWLDO ¿UH
KD]DUG
‡'R QRW DVVHPEOH GXFWZRUN ZLWK DQ\ IDVWHQHUV WKDW
H[WHQGLQWRWKHGXFW7KHVHIDVWHQHUVFDQDFFXPXODWH
OLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
‡'RQRWREVWUXFWLQFRPLQJRUH[KDXVWHGDLU
‡3URYLGH DQ DFFHVV IRU LQVSHFWLRQ DQG FOHDQLQJ RI WKH
H[KDXVW V\VWHP HVSHFLDOO\ DW WXUQV DQG MRLQWV ([KDXVW
V\VWHPVKDOOEHLQVSHFWHGDQGFOHDQHGDWOHDVWRQFHD\HDU.
‡,QVSHFLDOLQVWDOODWLRQVLWPD\EHQHFHVVDU\WRFRQQHFW
WKHGU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDO IRLO
W\SH GXFW $ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW
PD\EHXVHG21/<LQLQVWDOODWLRQVZKHUHULJLGPHWDORU
ÀH[LEOHPHWDO VHPLULJLG GXFWLQJFDQQRWEHXVHG$1'
ZKHUH D µ GLDPHWHU FDQ EH PDLQWDLQHG WKURXJKRXW
WKHHQWLUHOHQJWKRIWKHWUDQVLWLRQGXFW,Q&DQDGDDQG
LQ WKH 8QLWHG 6WDWHV RQO\ WKH ÀH[LEOH PHWDO IRLOW\SH GXFWV WKDW FRPSO\ ZLWK WKH ´2XWOLQH IRU &ORWKHV 'U\HU
7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG
7KHGU\HUVFRPHVUHDG\IRUUHDUH[KDXVWLQJ8QLWVKDYH
VHSDUDWHH[KDXVWV
REAR EXHAUST LOCATION
Screw location
inside duct
3 1/2"
11 3/4"
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
‡ 7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\RI
ELUGVRURWKHUZLOGOLIH
‡ 7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWR
WKHH[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQR
PDLQWHQDQFHWRSUHYHQWFORJJLQJ
‡ 1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
FRXOGFDXVHOLQWEXLOGXS
‡ :DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQG
OHYHORUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHGGRZQ
SEPARATION OF TURNS
)RUEHVWSHUIRUPDQFHVHSDUDWHDOOWXUQVE\DWOHDVWIW
RIVWUDLJKWGXFWLQFOXGLQJGLVWDQFHEHWZHHQODVWWXUQDQG
H[KDXVWKRRG ZDOOFDS ,IWZRWXUQVPXVWEHFORVHUWKDQ
IWGHGXFWIWIURPWKHPD[LPXPOHQJWKVVKRZQLQWKH
WDEOHIRUHDFKRFFXUUHQFH
TURNS OTHER THAN 90º
‡ 2QHWXUQRIžRUOHVVPD\EHLJQRUHG
‡ 7ZRžWXUQVVKRXOGEHWUHDWHGDVRQHžWXUQ
‡ (DFKWXUQRYHUžVKRXOGEHWUHDWHGDVRQHžWXUQ
SEALING OF JOINTS
‡ $OOMRLQWVVKRXOGEHWLJKWWRDYRLGOHDNV7KHPDOHHQGRI
HDFKVHFWLRQRIGXFWPXVWSRLQWDZD\IURPWKHGU\HU
‡ 7KHGXFWVKDOOQRWEHDVVHPEOHGZLWKVFUHZVRURWKHU
IDVWHQLQJPHDQVWKDWH[WHQGLQWRWKHGXFWDQGFDWFKOLQW
‡ 'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\
ZUDSSLQJWKHRYHUODSSHGMRLQWVZLWKGXFWWDSH
‡ +RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUV
LQFKSHUIRRW
INSULATION
'XFWZRUNWKDWUXQVWKURXJKDQXQKHDWHGDUHDRULV
QHDUDLUFRQGLWLRQLQJVKRXOGEHLQVXODWHGWRUHGXFH
FRQGHQVDWLRQDQGOLQWEXLOGXS
NOTE:1HYHULQVWDOOVFUHHQLQVLGHH[KDXVWGXFW
EXHAUST LENGTH
7KHMAXIMUM ALLOWABLEGXFWOHQJWKDQGQXPEHURI
EHQGVRIWKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRI
GXFWQXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRG ZDOOFDS DQGDOOFRQGLWLRQVQRWHGEHORZ7KHPD[LPXPGXFWOHQJWK
IRUULJLGPHWDOGXFWLVVKRZQLQWKHWDEOHEHORZ
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Use only for short
run installations
Recommended
4" DIA.
4" DIA.
4"
No. of 90° Elbows
0
1
2
Rigid Metal
45 ft.
35 ft.
25 ft.
NOTE: Add
to vertical
dimension
the distance
between
cabinet
bottom to
ÀRRUVXUIDFH
2-1/2"
Rigid Metal
30 ft.
20 ft.
10 ft.
0RUHWKDQWZRƒWXUQVLVQRWUHFRPPHQGHG7KHWRWDO
OHQJWKRIÀH[LEOHPHWDOGXFWVKDOOQRWH[FHHGIW P ,Q
&DQDGDDQGLQWKH8QLWHG6WDWHVWKHUHTXLUHGH[KDXVWGXFW
GLDPHWHULVµ PP Installation Instructions
6 EXHAUST CONNECTION CONT
7 ALCOVE OR CLOSET INSTALLATION
THIS DRYER COMES READY FOR REAR
EXHAUSTING IF SPACE IS LIMITED, USE
THESE INSTRUCTIONS TO EXHAUST
DIRECTLY FROM THE LEFT SIDE OR
BOTTOM OF THE CABINET NOTE: This
dryer cannot be exhausted to the right
side
‡,I \RXU GU\HU LV DSSURYHG IRU LQVWDOODWLRQ LQ DQ DOFRYH RU
FORVHWLWZLOOEHVWDWHGRQDODEHORQWKHGU\HUEDFN
‡7KH GU\HU MUST EH YHQWHG WR WKH RXWGRRUV 6HH WKH
EXHAUST INFORMATIONVHFWLRQ
‡0LQLPXPFOHDUDQFHIURPFRPEXVWLEOHVXUIDFHVDQGQRQ
FRPEXVWLEOHVXUIDFHVIRUDLULQWDNHSXUSRVHVLV
LQHLWKHUVLGH
LQIURQWDQGUHDU
‡ Never use Àexible duct inside dryer
‡'HWDFK DQG UHPRYH WKH ERWWRP RU OHIW VLGH NQRFNRXW DV
GHVLUHG
‡5HPRYH WKH VFUHZ LQVLGH WKH GU\HU H[KDXVW GXFW DQG VDYH
3XOOWKHGXFWRXWRIWKHGU\HU3URWHFWVKDUSHGJHVDURXQGWKH
NQRFNRXWDQGH[KDXVWRSHQLQJZLWKWKHWDSH
‡&XWWKHGXFWDVVKRZQ.HHSSRUWLRQ$
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE
REAR OF THE DRYER, MINIMUM CLEARANCE FROM THE
WALL IS 55 in
‡0LQLPXPYHUWLFDOVSDFHIURPÀRRUWRRYHUKHDGFDELQHWV
FHLOLQJHWFLVLQ
FIXING HOLE
B
‡&ORVHW GRRUV PXVW EH ORXYHUHG RU RWKHUZLVH YHQWLODWHG
DQGPXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHD
HTXDOO\ GLVWULEXWHG ,I WKH FORVHW FRQWDLQV ERWK D ZDVKHU
DQGDGU\HUGRRUVPXVWFRQWDLQDPLQLPXPRIVTLQ
RIRSHQDUHDHTXDOO\GLVWULEXWHG
A
9"
‡7KURXJKWKHUHDURSHQLQJORFDWHWKHWDELQWKHPLGGOHRI
WKHDSSOLDQFHEDVH/LIWWKHWDEWRDERXWƒXVLQJDÀDW
VFUHZGULYHU
‡5HFRQQHFWDQGVHFXUHWKHFXWSRUWLRQ $ RIWKHGXFW
WRWKHEORZHUKRXVLQJ0DNHVXUHWKDWWKH¿[LQJKROHLV
DOLJQHGZLWKWKHWDELQWKHEDVH8VHWKHVFUHZRILWHP
WRVHFXUHWKHGXFWLQSODFHWKURXJKWKHWDERQWKH
DSSOLDQFHEDVH
‡7KH FORVHW VKRXOG EH YHQWHG WR WKH RXWGRRUV WR SUHYHQW
JDVSRFNHWLQJLQFDVHRIDJDVOHDNLQWKHVXSSO\OLQH
‡1RRWKHUIXHOEXUQLQJDSSOLDQFHVKDOOEHLQVWDOOHGLQWKH
VDPHFORVHWZLWKWKHGU\HU
‡8VHVWDQGDUGPHWDOHOERZVDQGGXFWWRFRPSOHWH
H[KDXVWV\VWHP,QVHUWVWDQGDUGHOERZDQGGXFWV
WKURXJKUHDUDQGVLGHRUERWWRPRSHQLQJV
‡&RYHUWKHRSHQLQJDWWKHEDFNZLWKWKHSODWH .LW
:(0 DYDLODEOHIURP\RXU/RFDO6HUYLFH3URYLGHU
WARNING-NEVER LEAVE THE
BACK OPENING WITHOUT THE PLATE
PARTS AVAILABLE FROM LOCAL SERVICE
ORGANIZATION
‡5LJLG0HWDO'XFW&RPSRQHQWV
:;;µ;·'XFW
:;;µ[·'XFW
:;;µ(OERZ
:;;$OXPLQXP+RRG
‡)OH[LEOH0HWDO'XFW&RPSRQHQWV
:;;µGLD)OH[LEOH0HWDO 6HPL5LJLG 8//LVWHG7UDQVLWLRQ'XFW LQFOXGHVHOERZV
Installation Instructions
ADJUSTING FOR ELEVATION
8 ELECTRICAL CONNECTION INFORMATION
‡ *DVFORWKHVGU\HUVLQSXWUDWLQJVDUHEDVHGRQVHDOHYHO
RSHUDWLRQDQGQHHGQRWEHDGMXVWHGIRURSHUDWLRQDWRU
EHORZIWHOHYDWLRQ
)RURSHUDWLRQDWHOHYDWLRQVDERYHIWLQSXWUDWLQJV
VKRXOGEHUHGXFHGDWDUDWHRISHUFHQWIRUHDFKIW
DERYHVHDOHYHO
‡ ,QVWDOODWLRQPXVWFRQIRUPWRORFDOFRGHVDQGRUGLQDQFHVRU
LQWKHLUDEVHQFHWKH1$7,21$/)8(/*$6&2'($16,=
WARNING - TO REDUCE THE RISK
OF FIRE, ELECTRICAL SHOCK, AND
PERSONAL INJURY:
‡ DO NOT USE AN EXTENSION CORD
OR AN ADAPTER PLUG WITH THIS
APPLIANCE
NOTE TO INSTALLER
'U\HUPXVWEHHOHFWULFDOO\JURXQGHGLQDFFRUGDQFH
ZLWKORFDOFRGHVDQGRUGLQDQFHVRULQWKHDEVHQFH
RIORFDOFRGHVLQDFFRUGDQFHZLWKWKH1$7,21$/
(/(&75,&$/&2'($16,1)3$12
AFTER INSTALLATION CHECK THE FOLLOWING:
†(;+$867'8&70XVWPHHWVSHFVLQWKH(;+$867
,1)250$7,21VHFWLRQ
†*5281',1*'U\HUPXVWEHSURSHUO\JURXQGHGWRFRQIRUPWR
ORFDOFRGHVDQGRUGLQDQFHUHTXLUHPHQWV
†23(5$7,217XUQGU\HURQDQGFKHFNIRUKHDW
†+DQGFXVWRPHUWKH2ZQHU·V0DQXDO*LYHLQVWUXFWLRQVRQ
RSHUDWLQJWKHGU\HU$QVZHUDQ\TXHVWLRQV
†*LYHWKHVH,QVWDOODWLRQ,QVWUXFWLRQVWRWKHFXVWRPHU
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch
circuit, protected by a 15- or 20-amp circuit breaker or
time delay fuse If electrical supply provided does not
meet the above speci¿cations, it is recommended that
a licensed electrician install an approved outlet
CARE AND CLEANING
USER MAINTENANCE INSTRUCTIONS
The Drum 7KHGUXPLVUXVWUHVLVWDQWDQGUHTXLUHV
QRVSHFLDOFDUH
The Exterior :LSH RȺ DQ\ VSLOOV RU ZDVKLQJ FRPSRXQGV
:LSHRUGXVWZLWKGDPSFORWK7U\QRWWRVWULNHWKHVXUIDFH
ZLWKVKDUSREMHFWV
The Lint Filter:LSHOLQW¿OWHUEHIRUHHYHU\XVH3HULRGLFDOO\
OLQW¿OWHUVKRXOGEHUHPRYHGDQGVXFWLRQKRVHIURPYDFXXP
FOHDQHUVKRXOGEHLQVHUWHGLQWRWKHRSHQLQJ
Dryer Exhaust ,QVSHFW DQG FOHDQ WKH GU\HU H[KDXVW
GXFWLQJDWOHDVWRQFHD\HDU
'RQRWREVWUXFWWKHÀRZRIFRPEXVWLRQDQGYHQWLODWLQJDLU
7KHDLULQWDNHLVORFDWHGRQUHDURIGU\HU
.HHSGU\HUDUHDFOHDUDQGIUHHIURPFRPEXVWLEOHPDWHULDOV
JDVROLQHDQGRWKHUÀDPPDEOHYDSRUVDQGOLTXLGV
To store dryer )RUVKRUWSHULRGRIWLPHGLVFRQQHFWSRZHU
VXSSO\DQGFOHDQOLQW¿OWHU
'RQRWLQVWDOORUVWRUHGU\HUZKHUHLWZLOOEHH[SRVHGWRWKH
ZHDWKHU
WARNING - THIS DRYER IS
EQUIPPED WITH A THREE-PRONG
(GROUNDING) PLUG FOR YOUR
PROTECTION AGAINST SHOCK HAZARD
AND SHOULD BE PLUGGED DIRECTLY
INTO AN INDIVIDUAL, PROPERLY
GROUNDED THREE-PRONG RECEPTACLE
DO NOT CUT OR REMOVE THE
GROUNDING PRONG FROM THIS PLUG
ENSURE PROPER GROUND EXISTS BEFORE USE
CAUTION:
‡'U\HUFRQWUROSDQHODQG¿QLVKHVPD\EHGDPDJHGE\
VRPHODXQGU\SUHWUHDWPHQWVRLODQGVWDLQUHPRYHU
SURGXFWVLIVXFKSURGXFWVDUHVSUD\HGRQRUKDYHGLUHFW
FRQWDFWZLWKWKHGU\HU
$SSO\WKHVHSUHWUHDWPHQWSURGXFWVDZD\IURPWKH
GU\HU7KHIDEULFPD\WKHQEHZDVKHGDQGGULHG
QRUPDOO\'DPDJHWR\RXUGU\HUFDXVHGE\SUHWUHDWPHQW
SURGXFWVLVQRWFRYHUHGE\\RXU:DUUDQW\
EXTERNAL GROUND (IF REQUIRED)
$QH[WHUQDOJURXQGZLUH QRWSURYLGHG ZKLFKPHHWVORFDO
FRGHVPD\EHDGGHGE\DWWDFKLQJWRWKHJUHHQJURXQG
VFUHZRQWKHUHDURIWKHGU\HUDQGWRDJURXQGHGPHWDO
FROGZDWHUSLSHRURWKHUHVWDEOLVKHGJURXQG
REGISTER YOUR NEW APPLIANCE TO RECEIVE ANY
IMPORTANT PRODUCT NOTIFICATIONS
3OHDVHJRWRZZZ*($SSOLDQFHVFRPRUPDLOLQWKH
3URGXFW5HJLVWUDWLRQ&DUG
ATTACH GROUND WIRE (OBTAIN
LOCALLY) TO EACH DRYER
)RUTXHVWLRQVRQLQVWDOODWLRQFDOO 86 RU
&DQDGD Installation Instructions
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising