GE | AZ28E09DAB | Sales Guide | GE AZ28E15EAB Sales Guide

GE AZ28E15EAB Sales Guide
GE Zoneline packaged
terminal air conditioners
®
Preliminary specifications
®
ge.com
Zoneline . Efficient. Quiet.
Reliable. Innovative.
®
Versatile Zoneline® Packaged Terminal Air Conditioners provide year-round comfort
with individual heating and cooling temperature controls. Designed for a wide range of
applications, these units are ideal for hotels and motels, office buildings, schools and
apartments. All Zoneline units feature the exclusive GE® “Superseal” system which
minimizes energy usage by reducing air infiltration. The result is maximum operating
efficiency and a more comfortable room. All Zoneline units are also very quiet thanks to
lower sound level and lower sound transmission. The newest innovation in Zoneline units
is the Dry Air 25 Series. Similar to our Deluxe 2800 Series, the Dry Air 25 removes 25%
more moisture from the air than standard GE packaged terminal air conditioners.
Zoneline® features and benefits
Electronic tactile controls
Central desk control
Premium 5800 Series Zoneline units are equipped with
microcomputer touch controls. This feature gives the
user finer control over the temperature with a touch
pad and an LED readout.
All Zoneline units are compatible with two-wire central
desk ON/OFF controls, including many computerized
control systems. They can also be wired directly to
infrared sensors and door switches to maximize efficiency.
Remote installation capability
Optional corrosion treatment
All Zoneline units are compatible with GE wall-mounted
remote thermostats. Mechanical, digital and programmable
thermostats are available.
®
Deluxe Zoneline units can be ordered with special
treatment to reduce the effects of corrosive
environments. Special treatments are placed on
the outdoor coil and other components to extend
the life of the unit.
Model shown: PDW9880J
ge.com
The Dry Air 25
Freeze Sentinel™
The Dry Air 25 Series centers around GE’s exclusive use of
the patented Dinh® Dehumidifier Heat Pipe from Heat Pipe
Technology, Inc. This innovative NASA spin-off technology
enables the Dry Air 25 to remove 25% more moisture from
the air than standard GE packaged terminal air conditioners.
The Dry Air 25 is perfect for high humidity climates. Available
on 7000, 9000 and 12000 BTU models.
All Zoneline units are equipped with Freeze Sentinel to
provide protection against damage caused by freezing
temperatures in unoccupied rooms, regardless of unit
setting. In installations where freezing temperature is
not a concern, the owner has the option of disabling
the Freeze Sentinel.
Heat Sentinel
Upfront filters
Provides automatic protection against overheating by
switching on the unit to cool should the temperature
of an unoccupied room reach 85°F.
For ease of cleaning, all Zoneline units have interchangeable
removable upfront filters made of long lasting nylon mesh,
thus assuring high performance and long life.
Electronic temperature limiting
Heating and cooling temperatures may be electronically
limited on all series to prevent expensive overcooling or
overheating. Heating and cooling limits are independently
set so seasonal adjustment is unnecessary.
Easy installation and flexibility of design
Zoneline® units are designed with innovative, universal
components, and offer even greater installation flexibility
than ever, whether in new construction, renovation or
for replacement of old units. Unless specified by code,
they require no sub-base and may be installed flush with
finished floor. All models are adaptable to remote and
central desk control. Zoneline units may even be placed
in unusual locations, such as transom or common area
installations. The two lines, Deluxe and Premium, each
with its own special blend of features, offer flexibility to
meet each zone application. All units come with
microcomputer controls.
Wall sleeve
RAB71A (Shown)
RAB77 (SMC) (Not Shown)
Room cabinet
Deluxe 2800 series
cooling with resistance heat
Deluxe Dry Air 25 series
cooling with resistance heat
• Two fan motors
- Improved quiet sound levels
- Higher efficiency
• Electronic temperature limiting
- Reduces operating costs
• Optional corrosion treatment
- Reduces the effects of coastal
environments
• Freeze sentinel™
- Protects unoccupied rooms from damage
by freezing temperatures
• Heat sentinel
- Reduces excessive temperatures in unoccupied room
• GE exclusive superseal
- Increased room comfort
- Energy savings
• Upfront filters
- Ease of cleaning
- Long lasting nylon mesh
• Central desk control compatibility with
options for infrared/door switch sensors
• Remote thermostat capability
• Smartfan
- Fan cycle operation based on
heat/cool selection
Includes all features of 2800 series, plus:
• Removes 25% more moisture from the air
than standard GE packaged terminal air
conditioners
• Cool and dry air in less time than standard
Zoneline models
• Maintains comfort at slightly higher room
temperatures
- Reduces operating costs
- Provides comfort without overcooling
• Corrosion treatment is standard
• Heat pipe is a separate sealed
refrigerant system
- No mechanical parts
- No special maintenance required
• Helps maintain lower relative humidity
in rooms
• Best suited for humid climates
Deluxe 3800 series
cooling with heat pump
and resistance heat
Includes all features of 2800 series, plus:
• Reverse cycle heating
- Energy savings over electric
resistance heat
- Significantly lower operating costs
• Heat pump operation down to 25°f
outdoor temperature
• Two-stage thermostat for quicker
heat recovery
• Optional factory installed internal
condensate removal (ICR)
- Minimizes need for drain systems
• Heat pump and resistance heat can
operate together
- Better room comfort
- Reduces operating costs over all
standard heat pump systems
• Reverse cycle defrost
- Extends heat pump operation
- Lowers operating costs
• Electric resistance heat lockout
- Lowers operating costs by restricting
electric heat operation when outdoor
temperature is above 46°f.
ge.com
Grille options
Extruded aluminum:
RAG67 (Shown)
Stamped aluminum grille
RAG60
Exterior architectural louvers
Durable polycarbonate:
RAG61 or RAG64 (Beige)
RAG62 or RAG65 (Maple)
RAG63 or RAG66 (Bittersweet)
Retrofit kits (not shown)
RAK901L - Wall Case Insulation for use
with Heat Pumps
RAK40 - Deflector Kit to adapt chassis for
use with existing exterior architectural
louvered grilles
Requires power connection kit
Grille
Chassis
Premium 5800 series
cooling with heat pump
and resistance heat
Includes all features of 3800 series, plus:
• Two fan motor system with indoor
cross flow blower
- For quieter operation
• Digital controls
- Led temperature display
- Easy temperature selection
- Tactile touch pads
• Corrosion treatment is standard
• Self diagnostics
Resistance heat
Features
Standard microcomputer controls
Highly-featured
microcomputer controls
Rotary control knobs
Tactile touch pad controls with LED
Universal heaters
Solid-state thermostat
3 position vent control
Upfront filter (interchangeable)
Automatic indoor frost control
Corrosion treated chassis
2-position discharge grille
Fan motors
“SmartFan” Fan cycle control
Fan Only setting—2-speed
Indoor fan speed
Cool & heat only settings
Staged heating
Freeze Sentinel™
Heat Sentinel
Temperature limiting
Remote control compatibility
Central desk control compatibility
Service indicator
Heat pump with resistance
heat back-up
Heat pump with supplemental
resistance heat
Automatic emergency heat
Electric resistance heat lock-out
Heat pump defrost system
Internal condensate removal (ICR)*
Quick heat recovery
Self-diagnostics
Auto power recovery
Deluxe
2800 Series
Deluxe
Dry Air 25
Standard
Standard
Heat pump
Deluxe
3800 Series
Premium
5800 Series
Standard
—
—
—
—
Standard
Standard
Standard
Standard
—
—
—
—
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Optional
Standard
Optional
Standard
Standard
Standard
Standard
Standard
2
2
2
2
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Hi/Low
Hi/Low
Hi/Low
Hi/Low
Hi/Low
Hi/Low
Hi/Low
Hi/Low
3-stage
3-stage
3-stage
3-stage
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Electronic 7-step Electronic 7-step Electronic 7-step Electronic 7-step
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
—
—
—
Standard
—
—
Standard
Standard
—
Standard
—
—
—
—
—
Standard
—
Standard
—
—
—
—
—
Standard
Standard
Standard
Standard
Reverse cycle
Optional
Standard
—
Standard
Standard
Standard
Standard
Reverse cycle
Optional
Standard
Standard
Standard
*Not for use in corrosive environments
Deluxe models
2800 series and Dry Air 25 series – heat/cool units
3800 series – heat pump unit
Standard microcomputer controls
Central desk control
compatible
Ability to turn the unit
“on” or "off" from a
remote location.
Two fan motors
(not visible)
Separate motors for
indoor and outdoor fans
to assure quiet operation.
Reversible louver
(not shown)
May be reversed to
provide an air discharge
angle of 40 Or 50 degrees
off vertical with the simple
removal of six screws.
3 Position vent control
(not shown)
Opens vent. Provides up
to 75 cfm of outdoor air.
The closed position saves
energy by recirculating
conditioned room air.
Reverse cycle defrost
(not shown)
Solid state sensor
monitors frost build-up
on outdoor coil. When
frost is detected, the
refrigerant flow is reversed
to melt frost build-up.
When completed, the
refrigerant is reversed to
the normal energy saving
heat pump operation for
additional heat pump
operating hours.
Easy access filter
(not shown)
Two upfront interchangeable
filters are part of roomside
cabinet for easy access
and maintenance.
Remote control
compatible
Ability to be controlled
by a wall mounted
thermostat with high
or low fan speed.
Solid state
thermostat control
Provides better room
temperature Control
vs electro-mechanical
temperature control
device.
Freeze Sentinel™
Provides automatic
protection against
freezing by switching
the unit to heat should
the temperature of an
unoccupied room drop
to 41°f.
Heat Sentinel
Provides automatic
protection against
overheating by switching
on the unit to cool should
the temperature of
an unoccupied room
reach 85°f.
Auto frost control
A special sensor monitors
the roomside coil to
prevent efficiency-robbing
accumulation of frost
during cooling operation.
GE Dry Air 25
(not shown) Innovative
technology from Heat
Pipe Technology, Inc.
enables the dry air 25
to remove 25% more
moisture from the air than
standard ge packaged
terminal air conditioners.
Electronic
temperature limiting
Preset cooling and heating
limits with 7 independent
cooling and 7 heating
limits - saves energy by
preventing over-cooling or
over-heating of rooms.
Universal power cord
Flexibility of heat
applications. All
Zonelines contain a
bank of 3 Heaters.
“Smartfan”
fan cycle selection
Select fan cycle or fan
continuous independently
for heating and cooling.
Rotary compressor
With fewer moving
parts than reciprocating
models, for quiet, reliable
operation and longer life.
Room occupancy
sensor compatible
Ready for connection
to room occupancy
sensor system.
The Dry Air 25
Special corrosion protected units
The Dry Air 25 features innovative technology from Heat Pipe
Technology, Inc., an addition which enables this unit to remove 25%
more moisture from the air than standard GE Zoneline models. The
Dry Air 25 system, Heat Pipe, is a hermetically sealed heat transfer
surface that is saddle-bagged around the indoor coil (evaporator) of
the Zoneline. This coil arrangement will transfer heat from one coil to
another without power consumption. This assembly uses R-22 as the
refrigerant and is isolated from the regular Zoneline refrigerant circuit.
To help extend the life of the Zoneline unit in seacoast areas, some
Deluxe Zoneline units may be ordered with a special corrosion
protection treatment on outdoor components and use stainless
steel hardware. Zoneline units with optional Corrosion Protection
have a ‘C’ in the 10th character of the model number.
As warm humid air is pulled through the pre-cool section of the Heat
Pipe, the heat removed from the air is absorbed by the refrigerant,
causing the refrigerant to boil. As the pre-cooled air passes through
the Zoneline evaporator, the air is further cooled (colder than it would
be normally), removing 25% more moisture from the air than standard
GE packaged terminal air conditioners.
As the cold air passes through the reheat section of the Heat Pipe, the
refrigerant condenses and the liquid flows back to the pre-cool section
to be reheated again. The air discharged into the room by this process
is much drier, creating a more comfortable room condition.
Internal condensate removal
Available on the 3800 and 5800 heat pumps, this feature drips the
heat pump condensate over the warm indoor coil to help dissipate
water from heat pump operation and associated defrost cycles. The
installation of an internal or external drain system is recommended if
no dripping of condensate to the outdoors is desired. ICR must not be
installed in seacoast or corrosive applications.
ge.com
Premium models
5800 series and Dry Air 25 series – heat/cool units
Highly featured microcomputer controls
Cross-flow blower
Quiet blower reduces
annoying “Air rush” noise.
Reversible louver
(not shown)
May be reversed to
provide an air discharge
angle of 40 or 50 degrees
off vertical with the
removal of six screws.
3 position vent control
(not shown)
Opens vent. Provides up
to 70 cfm of outdoor air.
The closed position saves
energy by recirculating
conditioned room air.
Two fan motors
(not visible)
Separate motors for
indoor and outdoor fans
to assure quiet operation.
Touch pad controls
With electronic control
temperature display,
gives the user finer control
over the temperature.
Solid state
thermostat control
Provides better room
temperature control
vs electro-mechanical
temperature control
device.
Freeze Sentinel™
Provides automatic
protection against
freezing by switching
the unit to heat should
the temperature of an
unoccupied room drop
to 41°f.
Heat Sentinel
Provides automatic
protection against
overheating by switching
on the unit to cool should
the temperature of
an unoccupied room
reach 85°f.
Room occupancy
sensor compatible
Ready for connection
to room occupancy
sensor system.
Weather protected
electrical components
On inside of barrier.
Reverse cycle defrost
(not shown)
Solid state sensor
monitors frost build-up
on outdoor coil. When
frost is detected, the
refrigerant flow is reversed
to melt frost build-up.
When completed, the
refrigerant is reversed
to the normal energy
saving heat pump
operation for additional
heat pump operating hours.
Auto frost
control monitor
A special sensor monitors
the roomside coil to
prevent efficiency-robbing
accumulation of frost
during cooling cycle.
Electronic
temperature limiting
Preset cooling and heating
limits with 7 independent
cooling and 7 heating
limits - saves energy by
preventing over-cooling or
over-heating of rooms.
Universal power cord
Flexibility of heat
applications. Each
premium line Zoneline
contains a bank of
3 heaters.
Microcomputer controls
Electronic components
for fast response and
accuracy.
“Smartfan”
Fan cycle selection
Select fan cycle or fan
continuous independently
for heating and cooling.
Wall sleeve dimensions
Heavy-gauge galvanized
steel with a baked enamel
finish for outstanding
protection and appearance.
C
RAB71A wall sleeve
RAB77 wall sleeve (shown above)
Molded SMC fiberglass-reinforced polyester compound.
A-42 1/8", B-13 7/8", C-16 1/4"
Wall opening dimensions
Add 1/4" to A and C dimensions for all cutout size.
RAB71 16 1/4" min. H. x 42 1/4" min. W.
RAB71 available in 16", 24", 28" and 31" depths.
RAB77 16 1/2" min. H. x 42 3/8" min. W.
Central desk
control compatible
Ability to turn the unit
“on” or “off” from a
remote location.
Easy access filter
(not shown)
Two upfront filters
are part of roomside
cabinet for easy access
and maintenance.
Remote control
compatible
Ability to be controlled
by a wall mounted
thermostat with high
or low fan speed.
Electrical connection
A
Heavy-gauge galvanized steel, with insulation.
A-42", B-13 3/4", C-16"
Rotary compressor
With fewer moving
parts than reciprocating
models for quiet,
reliable operation.
B
230/208 volt units may be plugged into
a receptacle. 265 volt units are provided
with a junction box and require direct
connection. (NEC Requires 265V Direct
Connection.) See Architects and Engineers
Design Data Manual for electrical
connection information including use of
sub-base for direct connected units. Installation
must comply with local electrical codes and regulations.
Ducted applications
2800 and 3800 series can be used with ductwork to heat or cool more
than one room. RAK6052 Duct Adapter is applied to top of case over air
discharge. RAK601 Duct Extension is applied to right or left of adapter.
Locally fabricated ductwork may be added to extend to maximum
recommended distance of 15 feet.
For additional information on ducted applications, including special
adapters for replacement units, refer to Architects and Engineers Design
Data Manual.
Receptacles/Sub-bases
Tandem
230/208V 15 Amp
NEMA6-15R
Perpendicular
230/208V 20 Amp
NEMA6-20R
Large tandem
230/208V 30 Amp
NEMA6-30R
265V 15 Amp
NEMA7-15R
265V 20 Amp
NEMA7-20R;
receptacle used
On 265V sub-base
GE0720-3
265V 30 Amp
NEMA7-30R;
receptacle used
On 265V sub-base
GE073
Sub-bases
RAK204U
RAK204D15P
RAK204D20P
RAK204D30P
RAK204E15
RAK204E20
RAK204E30
Voltage
N/A230/208230/208230/208265265265
Amps
N/A
Receptacle
N/A
152030
NEMA6-20R
NEMA6-20R
152030
NEMA6-30R
NEMA7-15R
NEMA7-20R
NEMA7-30R
230/208 Volt sub-bases include appropriate power cord kit.
265 Volt units are to be direct connected. Cordset through enclosed chaseway into interior sub-base receptacle meets the NEC requirements.
Power connection kits are required on all Zoneline chassis (see chart below).
The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the
building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if the unit is to be permanently connected, a permanent
connection kit would be used. 265 volt cord set units must be installed in compliance with National Electrical Code®.
Power connection kits
Required on all models. See specification sheet
for heater KW and branch circuit ampacity.
RAK3153/3203
230/208 volt line cord
connection kit
RAK3303
230/208 volt line cord
connection kit
230/208 volt
LCDI Power Connection Kit
RAK5172
Permanent connected units** (Cord set)
RAK5202
RAK5302
RAK3203
RAK3303
Heater KW
2.55/2.093.45/2.82
5.00/4.09
2.553.45
5.0
Watts
2,550/2,0903,450/2,820
5,000/4,090
2,5603,450
5,000
BTUH
8,600/7,100
Amps
11.0/10.0
11,700/9,600
17,000/13,900
15.0/13.621.7/19.7
8,600
11,700
17,000
9.6
13.0
18.9
Min. circuit amps
152030
152030
Recommended
protective
device
15 Amp20 amp30 amp
time delay
time delay
time delay
fuse or breaker
fuse or breaker
fuse or breaker
15 Amp20 amp30 amp
time delay fuse
time delay fuse
time delay fuse
**To be used with sub-base
10
265 volt
Line cord connected units
RAK3153
ge.com
Specifications
Deluxe series – cooling & electric heat
230/208V Models
AZ28E07D
Capacity
Dry Air 25
2800 series units
AZ28E09D
AZ28E12D
AZ28E15D
AZ28E07DAP
Dry Air 25
AZ28E09DAP
AZ28E12DAP
Cooling BTUH
7,100/6,900
9,000/8,800
11,700/11,500
14,600/14,3006,800/6,600
8,600/8,400
11,200/11,000
EER (BTU/Watt)
12.7/12.7
12.0/12.0
11.5/11.5
10.2/10.2
12.1/12.1
11.5/11.5
11.0/11.0
Dehumidification Pts/Hr
1.72.73.64.52.23.44.5
Sensible heat ratio @ 230 volts
75%68%67%67%66%
58%
57%
CFM, indoor fan high250270290310210230240
CFM, indoor fan low215235240260
175200210
Vent CFM (full open/partial open)
50/40
70/45
75/45
75/45
50/40
70/45
75/45
Power/Ratings
Power factor
86/87
86/86
91/91
89/90
87/87
86/86
91/91
Watts
560/545
750/735
1020
1430/1400
560/545
750/730
1020
Amperes, F.L.2.8/3.03.8/4.14.9/5.3
7.0/7.52.8/3.03.6/3.94.9/5.3
Amperes, L.R.
19.021.031.038.0
19.021.031.0
Weight (Net/Ship)
100/115
101/116
105/120
115/130
100/115
101/116
105/120
Sound Transmission Class (STC)29292929292929
265V Models
Capacity
AZ28E07E
AZ28E09E
AZ28E12E
AZ28E15E
AZ28E07EAP
AZ28E09EAP
AZ28E12EAP
Cooling BTUH
7,100
9,000
11,700
14,6006,800
8,600
11,200
EER (BTU/Watt)
12.7
12.0
11.5
10.2
12.1
11.5
11.0
Dehumidification Pts/Hr
1.72.73.64.52.23.44.5
Sensible heat ratio @ 265 volts
75%68%67%67%66%
58%
57%
CFM, indoor fan high250270290310210235250
CFM, indoor fan low215235240280
175200
00
Vent CFM (full open/partial open)
50/40
70/45
75/45
75/45
50/40
70/45
75/45
Power/Ratings
Power factor
87
86
87
90
88
86
87
Watts
560/545
750
1020
1431
560
750
1020
Amperes, F.L.2.4/3.03.34.46.02.43.34.4
Amperes, L.R.
16.0
18.024.031.0
16.0
18.024.0
Weight (Net/Ship)
100/115
101/116
105/120
115/130
100/115
101/116
105/120
Sound Transmission Class (STC)29292929292929
Deluxe series – heat pump units
230/208V Models
AZ38H07D
Capacity
Premium series – heat pump units
3800 series units
AZ38H09D
AZ38H12D
AZ38H15D
AZ58H07D
5800 series units
AZ58H09D
AZ58H12D
AZ58H15D
Cooling BTUH
7,100/6,900
9,000/8,800
11,700/11,500
14,600/14,300
7,100/6,900
9,000/8,800
11,800/11,600
14,700/14,400
EER (BTU/Watt)
12.7/12.7
12.0/12.0
11.5/11.5
10.0/10.0
13.0/13.0
12.0/12.0
11.5/11.5
10.2/10.2
Dehumidification Pts/Hr
1.72.73.64.5
1.72.83.64.8
Sensible heat ratio @ 230 volts
75%68%67%67%
75%67%68%65%
CFM, indoor fan high250270300310240290330350
CFM, indoor fan low2152350260260220270310330
Vent CFM (full open/partial open)
50/40
70/45
75/45
75/45
50/40
70/45
75/45
75/45
Power/Ratings
Power factor
86/87
96
97
94
95
96
94
95
Watts
560/545
750/735
1020/1000
1460/1430
546/531
750/733
1026/1009
1441/1412
Amperes, F.L.2.8/3.03.8/4.14.9/5.3
7.0/7.52.7/2.93.6/3.9
5.1/5.56.7/7.3
Amperes, L.R.
19.021.031.038.0
19.021.033.038.0
Reverse cycle heat BTUH6400/6200
8400/8200
10900/10700
13400/132006,400/6,200
8,400/8,200
10,900/10,700
13,400/13,200
COP3.63.63.43.23.5/3.53.5/3.53.3/3.33.1/3.1
Watts
520/505685/670
940/925
1230/1210
535/520
700/685
970/950
1,265/1,250
Amps2.4/2.63.2/3.54.3/4.7
5.8/6.32.4/2.63.1/3.34.3/4.7
5.8/6.3
Weight (Net/Ship)
102/117
109/124
113/128
13/138
109/122
114/129
118/133
128/143
Sound Transmission Class (STC)2929292929292929
265V Models
Capacity
AZ38H07E
AZ38H09E
AZ38H12E
AZ38H15E
AZ58H07E
AZ58H09E
AZ58H12E
AZ58H15E
Cooling BTUH
7,100
9,000
11,700
14,600
7,100
9,000
11,800
14,700
EER (BTU/Watt)
12.7
12.0
11.5
10.0
13.0
12.0
11.5
10.2
Dehumidification Pts/Hr
1.72.73.64.5
1.72.83.64.8
Sensible heat ratio @ 265 volts
75%68%67%67%
75%67%68%65%
CFM, indoor fan high250270300310240290330350
CFM, indoor fan low215235260260220270310330
Vent CFM (full open/partial open)
50/40
70/45
75/45
75/45
50/40
70/45
75/45
75/45
Power/Ratings
Power factor
96
94
94
96
96
94
94
96
Watts
560
750
1020
1460
546
750
1026
1441
Amperes, F.L.2.43.24.46.02.33.24.5
5.8
Amperes, L.R.
16.0
18.024.031.0
16.0
18.024.031.0
Reverse cycle heat BTUH6,400
8,400
10,900
13,4006,400
8,400
10,900
13,400
COP3.63.63.43.23.53.53.33.1
Watts
520685
940
1230
535
705
970
1,265
Amps2.22.83.9
5.02.22.83.9
5.0
Weight (Net/Ship)**
102/117
109/124
113/128
123/138
101/122
114/129
118/133
128/153
Sound Transmission Class (STC)2929292929292929
**ICR adds 3 pounds to unit weight
11
Zoneline® chassis nomenclature
Zoneline warranty*
The Zoneline chassis is identified by a model number defining the type
of unit, cooling capacity, electrical information and optional features
included on the unit. When specifying or ordering the Zoneline chassis
use of this nomenclature will assure receiving the correct unit.
What is covered
A
Z
5
8
H
Zoneline Chassis series
packaged 28=deluxe line cool/
electric heat
terminal
38=deluxe line heat pump
chassis
58=premium line
heat pump
Unit type
E=cooling with electric
resistance heat
H=heat pump with electric
resistance heat
1
2
Nominal cooling capacity
07=7,000 BTUH cooling
09=9,000 BTUH cooling
12=12,000 BTUH cooling
15=15,000 BTUH cooling
D
A
D
Universal
power connection
Special Features
B=base unit
C=corrosion treated
D=internal
Voltage/Phase/
condensate
Frequency
removal (ICR)
D=230/208 Volt, single
system (heat
phase, 60 Hz
pump models
E=265 Volt, single phase,
only) (not for
60 Hz
coastal areas)
P=Dry Air 25
Full one-year warranty
For one year from date of original purchase, we will provide, free of
charge, parts and service labor on site to repair or replace any part
of the zoneline that fails because of a manufacturing defect.
Full five-year warranty
For five years from the date of original purchase, we will provide, free of
charge, parts and on-site service labor to repair or replace any part of
the sealed refrigerating system (the compressor, condenser, evaporator
and all connecting tubing) that fails because of a manufacturing defect.
Limited 2nd through 5th year parts warranty
For the second through the fifth year from date of original purchase,
general electric will provide, free of charge, parts that fail as a result
of a manufacturing defect. Parts covered are fan motors, switches,
thermostat, heater, heater protectors, compressor overload, solenoids,
circuit boards, auxiliary controls, thermistors, frost controls, icr pump,
capacitors, varistors, and indoor blower bearing. This is a limited
parts-only warranty, and does not include labor or transportation
to and from the service shop.
All warranty service will be provided by our factory service centers or by
our authorized customer care® servicers during normal working hours.
RE
TU
T
IFIED O ARI A
S
PAC
AL
-C
ONDITIONE
G WITH
R
R
IR
STA
CO
TE
ED
IN
KA
G
M
KA
RT
R
AL
G WITH
IN
PAC
CE
YIN
M
RI
R
PL
R
A
A
CO
TE
YIN
MA NUFAC
T
IFIED O ARI A
S
ED
PL
G
MA NUFAC
RT
TU
CE
M
R
M
Listed by
Underwriters'
Laboratories.
RE
*See written warranty for details
RS
NDARD
31
0
A
HE
RI
AT PUMPS
STA
NDARD
38
0
For detailed information on operating specifications, installation data and accessories,
see the GE Zoneline Architects and Engineers Design Data manual.
A Century of Quality and Innovation
For more than a century, GE has been committed to producing innovative products
that change the way people live. The result of thorough research and rigorous testing,
GE appliances are designed for years of dependable performance.
Today, the GE tradition of quality and innovation continues.
For GE appliance service in the US, call
1-800-GE CARES. In Canada call 1-888-209-0999
GE Consumer & Industrial
Appliances
General Electric Company
Louisville, KY 40225
ge.com
GE has a policy of continuous improvement of
its products and reserves the right to change
materials and specifications without notice.
© 2004 GE Company
Pub. No. 20-S045 PC40898
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising